Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 8
Encontrada(s) 1 página(s)

Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Brain correlates of speech perception in schizophrenia patients with and without auditory hallucinations

  • Soler-Vidal, Joan
  • Fuentes-Claramonte, Paola
  • Salgado-Pineda, Pilar
  • Ramiro-Sousa, Nuria
  • García-León, María Ángeles
  • Llanos Torres, María
  • Arévalo, Antonio
  • Guerrero-Pedraza, Amalia
  • Munuera, Josep
  • Sarró, Salvador
  • Salvador, Raymond
  • Hinzen, Wolfram
  • McKenna, Peter J.
  • Pomarol-Clotet, Edith
The experience of auditory verbal hallucinations (AVH, “hearing voices”) in schizophrenia has been found to be associated with reduced auditory cortex activation during perception of real auditory stimuli like tones and speech. We re-examined this finding using 46 patients with schizophrenia (23 with frequent AVH and 23 hallucination-free), who underwent fMRI scanning while they heard words, sentences and reversed speech. Twenty-five matched healthy controls were also examined. Perception of words, sentences and reversed speech all elicited activation of the bilateral superior temporal cortex, the inferior and lateral prefrontal cortex, the inferior parietal cortex and the supplementary motor area in the patients and the healthy controls. During the sentence and reversed speech conditions, the schizophrenia patients as a group showed reduced activation in the left primary auditory cortex (Heschl’s gyrus) relative to the healthy controls. No differences were found between the patients with and without hallucinations in any condition. This study therefore fails to support previous findings that experience of AVH attenuates speech-perception-related brain activations in the auditory cortex. At the same time, it suggests that schizophrenia patients, regardless of presence of AVH, show reduced activation in the primary auditory cortex during speech perception, a finding which could reflect an early information processing deficit in the disorder., This work was supported by the CIBERSAM and the Catalonian Government (2017SGR01271 to EP-C and 2017SGR1265 to WH). Also by a grant from the Plan Nacional de I+D+i 2013–2016: Juan de la Cierva-formación contract (FJCI-2015-25278 to PF-C) and two projects from the Ministerio de Ciencia, Innovación y Universidades (MCIU) y la Agencia Estatal de Investigación (AEI), FFI2016-77647-C2-2-P to WH and PS-P and PID2019-110120RBI00/AEI/10.13039/501100011033 to WH); and by the Instituto de Salud Carlos III, co-funded by European Union (ERDF/ESF, “Investing in your future”): Miguel Servet Research contracts (CPII13/00018 to RS and MS10/00596 to EP-C), Sara Borrell contract (CD19/00149 to PF-C) and Research Project Grants (PI18/00880 to PM).
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

A computational comparison of radiofrequency and pulsed field ablation in terms of lesion morphology in the cardiac chamber

  • Gómez‑Barea, Mario
  • Garcia-Sanchez, Tomas
  • Ivorra Cano, Antoni, 1974-
Pulsed Field Ablation (PFA) has been developed over the last years as a novel electrical ablation technique for treating cardiac arrhythmias. It is based on irreversible electroporation which is a non-thermal phenomenon innocuous to the extracellular matrix and, because of that, PFA is considered to be safer than the reference technique, Radiofrequency Ablation (RFA). However, possible differences in lesion morphology between both techniques have been poorly studied. Simulations including electric, thermal and fluid physics were performed in a simplified model of the cardiac chamber which, in essence, consisted of a slab of myocardium with blood in motion on the top. Monopolar and bipolar catheter configurations were studied. Different blood velocities and catheter orientations were assayed. RFA was simulated assuming a conventional temperature-controlled approach. The PFA treatment was assumed to consist in a sequence of 20 biphasic bursts (100 µs duration). Simulations indicate that, for equivalent lesion depths, PFA lesions are wider, larger and more symmetrical than RFA lesions for both catheter configurations. RFA lesions display a great dependence on blood velocity while PFA lesions dependence is negligible on it. For the monopolar configuration, catheter angle with respect to the cardiac surface impacted both ablation techniques but in opposite sense. The orientation of the catheter with respect to blood flow direction only affected RFA lesions. In this study, substantial morphological differences between RFA and PFA lesions were predicted numerically. Negligible dependence of PFA on blood flow velocity and direction is a potential important advantage of this technique over RFA., This work was partially supported by project (PID2019-110120RBI00/AEI/10.13039/501100011033) from the Ministry of Science, Innovation and Universities and the State Research Agency of the Spanish government. Mario Gómez-Barea research is supported by a scholarship from the UPF. Tomás García-Sánchez acknowledges the funding received from the European Union’s Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement No 892393 (TACAIRE). Antoni Ivorra gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Parametric study of pulsed field ablation with biphasic waveforms in an in vivo heart model: the role of frequency

  • Garcia-Sanchez, Tomas
  • Amorós Figueras, Gerard
  • Jorge, Esther
  • Campos, María C.
  • Maor, Elad
  • Guerra, Jose M.
  • Ivorra Cano, Antoni, 1974-
Data de publicació electrónica: 30-09-2022, BACKGROUND: Pulsed field ablation (PFA) is a novel non-thermal cardiac ablation technology based on irreversible electroporation. Unfortunately, the characteristics of the electric field waveforms used in clinical and experimental PFA are not typically reported. This study examines the effect of the frequency of biphasic waveforms and compares biphasic to monophasic waveforms. METHODS: A total of 29 Sprague-Dawley rats were treated with PFA using an epicardial monopolar electrode. Biphasic waveforms with three different frequencies, 90, 260 and 450 kHz (10 bursts of 100 µs duration at 500 V or 800 V) and monophasic waveforms (10 pulses of 100 µs duration at 500 V) were studied. Collateral neuromuscular stimulation and temperature increase in the point of application were directly measured. Lesion formation was assessed 3 weeks after treatment by histopathologic analysis. Computer simulations were used to estimate the electric field lethal threshold for each condition. A previous in vitro study was performed to draw a complete characterization of the studied dependencies. RESULTS: Morphometric analysis demonstrated a significant association between chronic lesion size and waveform characteristics. For the same voltage level, monophasic waveforms yielded the largest lesions compared to any of the biphasic protocols (p<0.05). Increasing PFA frequency was associated with reduced neuromuscular stimulation but also with reduced ablation efficacy. Maximum absolute temperature increase recorded along a complete treatment was 3 °C. Vascular structures inside the lesions were preserved for all conditions. Computer simulation-based analysis showed that waveform frequency had a graded effect on the lethal electric field threshold, with threshold of 600 V/cm for monophasic waveforms vs. 2000 V/cm for biphasic waveforms with a frequency of 450 kHz. CONCLUSIONS: Frequency is a major determinant of efficacy in biphasic PFA. Our results highlight the critical need of disclosing waveform characteristics when reporting the results of different PFA systems., This work was partially supported by project (PID2019-110120RBI00/AEI/ 10.13039/501100011033) from the Ministry of Science, Innovation and Universities and the State Research Agency of the Spanish government. This project has received funding from the European Union’s Horizon 2020 research and innovation program under the Marie SkłodowskaCurie grant agreement No 892393 (TACAIRE). Antoni Ivorra gratefully acknowledges financial support by ICREA under the ICREA Academia program.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Comparing high-frequency with monophasic electroporation protocols in an in vivo beating heart model

  • Heller, Eyal
  • Garcia-Sanchez, Tomas
  • Moshkovits, Yonatan
  • Rabinovici, Raul
  • Grynberg, Dvora
  • Segev, Amit
  • Asirvatham, Samuel J.
  • Ivorra Cano, Antoni, 1974-
  • Maor, Elad
This study compared monophasic 100-μs pulses with high-frequency electroporation (HF-EP) bursts using an in vivo animal model. Myocardial damage was evaluated by histologic analysis. Compared with 10 monophasic pulses, 20 bursts of HF-EP at 100 and 150 kHz were associated with less damage. However, when the number of HF-EP bursts was increased to 60, myocardial damage was comparable to that of the monophasic group. HF-EP protocols were associated with attenuated collateral muscle contractions. This study shows that HF-EP is feasible and effective and that pulse frequency has a significant effect on extent of ablation., Funded by the Nicholas and Elizabeth Shlezak Super Center for Cardiac Research and Biomedical Engineering at Tel Aviv University; Mayo Clinic–Sheba innovation grant; project (PID2019-110120RBI00/AEI/10.13039/501100011033) from the Ministry of Science, Innovation, and Universities; and the State Research Agency of the Spanish government and by the Beatriu de Pinos program from the Ministry of Business and Knowledge of the Government of Catalonia (grant identifier: 2017 BP 00032). Dr Ivorra gratefully acknowledges financial support by the Catalan Institution for Research and Advanced Studies (ICREA) under the ICREA Academia program.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Parametric study of pulsed field ablation with biphasic waveforms in an in vivo heart model: the role of frequency

  • Garcia-Sanchez, Tomas
  • Amorós Figueras, Gerard
  • Jorge, Esther
  • Campos, María C.
  • Maor, Elad
  • Guerra, Jose M.
  • Ivorra Cano, Antoni, 1974-
Data de publicació electrónica: 30-09-2022, BACKGROUND: Pulsed field ablation (PFA) is a novel non-thermal cardiac ablation technology based on irreversible electroporation. Unfortunately, the characteristics of the electric field waveforms used in clinical and experimental PFA are not typically reported. This study examines the effect of the frequency of biphasic waveforms and compares biphasic to monophasic waveforms. METHODS: A total of 29 Sprague-Dawley rats were treated with PFA using an epicardial monopolar electrode. Biphasic waveforms with three different frequencies, 90, 260 and 450 kHz (10 bursts of 100 µs duration at 500 V or 800 V) and monophasic waveforms (10 pulses of 100 µs duration at 500 V) were studied. Collateral neuromuscular stimulation and temperature increase in the point of application were directly measured. Lesion formation was assessed 3 weeks after treatment by histopathologic analysis. Computer simulations were used to estimate the electric field lethal threshold for each condition. A previous in vitro study was performed to draw a complete characterization of the studied dependencies. RESULTS: Morphometric analysis demonstrated a significant association between chronic lesion size and waveform characteristics. For the same voltage level, monophasic waveforms yielded the largest lesions compared to any of the biphasic protocols (p<0.05). Increasing PFA frequency was associated with reduced neuromuscular stimulation but also with reduced ablation efficacy. Maximum absolute temperature increase recorded along a complete treatment was 3 °C. Vascular structures inside the lesions were preserved for all conditions. Computer simulation-based analysis showed that waveform frequency had a graded effect on the lethal electric field threshold, with threshold of 600 V/cm for monophasic waveforms vs. 2000 V/cm for biphasic waveforms with a frequency of 450 kHz. CONCLUSIONS: Frequency is a major determinant of efficacy in biphasic PFA. Our results highlight the critical need of disclosing waveform characteristics when reporting the results of different PFA systems., This work was partially supported by project (PID2019-110120RBI00/AEI/ 10.13039/501100011033) from the Ministry of Science, Innovation and Universities and the State Research Agency of the Spanish government. This project has received funding from the European Union’s Horizon 2020 research and innovation program under the Marie SkłodowskaCurie grant agreement No 892393 (TACAIRE). Antoni Ivorra gratefully acknowledges financial support by ICREA under the ICREA Academia program.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

A computational comparison of radiofrequency and pulsed field ablation in terms of lesion morphology in the cardiac chamber

  • Gómez‑Barea, Mario
  • Garcia-Sanchez, Tomas
  • Ivorra Cano, Antoni, 1974-
Pulsed Field Ablation (PFA) has been developed over the last years as a novel electrical ablation technique for treating cardiac arrhythmias. It is based on irreversible electroporation which is a non-thermal phenomenon innocuous to the extracellular matrix and, because of that, PFA is considered to be safer than the reference technique, Radiofrequency Ablation (RFA). However, possible differences in lesion morphology between both techniques have been poorly studied. Simulations including electric, thermal and fluid physics were performed in a simplified model of the cardiac chamber which, in essence, consisted of a slab of myocardium with blood in motion on the top. Monopolar and bipolar catheter configurations were studied. Different blood velocities and catheter orientations were assayed. RFA was simulated assuming a conventional temperature-controlled approach. The PFA treatment was assumed to consist in a sequence of 20 biphasic bursts (100 µs duration). Simulations indicate that, for equivalent lesion depths, PFA lesions are wider, larger and more symmetrical than RFA lesions for both catheter configurations. RFA lesions display a great dependence on blood velocity while PFA lesions dependence is negligible on it. For the monopolar configuration, catheter angle with respect to the cardiac surface impacted both ablation techniques but in opposite sense. The orientation of the catheter with respect to blood flow direction only affected RFA lesions. In this study, substantial morphological differences between RFA and PFA lesions were predicted numerically. Negligible dependence of PFA on blood flow velocity and direction is a potential important advantage of this technique over RFA., This work was partially supported by project (PID2019-110120RBI00/AEI/10.13039/501100011033) from the Ministry of Science, Innovation and Universities and the State Research Agency of the Spanish government. Mario Gómez-Barea research is supported by a scholarship from the UPF. Tomás García-Sánchez acknowledges the funding received from the European Union’s Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement No 892393 (TACAIRE). Antoni Ivorra gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Brain correlates of speech perception in schizophrenia patients with and without auditory hallucinations

  • Soler-Vidal, Joan
  • Fuentes-Claramonte, Paola
  • Salgado-Pineda, Pilar
  • Ramiro-Sousa, Nuria
  • García-León, María Ángeles
  • Llanos Torres, María
  • Arévalo, Antonio
  • Guerrero-Pedraza, Amalia
  • Munuera, Josep
  • Sarró, Salvador
  • Salvador, Raymond
  • Hinzen, Wolfram
  • McKenna, Peter J.
  • Pomarol-Clotet, Edith
The experience of auditory verbal hallucinations (AVH, “hearing voices”) in schizophrenia has been found to be associated with reduced auditory cortex activation during perception of real auditory stimuli like tones and speech. We re-examined this finding using 46 patients with schizophrenia (23 with frequent AVH and 23 hallucination-free), who underwent fMRI scanning while they heard words, sentences and reversed speech. Twenty-five matched healthy controls were also examined. Perception of words, sentences and reversed speech all elicited activation of the bilateral superior temporal cortex, the inferior and lateral prefrontal cortex, the inferior parietal cortex and the supplementary motor area in the patients and the healthy controls. During the sentence and reversed speech conditions, the schizophrenia patients as a group showed reduced activation in the left primary auditory cortex (Heschl’s gyrus) relative to the healthy controls. No differences were found between the patients with and without hallucinations in any condition. This study therefore fails to support previous findings that experience of AVH attenuates speech-perception-related brain activations in the auditory cortex. At the same time, it suggests that schizophrenia patients, regardless of presence of AVH, show reduced activation in the primary auditory cortex during speech perception, a finding which could reflect an early information processing deficit in the disorder., This work was supported by the CIBERSAM and the Catalonian Government (2017SGR01271 to EP-C and 2017SGR1265 to WH). Also by a grant from the Plan Nacional de I+D+i 2013–2016: Juan de la Cierva-formación contract (FJCI-2015-25278 to PF-C) and two projects from the Ministerio de Ciencia, Innovación y Universidades (MCIU) y la Agencia Estatal de Investigación (AEI), FFI2016-77647-C2-2-P to WH and PS-P and PID2019-110120RBI00/AEI/10.13039/501100011033 to WH); and by the Instituto de Salud Carlos III, co-funded by European Union (ERDF/ESF, “Investing in your future”): Miguel Servet Research contracts (CPII13/00018 to RS and MS10/00596 to EP-C), Sara Borrell contract (CD19/00149 to PF-C) and Research Project Grants (PI18/00880 to PM).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Comparing high-frequency with monophasic electroporation protocols in an in vivo beating heart model

  • Heller, Eyal
  • Garcia-Sanchez, Tomas
  • Moshkovits, Yonatan
  • Rabinovici, Raul
  • Grynberg, Dvora
  • Segev, Amit
  • Asirvatham, Samuel J.
  • Ivorra Cano, Antoni, 1974-
  • Maor, Elad
This study compared monophasic 100-μs pulses with high-frequency electroporation (HF-EP) bursts using an in vivo animal model. Myocardial damage was evaluated by histologic analysis. Compared with 10 monophasic pulses, 20 bursts of HF-EP at 100 and 150 kHz were associated with less damage. However, when the number of HF-EP bursts was increased to 60, myocardial damage was comparable to that of the monophasic group. HF-EP protocols were associated with attenuated collateral muscle contractions. This study shows that HF-EP is feasible and effective and that pulse frequency has a significant effect on extent of ablation., Funded by the Nicholas and Elizabeth Shlezak Super Center for Cardiac Research and Biomedical Engineering at Tel Aviv University; Mayo Clinic–Sheba innovation grant; project (PID2019-110120RBI00/AEI/10.13039/501100011033) from the Ministry of Science, Innovation, and Universities; and the State Research Agency of the Spanish government and by the Beatriu de Pinos program from the Ministry of Business and Knowledge of the Government of Catalonia (grant identifier: 2017 BP 00032). Dr Ivorra gratefully acknowledges financial support by the Catalan Institution for Research and Advanced Studies (ICREA) under the ICREA Academia program.