DAÑO A FATIGA ALTERNA EN HORMIGON DE MUY ALTA RESISTENCIA A TRACCION REFORZADO CON FIBRAS. MAPEO Y CUANTIFICACION DEL DAÑO CON TOMOGRAFIA COMPUTERIZADA.

PID2019-110928RB-C32

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2019
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD DE BURGOS

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

Repositorio Institucional de la Universidad de Burgos (RIUBU)
Publicación Artículo científico (JournalArticle)

Size effect of steel fiber–reinforced concrete cylinders under compressive fatigue loading: Influence of the mesostructure

  • González Cabrera, Dorys Carmen
  • Mena Alonso, Álvaro
  • Ruiz, Gonzalo
  • Ortega Parreño, José Joaquín
  • Poveda, Elisa
  • Mínguez Algarra, Jesús
  • Yu, Rena C.
  • Rosa, Ángel de la
  • Vicente Cabrera, Miguel Ángel
This study deals with the influence of the fiber concrete mesostructure on the size effect under compressive fatigue loading. For this purpose, three series of cylindrical specimens of steel fiber–reinforced concrete were fabricated. Before fatigue testing, all the cylinders were scanned and the main morphological, orientation, and distribution parameters of the pores and fibers were checked. The images reveal that, near the cylinders’ walls, the porosity is lower than that in the cores and is even lower for large sizes. Additionally, larger specimens are more vulnerable to compressive fatigue loading, resulting in a reduction in fatigue life., The authors are grateful for the financial support from the Ministerio de Economía y Competitividad, Spain with grant nos. PID2019-110928RBC32, PID2019–110928RB–C31, and RTC–2017–6736–3, and from the Junta de Comunidades de Castilla-La Mancha, Spain through grant no. SBPLY/19/180501/000220.
Repositorio Institucional de la Universidad de Burgos (RIUBU)
Publicación Artículo científico (JournalArticle)

Influence of air-entraining agent and freeze-thaw action on pore structure in high-strength concrete by using CT-Scan technology

  • González Cabrera, Dorys Carmen
  • Mena Alonso, Álvaro
  • Mínguez Algarra, Jesús
  • Vicente Cabrera, Miguel Ángel
In this work, the effects caused by both the amount of air-entraining agent (AEA) and freeze-thaw cycles on microstructure of high-strength concrete have been analyzed. For this purpose, five series of concrete specimens have been manufactured, each of them containing a different amount of AEA. Then, all series have been subjected to up to 300 freeze-thaw cycles. In addition, the specimens have been analyzed using a computed tomography (CT) scan device at pre-defined freeze-thaw cycles and all data have been processed with digital image processing (DIP) software. The results reveal, on the one hand, that the quantity of AEA has a greater influence on pore structure, and additionally the freeze-thaw action only slightly modifies the pore structure. As AEA increases, a progressive rise of the porosity and the number of pores is observed up to a maximum value. Next, a decrease is noticed. Moreover, there is not a linear relation between porosity and AEA. Furthermore, as AEA increases, a variation of its size and shape is observed. Alternatively, the effect of freeze-thaw cycles is more complex and does not show a monotonous tendency. The results reveal that the first 50 freeze-thaw cycles have the strongest influence on pore structure, observing a decrease in porosity. For the rest of the cycles, the porosity increases progressively resulting, after 300 freeze-thaw cycles, in a slightly lower porosity in almost all series than in those presented at the beginning. Hydration of unhydrated cement particles alongside with microcracking act as opposite performances during the freeze-thaw cycles. Therefore, this can suggest that, under these conditions, freeze-thaw action is not able to damage significantly the microstructure of concrete. The results show that the series with a lower AEA content show a better behavior under freeze-thaw cycles. In this case, the specimens exhibit a lower porosity and a higher level of small pores, and the pores evince a more elongated shape. All these features lead to a more impermeable concrete and, therefore, with a better performance under freeze-thaw cycles., The authors are grateful for the financial support from the Ministerio de Economía y Competitividad, PID2019-110928RB-C32, Spain.