Pasar al contenido principal

EL ROL DE LA CONDUCTIVIDAD ELECTRICA LITOSFERICA DE IBERIA EN LA CARACTERIZACION Y PREDICCION DE LAS GIC EN INFRAESTRUCTURAS CRITICAS

PID2020-113135RB-C31

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2020
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD DE BARCELONA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

High-resolution scan of the Pyrenean crustal structure combining magnetotelluric and gravity data

  • Piña-Varas, Perla
  • Soto, Ruth
  • Clariana, Pilar
  • Ayala, C.
  • Rubio Sánchez-Aguililla, Félix Manuel
  • Ledo, Juanjo
  • Rey-Moral, Carmen
  • Marti, A.
  • Mitjanas, G.
  • Queralt, P.
  • Marcuello, A.
  • Santolaria, Pablo
  • Pueyo Morer, Emilio Luis
The Pyrenees have undergone complex geodynamic evolution starting with experiencing significant tectonic events during the Variscan Orogeny, followed by the intrusion of large granitic complexes during the late Variscan stage, then the collision between the Iberian and European plates during the Alpine Orogeny, and finally, Mesozoic extension. Despite extensive studies and the application of various geophysical methods (two-dimensional seismic reflection data, gravity, and long period magnetotellurics) to investigate the Pyrenean structure, there are still fundamental questions regarding its basement and cover architecture. Specifically, the geometry at depth of significant bodies such as the Late Variscan intrusive granites and Triassic evaporitic accumulations, remains unclear. To better understand these issues, we have conducted joint magnetotelluric and gravity surveys along a 60-km-long transect, spanning the boundary between the Axial and South Pyrenean Zones. Our final geological interpretation shows that the La Maladeta batholith consists of two distinct granitic bodies related to different intrusive pulses. In addition, we identify important Triassic evaporitic accumulations at depth. This work shows the high potential of integrating two geophysical models for understanding the geological evolution of structurally complex areas. The magnetotelluric and gravity data are complementary, with each dataset providing a different resolution for investigating the basement and cover architecture of the Pyrenees. These resolutions depend on the varied petrophysical properties of the rocks involved, including water content and deformation grade., This work was funded by projects PID2020-114273GB-C22 and PID2020-113135RB-C31 funded by MCIN/AEI/10.13039/501100011033 and CGL2017-82169-C2-2-R, from the Spanish Ministry of Science and Innovation. The authors acknowledge the contribution of José María Llorente, Agustín González, and Arturo García for the acquisition of the gravity data. This study also represents a contribution to GeoAp Research Group (E01-20R) (Aragón Government).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Replication Data for: Data-driven transfer functions from differential magnetometer measurements to enhance GIC model validation capability: A case study in the Spanish power grid

  • Marsal, Santiago
  • Torta, Joan Miquel
  • Curto, Juan José
  • Cid, Òscar
  • Ibañez, Miquel
Plain text files with magnetometer data (ASCII format) to monitor Geomagnetically Induced Currents (GIC) flowing in power transmission lines. Data from the magnetometer under transmission line contains GIC magnetic signal + environment magnetic field; data from reference magnetometer (hundreds of meters from the transmission line) contains only environment magnetic field. Subtraction allows isolating GIC signal., Data files with magnetic data from Differential Magnetometer Method (DMM) sites to monitor Geomagnetically Induced Currents (GIC) flowing in power transmission lines. 8 first-level sub-folders, each corresponding to a DMM site represented by a 3-letter code. 2 second-level sub-folders corresponding to the two magnetometers per site: one under power line (LIN); another acting as reference (REF)., Ministerio de Ciencia e Innovación: PID2020-113135RB-C32, PID2020-113135RB-C31, Peer reviewed