Metodologías de Exposición a Campos Electromagnéticos para Casos de Uso 5G

PID2020-115005RJ-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2020
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 9
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Biocompatible Low-Cost Antennas Over Flexible Substrates for IoT-Health Applications

  • Castelló-Palacios, Sergio|||0000-0003-4689-652X
  • Antonino Daviu, Eva|||0000-0002-0163-4561
  • Vila Jiménez, Antonio|||0000-0003-3730-3083
  • Vallés Lluch, Ana|||0000-0002-7896-8666
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
[EN] This paper presents a 10 GHz wearable antenna specifically designed for IoT-Health applications. Their main distinguishing features are its biocompatibility and flexibility, which are acquired by designing custom-made materials. Four custommade materials were designed and manufactured in order to compare the performance of the antenna according to the selected substrate. The study assesses the impact of these materials on critical parameters such as bandwidth, efficiency, and radiation patterns. This work includes both the simulations of the antenna behaviour based on the dielectric properties of the materials, and also the experimental results from the real measurements performed on manufactured antennas. Results contribute to the ongoing evolution of materials in antenna design, opening new possibilities for the advancement of communication solutions in healthcare applications., This research has been funded by Huawei Technologies at the iTEAMHuawei Joint Innovation Center. This work has also been funded by Ramon¿ y Cajal fellowship RYC2021-033207-I, by EMERGE-5G project PID2020- 115005RJ-I00 and by HEROE-6G CNS2023-143570 project, all funded by Agencia Estatal de Investigacion MCIN/AEI/10.13039/501100011033 and by ¿ European Union NextGenerationEU/PRTR. It has also been supported by Generalitat Valenciana under project MAOCOM-6G (MFA/2022/056).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Dual Evaluation and Spatial Analysis of RF-EMF Exposure in 5G: Theoretical Extrapolations and Direct Measurements

  • Najera, Alberto
  • Villaescusa-Tebar, Alvaro
  • Gonzalez-Rubio, Jesus
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
[EN] This study evaluates radiofrequency electromagnetic field (RF-EMF) exposure in 5G networks using a dual approach that combines theoretical extrapolations and direct measurements in diverse semiurban and urban environments, specifically on the campus of the Polytechnic University of Valencia. Measurements were conducted using personal exposimeters under active traffic conditions on the 5G network, complemented by a code-selective measurement system based on an R&S TSME6 scanner. This approach enabled the calculation of maximum theoretical exposure by detailed analysis of 5G signals and the capture of key parameters such as cell ID and beam indices at 16 representative points across the campus. For precise spatial visualization, Kriging interpolation techniques in ArcGIS were employed to generate continuous exposure maps illustrating the spatial distribution of RF-EMF in the study area. The results indicate that both the extrapolated theoretical values and measured levels align with the limits recommended by the ICNIRP, even under high data demand scenarios, supporting current safety assessments of 5G infrastructure regarding electromagnetic exposure. The correlation between theoretical and instantaneous exposures validates the applied methodology and its effectiveness in assessing exposure in diverse environments. This study provides a robust framework for future research and highlights the importance of continuous monitoring to ensure public safety during the deployment of new telecommunications infrastructure in urban areas. Bioelectromagnetics. 00:00-00, 2025. (c) 2025 Bioelectromagnetics Society., This study was supported by the EMERGE-5G project Ref. PID2020-115005RJ-I00, Ramon & Cajal fellowship RYC2021-033207-I, HEROE-6G project Ref. CNS2023-143570 granted all by the Spanish Agency for Research MCIN/AEI/10.13039/501100011033, European Union NextGenerationEU/PRTR, the Program Investigo (INVEST/2022/199), held by the Conselleria de Innovacibn, Universidades, Investigacibn y Sociedad Digital de la Generalitat Valenciana, funded by Next Generation EU within the framework Plan de Recuperacibn, Transformacibn y Resiliencia de Espana.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

In Vivo and Ex Vivo Dielectric Characterization of Human Tissues in the Abdominal Area at the Microwave Band

  • Micó-Rosa, Sergio
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Frasson, Matteo
  • Pons-Beltran, Vicente
[EN] The dielectric characterization of biological tissues is essential for different medical applications. Due to ethical constraints, comprehensive characterization of human tissues remains a significant challenge. There is a large database of measurements on animals, but limited research has been conducted in humans, especially at the abdominal area at in vivo conditions. This study presents an in-depth analysis of the dielectric properties of human abdominal tissues such as liver, small intestine, and fat, both in vivo and ex vivo. Measurements were conducted both in vivo and ex vivo, using the open-ended coaxial probe method within 0.5 - 26.5 GHz band. Both fat and small intestine tissues were measured at ex vivo and in vivo conditions, while liver was measured only under in vivo conditions. The obtained dielectric properties were analyzed for each tissue and scenario. Results are compared to other reported studies and 2-pole Cole-Cole model parameters are reported to allow reproducibility of the tissue behavior. These findings contribute to expanding the existing database on dielectric properties of human tissues, particularly for abdominal tissues in humans in vivo, of which there are few measurements in the literature., This work was supported in part by EMERGE-5G project under Grant PID2020-115005RJ-I00, in part by Ramon y Cajal Fellowship under Grant RYC2021-033207-I, in part by HEROE-6G project under Grant CNS2023-143570, in part by the Spanish Agency for Research under Grant MICIU/AEI/10.13039/501100011033, and in part by European Union NextGenerationEU/PRTR.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Tailored EM Materials for Millimeter-Wave Direct Ink Write Printed Antennas

  • Castelló-Palacios, Sergio|||0000-0003-4689-652X
  • Antonino Daviu, Eva|||0000-0002-0163-4561
  • Vila Jiménez, Antonio|||0000-0003-3730-3083
  • Vallés Lluch, Ana|||0000-0002-7896-8666
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
[EN] This paper presents the development of dielectric materials with tailored dielectric properties (electric permittivity and loss tangent) at Gigahertz frequencies for their use in low-cost millimeter-wave flexible Direct Ink Write (DIW) printed antennas. The materials can be created to exhibit specific mechanical properties (liquid, semi-solids, temperature-sensitivity, ink adhesion, flexibility, or stretchability) to cover different application needs. Electromagnetic performance of microstrip antennas manufactured through DIW technique on two crafted custom semi-solid materials will be presented for millimeter-wave applications. The antennas exhibit remarkable characteristics for 6G systems, particularly in terms of cost-effectiveness, owing to the low-cost fabrication process employed., This work was supported in part by the Institute of Telecommunications and Multimedia Applications (iTEAM)-Huawei Joint Innovation Center, Huawei Technologies; in part by the Ramón y Cajal Fellowship RYC2021-033207-I and the Metodologías de Exposición a Campos Electromagnéticos para Casos de Uso 5G (EMERGE-5G) Project funded by both Ministerio de Ciencia e Innovación/Agencia Estatal de Investigación, MCIN/AEI/10.13039/501100011033; and in part by the European Union NextGenerationEU/Plan de Recuperación, Recuperación, Transformación y Resiliencia (PRTR) under Grant PID2020-115005RJ-I00.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Initial Characterization of Healthy and Malignant in vivo and ex vivo Human Colon Tissues under Surgery Procedures

  • Micó-Rosa, Sergio
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
  • Frasson, Matteo
  • Pons-Beltrán, Vicente
  • López-Muñoz, Pedro
[EN] The dielectric characterization of human tissues can play a crucial role in the development of new medical diagnostic tools. In particular, the characterization of healthy and pathological tissues can provide vital information for diagnosis. In this paper, preliminary results from a small-scale measurement campaign conducted in 0.5¿26.5GHz during real surgeries on healthy and malignant human colon tissues are presented. Those measurements were carried out externally to the colon, without direct contact to the tumor growing inside the colon. Furthermore, different tumor stages are taken into account. Initial findings reveal that advanced tumor stages are related with increased higher values of dielectric properties in malignant tumor tissues compared to the healthy ones., This work was funded by the eSCOPE project funded by Hospital La Fe and Universitat Politecnica de Valencia, and by Program Investigo (INVEST/2022/199), held by the Conselleria de Innovacion, Universidades, Investigacion y Sociedad Digital de la Generalitat Valenciana, funded by Next Generation EU within the framework Plan de Recuperacion, Transformacion y Resiliencia de Espana. This work has been additionally funded by Ramon y Cajal fellowship RYC2021-033207-I, by EMERGE-5G project PID2020-115005RJ-I00, and by HEROE-6G CNS2023-143570 project, all funded by Agencia Estatal de Investigacion MCIN/AEI/10.13039/501100011033 and by European Union NextGenerationEU/PRTR.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Assessment of 5G RF-EMF Exposure During Large-Scale Public Events via Field Measurements

  • Villaescusa-Tébar, Álvaro
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
[EN] The development of Fifth-Generation (5G) mobile networks has raised public concern regarding human exposure to radiofrequency electromagnetic fields (RF-EMF). Key 5G features such as higher operating frequencies, broader bandwidths, beamforming, and traffic-dependent signal variability significantly influence RF-EMF exposure dynamics. Although many studies have assessed EMF levels induced by specific base stations under controlled user traffic, little empirical data are available on population-wide 5G environmental exposure across diverse scenarios. This study addresses this gap through field measurements conducted during a large public festival in Valencia, Spain and a baseline day prior to the event. Downlink signals from the 700 MHz and 3500 MHz 5G bands were measured across Spain's three main network operators. Five locations surrounding the event venue were selected to capture the influence of the measurement location, and two measurement durations (6 and 30 min) were compared to assess temporal dynamics. The results showed that during the event, the power density in the 3500 MHz band increased by up to a factor of eight compared to the baseline conditions. However, even the highest recorded exposure levels remained well below the international safety limits. Additionally, a 30-minute continuous measurement revealed an approximately 30% increase in average power density compared to a 6-minute snapshot. These findings confirm that 5G environmental RF-EMF exposure remains within safe limits, even under high-demand conditions, and underscore the relevance of considering measurement location and temporal variability in exposure assessments., This work was supported in part by the Electromagnetic Fields (EMF) Methodologies for 5G Use Cases (EMERGE-5G) Project underGrant PID2020-115005RJ-I00, in part by Ramon y Cajal Fellowship under Grant RYC2021-033207-I, and in part by Human-Friendly Radio Technologies for 5G/6G (HEROE-6G) Project, granted by the Spanish Agency for Research MICIU/AEI/10.13039/501100011033and the European Union NextGenerationEU/PRTR under Grant CNS2023-143570.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Deduction of Extrapolation Factors in Realistic Scenarios for In-Situ Assessment of 5G Base Stations

  • Villaescusa-Tébar, Álvaro
  • Roche-Peris, Jorge
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
[EN] Accurate assessment of electromagnetic field (EMF) exposure in 5G networks presents challenges due to beamforming and advanced technologies. Traditional frequency-selective methods provide actual exposure values but cannot distinguish beams or cells. Code-selective techniques differentiate cells and beams, but require complex extrapolation processes based on unavailable network parameters like beamforming patterns. This study investigates extrapolation factors like Fextbeam in realistic indoor and outdoor 5G environments, using frequency-selective and code-selective measurements. Measurements under different traffic conditions evaluated the effect of beam patterns and power. Results showed higher variability in extrapolated values due to differences in antenna radiation patterns. Outdoor environments exhibited more stable values, indicating the critical role of antenna patterns, especially indoors., This work has been funded by EMERGE-5G project Ref. PID2020-115005RJ-I00, by Ramon & Cajal fellowship RYC2021- 033207-I, and by HEROE-6G project Ref. CNS2023-143570 granted all by the Spanish Agency for Research MICIU/AEI/10.13039/501100011033 and by European Union NextGenerationEU/PRTR. This work was also supported in part by the European Commission under the SNS project IMAGINE-B5G (Advanced 5G Open Platform for Large Scale Trials and Pilots across Europe), grant number 101096452. This work was additionally supported by the Program Investigo (INVEST/2022/199), held by the Conselleria de Innovación, Universidades, Investigación y Sociedad Digital de la Generalitat Valenciana, funded by Next Generation EU within the framework Plan de Recuperación, Transformación y Resiliencia de España.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Bridging Nano and Body Area Networks: A Full Architecture for Cardiovascular Health Applications

  • Asorey-Cacheda, Rafael
  • Correia, Luis M.
  • Wojcik, Krzysztof
  • Turbic, Kenan
  • Kulakowski, Pawel
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
[EN] Cardiovascular events occurring in the bloodstream are responsible for about 40% of human deaths in developed countries. Motivated by this fact, we present a new global network architecture for a system for the diagnosis and treatment of cardiovascular events, focusing on problems related to pulmonary artery occlusion, i.e., situations of artery blockage by a blood clot. The proposed system is based on bio-sensors for detection of artery blockage and bio-actuators for releasing appropriate medicines, both types of devices being implanted in pulmonary arteries. The system can be used by a person leading an active life and provides bidirectional communication with medical personnel via nano-nodes circulating in the bloodstream constituting an in-body area network. We derive an analytical model for calculating the required number of nano-nodes to detect artery blockage and the probability of activating a bio-actuator. We also analyze the performance of the body area component of the system in terms of path loss and of wireless links budget. Results show that the system can diagnose a blocked artery in about 3 h and that after another 3-h medicines can be released in the exact spot of the artery occlusion, while with current medical practices the average time for diagnosis varies between 5 and 9 days., This work was supported in part by the COST Action INTERACT under Grant CA20120; in part by the Spanish Agency for Research MCIN/AEI/10.13039/501100011033 under Project PID2020-116329GB-C22, Project PID2020-115005RJ-I0, and Project TED2021-129336B-I00; and in part by the Polish Ministry of Science and Higher Education with the Subvention Funds of the Faculty of Computer Science, Electronics and Telecommunications of AGH University.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Instantaneous vs Theoretical Maximum Exposure Under Real Traffic Conditions: Example in the City of Valencia

  • Villaescusa-Tébar, Álvaro
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Najera, Alberto
  • Gonzalez-Rubio, Jesus
[EN] With the ongoing deployment of the fifth generation (5G) mobile telecommunications, there is an increasing need for standardized methodologies to assess human exposure to radiofrequency electromagnetic fields from 5G base stations. Thus, the development of proper assessment methodologies will impact the adequate deployment of 5G systems as well as ensure the safe operation of devices for people. This work focuses on comparing total exposure and theoretical maximum exposure levels in commercial 5G operational networks in the City of Valencia for the frequency band below 6 GHz. This study is based on results from measurements using a code-selective methodology as well as a personal exposimeter in addition to an omnidirectional antenna and one-user equipment (UE) to measure the downlink exposure in a real scenario., This work has been funded by EMERGE-5G project Ref. PID2020-115005RJ-I00 and by Ramon & Cajal fellowship RYC2021-033207-I granted both by the Spanish Agency for Research MCIN/AEI/ 10.13039/501100011033 and by European Union NextGenerationEU/PRTR. This work was additionally supported by the Program Investigo (INVEST/2022/199), held by the Conselleria de Innovación, Universidades, Investigación y Sociedad Digital de la Generalitat Valenciana, funded by Next Generation EU within the framework Plan de Recuperación, Transformación y Resiliencia de España.