Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Parametric Study and Experimental Validation of Acoustic Leaky Wave Antenna in Spatial Localization

  • Fernández-Garrido, Alejandro
  • Campo-Valera, María
  • Abdo-Sánchez, Elena
  • García-Sánchez, Antonio-Javier
  • Asorey-Cacheda, Rafael
  • Picó Vila, Rubén|||0000-0003-3537-9658
[EN] Acoustic signals, which have been utilized for decades in the spatial localization of objects, have found applications in fields as diverse as sonar for underwater navigation, communication, and object detection. Traditional methods often rely on arrays of transducers, which necessitate the use of expensive hardware and processing algorithms. An emerging alternative is the Acoustic LeakyWave Antenna (ALWA), which is inspired by electromagnetic leaky wave antennas. ALWA technology employs a single transducer to emit directional beams that scan angular space by frequency manipulation. Conventional arrays offer cost-effectiveness and simplicity of design, but ALWAs have the advantage of operating on the principle of energy leakage, which is achieved by various mechanisms, such as uniform apertures or slits periodic along the waveguide. This technology, applicable to underwater and airborne communications, offers compact and energy-efficient solutions, which facilitate the development of the "Underwater Internet of Things" and autonomous communication systems for underwater vehicles. This work presents a parametric study of this type of antennas with axisymmetric geometry by means of a numerical solution based on the Finite Element Method. Together with analytical studies, the physical phenomenology underlying this technology will be described, including directivity, transmission and reflection parameters, beam scanning and dispersion curve. Finally, the design is validated through experiments., This work was supported in part by the ThinkInAzul and AgroAlNext Programs funded by Ministerio de Ciencia, Innovación y Universidades (MICIU) with funding from European Union (EU) NextGenerationEU/Plan de Recuperación, Transformación y Resiliencia (PRTR)-C17.I1; in part by the Fundación Séneca with funding from Comunidad Autónoma Región de Murcia (CARM); in part by the MICIU/Agencia Estatal de Investigación (AEI)/10.13039/501100011033 under Grant PID2023-148214OB-C21, Grant TED2021-129336B-I00, Grant PID2022-141193OB-I00, and Grant PID2022-138321NB-C22; in part by the European Union NextGenerationEU/PRTR and Fondo Europeo de Desarrollo Regional (FEDER)/EU; and in part by the Fundación Séneca under Grant 22236/PDC/23.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Bridging Nano and Body Area Networks: A Full Architecture for Cardiovascular Health Applications

  • Asorey-Cacheda, Rafael
  • Correia, Luis M.
  • Wojcik, Krzysztof
  • Turbic, Kenan
  • Kulakowski, Pawel
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
[EN] Cardiovascular events occurring in the bloodstream are responsible for about 40% of human deaths in developed countries. Motivated by this fact, we present a new global network architecture for a system for the diagnosis and treatment of cardiovascular events, focusing on problems related to pulmonary artery occlusion, i.e., situations of artery blockage by a blood clot. The proposed system is based on bio-sensors for detection of artery blockage and bio-actuators for releasing appropriate medicines, both types of devices being implanted in pulmonary arteries. The system can be used by a person leading an active life and provides bidirectional communication with medical personnel via nano-nodes circulating in the bloodstream constituting an in-body area network. We derive an analytical model for calculating the required number of nano-nodes to detect artery blockage and the probability of activating a bio-actuator. We also analyze the performance of the body area component of the system in terms of path loss and of wireless links budget. Results show that the system can diagnose a blocked artery in about 3 h and that after another 3-h medicines can be released in the exact spot of the artery occlusion, while with current medical practices the average time for diagnosis varies between 5 and 9 days., This work was supported in part by the COST Action INTERACT under Grant CA20120; in part by the Spanish Agency for Research MCIN/AEI/10.13039/501100011033 under Project PID2020-116329GB-C22, Project PID2020-115005RJ-I0, and Project TED2021-129336B-I00; and in part by the Polish Ministry of Science and Higher Education with the Subvention Funds of the Faculty of Computer Science, Electronics and Telecommunications of AGH University.