Pasar al contenido principal

NANOMATERIALES AVANZADOS Y MICRODISPOSITIVOS AUTONOMOS INTELIGENTES PARA APLICACIONES BIOELECTRONICAS

PID2020-119350RA-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2020
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Biocompatibility and Electrical Stimulation of Skeletal and Smooth Muscle Cells Cultured on Piezoelectric Nanogenerators

  • Blanquer, Andreu
  • Careta, Oriol
  • Anido-Varela, Laura
  • Aranda, Aida
  • Ibáñez, Elena
  • Esteve, Jaume
  • Nogués, Carme
  • Murillo Rodríguez, Gonzalo
Nanogenerators are interesting for biomedical applications, with a great potential for electrical stimulation of excitable cells. Piezoelectric ZnO nanosheets present unique properties for tissue engineering. In this study, nanogenerator arrays based on ZnO nanosheets are fabricated on transparent coverslips to analyse the biocompatibility and the electromechanical interaction with two types of muscle cells, smooth and skeletal. Both cell types adhere, proliferate and differentiate on the ZnO nanogenerators. Interestingly, the amount of Zn ions released over time from the nanogenerators does not interfere with cell viability and does not trigger the associated inflammatory response, which is not triggered by the nanogenerators themselves either. The local electric field generated by the electromechanical nanogenerator-cell interaction stimulates smooth muscle cells by increasing cytosolic calcium ions, whereas no stimulation effect is observed on skeletal muscle cells. The random orientation of the ZnO nanogenerators, avoiding an overall action potential aligned along the muscle fibre, is hypothesised to be the cause of the cell-type dependent response. This demonstrates the need of optimizing the nanogenerator morphology, orientation and distribution according to the potential biomedical use. Thus, this study demonstrates the cell-scale stimulation triggered by biocompatible piezoelectric nanogenerators without using an external source on smooth muscle cells, although it remarks the cell type-dependent response., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Improved Performance of Biohybrid Muscle-Based Bio-Bots Doped with Piezoelectric Boron Nitride Nanotubes

  • Mestre, Rafael
  • Fuentes, Judith
  • Lefaix, Laura
  • Wang, Jiaojiao
  • Guix, Maria
  • Murillo Rodríguez, Gonzalo
  • Bashir, Rashid
  • Sánchez, Samuel
Biohybrid robots, or bio-bots, integrate living and synthetic materials following a synergistic strategy to acquire some of the unique properties of biological organisms, like adaptability or bio-sensing, which are difficult to obtain exclusively using artificial materials. Skeletal muscle is one of the preferred candidates to power bio-bots, enabling a wide variety of movements from walking to swimming. Conductive nanocomposites, like gold nanoparticles or graphene, can provide benefits to muscle cells by improving the scaffolds’ mechanical and conductive properties. Here, boron nitride nanotubes (BNNTs), with piezoelectric properties, are integrated in muscle-based bio-bots and an improvement in their force output and motion speed is demonstrated. A full characterization of the BNNTs is provided, and their piezoelectric behavior with piezometer and dynamometer measurements is confirmed. It is hypothesized that the improved performance is a result of an electric field generated by the nanocomposites due to stresses produced by the cells during differentiation. This hypothesis is backed with finite element simulations supporting that this stress can generate a non-zero electric field within the matrix. With this work, it is shown that the integration of nanocomposite into muscle-based bio-bots can improve their performance, paving the way toward stronger and faster bio-hybrid robots., R.M. thanks “la Caixa” Foundation through IBEC International PhD Programme la Caixa Severo Ochoa fellowships (code LCF/BQ/SO16/52270018 and UK Research and Innovation (UKRI) grant reference MR/S032711/1). M.G. thanks MINECO for the Juan de la Cierva fellowship (IJCI2016-30451), the Beatriu de Pinós Programme (2018-BP-00305), and the Ministry of Business and Knowledge of the Government of Catalonia. The research leading to these results has received funding from the grant RTI2018-098164-B-I00 funded by MICIN/AEI/10.13039/5011000110333 and by “FEDER Una manera de hacer Europa” (BOTSinFluids project), the CERCA program by the Generalitat de Catalunya, the Secretaria d'Universitats i Recerca del Departament d'Empresa i Coneixement de la Generalitat de Catalunya through the project 2017 SGR 1148, and the “Centro de Excelencia Severo Ochoa”, funded by Agencia Estatal de Investigación (CEX2018-000789-S). This project has also received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme (grant agreement No 866348; i-NanoSwarms). G.M. thanks La Caixa Foundation for the Junior Leader Retaining Fellowship program (LCF/BQ/ PR19/11700010) and MINECO for the Ramon y Cajal Fellowship (RYC2020-030501-I). This study was supported by the Agencia Estatal de Investigación from Spanish Government (PID2020-119350RA-I00, MICROBIO project) and the European Union - NextGenerationEU (EUR2020-112082, PIEZO2CELL). The work done at UIUC was funded by NSF EFRI C3 SoRo No. 1830881 and with support from the NSF Science and Technology Center Emergent Behavior of Integrated Cellular Systems (Grant No. CBET0939511)., With funding from the Spanish government through the "Severo Ochoa Centre of Excellence" accreditation (CEX2018-000789-S)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Piezoelectric MEMS resonator with magnetic tip mass for energy harvesting from ultra-low intensity magnetic fields

  • Duque, Marcos
  • Murillo Rodríguez, Gonzalo
This article addresses the limitation in the implementation of the Internet of Things (IoT) due to its energy dependence on batteries. The central focus of this work is the development and characterization of a magnetoelectric (ME) energy generator for IoT, which combines a piezoelectric microelectromechanical system (MEMS) with a magnetic mass to interact with ambient magnetic fields (MFs). The device's efficiency is validated through finite element modeling (FEM) simulations and electrical characterization. Its applicability in environments with residual magnetic fields, such as near common household appliances, highlights its viability. Specific results, such as a maximum generated power of 0.55 µW, corresponding to a power density of 9.19 µW/cm³, for a magnetic field strength of 5 µT, emphasize its ability to address energy challenges and promote the sustainable autonomy of IoT., Funding text 1 G. Murillo thanks the financial support from the La Caixa Foundation under the Junior Leader Retaining Fellowship (LCF/BQ/PR19/11700010), the national projects PID2020-119350RA-I00, EUR2020-112082 and CNS2022-136065, under the Dynamization Actions \"Europa Excelencia 2020\u201D and the Consolidation Actions funded by the NextGenerationEU Instrument and Ramon y Cajal Fellowship 2020 (RYC2020-030501-I). This work has been carried out in collaboration with ENERGIOT DEVICES SL (www.energiot.com), who holds part of the intellectual property and is funded by the European Union under the Silicon Eurocluster project (101074552), and in the framework of the doctoral program in Electronic and Telecommunication Engineering of the Autonomous University of Barcelona. Funding text 2 G. Murillo thanks the financial support from the La Caixa Foundation under the Junior Leader Retaining Fellowship (LCF/BQ/PR19/11700010), the national projects PID2020-119350RA-I00, EUR2020-112082 and CNS2022-136065, under the Dynamization Actions \"Europa Excelencia 2020\u201D and the Consolidation Actions funded by the NextGenerationEU Instrument and Ramon y Cajal Fellowship 2020 (RYC2020-030501-I). This work has been carried out in collaboration with ENERGIOT DEVICES SL ( www.energiot.com ), who holds part of the intellectual property, and in the framework of the doctoral program in Electronic and Telecommunication Engineering of the Autonomous University of Barcelona., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Replication data for Piezoelectric MEMS resonator with magnetic tip mass for energy harvesting from ultra-low intensity magnetic fields

  • Duque, Marcos
  • Murillo Rodríguez, Gonzalo
This article addresses the limitation in the implementation of the Internet of Things (IoT) due to its energy dependence on batteries. The central focus of this work is the development and characterization of a magnetoelectric (ME) energy generator for IoT, which combines a piezoelectric microelectromechanical system (MEMS) with a magnetic mass to interact with ambient magnetic fields (MFs). The device's efficiency is validated through finite element modeling (FEM) simulations and electrical characterization. Its applicability in environments with residual magnetic fields, such as near common household appliances, highlights its viability. Specific results, such as a maximum generated power of 0.55 µW, corresponding to a power density of 9.19 µW/cm³, for a magnetic field strength of 5 µT, emphasize its ability to address energy challenges and promote the sustainable autonomy of IoT., Funding text 1 G. Murillo thanks the financial support from the La Caixa Foundation under the Junior Leader Retaining Fellowship (LCF/BQ/PR19/11700010), the national projects PID2020-119350RA-I00, EUR2020-112082 and CNS2022-136065, under the Dynamization Actions \"Europa Excelencia 2020\u201D and the Consolidation Actions funded by the NextGenerationEU Instrument and Ramon y Cajal Fellowship 2020 (RYC2020-030501-I). This work has been carried out in collaboration with ENERGIOT DEVICES SL (www.energiot.com), who holds part of the intellectual property and is funded by the European Union under the Silicon Eurocluster project (101074552), and in the framework of the doctoral program in Electronic and Telecommunication Engineering of the Autonomous University of Barcelona. Funding text 2 G. Murillo thanks the financial support from the La Caixa Foundation under the Junior Leader Retaining Fellowship (LCF/BQ/PR19/11700010), the national projects PID2020-119350RA-I00, EUR2020-112082 and CNS2022-136065, under the Dynamization Actions \"Europa Excelencia 2020\u201D and the Consolidation Actions funded by the NextGenerationEU Instrument and Ramon y Cajal Fellowship 2020 (RYC2020-030501-I). This work has been carried out in collaboration with ENERGIOT DEVICES SL ( www.energiot.com ), who holds part of the intellectual property, and in the framework of the doctoral program in Electronic and Telecommunication Engineering of the Autonomous University of Barcelona., No
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Tailoring Piezoelectric Nanogenerators and Microdevices for Cellular Excitation: Impact of Size and Morphology

  • Lefaix, Laura
  • Navarro, Marc
  • Nogués, Carme
  • Blanquer, Andreu
  • Murillo, Gonzalo
The use of piezoelectric devices as wireless electrical stimulators is an emerging research topic. In this study, piezoelectric microdevices, consisting of ZnO nanosheets (NSs) functioning as piezoelectric nanogenerators (NGs) grown on top of silicon microparticles, to electrically stimulate cell are designed. The morphology of the ZnO NSs is optimized by tuning the thickness of the aluminum nitride (AlN) catalyst layer and adjusting the growth duration. ZnO NSs grown on thinner AlN layers (≤ 200 nm) and subjected to 9 h of hydrothermal growth exhibit the most suitable characteristics for cell stimulation, balancing crystal size, and electric field generation. The generation of a local electric field capable of exciting osteoblast cells is inferred from finite element simulations and intracellular calcium influx measurements. The internalization rate of silicon microdevices of varying sizes (3 × 3, 6 × 10, 12 × 18 µm2) by osteosarcoma (Saos-2) and primary human osteoblast (hOB) cells is assessed. The results show that smaller devices have higher internalization rates, particularly in tumoral Saos-2 cells, while primary cells exhibit minimal internalization (< 10%) across all particle sizes. This study presents an optimized piezoelectric microdevice, based on a scalable and customizable fabrication process, for minimally invasive bioelectronic applications, offering accurate electrical cell stimulation while minimizing unwanted internalization., L. L. would like to thank CSIC for the funding obtained through the JAE Intro 2019 and JAE Intro ICUs (BOE-A-2007-14853) programs. This work was carried out within the framework of the Ph.D. program in Biotechnol- ogy of the Universitat Autònoma de Barcelona (UAB). A.B. received fund-ing from a postdoctoral fellowship within the Beatriu de Pinós program, funded by the Secretary of Universities and Research (Government of Cat- alonia) and by the Horizon 2020 program of research and innovation of the European Union under Marie Sklodowska-Curiegrant agreement No. 801370. G. M. thanks the La Caixa Foundation for the Junior Leader Retain-ing Fellowship program (LCF/BQ/ PR19/11700010) and MINECO for the Ramon y Cajal Fellowship (RYC2020-030501-I). This work was supported by the Agencia Estatal de Investigación from the Spanish Government (PID2023-148047OB-C21, PID2023-148047OA-C22, PID2020-119350RA-I00 and ID2020-116844RB-C21), and from the European Union under the Dynamization Actions Europa Excelencia 2020 funded by NextGen-erationEU Instrument (EUR2020-112082, PIEZO2CELL). This work also received additional support from Generalitat de Catalunya-AGAUR (2021 SGR 00497 and 2021-SGR-00122). Finally, we also want to acknowledge all the efforts of the staff at IMB-CNM (CSIC), especially the cleanroom engineers, and the staff of the Servei de Microscòpia de la Universitat Autònoma de Barcelona., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Controlled poling of a fully printed piezoelectric PVDF-TrFE device as a multifunctional platform with inkjet-printed silver electrodes

  • Alique, Marc
  • Moya, Ana
  • Kreuzer, Martin
  • Lacharmoise, Paul
  • Murillo, Gonzalo
  • Simao, Claudia Delgado
Fully printed piezoelectric devices are important components for seamlessly integrated circuits. Herein, for the first time, inkjet-printed silver electrodes on a screen-printed PVDF-TrFE polymer on a flexible film are reported. Studies on different inks and printing conditions are performed to select and prepare bottom and top inkjet-printed electrodes on the screen-printed PVDF-TrFE layer. Thermal-assisted electrical poling and unpoling conditions for the device are obtained, with high reproducibility and reversibility in multiple cycles. The fully printed device is investigated as a sensor, an actuator, and an energy harvester as a single device multifunctional platform. A maximum output voltage of 3.6 V is achieved in piezoelectric devices when used as a vibrational sensor. The maximum output power of 1.6 μW with a 1.1 MΩ optimum load resistor was obtained when clamped as a cantilever and accelerated at 0.75 G and characterized as a microgenerator., M. Alique is a fellow of the Eurecat “Vicente Lopez” PhD grant program. This work was financially supported by the Catalan Government through the funding grant ACCIÓ-Eurecat. This work has been carried out within the framework of the doctoral program in Electrical and Telecommunications Engineering of the Universitat Autònoma de Barcelona Eurecat thanks the NOVACENTRIX for the support with the photonic curing equipment. G. Murillo thanks the financial support from the La Caixa Foundation under the Junior Leader Retaining Fellowship (LCF/BQ/PR19/11700010), microbio (PID2020-119350RA-I00) and piezo2cell (EUR2020-112082) funded by MCIN/AEI/10.13039/501100011033 and European Union “NextGenerationEU”/PRTR”. The FTIR experiments were performed at the MIRAS beamline at ALBA Synchrotron with the collaboration of the ALBA staff., Peer reviewed
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Biocompatibility and Electrical Stimulation of Skeletal and Smooth Muscle Cells Cultured on Piezoelectric Nanogenerators

  • Blanquer, Andreu|||0000-0002-3551-1885
  • Careta, Oriol|||0000-0003-1333-0300
  • Anido-Varela, Laura
  • Aranda, Aida
  • Ibáñez, Elena|||0000-0002-0275-6958
  • Esteve, Jaume|||0000-0001-9440-7984
  • Nogués, Carme|||0000-0002-6361-8559
  • Murillo, Gonzalo|||0000-0002-0368-1900
Nanogenerators are interesting for biomedical applications, with a great potential for electrical stimulation of excitable cells. Piezoelectric ZnO nanosheets present unique properties for tissue engineering. In this study, nanogenerator arrays based on ZnO nanosheets are fabricated on transparent coverslips to analyse the biocompatibility and the electromechanical interaction with two types of muscle cells, smooth and skeletal. Both cell types adhere, proliferate and differentiate on the ZnO nanogenerators. Interestingly, the amount of Zn ions released over time from the nanogenerators does not interfere with cell viability and does not trigger the associated inflammatory response, which is not triggered by the nanogenerators themselves either. The local electric field generated by the electromechanical nanogenerator-cell interaction stimulates smooth muscle cells by increasing cytosolic calcium ions, whereas no stimulation effect is observed on skeletal muscle cells. The random orientation of the ZnO nanogenerators, avoiding an overall action potential aligned along the muscle fibre, is hypothesised to be the cause of the cell-type dependent response. This demonstrates the need of optimizing the nanogenerator morphology, orientation and distribution according to the potential biomedical use. Thus, this study demonstrates the cell-scale stimulation triggered by biocompatible piezoelectric nanogenerators without using an external source on smooth muscle cells, although it remarks the cell type-dependent response.