Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Study of Full-Color Multiplexed Transmission Holograms of Diffusing Objects Recorded in Photopolymer Bayfol HX

  • Sevilla, Marina
  • Chemisana Villegas, Daniel
  • Atencia Carrizo, Jesús
  • Marín Sáez, Julia
A wavelength multiplexing procedure for color transmission volume holograms of diffusing objects recorded in Bayfol® HX200 photopolymer is proposed. For the recording, three lasers of 442 nm, 532 nm and 633 nm, and a Spectralon® diffusing object were used for monochromatic and polychromatic calibration. Monochromatic calibration shows that the maximum index modulation obtained for each wavelength was not enough to give 100% efficiency, although the efficiency values achieved in the case of monochromatic recordings with diffusing objects were high, at around 90% for 633 nm and 532 nm recordings, and 60% for 442 nm. The efficiency values obtained for multiplexed holograms were 19.1% for the 442 nm hologram, 25.9% for the 532 nm hologram and 15.2% for the 633 nm., This research was funded by the “Diputación General de Aragón-Fondo Social Europeo” (TOL research group, E44_17R), the “Generalitat de Catalunya” (2017FI_B2_00127 and 2017 SGR 1276) and the “Ministerio de Ciencia e Innovación” (PID2019-108598GB-I00, PID2019-111536RB-I00 and PID2021-114311RA-I00)
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Study of full-color multiplexed transmission holograms of diffusing objects recorded in photopolymer bayfol hx

  • Sevilla, M.
  • Marín-Sáez, J.
  • Chemisana, D.
  • Collados, M.V.
  • Atencia, J.
A wavelength multiplexing procedure for color transmission volume holograms of diffusing objects recorded in Bayfol® HX200 photopolymer is proposed. For the recording, three lasers of 442 nm, 532 nm and 633 nm, and a Spectralon® diffusing object were used for monochromatic and polychromatic calibration. Monochromatic calibration shows that the maximum index modulation obtained for each wavelength was not enough to give 100% efficiency, although the efficiency values achieved in the case of monochromatic recordings with diffusing objects were high, at around 90% for 633 nm and 532 nm recordings, and 60% for 442 nm. The efficiency values obtained for multiplexed holograms were 19.1% for the 442 nm hologram, 25.9% for the 532 nm hologram and 15.2% for the 633 nm.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Study of Full-Color Multiplexed Transmission Holograms of Diffusing Objects Recorded in Photopolymer Bayfol HX

  • Sevilla, Marina
  • Chemisana Villegas, Daniel
  • Atencia Carrizo, Jesús
  • Marín Sáez, Julia
A wavelength multiplexing procedure for color transmission volume holograms of diffusing objects recorded in Bayfol® HX200 photopolymer is proposed. For the recording, three lasers of 442 nm, 532 nm and 633 nm, and a Spectralon® diffusing object were used for monochromatic and polychromatic calibration. Monochromatic calibration shows that the maximum index modulation obtained for each wavelength was not enough to give 100% efficiency, although the efficiency values achieved in the case of monochromatic recordings with diffusing objects were high, at around 90% for 633 nm and 532 nm recordings, and 60% for 442 nm. The efficiency values obtained for multiplexed holograms were 19.1% for the 442 nm hologram, 25.9% for the 532 nm hologram and 15.2% for the 633 nm., This research was funded by the “Diputación General de Aragón-Fondo Social Europeo” (TOL research group, E44_17R), the “Generalitat de Catalunya” (2017FI_B2_00127 and 2017 SGR 1276) and the “Ministerio de Ciencia e Innovación” (PID2019-108598GB-I00, PID2019-111536RB-I00 and PID2021-114311RA-I00)