Pasar al contenido principal

DESARROLLO Y CARACTERIZACION DE BIORREACTORES BASADOS EN H2 Y HERRAMIENTAS DE MONITORIZACION AVANZADAS PARA LA VALORIZACION DE C Y S A PARTIR DE CORRIENTES LIQUIDAS Y GASEOSAS

PID2021-126253OB-C21

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2021
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD AUTONOMA DE BARCELONA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 10
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo de revisión (ReviewArticle)

An overview of biomethanation and the use of membrane technologies as a candidate to overcome H2 mass transfer limitations

  • Fachal Suarez, Manuel|||0000-0002-4244-6831
  • Krishnan, Santhana
  • Chaiprapat, Sumate
  • González, Daniel|||0000-0003-0128-6445
  • Gabriel, David|||0000-0002-7713-4192
Energy produced from renewable sources such as sun or wind are intermittent, depending on circumstantial factors. This fact explains why energy supply and demand do not match. In this context, the interest in biomethanation has increased as an interesting contribution to the Power-to-gas concept (P2G), transforming the extra amount of produced electricity into methane (CH4). The reaction between green hydrogen (H2) (produced by electrolysis) and CO2 (pollutant present in biogas) can be catalysed by different microorganisms to produce biomethane, that can be injected into existing natural gas grid if reaching the standards. Thus, energy storage for both hydrogen and electricity, as well as transportation problems would be solved. However, H2 diffusion to the liquid phase for its further biological conversion is the main bottleneck due to the low solubility of H2. This review includes the state-of-the-art in biological hydrogenotrophic methanation (BHM) and membrane-based technologies. Specifically, the use of hollow-fiber membrane bioreactors as a technology to overcome H2 diffusion limitations is reviewed. Furthermore, the influence of operating conditions, microbiology, H2 diffusion and H2 injection methods are critically discussed before setting the main recommendations about BHM.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Development and Application of a 3D-Printed Microfluidic Sulfide-Selective Sensor for Online Monitoring of a Hydrogenotrophic Sulfidogenic Bioreactor

  • Cueto, David|||0000-0003-0916-9788
  • Baeza, Juan Antonio|||0000-0003-1290-1669
  • Gabriel, David|||0000-0002-7713-4192
  • Baeza, Mireia|||0000-0002-2240-6410
A sulfide online-monitoring system (S-OMS) was developed using a 3D-printed microfluidic platform to monitor sulfide in bioreactors. The S-OMS consisted of an electrochemical cell in which a microdevice was 3D-printed with co-polyester filaments and used an internal silver/silver sulfide (Ag/AgS) working electrode and a commercial, external silver/silver chloride (Ag/AgCl) reference electrode. The analytical evaluation showed a wide linear range (1.5-30,400 mg L) with repeatability and reproducibility presenting relative standard deviations of less than 5%. The S-OMS remained stable during working periods ranging from 16 h to 8 days, depending on the operation mode. Real samples from a sulfate-reducing bioreactor were used to validate the S-OMS, and the results were compared with those of a commercial sulfide ion-selective electrode (S-ISE), yielding a good linear correlation (R = 0.92). Moreover, a t-test revealed no significant statistical difference between the two analytical methods. The bioreactor operation resulted in a high sulfate reduction rate and in the accumulation of total sulfide, as measured with the S-OMS, in the bioreactor. However, the HS inhibition was offset by an increase in pH and volatile suspended solids (VSS) throughout the operation. Overall, the S-OMS demonstrated robust analytical performance and operational suitability for online monitoring of sulfide in sulfide-producing bioreactors.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

3D-printed sensing platforms and their feasibility for environmental monitoring

  • Pan, Mingyue|||0009-0000-0074-7006
  • Paré Estalella, Franc|||0000-0002-0710-3681
  • Baeza, Mireia|||0000-0002-2240-6410
After a brief introduction of the state of the art in environmental monitoring and 3D-printing technology, this review presents a general summary report about the most relevant electrochemical sensors fabricated by 3D-printing during the past five years. Being mainly applied in environmental monitoring, food industry and healthcare and pharmaceutical industry, the printing design, choice of electrode modification and analytical performance of those sensors are compared and discussed. Furthermore, to gain a better understanding about the achievements and limitations of the electrochemical sensors designed for environmental monitoring, a more detailed analysis is carried out by mainly focusing on water pollution detection and quality monitoring. Finally, to take better advantage of 3D-printing, the possible improvements and the future of further applying this technique into the environmental monitoring section is also discussed.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Electrochemical biosensor for aerobic acetate detection

  • Forner, E.
  • Ezenarro, J.J.
  • Pérez-Montero, M.
  • Vigués, N.
  • Asensio-Grau, Andrea
  • Mas, J.
  • Baeza, M.
  • Muñoz-Berbel, X.
  • Villa, R.
  • Gabriel, G.
  • Andrés Grau, Ana María|||0000-0002-6132-3167
[EN] There is an increasing demand on alternatives methods to animal testing. Numerous health parameters have been already studied using in vitro devices able to mimic the essential functions of the organs, being the real-time monitoring and response to stimuli their main limitations. Regarding the health of the gut, the short chain fatty acids, and particularly acetate, have emerged as key biomarkers to evaluate gut healthiness and disease development, although the number of acetate biosensors is still very low. This article presents a microbial biosensor based on fully biocompatible materials which is able to detect acetate in aerobic conditions in the range between 11 and 50 mM, and without compromising the viability and function of either bacteria (>90% viability) or mammalian cells (>80% viability). The detection mechanism is based on the metabolism of acetate by Escherichia coli bacteria immobilized on the transducer surface. Ferricyanide is used as a redox mediator to transfer electrons from the acetate metabolism in the bacterial cells to the transducer. High bacterial concentrations are immobilized in the transducer surface (109 cfu mL-1) by electrodeposition of conductive alginate hydrogels doped with reduced graphene oxide. The results show successful outcomes to exploit bacteria as a biosensing tool, based on the use of inkjet printed transducers, biocompatible materials and cell entrapment technologies., The authors acknowledge the support from the Ministerio de Ciencia Innovacion y Universidades (MICIU/FEDER, EU) , in Spain, through GUMICHIP (RTI2018-096786-B-I00) , GALILEI (PID2021-126253OB-C21) and CHIP4CELL projects (PID2021-127653NB-C21) and the support of the Generalitat de Catalunya to 2021SGR00495. The work has been performed by the ICTS "NANBIOSIS", more specifically by the U8 Unit of the CIBER in Bioengineering, Biomaterials & Nanomedicine (CIBER-BBN) at the IMB-CNM (CSIC) . This work also made use of theSpanish ICTS Network MICRONANOFABS partially supported by MEINCOM. We would like to thank the members of the GENOCOV research group from Universitat Autonoma, specifically Dr. D. Gabriel and PhD student M. Fachal, for their assistance in the liquid chroma-tography analysis presented in this work.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Novel Nitrate Ion-Selective Microsensor Fabricated by Means of Direct Ink Writing

  • Paré, Franc
  • Visús, Aida
  • Gabriel, Gemma
  • Baeza, Mireia
In this work, the stability, electrical conductivity, and versatility of graphite-based inks were taken advantage of to fabricate a nitrate potentiometric sensor. One other key property that was exploited for the design of an ion-selective electrode was the hydrophobicity of graphite. This prevented the formation of a water layer between the solid contact and the polymeric selective membrane. Moreover, given the use of printing technologies for electrode fabrication, it was possible to easily miniaturize the sensors and achieve lower fabrication costs. In this article, a printed sensor, composed of a graphite working electrode and a Ag/AgCl reference electrode, is presented and thoroughly characterized. The working electrode was modified with a well-known PVC-ionophore membrane, and the reference electrode was protected with a PVB-NaCl saturated membrane. It showed almost-Nernstian sensitivity of −(55.4 ± 0.7) mV/dec to NO3−, stability of up to 25 days of operation, limit of detection of 0.204 ± 0.009 mM, and repeatability of 99.02 % (N = 3). Coupled with its high selectivity compared with other anions, this low-cost, mass-producible sensor is a great alternative for environmental and industrial applications., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Feasible H2S Sensing in Water with a Printed Amperometric Microsensor

  • Paré, Franc
  • Castro, Rebeca
  • Gabriel, David
  • Guimerà, Xavier
  • Gabriel, Gemma
  • Baeza, Mireia
Concern over pollution has led to an increase in wastewater treatment systems, which require constant monitorization. In particular, hydrogen sulfide (H2S) is a toxic gas, soluble in water, commonly found in industrial and urban effluents. For proper removal control, fast, durable, and easy-to-handle analytical systems, capable of on-line measurements, such as electrochemical sensors, are required. Moreover, for a proper monitoring of said treatment processes, analysis must be carried out through all steps, thus needing for an economic and highly reproducible method of sensor fabrication. Digital printing have risen in the last few years as technologies capable of mass producing miniaturized electronical devices, allowing for the fabrication of amperometric sensors. Here, a 2 mm2 graphite (Gr) electrode, modified with different dispersions of single-walled carbon nanotubes (SWCNTs), poly(vinyl alcohol), poly(diallyl dimethylammonium chloride), and polylactic acid (PLA), is presented as a H2S sensor. SWCNTs allow for lower oxidation potentials, higher sensitivity, and a reduced rate of sulfur poisoning, while polymer dispersion of PLA increases mechanical stability and as a result, electrochemical performance. This microsensor presents an optimal pH working range between 7.5 and 11.0, a limit of detection of 4.3 μM, and the capacity to operate on complex matrices for H2S contamination detection., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Electrochemical biosensor for aerobic acetate detection

  • Forner, E
  • Ezenarro, J J
  • Pérez-Montero, M
  • Vigués, N
  • Asensio-Grau, A
  • Borges, Andrés A.
  • Mas, J
  • Baeza, M
  • Muñoz-Berbel, Xavier
  • Villa, Rosa
  • Gabriel, Gemma
There is an increasing demand on alternatives methods to animal testing. Numerous health parameters have been already studied using in vitro devices able to mimic the essential functions of the organs, being the real-time monitoring and response to stimuli their main limitations. Regarding the health of the gut, the short chain fatty acids, and particularly acetate, have emerged as key biomarkers to evaluate gut healthiness and disease development, although the number of acetate biosensors is still very low. This article presents a microbial biosensor based on fully biocompatible materials which is able to detect acetate in aerobic conditions in the range between 11 and 50 mM, and without compromising the viability and function of either bacteria (>90% viability) or mammalian cells (>80% viability). The detection mechanism is based on the metabolism of acetate by Escherichia coli bacteria immobilized on the transducer surface. Ferricyanide is used as a redox mediator to transfer electrons from the acetate metabolism in the bacterial cells to the transducer. High bacterial concentrations are immobilized in the transducer surface (109 cfu mL-1) by electrodeposition of conductive alginate hydrogels doped with reduced graphene oxide. The results show successful outcomes to exploit bacteria as a biosensing tool, based on the use of inkjet printed transducers, biocompatible materials and cell entrapment technologies., The authors acknowledge the support from the Ministerio de Ciencia Innovacion y Universidades (MICIU/FEDER, EU), in Spain, through GUMICHIP (RTI2018-096786-B-I00), GALILEI (PID2021-126253OB-C21) and CHIP4CELL projects (PID2021-127653NB-C21) and the support of the Generalitat de Catalunya to 2021SGR00495. The work has been performed by the ICTS “NANBIOSIS”, more specifically by the U8 Unit of the CIBER in Bioengineering, Biomaterials & Nanomedicine (CIBER-BBN) at the IMB-CNM (CSIC). This work also made use of the Spanish ICTS Network MICRONANOFABS partially supported by MEINCOM. We would like to thank the members of the GENOCOV research group from Universitat Autonoma, specifically Dr. D. Gabriel and PhD student M. Fachal, for their assistance in the liquid chromatography analysis presented in this work., Peer reviewed
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Novel Nitrate Ion-Selective Microsensor Fabricated by Means of Direct Ink Writing

  • Paré Estalella, Franc|||0000-0002-0710-3681
  • Visús, Aida
  • Gabriel, Gemma|||0000-0003-2140-6299
  • Baeza, Mireia|||0000-0002-2240-6410
In this work, the stability, electrical conductivity, and versatility of graphite-based inks were taken advantage of to fabricate a nitrate potentiometric sensor. One other key property that was exploited for the design of an ion-selective electrode was the hydrophobicity of graphite. This prevented the formation of a water layer between the solid contact and the polymeric selective membrane. Moreover, given the use of printing technologies for electrode fabrication, it was possible to easily miniaturize the sensors and achieve lower fabrication costs. In this article, a printed sensor, composed of a graphite working electrode and a Ag/AgCl reference electrode, is presented and thoroughly characterized. The working electrode was modified with a well-known PVC-ionophore membrane, and the reference electrode was protected with a PVB-NaCl saturated membrane. It showed almost-Nernstian sensitivity of -(55.4 ± 0.7) mV/dec to NO , stability of up to 25 days of operation, limit of detection of 0.204 ± 0.009 mM, and repeatability of 99.02 % (N = 3). Coupled with its high selectivity compared with other anions, this low-cost, mass-producible sensor is a great alternative for environmental and industrial applications.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Feasible HS Sensing in Water with a Printed Amperometric Microsensor

  • Paré Estalella, Franc|||0000-0002-0710-3681
  • Castro, Rebeca
  • Gabriel, David|||0000-0002-7713-4192
  • Guimerà Villalba, Xavier|||0000-0002-4156-2988
  • Gabriel, Gemma|||0000-0003-2140-6299
  • Baeza, Mireia|||0000-0002-2240-6410
Concern over pollution has led to an increase in wastewater treatment systems, which require constant monitorization. In particular, hydrogen sulfide (H2S) is a toxic gas, soluble in water, commonly found in industrial and urban effluents. For proper removal control, fast, durable, and easy-to-handle analytical systems, capable of on-line measurements, such as electrochemical sensors, are required. Moreover, for a proper monitoring of said treatment processes, analysis must be carried out through all steps, thus needing for an economic and highly reproducible method of sensor fabrication. Digital printing have risen in the last few years as technologies capable of mass producing miniaturized electronical devices, allowing for the fabrication of amperometric sensors. Here, a 2 mm2 graphite (Gr) electrode, modified with different dispersions of single-walled carbon nanotubes (SWCNTs), poly(vinyl alcohol), poly(diallyl dimethylammonium chloride), and polylactic acid (PLA), is presented as a H2S sensor. SWCNTs allow for lower oxidation potentials, higher sensitivity, and a reduced rate of sulfur poisoning, while polymer dispersion of PLA increases mechanical stability and as a result, electrochemical performance. This microsensor presents an optimal pH working range between 7.5 and 11.0, a limit of detection of 4.3 μM, and the capacity to operate on complex matrices for H2S contamination detection.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Multi-compartmentalized electrochemical sensing platforms for monitoring cascade enzymatic reactions

  • López Fernández, Laia|||0000-0003-0033-8231
  • Bastos Arrieta, Julio|||0000-0002-8939-6253
  • Appelhans, Dietmar|||0000-0003-4611-8963
  • Zhou, Yang
  • Moreno Pinilla, Silvia|||0000-0003-3710-8608
  • Palet, Cristina|||0000-0002-7467-613X
  • Baeza, Mireia|||0000-0002-2240-6410
Designing an electrochemical biosensor with the required features is a complex process involving multiple factors. For instance, nanocomposite materials used ensure the adaptation of the sensor to specific parameters on demand. But beyond making more versatile sensors, these materials likely offer excellent sensing platforms to mimic biological processes (e.g. cell communication) on the electrode surface. For this, developed methods are needed to integrate non-conductive nanoreactors for molecular communication into a biocompatible matrix on electrode surfaces with the request of spatially separated and controlled enzyme localization. Here, we present a novel reduced graphene oxide hybrid material to immobilize polymeric nanoreactors supported by an alginate network as a matrix on the electrode surface. The possibility of introducing cascade reactions in an electrochemical biosensor has the advantage of broadening the target substrates as well as their selectivity using enzymes in different nanocompartments (=compartmentalization). The polymeric vesicles allow the loading of enzymes or artificial enzymes, offering active center retention and long-term enzyme stability. Firstly, the inclusion of spatially separated polymeric active nanocompartments into the matrix on the electrode surface is used to monitor a simple enzyme reaction. However, the study's accomplishment lies in its successful ability to monitor an enzyme cascade reaction, one producing and the other consuming hydrogen peroxide, hosting natural and artificial enzymes. This proof-of-concept generates an important contribution to the design of analytical platforms capable of detecting complex environments or even monitoring communication between cell-like structures, extremely useful for fields such as synthetic biology, biomimetics and advanced biosensors.