Pasar al contenido principal

GUT-MICROBIOTA-ON CHIP FOR PRECISION MEDICINE

RTI2018-096786-B-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2018
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 14
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Electrochemical biosensor for aerobic acetate detection

  • Forner, E.
  • Ezenarro, J.J.
  • Pérez-Montero, M.
  • Vigués, N.
  • Asensio-Grau, Andrea
  • Mas, J.
  • Baeza, M.
  • Muñoz-Berbel, X.
  • Villa, R.
  • Gabriel, G.
  • Andrés Grau, Ana María|||0000-0002-6132-3167
[EN] There is an increasing demand on alternatives methods to animal testing. Numerous health parameters have been already studied using in vitro devices able to mimic the essential functions of the organs, being the real-time monitoring and response to stimuli their main limitations. Regarding the health of the gut, the short chain fatty acids, and particularly acetate, have emerged as key biomarkers to evaluate gut healthiness and disease development, although the number of acetate biosensors is still very low. This article presents a microbial biosensor based on fully biocompatible materials which is able to detect acetate in aerobic conditions in the range between 11 and 50 mM, and without compromising the viability and function of either bacteria (>90% viability) or mammalian cells (>80% viability). The detection mechanism is based on the metabolism of acetate by Escherichia coli bacteria immobilized on the transducer surface. Ferricyanide is used as a redox mediator to transfer electrons from the acetate metabolism in the bacterial cells to the transducer. High bacterial concentrations are immobilized in the transducer surface (109 cfu mL-1) by electrodeposition of conductive alginate hydrogels doped with reduced graphene oxide. The results show successful outcomes to exploit bacteria as a biosensing tool, based on the use of inkjet printed transducers, biocompatible materials and cell entrapment technologies., The authors acknowledge the support from the Ministerio de Ciencia Innovacion y Universidades (MICIU/FEDER, EU) , in Spain, through GUMICHIP (RTI2018-096786-B-I00) , GALILEI (PID2021-126253OB-C21) and CHIP4CELL projects (PID2021-127653NB-C21) and the support of the Generalitat de Catalunya to 2021SGR00495. The work has been performed by the ICTS "NANBIOSIS", more specifically by the U8 Unit of the CIBER in Bioengineering, Biomaterials & Nanomedicine (CIBER-BBN) at the IMB-CNM (CSIC) . This work also made use of theSpanish ICTS Network MICRONANOFABS partially supported by MEINCOM. We would like to thank the members of the GENOCOV research group from Universitat Autonoma, specifically Dr. D. Gabriel and PhD student M. Fachal, for their assistance in the liquid chroma-tography analysis presented in this work.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Mechanochromic Detection for Soft Opto-Magnetic Actuators

  • Güell-Grau, Pau
  • Escudero, Pedro
  • Giannis Perdikos, Filippos
  • López-Barbera, José Francisco
  • Pascual-Izarra, C.
  • Villa, Rosa
  • Nogués, Josep
  • Sepúlveda, Borja
  • Álvarez, Mar
New multi-stimuli responsive materials are required in smart systems applications to overcome current limitations in remote actuation and to achieve versatile operation in inaccessible environments. The incorporation of detection mechanisms to quantify in real time the response to external stimuli is crucial for the development of automated systems. Here, we present the first wireless opto-magnetic actuator with mechanochromic response. The device, based on a nanostructured-iron (Fe) layer transferred onto suspended elastomer structures with a periodically corrugated backside, can be actuated both optically (in a broadband spectral range) and magnetically. The combined opto-magnetic stimulus can accurately modulate the mechanical response (strength and direction) of the device. The structural coloration generated at the corrugated back surface enables to easily map and quantify, in 2D, the mechanical deflections by analyzing in real time the hue changes of images taken using a conventional RGB smartphone camera, with a precision of 0.05°. We demonstrate the independent and synergetic optical and magnetic actuation and detection with a detection limit of 1.8 mW·cm-2 and 0.34 mT, respectively. The simple operation, versatility, and cost-effectiveness of the wireless multiactuated device with highly sensitive mechanochromic mapping paves the way to a new generation of wirelessly controlled smart systems., We acknowledge funding from the Generalitat de Catalunya through the 2017-SGR-292 project. The funding from the Spanish Ministerio de Ciencia, Innovación y Universidades (MICINN) through the PID2019-106229RB-I00, MAT2016-77391-R, PCIN2016-093 (M-ERA-NET), DPI2015-68197-R, and RTI2018-096786-B-I00 projects and the Ramon y Cajal Fellowship (RyC2013-14479) is acknowledged. The PhD fellowship CIBAE-023-2014 (from SENESCYT) is also acknowledged. ICN2 is funded by the CERCA programme/Generalitat de Catalunya. The ICN2 is supported by the Severo Ochoa Centres of Excellence programme, funded by the Spanish Research Agency (AEI, grant no. SEV-2017-0706).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Soft Optomechanical Systems for Sensing, Modulation, and Actuation

  • Pujol-Vila, Ferrán
  • Güell-Grau, Pau
  • Nogués, Josep
  • Álvarez, Mar
  • Sepúlveda, Borja
Soft optomechanical systems have the ability to reversibly respond to optical and mechanical external stimuli by changing their own properties (e.g., shape, size, viscosity, stiffness, color or transmittance). These systems typically combine the optical properties of plasmonic, dielectric or carbon-based nanomaterials with the high elasticity and deformability of soft polymers, thus opening the path for the development of new mechanically tunable optical systems, sensors, and actuators for a wide range of applications. This review focuses on the recent progresses in soft optomechanical systems, which are here classified according to their applications and mechanisms of optomechanical response. The first part summarizes the soft optomechanical systems for mechanical sensing and optical modulation based on the variation of their optical response under external mechanical stimuli, thereby inducing mechanochromic or intensity modulation effects. The second part describes the soft optomechanical systems for the development of light induced mechanical actuators based on different actuation mechanisms, such as photothermal effects and phase transitions, among others. The final section provides a critical analysis of the main limitations of current soft optomechanical systems and the progress that is required for future devices., The authors acknowledge the financial support from grant nos. MAT2016-77391-R, PID2019-106229RB-I00, and PCIN2016-093 (M-ERA-NET) funded by MCIN/AEI/10.13039/501100011033, and grant nos. RTI2018-096786-B-I00 funded by MCIN/AEI/ 10.13039/501100011033 and by “ERDF A way of making Europe”. The funding from Generalitat de Catalunya through the 2017-SGR-292 project is also acknowledged. ICN2 was funded by the CERCA programme/Generalitat de Catalunya. The ICN2 was supported by the SEV-2017-0706 grant funded by MCIN/AEI/10.13039/501100011033. F.P.-V. acknowledge funding from the European Union's Horizon 2020 research and innovation programme under Marie Sklodowska-Curie grant agreement no. 801342 (Tecniopring INDUSTRY) and the Government of Catalonia's Agency for Business Competitiveness (ACCIÓ) (TECSPR19-1-0021)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Organ-on-a-chip with integrated semitransparent organic electrodes for barrier function monitoring

  • Marrero, Denise
  • Guimera, Anton
  • Maes, Laure
  • Villa, Rosa
  • Alvarez, Mar
  • Illa, Xavi
Organs-on-a-chip (OoC) are cell culture platforms that replicate key functional units of tissues in vitro. Barrier integrity and permeability evaluation are of utmost importance when studying barrier-forming tissues. Impedance spectroscopy is a powerful tool and is widely used to monitor barrier permeability and integrity in real-time. However, data comparison across devices is misleading due to the generation of a non-homogenous field across the tissue barrier, making impedance data normalization very challenging. In this work, we address this issue by integrating PEDOT:PSS electrodes for barrier function monitoring with impedance spectroscopy. The semitransparent PEDOT:PSS electrodes cover the entire cell culture membrane providing a homogenous electric field across the entire membrane making the cell culture area equally accountable to the measured impedance. To the best of our knowledge, PEDOT:PSS has never been used solely to monitor the impedance of cellular barriers while enabling optical inspection in the OoC. The performance of the device is demonstrated by lining the device with intestinal cells where we monitored barrier formation under flow conditions, as well as barrier disruption and recovery under exposure to a permeability enhancer. The barrier tightness and integrity, and the intercellular cleft have been evaluated by analyzing the full impedance spectrum. Furthermore, the device is autoclavable paving the way toward more sustainable OoC options., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Electrochemical biosensor for aerobic acetate detection

  • Forner, E
  • Ezenarro, J J
  • Pérez-Montero, M
  • Vigués, N
  • Asensio-Grau, A
  • Borges, Andrés A.
  • Mas, J
  • Baeza, M
  • Muñoz-Berbel, Xavier
  • Villa, Rosa
  • Gabriel, Gemma
There is an increasing demand on alternatives methods to animal testing. Numerous health parameters have been already studied using in vitro devices able to mimic the essential functions of the organs, being the real-time monitoring and response to stimuli their main limitations. Regarding the health of the gut, the short chain fatty acids, and particularly acetate, have emerged as key biomarkers to evaluate gut healthiness and disease development, although the number of acetate biosensors is still very low. This article presents a microbial biosensor based on fully biocompatible materials which is able to detect acetate in aerobic conditions in the range between 11 and 50 mM, and without compromising the viability and function of either bacteria (>90% viability) or mammalian cells (>80% viability). The detection mechanism is based on the metabolism of acetate by Escherichia coli bacteria immobilized on the transducer surface. Ferricyanide is used as a redox mediator to transfer electrons from the acetate metabolism in the bacterial cells to the transducer. High bacterial concentrations are immobilized in the transducer surface (109 cfu mL-1) by electrodeposition of conductive alginate hydrogels doped with reduced graphene oxide. The results show successful outcomes to exploit bacteria as a biosensing tool, based on the use of inkjet printed transducers, biocompatible materials and cell entrapment technologies., The authors acknowledge the support from the Ministerio de Ciencia Innovacion y Universidades (MICIU/FEDER, EU), in Spain, through GUMICHIP (RTI2018-096786-B-I00), GALILEI (PID2021-126253OB-C21) and CHIP4CELL projects (PID2021-127653NB-C21) and the support of the Generalitat de Catalunya to 2021SGR00495. The work has been performed by the ICTS “NANBIOSIS”, more specifically by the U8 Unit of the CIBER in Bioengineering, Biomaterials & Nanomedicine (CIBER-BBN) at the IMB-CNM (CSIC). This work also made use of the Spanish ICTS Network MICRONANOFABS partially supported by MEINCOM. We would like to thank the members of the GENOCOV research group from Universitat Autonoma, specifically Dr. D. Gabriel and PhD student M. Fachal, for their assistance in the liquid chromatography analysis presented in this work., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Salivary Cortisol Detection with a Fully Inkjet-Printed Paper-Based Electrochemical Sensor

  • Zea, Miguel
  • Ben Halima, Hamdi
  • Villa, Rosa
  • Nemeir, Imad Abrao
  • Zine, Nadia
  • Errachid, Abdelhamid
  • Gabriel, Gemma
Electrochemical paper-based analytical devices (ePADs) offer an innovative, low-cost, and environmentally friendly approach for real-time diagnostics. In this study, we developed a functional all-inkjet paper-based electrochemical immunosensor using gold (Au) printed ink to detect salivary cortisol. Covalent binding of the cortisol monoclonal antibody onto the printed Au surface was achieved through electrodeposition of 4-carboxymethylaniline (CMA), with ethanolamine passivation to prevent non-specific binding. The ePAD exhibited a linear response within the physiological cortisol range (5–20 ng/mL), with sensitivities of 25, 23, and 19 Ω·ng/mL and R2 values of 0.995, 0.979, and 0.99, respectively. Additionally, interference studies against tumor necrosis factor-α (TNF-α) and N-terminal pro-B-type natriuretic peptide (NT-proBNP) yielded excellent results. This novel ePAD, fabricated using inkjet printing technology on paper, simplifies the process, reduces environmental impact, and lowers fabrication costs., M.Z. would like to acknowledge his financial support covered by Fundación Centro de Estudios Interdisciplinarios Básicos y Aplicados (CEIBA)-Gobernación de Bolivar (Colombia). This work was supported by the Spanish government-funded project RTI2018-096786-B-I00, and RTI2018-102070-B-C21 by Ministerio de Ciencia, Innovación y Universidades (MINECO/FEDER, EU). The authors also want to thank the support of the Generalitat de Catalunya for 2017-SGR-988, and the SU-8 Unit of the CIBER in Bioengineering, Biomaterials, and Nanomedicine (CIBER-BBN) at the IMB-CNM (CSIC) of ICTS “NANBIOSIS”. This work has also made use of the Spanish ICTS Network MICRONANOFABS partially supported by MEINCOM. This work was also partially supported by the EU H2020 research and innovation program KardiaTool with agreement Nº 768686, POC Allergies through the ERA PerMed program, and from CAMPUS FRANCE program agreement PHC PROCOPE 40544QH., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

A 3D bioprinted hydrogel gut-on-chip with integrated electrodes for transepithelial electrical resistance (TEER) measurements

  • Vera, Daniel
  • García-Díaz, María
  • Torras, Núria
  • Castillo, Óscar
  • Illa, Xavi
  • Villa, Rosa
  • Alvarez, Mar
  • Castro Martínez, Elena
Conventional gut-on-chip (GOC) models typically represent the epithelial layer of the gut tissue, neglecting other important components such as the stromal compartment and the extracellular matrix (ECM) that play crucial roles in maintaining intestinal barrier integrity and function. These models often employ hard, flat porous membranes for cell culture, thus failing to recapitulate the soft environment and complex 3D architecture of the intestinal mucosa. Alternatively, hydrogels have been recently introduced in GOCs as ECM analogs to support the co-culture of intestinal cells inin vivo-like configurations, and thus opening new opportunities in the organ-on-chip field. In this work, we present an innovative GOC device that includes a 3D bioprinted hydrogel channel replicating the intestinal villi architecture containing both the epithelial and stromal compartments of the gut mucosa. The bioprinted hydrogels successfully support both the encapsulation of fibroblasts and their co-culture with intestinal epithelial cells under physiological flow conditions. Moreover, we successfully integrated electrodes into the microfluidic system to monitor the barrier formation in real time via transepithelial electrical resistance measurements., Funding for this project was provided by a European Union Horizon 2020 ERC Grant (Agreement 647863\u2014COMIET), the CERCA Programme/Generalitat de Catalunya (2017-SGR-1079), and the Spanish Ministry of Economy and Competitiveness (PID2021-129115OB-I00). The authors acknowledge support from the Ministerio de Ciencia Innovacion y Universidades, in Spain, through GUMICHIP project (RTI2018-096786-B-I00 funded by MCIN/AEI/10.13039/501100011033 and by \u2018ERDF A way of making Europe\u2019). D V acknowledge that this work has been done in the framework of the PhD in Electrical and Telecommunication Engineering at the Universitat Aut\u00F2noma de Barcelona. D V was supported by the Marie Sk\u0142odowska-Curie COFUND PhD fellowship (Grant Agreement 754397). N T acknowledges the Spanish Ministry of Science and Innovation, Juan de la Cierva program (Grant IJC2019-040289-I). This research was supported by CIBER -Consorcio Centro de Investigaci\u00F3n Biom\u00E9dica en Red- (CB06/01/0049), Instituto de Salud Carlos III, Ministerio de Ciencia e Innovaci\u00F3n. The results presented here only reflect the views of the authors; the European Commission is not responsible for any use that may be made of the information it contains., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Stable Full-Inkjet-Printed Solid-State Ag/AgCl Reference Electrode

  • Moya, Ana
  • Pol, Roberto
  • Martínez-Cuadrado, Alfonso
  • Villa, Rosa
  • Gabriel, Gemma
  • Baeza, Mireia
With a growing demand for the availability of inexpensive, simple, and rapid prototyped devices, the prospect of miniaturization of the reference electrodes using printing techniques becomes promising. A stable and reusable full-inkjet-printed solid-state reference electrode (IPRE) was developed. The reference electrode was fully produced by consecutive inkjet printing of several layers. Ag ink was printed and chlorinated by NaClO printing, forming a Ag/AgCl pseudoreference electrode. Then a surface protection by printing a Cl--saturated polyvinyl butyral membrane finally gave a reference electrode that demonstrated an outstanding performance comparable to commercial ones. This full inkjet printing fabrication strategy will improve the viability of producing low-cost miniaturized reference electrodes with interest in many electrochemical sensor-dependent areas., Undergraduate student F. Paré is acknowledged for his early contribution in this project. R. Pol acknowledges Universitat Autònoma de Barcelona (UAB) for the PIF grant. Authors also appreciate financial support from the RTI2018-099362-B-C21 and RTI2018-096786-B-I00 research projects from the Spanish Ministerio de Economí a y Competitividad y Fondo Europeo de Desarrollo Regional (MINECO/FEDER, UE). The authors also acknowledge ICTS “NANBIOSIS”, more specifically the SU8 Unit of CIBER in Bioengineering, Biomaterials & Nanomedicne (CIBER-BBN) at IMB-CNM (CSIC)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Electrochemical sensors for cortisol detections: Almost there

  • Zea, Miguel
  • Bellagambi, Francesca G.
  • Ben Halima, Hamdi
  • Zine, Nadia
  • Jaffrezic-Renault, Nicole
  • Villa, Rosa
  • Gabriel, Gemma
  • Errachid, Abdelhamid
Mostly known as “the stress hormone”, cortisol has many essential functions in humans due to its involvement in regulation of blood pressure, immune system, metabolism of protein, carbohydrate, adipose, and anti-inflammatory action. Since a right cortisol balance is essential for human health, many efforts are currently being made to monitor the cortisol level in the human body. Cortisol levels are usually monitored in blood, plasma, serum, oral fluid, sweat, and hair samples through immunochemical and analytical methods, but in the last decade, electrochemical measurements are proving to be reliable techniques for cortisol quantification in biological matrices with the advantages of a fast response by portable and wearable devices. This review gathers the most recent developments and works on electrochemical sensors for cortisol detection, highlighting their high technology maturity and potential for clinical applications., M. Zea would like to acknowledge his financial support covered by Fundación Centro de Estudios Interdisciplinarios Básicos y Aplicados (CEIBA)-Gobernación de Bolivar (Colombia). This work was supported by the Spanish government-funded project RTI2018-096786-B-I00, and RTI2018-102070-B-C21 by Ministerio de Ciencia, Innovación y Universidades (MINECO/FEDER, EU). The authors also want to thank the support of the Generalitat de Catalunya to 2017-SGR-988, and the SU-8 Unit of the CIBER in Bioengineering, Biomaterials, and Nanomedicine (CIBER-BBN) at the IMB-CNM (CSIC) of ICTS “NANBIOSIS.” This work has also made use of the Spanish ICTS Network MICRONANOFABS partially supported by MEINCOM. This work was also partially supported by the EU H2020 research and innovation program KardiaTool with agreement Nº 768686 and from CAMPUS FRANCE program agreement PHC PROCOPE 40544QH., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Gut-on-a-chip: Mimicking and monitoring the human intestine

  • Marrero, Denise
  • Pujol-Vila, Ferran
  • Vera, Daniel
  • Gabriel, Gemma
  • Illa, Xavi
  • Elizalde-Torrent, Aleix
  • Alvarez, Mar
  • Villa, Rosa
Over the last few years, the intestine has been extensively studied using in vitro microfluidic systems, commonly known as gut-on-a-chip (GOC) devices. This interest has been due not only to the importance of the intestine's proper functions but also to the relationship that this organ and the microbiota that inhabits it has with the rest of the body's organs. The increased complexity of these in vitro systems, together with the need to improve our understanding of intestinal physiology interdependencies, has led to greater focus on the integration of biosensors within these devices. However, the current number of GOC devices with integrated sensors for monitoring relevant physiological parameters are very limited and demand the use of external analytical techniques that delay the analysis and prevent real-time decision-making. This paper reviews the various materials, technologies, and structures that have been used both for mimicking the physiology of the intestine and monitoring relevant physiological parameters, such as permeability of the gut barrier, dissolved oxygen concentration, cytokines profile and the production of microbial short-chain fatty acids. We also propose alternative biosensing techniques demonstrated in other in vitro and lab-on-a-chip devices that could be translated to GOC models. A critical analysis of the requirements, limitations, and current challenges on the microenvironment replication and monitorization of GOC models is included, with a particular focus on the physiological parameters and biomarkers that should be detected simultaneously in real-time to get a proper framework of the gut function that until now, have not received the necessary attention., The authors acknowledge the support from the Ministerio de Ciencia Innovacion y Universidades (MICIU/FEDER, EU), in Spain, through GUMICHIP project (RTI2018-096786-B-I00). D. M. and D. V. acknowledge that this work has been done in the framework of the Ph.D. program in Electrical and Telecommunication Engineering at the Universitat Autònoma de Barcelona. D. V. was supported by the Marie Skłodowska-Curie COFUND PhD fellowship (grant agreement No 754397). D. M. was supported by the FPI Ph.D. fellowship (PRE2019-089214)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Specially Designed Polyaniline/Polypyrrole Ink for a Fully Printed Highly Sensitive pH Microsensor

  • Zea, Miguel
  • Texidó, Robert
  • Villa, Rosa
  • Borrós, Salvador
  • Gabriel, Gemma
pH sensing for healthcare applications requires sensors with mechanically stable materials of high sensitivity and high reproducibility combined with low-cost fabrication technologies. This work proposes a fully printed pH sensor based on a specially formulated conducting polymer deposited on a microelectrode in a flexible substrate. A formulation, which combined polyaniline (PANI) and polypyrrole (PPy) with integrated polyelectrolyte poly(sodium 4-styrenesulfonate) (PSS), was specially prepared to be printed by inkjet printing (IJP). The sensor has good sensitivity in the physiological region (pH 7-7.5) key for the healthcare biosensor. This mixture printed over a commercial gold ink, which has a singular chemical functionalization with phthalocyanine (Pc), increased the sensor sensitivity, showing an excellent reproducibility with a linear super-Nernstian response (81.2 ± 0.5 mV/pH unit) in a wide pH range (pH 3-10). This new ink together with the IJP low-cost technique opens new opportunities for pH sensing in the healthcare field with a single device, which is disposable, highly sensitive, and stable in the whole pH range., M.Z. acknowledges his financial support covered by Fundación Centro de Estudios Interdisciplinarios Básicos y Aplicados (CEIBA)-Gobernación de Bolivar (Colombia). This work was supported by the Spanish government-funded projects RTI2018-096786-B-I00 and RTI2018-102070-B-C21 by Ministerio de Ciencia, Innovación y Universidades (MINECO/FEDER, EU). The authors also thank the support of the Generalitat de Catalunya to 2017-SGR-988 and to 2017-SGR 1559 and the SU-8 Unit of the CIBER in Bioengineering, Biomaterials, and Nanomedicine (CIBER-BBN) at the IMB-CNM (CSIC) of ICTS “NANBIOSIS.” This work has also made use of the Spanish ICTS Network MICRONANOFABS partially supported by MEINCOM., Peer reviewed
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Specially Designed Polyaniline/Polypyrrole Ink for a Fully Printed Highly Sensitive pH Microsensor

  • Zea, Miguel
  • Texidó, Robert
  • Villa, Rosa|||0000-0003-2735-3204
  • Borrós, Salvador|||0000-0002-4003-0381
  • Gabriel, Gemma|||0000-0003-2140-6299
pH sensing for healthcare applications requires sensors with mechanically stable materials of high sensitivity and high reproducibility combined with low-cost fabrication technologies. This work proposes a fully printed pH sensor based on a specially formulated conducting polymer deposited on a microelectrode in a flexible substrate. A formulation, which combined polyaniline (PANI) and polypyrrole (PPy) with integrated polyelectrolyte poly(sodium 4-styrenesulfonate) (PSS), was specially prepared to be printed by inkjet printing (IJP). The sensor has good sensitivity in the physiological region (pH 7-7.5) key for the healthcare biosensor. This mixture printed over a commercial gold ink, which has a singular chemical functionalization with phthalocyanine (Pc), increased the sensor sensitivity, showing an excellent reproducibility with a linear super-Nernstian response (81.2 ± 0.5 mV/pH unit) in a wide pH range (pH 3-10). This new ink together with the IJP low-cost technique opens new opportunities for pH sensing in the healthcare field with a single device, which is disposable, highly sensitive, and stable in the whole pH range.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Mechanochromic detection for soft opto-magnetic actuators

  • Güell Grau, Pau|||0000-0002-2363-4079
  • Escudero Villa, Pedro Fernando|||0000-0003-0534-2328
  • Perdikos, Filippos Giannis
  • López-Barbera, José Francisco|||0000-0002-9475-625X
  • Pascual-Izarra, Carlos
  • Villa, Rosa|||0000-0003-2735-3204
  • Nogués, Josep|||0000-0003-4616-1371
  • Sepúlveda, Borja|||0000-0002-1562-7602
  • Alvarez, Mar|||0000-0003-4590-4401
New multi-stimuli responsive materials are required in smart systems applications to overcome current limitations in remote actuation and to achieve versatile operation in inaccessible environments. The incorporation of detection mechanisms to quantify in real time the response to external stimuli is crucial for the development of automated systems. Here, we present the first wireless opto-magnetic actuator with mechanochromic response. The device, based on a nanostructured-iron (Fe) layer transferred onto suspended elastomer structures with a periodically corrugated backside, can be actuated both optically (in a broadband spectral range) and magnetically. The combined opto-magnetic stimulus can accurately modulate the mechanical response (strength and direction) of the device. The structural coloration generated at the corrugated back surface enables to easily map and quantify, in 2D, the mechanical deflections by analyzing in real time the hue changes of images taken using a conventional RGB smartphone camera, with a precision of 0.05°. We demonstrate the independent and synergetic optical and magnetic actuation and detection with a detection limit of 1.8 mW·cm -2 and 0.34 mT, respectively. The simple operation, versatility, and cost-effectiveness of the wireless multiactuated device with highly sensitive mechanochromic mapping paves the way to a new generation of wirelessly controlled smart systems.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Soft Optomechanical Systems for Sensing, Modulation, and Actuation

  • Pujol Vila, Ferran|||0000-0002-6811-2426
  • Güell Grau, Pau|||0000-0002-2363-4079
  • Nogués, Josep|||0000-0003-4616-1371
  • Alvarez, Mar|||0000-0003-4590-4401
  • Sepúlveda, Borja|||0000-0002-1562-7602
Soft optomechanical systems have the ability to reversibly respond to optical and mechanical external stimuli by changing their own properties (e.g., shape, size, viscosity, stiffness, color or transmittance). These systems typically combine the optical properties of plasmonic, dielectric or carbon-based nanomaterials with the high elasticity and deformability of soft polymers, thus opening the path for the development of new mechanically tunable optical systems, sensors, and actuators for a wide range of applications. This review focuses on the recent progresses in soft optomechanical systems, which are here classified according to their applications and mechanisms of optomechanical response. The first part summarizes the soft optomechanical systems for mechanical sensing and optical modulation based on the variation of their optical response under external mechanical stimuli, thereby inducing mechanochromic or intensity modulation effects. The second part describes the soft optomechanical systems for the development of light induced mechanical actuators based on different actuation mechanisms, such as photothermal effects and phase transitions, among others. The final section provides a critical analysis of the main limitations of current soft optomechanical systems and the progress that is required for future devices.