Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 15
Encontrada(s) 1 página(s)

Dipòsit Digital de la UB
Publicación Artículo científico (JournalArticle)

Development of an ImmunoFET for Analysis of Tumour Necrosis Factor- (alfa) in Artificial Saliva: Application for Heart Failure Monitoring

  • Vozgirdaite, Daiva
  • Ben Halima, Hamdi
  • Bellagambi, Francesca G.
  • Alcacer, Albert
  • Palacio Bonet, Francisco
  • Jaffrezic Renault, Nicole
  • Zine, Nadia
  • Bausells, Joan
  • Elaissari, Abdelhamid
  • Errachid, Abdelhamid
Assessing tumour necrosis factor-(alfa) (TNF-(alfa)) levels in the human body has become an essential tool to recognize heart failure (HF). In this work, label-free, rapid, easy to use ImmunoFET based on an ion-sensitive field effect transistor (ISFET) was developed for the detection of TNF-(alfa) protein. Monoclonal anti-TNF-(alfa) antibodies (anti-TNF-(alfa) mAb) were immobilized on an ISFET gate made of silicon nitride (Si3N4) after salinization with 11-(triethoxysilyl) undecanal (TESUD). The obtained ISFET functionalized with the mAbs (ImmunoFET) was used to detect TNF-(alfa) protein in both phosphate buffer saline (PBS) and artificial saliva (AS). The change in the threshold voltage of the gate (DVT) showed approximately linear dependency on the concentration of the antigens in the range 5-20 pg/mL for both matrixes. The cross-selectivity study showed that the developed ImmunoFET demonstrated to be selective towards TNF-(alfa), when compared to other HF biomarkers such as N-terminal pro-brain natriuretic peptide (NT-proBNP), interleukin-10 (IL-10), and cortisol, even if further experiments have to be carried out for decreasing possible unspecific absorption phenomena. To the best of our knowledge, this is the first ImmunoFET that has been developed based on Si3N4 for TNF-(alfa) detection in AS by electrical measurement.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

A simple membrane with the electroactive [Sulfapyridine-H]+[Co(C2B9H11)2]- f

  • Saini, Abhishek
  • Fuentes Sempere, Isabel
  • Viñas, Clara
  • Zine, Nadia
  • Bausells, Joan
  • Errachid, Abdelhamid
  • Teixidor, Francesc
The detection of a drug belonging to the Sulfonamide class of compounds, namely Sulfapyridine, is reported in this work using an in-situ and fast potentiometric method. The strategy employed for this detection is based on the novel ion pair complex, [Sulfapyridine-H]+[Co(C2B9H11)2]- acting as the active site for highly selective recognition of Sulfapyridine. This enables the sensor's selectivity to be improved by incorporating the target molecule to the selective membrane. In this work, all solid state Sulfapyridine selective microelectrodes based on PVC-type membranes were prepared using three different plasticizers and the aforementioned ion pair complex. The sensors developed have provided quick and accurate response within the range of 10−6 mol/dm3 to 10−3 mol/dm3 of Sulfapyridine concentration and showed a Nernstian slope between 47 and 61 depending upon the type of plasticizer used. The lowest limit of detection achieved was 4 μmol/dm3. The potentiometric coefficient of selectivity, KA,Bpot, has shown that the Sulfapyridine-selective microsensors were highly selective towards Sulfapyridine even when compared to other members of the Sulfonamides class of compounds. In addition, from the Reilley diagram it can be observed that the sensor signal is stable for a working pH interval between 6.00 and 8.00., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Capacitance Electrochemical pH Sensor Based on Different Hafnium Dioxide (HfO2) Thicknesses

  • Fredj, Zina
  • Baraket, Abdoullatif
  • Ben Ali, Mounir
  • Zine, Nadia
  • Zabala, Miguel
  • Bausells, Joan
  • Elaissari, Abdelhamid
  • Benson, Nsikak U.
  • Jaffrezic-Renault, Nicole
  • Errachid, Abdelhamid
© 2021 by the authors., Over the past years, to achieve better sensing performance, hafnium dioxide (HfO2) has been studied as an ion-sensitive layer. In this work, thin layers of hafnium dioxide (HfO2) were used as pH-sensitive membranes and were deposited by atomic layer deposition (ALD) process onto an electrolytic-insulating-semiconductor structure Al/Si/SiO2/HfO2 for the realization of a pH sensor. The thicknesses of the layer of the HfO2 studied in this work was 15, 19.5 and 39.9 nm. HfO2 thickness was controlled by ALD during the fabrication process. The sensitivity toward H+ was clearly higher when compared to other interfering ions such as potassium K+, lithium Li+, and sodium Na+ ions. Mott−Schottky and electrochemical impedance spectroscopy (EIS) analyses were used to characterise and to investigate the pH sensitivity. This was recorded by Mott–Schottky at 54.5, 51.1 and 49.2 mV/pH and by EIS at 5.86 p[H−1], 10.63 p[H−1], 12.72 p[H−1] for 15, 19.5 and 30 nm thickness of HfO2 ions sensitive layer, respectively. The developed pH sensor was highly sensitive and selective for H+ ions for the three thicknesses, 15, 19.5 and 39.9 nm, of HfO2-sensitive layer when compared to the other previously mentioned interferences. However, the pH sensor performances were better with 15 nm HfO2 thickness for the Mott–Schottky technique, whilst for EIS analyses, the pH sensors were more sensitive at 39.9 nm HfO2 thickness., Funding through the European Union’s Horizon 2020 research and innovation program entitled “An integrated POC solution for non-invasive diagnosis and therapy monitoring of Heart Failure patients, KardiaTool” under grant agreement No 768686., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Magnetic Nanoparticles Fishing for Biomarkers in Artificial Saliva

  • Saha, Arpita
  • Ben Halima, Hamdi
  • Saini, Abhishek
  • Gallardo González, Juan
  • Zine, Nadia
  • Viñas, Clara
  • Elaissari, Abdelhamid
  • Errachid, Abdelhamid
  • Teixidor, Francesc
Magnetic nanoparticles (MNPs) were synthesized using the colloidal co-precipitation method and further coated with silica using the Stöber process. These were functionalized with carboxylic and amine functionalities for further covalent immobilization of antibodies on these MNPs. The procedure for covalent immobilization of antibodies on MNPs was developed using 1-ethyl-3-(dimethylaminopropyl)carbodiimide (EDC) and N-hydroxysuccinimide (NHS). The evaluation of the efficiency of the coupling reaction was carried out by UV-vis spectrophotometry. The developed antibodies coupled to MNPs were tested for the pre-concentration of two biomarkers tumor necrosis factor alpha (TNF-α) and Interleukin-10 (IL-10). Both biomarkers were assessed in the matrix based on phosphate-buffered saline solution (PBS) and artificial saliva (AS) to carry out the demonstration of the format assay. Supernatants were used to determine the number of free biomarkers for both studies. Reduction of the nonspecific saliva protein adsorption on the surface of the complex antibodies-MNPs to levels low enough to allow the detection of biomarkers in complex media has been achieved, We acknowledge the funding through the European Union’s Horizon 2020 research and innovation programme entitled (An integrated POC solution for non-invasive diagnosis and therapy monitoring of Heart Failure patients, KardiaTool) under grant agreement No 768686 and from CAMPUS FRANCE program under grant agreement PHC PROCOPE 40544QH. This work has been supported by the Spanish Ministerio de Economia y Competitividad (CTQ2016-75150-R), CSIC through 2019AEP132 and Generalitat de Catalunya (2014/SGR/149)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

History of Cobaltabis(dicarbollide) in Potentiometry, No Need for Ionophores to Get an Excellent Selectivity

  • Stoica, Anca-Iulia
  • Viñas, Clara
  • Teixidor, Francesc
This work is a mini-review highlighting the relevance of the θ metallabis(dicarbollide) [3,3'-Co(1,2-C2B9H11)2]- with its peculiar and differentiating characteristics, among them the capacity to generate hydrogen and dihydrogen bonds, to generate micelles and vesicles, to be able to be dissolved in water or benzene, to have a wide range of redox reversible couples and many more, and to use these properties, in this case, for producing potentiometric membrane sensors to monitor amine-containing drugs or other nitrogen-containing molecules. Sensors have been produced with this monoanionic cluster [3,3'-Co(1,2-C2B9H11)2]-. Other monoanionic boron clusters are also discussed, but they are much fewer. It is noteworthy that most of the electrochemical sensor species incorporate an ammonium cation and that this cation is the species to be detected. Alternatively, the detection of the borate anion itself has also been studied, but with significantly fewer examples. The functions of the borate anion in the membrane are different, even as a doping agent for polypyrrole which was the conductive ground on which the PVC membrane was deposited. Apart from these cases related to closo borates, the bulk of the work has been devoted to sensors in which the θ metallabis (dicarbollide) [3,3'-Co(1,2-C2B9H11)2]- is the key element. The metallabis (dicarbollide) anion, [3,3'-Co(1,2-C2B9H11)2]-, has many applications; one of these is as new material used to prepare an ion-pair complex with bioactive protonable nitrogen containing compounds, [YH]x[3,3'-Co(1,2-C2B9H11)2]y as an active part of PVC membrane potentiometric sensors. The developed electrodes have Nernstian responses for target analytes, i.e., antibiotics, amino acids, neurotransmitters, analgesics, for some decades of concentrations, with a short response time, around 5 s, a good stability of membrane over 45 days, and an optimal selectivity, even for optical isomers, to be used also for real sample analysis and environmental, clinical, pharmaceutical and food analysis., This work research was funded by the European Union’s Horizon 2020 grant number 768686, the Spanish Ministerio de Economía y Competitividad grant number PID2019-106832RB-I00 and, the Generalitat de Catalunya grant number 2017SGR1720., With funding from the Spanish government through the ‘Severo Ochoa Centre of Excellence’ accreditation (CEX2019-000917-S)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Selective Antibody-Free Sensing Membranes for Picogram Tetracycline Detection

  • Ben Halima, Hamdi
  • Baraket, Abdoullatif
  • Viñas, Clara
  • Zine, Nadia
  • Bausells, Joan
  • Jaffrezic-Renault, Nicole
  • Teixidor, Francesc
  • Errachid, Abdelhamid
As an antibody-free sensing membrane for the detection of the antibiotic tetracycline (TC), a liquid PVC membrane doped with the ion-pair tetracycline/θ-shaped anion [3,3'-Co(1,2-C2B9H11)2]- ([o-COSAN]-) was formulated and deposited on a SWCNT modified gold microelectrode. The chosen transduction technique was electrochemical impedance spectroscopy (EIS). The PVC membrane was composed of: the tetracycline/[o-COSAN]- ion-pair, a plasticizer. A detection limit of 0.3 pg/L was obtained with this membrane, using bis(2-ethylhexyl) sebacate as a plasticizer. The sensitivity of detection of tetracycline was five times higher than that of oxytetracycline and of terramycin, and 22 times higher than that of demeclocycline. A shelf-life of the prepared sensor was more than six months and was used for detection in spiked honey samples. These results open the way to having continuous monitoring sensors with a high detection capacity, are easy to clean, avoid the use of antibodies, and produce a direct measurement., The authors acknowledge the financial support of the European Union’s Horizon 2020 research and innovation program, Project NMBP–13-2017 KardiaTool (Grant agreement No. 768686), SEA-on-a-CHIP (FP7- OCEAN-2013) under the grant agreement No. 614168. The authors acknowledge the financial support from the POC4allergies project (Grant Agreement No. 768686), which received funding from ERA PerMed ERA-NET, and the financial support from the Bionanosens project (Grant Agreement No. 9[887]), which received funding from the European Union’s Horizon 2020., With funding from the Spanish government through the ‘Severo Ochoa Centre of Excellence’ accreditation (CEX2019-000917-S)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Towards the Application of Purely Inorganic Icosahedral Boron Clusters in Emerging Nanomedicine

  • Teixidor, Francesc
  • Núñez Aguilera, Rosario
  • Viñas, Clara
Traditionally, drugs were obtained by extraction from medicinal plants, but more recently also by organic synthesis. Today, medicinal chemistry continues to focus on organic compounds and the majority of commercially available drugs are organic molecules, which can incorporate nitrogen, oxygen, and halogens, as well as carbon and hydrogen. Aromatic organic compounds that play important roles in biochemistry find numerous applications ranging from drug delivery to nanotechnology or biomarkers. We achieved a major accomplishment by demonstrating experimentally/theoretically that boranes, carboranes, as well as metallabis(dicarbollides), exhibit global 3D aromaticity. Based on the stability-aromaticity relationship, as well as on the progress made in the synthesis of derivatized clusters, we have opened up new applications of boron icosahedral clusters as key components in the field of novel healthcare materials. In this brief review, we present the results obtained at the Laboratory of Inorganic Materials and Catalysis (LMI) of the Institut de Ciència de Materials de Barcelona (ICMAB-CSIC) with icosahedral boron clusters. These 3D geometric shape clusters, the semi-metallic nature of boron and the presence of exo-cluster hydrogen atoms that can interact with biomolecules through non-covalent hydrogen and dihydrogen bonds, play a key role in endowing these compounds with unique properties in largely unexplored (bio)materials., This work research was funded by the European Union’s Horizon 2020 grant number 768686, the Spanish Ministerio de Economía y Competitividad grant number PID2019-106832RB-I00 and, the Generalitat de Catalunya grant number 2017SGR1720., With funding from the Spanish government through the ‘Severo Ochoa Centre of Excellence’ accreditation (CEX2019-000917-S)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

A novel electrochemical strategy for NT-proBNP detection using IMFET for monitoring heart failure by saliva analysis

  • Ben Halima, Hamdi
  • Bellagambi, Francesca G
  • Hangouët, Marie
  • Alcacer, Albert
  • Pfeiffer, Norman
  • Heuberger, Albert
  • Zine, Nadia
  • Bausells, Joan
  • Elaissari, Abdelhamid
  • Errachid, Abdelhamid
Heart failure (HF) is a chronic cardiovascular disease that represents main cause of mortality worldwide, particularly for elderly. N-terminal pro-brain natriuretic peptide (NT-proBNP) was identified as the gold standard biomarker for HF diagnosis and therapy monitoring. Presently, saliva analysis represents an emerging and powerful tool for clinical applications and electrochemical immunosensors have shown their potential in Healthcare applications as selective and reliable systems for detecting clinical biomarkers. This work presents the detection of NT-proBNP in saliva samples by an immunologically modified Field effect Transistor (IMFET). TESUD ((11-triethoxysilyl) undecanal) was used as cross-linker to immobilise anti-NT-proBNP antibody onto the device. Our IMFET that was then tested in different matrices (e.g. phosphate buffered saline (PBS), artificial saliva and human saliva) using electrochemical impedance spectroscopy (EIS), and it resulted selective to NT-proBNP with good sensitivity (detection limit of 0.02 pg/mL) and a wide linear range (0.02-1 pg/mL and 0.5-20 pg/mL). Finally, NT-proBNP concentration in ten saliva samples was determined by performing the standard addition method. An enzyme-linked immunosorbent assay was used for confirming IMFET results, highlighting both IMFET accuracy (analyte recovery of 99 ± 8%) and precision (coefficient of variation always <10%), and supporting the suitability of the device for determining salivary NT-proBNP., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

One-step impedimetric NT-proBNP aptasensor targeting cardiac insufficiency in artificial saliva

  • Ruankham, Waralee
  • Morales Frías, Isaac Aarón
  • Phopin, Kamonrat
  • Tantimongcolwat, Tanawut
  • Bausells, Joan
  • Zine, Nadia
  • Errachid, Abdelhamid
Currently, sensitive and accurate approaches for diagnosis, rapid assessment, and cardiac biomarker monitoring in patients with heart failure are needed. In this context, the advantages of aptamers over traditional antibodies have been employed to fabricate a single-step impedimetric N-terminal pro b-type natriuretic peptide (NT-proBNP)-modified gold microelectrode array. The development of an electrochemical aptasensing platform was based on the coimmobilization of alkanethiol self-assembled monolayers and amine-terminated aptamer that specifically recognized cardiac NT-proBNP protein resulting in charge electron transfer. Electroimpedimetric signals of the sensor were observed to be linear to the NT-proBNP concentrations in the range of 5.0 × 10-3 to 1.0 pg mL-1 (R2 = 0.9624), while achieving a low detection limit of 5.0 × 10-3 pg mL-1. Clinically relevant detection levels for NT-proBNP were achieved in a simple, rapid, and label-free measurement using artificial saliva, which was highlighted to be specific, regenerative, and selective over potential interferers occurring during the processes of cardiac insufficiency, Therefore, the novel NT-proBNP aptasensor is a promising point-of-care tool exhibiting safe, non-invasive, affordable, and non-prescription home use accessible to overcome the limitations associated with conventional ELISA and previous aptasensing., This work was financially supported by the Franco-Thai Cooperation Programme in Higher Education and Research/Franco-Thai Mobility Programme/ PHC SIAM 2020–2021; the POC4allergies project from ERA PerMed ERA-NET [grant number 768686]; and the Bionanosens project from the European Union's Horizon 2020 [grant number 951887]., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

A Novel IMFET Biosensor Strategy for Interleukin-10 Quantification for Early Screening Heart Failure Disease in Saliva

  • Ben Halima, Hamdi
  • Bellagambi, Francesca G.
  • Hangouët, Marie
  • Alcacer, Albert
  • Pfeiffer, Norman
  • Heuberger, Albert
  • Zine, Nadia
  • Bausells, Joan
  • Errachid, Abdelhamid
We propose a salivary Interleukin-10 detection strategy as part of an easily integrable Lab-on-Chip and Point-of-Care IMFET for multi-detection Heart Failure (HF) biomarkers. Our developed IMFET showed good linearity between increasing IL-10 concentration and the charge transfer resistance in both standard solutions and real saliva samples with a LOD of 0.02 pg mL−1. Moreover, the cross-selectivity study showed that the developed IMFET was highly selective towards IL-10 against other HF biomarkers. The precision of our IMFET was also evaluated, and the difference between the determined IL-10 concentration using the standard addition method and its expected one is<20 %., The authors acknowledge the financial support of the European Union's Horizon 2020 research and innovation program, Project NMBP-13-2017 KardiaTool (Grant agreement No. 768686). The authors acknowledge the financial support from the POC4allergies project (Grant Agreement No. 768686), which received funding from ERA PerMed ERA-NET, and the financial support from Bionanosens project (Grant agreement No. 951887), which received funding from the European Union's Horizon 2020., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Copper-free click chemistry assisted antibodies for immunodetection of interleukin-10 in saliva

  • Hilali, Nazha
  • Ruankham, Waralee
  • Aarón Morales Frías, Isaac
  • Bellagambi, Francesca G.
  • Hangouët, Marie
  • Martin, Marie
  • Bausells, Joan
  • Mohammadi, Hasna
  • Amine, Aziz
  • Zine, Nadia
  • Errachid, Abdelhamid
Interleukin-10 (IL-10) is an anti-inflammatory cytokine that is secreted in response to an acute phase inflammation in patients who are suffering from heart failure (HF). The aim of this work was to develop an electrochemical biosensor for determining salivary IL-10 levels. Biofunctionalization strategy was improved through the use of copper-free click chemistry for the developed sensor due to its advantages, leading to high quantitative yields of stable triazoles, rapid reaction, no cytotoxic Cu(I) catalyst requirement, and high specificity of cyclooctynes toward azides. The approach involved in binding of dibenzocyclooctyne acid (DBCO-COOH) to thiol-azide assembled gold microelectrodes, later capturing the monoclonal IL-10 antibody (IL-10 mAb), and ultimately allowing direct detection of IL-10 antigen. Fourier transform infrared spectroscopy (FTIR) and nanoplotter associated with fluorescence microscopy methods have been employed to analyze and prove the biofunctionalization of the gold microelectrodes. Moreover, the electrochemical impedance spectroscopy (EIS) technique was used for detecting IL-10 antigen. The developed immunosensor showed a semi-logarithmic linear range, from 0.1 pg/mL to 5 pg/mL with R2 = 0.9815 and a limit of quantitation (LOQ) of 0.1 pg/mL with relative standard deviation (RSD) of 10.67%. The specificity of the immunosensor was evaluated using an inflammatory cytokine, and none of it generated detectable EIS signals. Finally, the successful analysis of saliva samples from a healthy volunteer without Coronavirus (COVID-19) infection demonstrated the usefulness of the developed immunosensor., The authors acknowledge financial support from the CAMPUS FRANCE program under grant agreement PHC Maghreb n° 39382RE, PHC phase 2, French Eiffel scholarship 2020, CNRST of Morocco, as well as the financial support of the POC4allergies project (Grant Agreement No. 768686), which received funding from ERA PerMed ERA-NET, and the financial support from Bionanosens project (Grant agreement No. 951887), which received funding from the European Union's Horizon 2020., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Immuno field-effect transistor (ImmunoFET) for detection of salivary cortisol using potentiometric and impedance spectroscopy for monitoring heart failure

  • Ben Halima, Hamdi
  • Bellagambi, Francesca G
  • Brunon, Fabien
  • Alcacer, Albert
  • Pfeiffer, Norman
  • Heuberger, Albert
  • Hangouët, Marie
  • Zine, Nadia
  • Bausells, Joan
  • Errachid, Abdelhamid
Cortisol, a steroid hormone mostly known as "the stress hormone," plays many essential functions in humans due its involvement in several metabolic pathways. It is well-known that cortisol dysregulation is implied in evolution and progression of several chronic pathologies, including cardiac diseases such as heart failure (HF). However, although several sensors have been proposed to date for the determination of cortisol, none of them has been designed for its determination in saliva in order to monitor HF progression. In this work, a silicon nitride based Immuno field-effect transistor (ImmunoFET) has been proposed to quantify salivary cortisol for HF monitoring. Sensitive biological element was represented by anti-cortisol antibody bound onto the ISFET gate via 11-triethoxysilyl undecanal (TESUD) by vapor-phase method. Potentiometric and electrochemical impedance spectroscopy (EIS) measurements were carried out for preliminary investigations on device responsiveness. Subsequently, a more sensitive detection was obtained using electrochemical EIS. The proposed device has proven to have a linear response (R2 always >0.99), to be sensitive (with a limit of detection, LoD, of 0.005 ± 0.002 ng/mL), selective in case of other HF biomarkers (e.g. N-terminal pro B-type natriuretic peptide (NT-proBNP), tumor necrosis factor-alpha (TNF-α), and interleukin 10 (IL-10)), and accurate in cortisol quantification in saliva sample by performing the standard addition method., The authors acknowledge the financial support of the European Union's Horizon 2020 research and innovation programme , Project NMBP-13-2017 KardiaTool (Grant agreement No. 768686 ). The financial support of the POC4allergies project (ERAPERMED2019-127), which received funding from ERA PerMed ERA-NET , and the financial support from Bionanosens project (Grant agreement No. 951887 ), which received funding from the European Union's Horizon 2020 ., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Salivary Cortisol Detection with a Fully Inkjet-Printed Paper-Based Electrochemical Sensor

  • Zea, Miguel
  • Ben Halima, Hamdi
  • Villa, Rosa
  • Nemeir, Imad Abrao
  • Zine, Nadia
  • Errachid, Abdelhamid
  • Gabriel, Gemma
Electrochemical paper-based analytical devices (ePADs) offer an innovative, low-cost, and environmentally friendly approach for real-time diagnostics. In this study, we developed a functional all-inkjet paper-based electrochemical immunosensor using gold (Au) printed ink to detect salivary cortisol. Covalent binding of the cortisol monoclonal antibody onto the printed Au surface was achieved through electrodeposition of 4-carboxymethylaniline (CMA), with ethanolamine passivation to prevent non-specific binding. The ePAD exhibited a linear response within the physiological cortisol range (5–20 ng/mL), with sensitivities of 25, 23, and 19 Ω·ng/mL and R2 values of 0.995, 0.979, and 0.99, respectively. Additionally, interference studies against tumor necrosis factor-α (TNF-α) and N-terminal pro-B-type natriuretic peptide (NT-proBNP) yielded excellent results. This novel ePAD, fabricated using inkjet printing technology on paper, simplifies the process, reduces environmental impact, and lowers fabrication costs., M.Z. would like to acknowledge his financial support covered by Fundación Centro de Estudios Interdisciplinarios Básicos y Aplicados (CEIBA)-Gobernación de Bolivar (Colombia). This work was supported by the Spanish government-funded project RTI2018-096786-B-I00, and RTI2018-102070-B-C21 by Ministerio de Ciencia, Innovación y Universidades (MINECO/FEDER, EU). The authors also want to thank the support of the Generalitat de Catalunya for 2017-SGR-988, and the SU-8 Unit of the CIBER in Bioengineering, Biomaterials, and Nanomedicine (CIBER-BBN) at the IMB-CNM (CSIC) of ICTS “NANBIOSIS”. This work has also made use of the Spanish ICTS Network MICRONANOFABS partially supported by MEINCOM. This work was also partially supported by the EU H2020 research and innovation program KardiaTool with agreement Nº 768686, POC Allergies through the ERA PerMed program, and from CAMPUS FRANCE program agreement PHC PROCOPE 40544QH., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

An ImmunoFET Coupled with an Immunomagnetic Preconcentration Technique for the Sensitive EIS Detection of HF Biomarkers

  • Ben Halima, Hamdi
  • Zine, Nadia
  • Nemeir, Imad Abrao
  • Pfeiffer, Norman
  • Heuberger, Albert
  • Bausells, Joan
  • Elaissari, Abdelhamid
  • Jaffrezic-Renault, Nicole
  • Errachid, Abdelhamid
This article belongs to the Special Issue Miniaturized Chemical Sensors., We propose a new strategy using a sandwich approach for the detection of two HF biomarkers: tumor necrosis factor-α (TNF-α) and interleukin-10 (IL-10). For this purpose, magnetic nanoparticles (MNPs) (MNPs@aminodextran) were biofunctionalized with monoclonal antibodies (mAbs) using bis (sulfosuccinimidyl) suberate (BS3) as a cross-linker for the pre-concentration of two biomarkers (TNF-α and IL-10). In addition, our ISFETs were biofunctionalized with polyclonal antibodies (pAbs) (TNF-α and IL-10). The biorecognition between pAbs immobilized on the ISFET and the pre-concentrate antigen (Ag) on MNPs was monitored using electrochemical impedance spectroscopy (EIS). Our developed ImmunoFET showed a low detection limit (0.03 pg/mL) toward our target analyte when compared to previously published electrochemical immunosensors. It showed a higher sensitivity than for other HF biomarkers. Finally, the standard addition method was used to determine the unknown concentration in artificial saliva. The results matched with the expected values well., The authors acknowledge the financial support of the European Union\u2019s Horizon 2020 research and innovation program, Project NMBP\u221213-2017 KardiaTool (Grant agreement No. 768686). The authors acknowledge the financial support of the POC4allergies project (Grant Agreement No. 768686), which received funding from ERA PerMed ERA-NET, and the financial support of the Bionanosens project (Grant agreement No. 951887), which received funding from the European Union\u2019s Horizon 2020, Peer reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Development of an ImmunoFET for Analysis of Tumour Necrosis Factor- (alfa) in Artificial Saliva: Application for Heart Failure Monitoring

  • Vozgirdaite, Daiva
  • Ben Halima, Hamdi
  • Bellagambi, Francesca G.
  • Alcacer, Albert
  • Palacio Bonet, Francisco
  • Jaffrezic Renault, Nicole
  • Zine, Nadia
  • Bausells, Joan
  • Elaissari, Abdelhamid
  • Errachid, Abdelhamid
Assessing tumour necrosis factor-(alfa) (TNF-(alfa)) levels in the human body has become an essential tool to recognize heart failure (HF). In this work, label-free, rapid, easy to use ImmunoFET based on an ion-sensitive field effect transistor (ISFET) was developed for the detection of TNF-(alfa) protein. Monoclonal anti-TNF-(alfa) antibodies (anti-TNF-(alfa) mAb) were immobilized on an ISFET gate made of silicon nitride (Si3N4) after salinization with 11-(triethoxysilyl) undecanal (TESUD). The obtained ISFET functionalized with the mAbs (ImmunoFET) was used to detect TNF-(alfa) protein in both phosphate buffer saline (PBS) and artificial saliva (AS). The change in the threshold voltage of the gate (DVT) showed approximately linear dependency on the concentration of the antigens in the range 5-20 pg/mL for both matrixes. The cross-selectivity study showed that the developed ImmunoFET demonstrated to be selective towards TNF-(alfa), when compared to other HF biomarkers such as N-terminal pro-brain natriuretic peptide (NT-proBNP), interleukin-10 (IL-10), and cortisol, even if further experiments have to be carried out for decreasing possible unspecific absorption phenomena. To the best of our knowledge, this is the first ImmunoFET that has been developed based on Si3N4 for TNF-(alfa) detection in AS by electrical measurement.