Pasar al contenido principal

CONSTRUCCION DE LOS SENSORES DE STRIP DEL ITK DE ATLAS Y DESARROLLO DE LAS TECNOLOGIAS PARA LOS SENSORES DE LOS FUTUROS EXPERIMENTOS

PID2021-126327OB-C22

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2021
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 18
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Establishing the Quality Assurance programme for the strip sensor production of the ATLAS tracker upgrade including irradiation with neutrons, photons and protons to HL-LHC fluences

  • Kopsalis, I.
  • Allport, P.
  • Bach, Eric
  • Bhardwaj, A.
  • Chisholm, A.
  • Cindro, V.
  • Fadeyev, V.
  • Federicova, P.
  • Fernández-Tejero, Javier
  • Fleta, Celeste
  • Freeman, P.
  • George, W.
  • Glover, J.
  • Gonella, L.
  • Hara, K.
  • Hirose, S.
  • Hunter, A.
  • Ishii, T.
  • Knight, T.
  • Kroll, J.
  • Kvasnicka, J.
  • Lacasta, C.
  • Latonova, V.
  • Lomas, J.
  • Mandić, I.
  • Mikestikova, M.
  • Nakamura, K.
  • Orr, R. S.
  • Pyatt, S.
  • Sato, K.
  • Solaz, C.
  • Soldevila, U.
  • Thomas, J.
  • Ullán Comes, Miguel
  • Unno, Y.
The successful pre-production delivery of strip sensors for the new Inner Tracker (ITk) for the upgraded ATLAS detector at the High Luminosity LHC (HL-LHC) at CERN was completed and based on their performance full production has commenced. The overall delivery period is anticipated to last 4 years to complete the approximately 22000 sensors required for the ITk. For Quality Assurance (QA), a number of test structures designed by the collaboration, along with a large area diode and miniature version of the main sensor, are produced in every wafer by the foundry Hamamatsu Photonics K.K (HPK). As well as Quality Control (QC) checks on every main sensor, samples of the QA pieces from each delivery batch are tested both before and after irradiation with results after exposure to neutrons, gammas or protons to fluences and doses corresponding to those anticipated after operation at the HL-LHC to roughly 1.5 times the ultimate integrated luminosity of 4000 fb-1. In this paper the procedures are presented and the studies carried out to establish that the seven ITk QA Strip Sensor irradiation and test sites meet all the requirements to support this very extensive programme throughout the strip sensor production phase for the ITk project., The authors acknowledge, the Particle Physics Consolidated Grants received from the UK Research and Innovation — STFC Grants. ST/N000463/1, ST/N001125/1, ST/P005888/1, the US Department of Energy — Grant DE-SC0010107, the Canada Foundation for Innovation, the Natural Science and Engineering Research Council, the Ministry of Education of the Czech Republic projects LTT17018 Inter-Excellence and LM2018104 CERN-CZ and the Charles University grant GAUK 942119, the support from the Slovenian Research Agency (research core funding No. P1 0135) and the Spanish R&D grant PID2021-126327OB-C22, funded by MCIN/AEI/10.13039/501100011033/FEDER, UE., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

TCAD simulation of the electrical performance of the ATLAS18 strip sensor for the HL-LHC

  • Jessiman, C.
  • Dandoy, J.
  • Fadeyev, V.
  • Griffin, R.
  • Keller, J.
  • Klein, C. T.
  • Koffas, T.
  • Staats, E.
  • Ullan, M.
  • Unno, Y.
  • Walker, A.
To cope with the increased occupancy and radiation dose expected at the High-Luminosity LHC, the ATLAS experiment will replace its current Inner Detector with the Inner Tracker (ITk), consisting of silicon-based pixel and strip sub-detectors. The strip detector will consist of n<sup>+</sup>-in-p sensors fabricated by Hamamatsu Photonics, with 300 μm signal-generation thickness and approximately 75 μm strip pitch. To guide the operation of these sensors in the ITk, it is desirable to understand the basic mechanisms underlying their performance, including the effects of the radiation fluence (up to 1.6×10<sup>15</sup> 1-MeV n<inf>eq</inf>/cm<sup>2</sup>) expected during operation. To this end, we have used Sentaurus TCAD to develop a 2D simulation of the ITk large-format strip sensor, based on detailed optical and electrical measurements of the sensors and of test devices fabricated on the same wafers. Current–voltage and capacitance–voltage behaviour is reproduced in the simulation by implementing charge trapping due to defects in the silicon, and the dependence of sensor behaviour on the location of these defects is investigated. Defect parameters are obtained using existing frameworks, such as the Perugia model of surface and bulk radiation damage, and through deep-level transient spectroscopy of test devices on the sensor wafers., This work was supported by the Natural Sciences and Engineering Research Council of Canada and the Canadian Foundation for Innovation . This work is part of the Spanish R&D grant PID2021-126327OB-C22 , funded by MCIN/AEI/ 10.13039/501100011033/FEDER , UE. The work at SCIPP was supported by the US Department of Energy , grant DE-SC0010107 ., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

TCAD simulations of humidity-induced breakdown of silicon sensors

  • Ninca, I. S.
  • Bloch, I.
  • Brüers, B.
  • Fadeyev, V.
  • Fernández-Tejero, Javier
  • Jessiman, C.
  • Keller, J.
  • Klein, C. T.
  • Koffas, T.
  • Lacker, H. M.
  • Li, P.
  • Scharf, C.
  • Staats, E.
  • Ullan, M.
  • Unno, Y.
The breakdown voltage of silicon sensors is known to be affected by the ambient humidity. To understand the sensor's humidity sensitivity, Synopsys TCAD was used to simulate n-in-p sensors for different effective relative humidities. Photon emission of hot electrons was imaged with a microscope to locate breakdown in the edge-region of the sensor. The Top-Transient Current Technique was used to measure charge transport near the surface in the breakdown region of the sensor. Using the measurements and simulations, the evolution of the electric field with relative humidity and the carrier densities towards breakdown in the periphery of p-bulk silicon sensors are investigated., Funding text 1 The work at CNM is part of the Spanish R&D grant PID2021-126327OB-C22, funded by MCIN/AEI/10.13039/501100011033/FEDER, UE. The work at SCIPP was supported by the US Department of Energy, grant DE-SC0010107. The work at SFU, TRIUMF and Carleton University was supported by the Canada Foundation for Innovation and the Natural Sciences and Engineering Research Council of Canada, Copyright 2024 CERN for the benefit of the ATLAS Collaboration. Reproduction of this article or parts of it is allowed as specified in the CC-BY-4.0 license. Funding text 2 The work at CNM is part of the Spanish R&D grant PID2021-126327OB-C22 , funded by MCIN/ AEI / 10.13039/501100011033/FEDER , UE. The work at SCIPP was supported by the US Department of Energy , grant DE-SC0010107 . The work at SFU, TRIUMF and Carleton University was supported by the Canada Foundation for Innovation and the Natural Sciences and Engineering Research Council of Canada, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Long-term humidity exposure of ATLAS18 ITk strip sensors

  • Fadeyev, V.
  • Affolder, A.
  • Dowling, A.
  • Fernández-Tejero, Javier
  • Gunnell, J.
  • Kang, N.
  • Martinez-Mckinney, F.
  • Paddock, Q.
  • Ullán Comes, Miguel
  • Unno, Y.
  • Yarwick, J.
The ATLAS collaboration is upgrading its detector for High-Luminosity LHC (HL-LHC) operations scheduled to start in 2029. This involves making a new all-silicon tracker, called Inner Tracker (ITk), with instrumented strip area of 165 m<sup>2</sup>. The strip sensor type is n-on-p, chosen because of its radiation hardness and a relative fabrication simplicity. So far, this technology has not been used in large-scale experiments. Many years of R&D investigations and pre-production experience showed that it works well, with the specification of the maximum operational voltage of 500 V. The sensors, however, show sensitivity to ambient humidity, e.g. reduced breakdown voltage at relative humidity (RH) values of about 40% and above. This is an issue for testability, but not for real operations, where RH is very low. Therefore, the collaboration adopted the strategy of dry storage, testing, and shipment for sensors and related assembled components: modules, staves, and petals. A few days long exposure to ambient air during assembly was shown to be tolerable. The dry handling strategy becomes much more difficult to implement during the tracker integration, when barrels and disks are put together in large-size cleanrooms with RH range between 50 and 70%. The duration of each of numerous integration steps is several weeks, followed by testing. The effect of such long humidity exposures on the sensor properties was unknown. Therefore, we commenced a study of repeated sensor exposures to 75% RH. We chose 32 sensors for the study from different deliveries, and with different pedigrees in terms of initial performance on reception and recovery procedures used. Progressively longer exposures ranged between 4 and 266 days in duration. The cumulative exposure time was up to 2 years. No performance deterioration was seen, as evaluated by the visual inspection, IV characteristics, and other checks. We report the details of the tests, results, and implications., Funding text 1 The research was supported and financed in part by USA Department of Energy, Grant DE-SC0010107, the Spanish R&D grant PID2021-126327OB-C22, funded by MCIN/AEI/10.13039/501100011033/FEDER, UE, and by the Canada Foundation for Innovation and the Natural Sciences and Engineering Research Council of Canada. Copyright 2024 CERN for the benefit of the ATLAS Collaboration. Reproduction of this article or parts of it is allowed as specified in the CC-BY-4.0 license. Funding text 2 The research was supported and financed in part by USA Department of Energy , Grant DE-SC0010107 , the Spanish R&D grant PID2021-126327OB-C22 , funded by MCIN/AEI/10.13039/501100011033/FEDER , UE , and by the Canada Foundation for Innovation and the Natural Sciences and Engineering Research Council of Canada., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Analysis of the quality assurance results from the initial part of production of the ATLAS18 ITK strip sensors

  • Bach, È
  • Bernabeu, J.
  • Bhardwaj, A.
  • Cindro, V.
  • Crick, B.
  • Fadeyev, V.
  • Fernández-Tejero, Javier
  • Fleta, Celeste
  • Gallus, P.
  • Hara, K.
  • Hirose, S.
  • Ishii, T.
  • Kanda, M.
  • Kasum, A.
  • Kroll, J.
  • Kvasnicka, J.
  • Lacasta, C.
  • Mahajan, C. K.
  • Mandić, I.
  • Mikestikova, M.
  • Mikuž, M.
  • Nakamura, K.
  • Orr, R. S.
  • Sato, K.
  • Slavikova, E. A.
  • Solaz, C.
  • Soldevila, U.
  • Tuma, P.
  • Ullán Comes, Miguel
  • Unno, Y.
The production of strip sensors for the ATLAS Inner Tracker (ITk) started in 2021. Since then, a Quality Assurance (QA) program has been carried out continuously, by using specific test structures, in parallel to the Quality Control (QC) inspection of the sensors. The QA program consists of monitoring sensor-specific characteristics and the technological process variability, before and after the irradiation with gammas, neutrons, and protons. After two years, half of the full production volume has been reached and we present an analysis of the parameters measured as part of the QA process. The main devices used for QA purposes are miniature strip sensors, monitor diodes, and the ATLAS test chip, which contains several test structures. Such devices are tested by several sites across the collaboration depending on the type of samples (non-irradiated components or irradiated with protons, neutrons, or gammas). The parameters extracted from the tests are then uploaded to a database and analyzed by Python scripts. These parameters are mainly examined through histograms and time-evolution plots to obtain parameter distributions, production trends, and meaningful parameter-to-parameter correlations. The purpose of this analysis is to identify possible deviations in the fabrication or the sensor quality, changes in the behavior of the test equipment at different test sites, or possible variability in the irradiation processes. The conclusions extracted from the QA program have allowed test optimization, establishment of control limits for the parameters, and a better understanding of device properties and fabrication trends. In addition, any abnormal results prompt immediate feedback to a vendor., Funding text 1 This work was supported by the Spanish R&D grant PID2021-126327OB-C22, funded by MCIN/AEI/10.13039/501100011033/FEDER, UE; the Canada Foundation for Innovation and the Natural Sciences and Engineering Research Council of Canada; the US Department of Energy, grant DE-SC0010107; the Spanish R&D grant PID2021-126327OB-C21, funded by MCIN/AEI/10.13039/501100011033/FEDER, UE; the European Structural and Investment Funds and the Czech Ministry of Education, Youth and Sports of the Czech Republic via projects LM2023040 CERN-CZ, LTT17018 Inter-Excellence, and FORTE - CZ.02.01.01/00/22_008/0004632; the gamma irradiation facility UJP PRAHA a.s.; the JSPS KAKENHI Grant Number 20K22346, 23K13114; and the Slovenian Research and Innovation Agency (research core funding No. P1-0135 and project No. J1-3032). The authors would also like to thank the crew at the TRIGA reactor in Ljubljana for help with irradiations. Funding text 2 This work was supported by the Spanish R&D grant PID2021-126327OB-C22, funded by MCIN/ AEI/10.13039/501100011033 / FEDER, UE; the Canada Foundation for Innovation and the Natural Sciences and Engineering Research Council of Canada; the US Department of Energy, grant DE-SC0010107; the Spanish R&D grant PID2021-126327OB-C21, funded by MCIN/ AEI/10.13039/501100011033 / FEDER, UE; the European Structural and Investment Funds and the Czech Ministry of Education, Youth and Sports of the Czech Republic via projects LM2023040 CERN-CZ, LTT17018 Inter-Excellence, and FORTE - CZ.02.01.01/00/22_008/0004632.; the gamma irradiation facility UJP PRAHA a.s.; the JSPS KAKENHI Grant Number 20K22346, 23K13114; and the Slovenian Research and Innovation Agency (research core funding No. P1-0135 and project No. J1-3032). The authors would also like to thank the crew at the TRIGA reactor in Ljubljana for help with irradiations., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Feasibility study of CSNS as an ATLAS ITk sensor QA irradiation site

  • Li, Hui
  • Li, Zhan
  • Wang, Shudong
  • Xu, Zijun
  • Chen, Xin
  • Xia, Mingming
  • Huang, Yingjun
  • Liu, Yang
  • Tan, Zhixin
  • Jing, Hantao
  • Xiao, Suyu
  • Fadeyev, Vitaliy
  • Ullan, Miguel
  • Unno, Yoshinobu
  • Shi, Xin
The current ATLAS Inner Detector will undergo a complete upgrade in order to meet the requirements of the High Luminosity Large Hadron Collider (HL-LHC). The new Inner Tracker (ITk) will be made completely of silicon sensors fabricated by Hamamatsu Photonics K.K. (HPK). Quality Assurance (QA) is focused on providing confidence that quality requirements will be fulfilled in production such as irradiation tolerance and testing specification for the mini sensors. The Associated Proton beam Experiment Platform (APEP) beam line at the China Spallation Neutron Source (CSNS) was commissioned in 2022. This study focused on verifying the feasibility of CSNS as an ITk sensor QA irradiation site. A low-temperature Peltier cold box has been developed to keep the irradiation sensor samples at −15 °C. Several fluence points have been studied from 5.1×10<sup>14</sup> n<inf>eq</inf>/cm<sup>2</sup> to 1.6×10<sup>15</sup> n<inf>eq</inf>/cm<sup>2</sup>, measured with the activation of the aluminium foils. The post-irradiation measurements (IV, CV, and CCE) are done under cold temperatures (−8 °C for IV and CV, −20 °C for CCE), after annealing for 80 min at 60 °C. Test results show CSNS could be a suitable proton irradiation site for the ATLAS ITk sensor project, after formal site qualification., This work was supported by Tsinghua University Initiative Scientific Research Program and National Natural Science Foundation of China (No. 11961141014). Preparation of the QA pieces is supported by the Spanish R&D grant PID2021-126327OB-C22, funded by MCIN/ AEI/10.13039/501100011033/FEDER, UE and ATLAS ITk strip sensor community. The work at SCIPP was supported by the US Department of Energy, grant DE-SC0010107., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Hot spot visual evaluation of breakdown locations in ATLAS18 ITk strip sensors and test structures

  • Fournier, A.
  • Fadeyev, V.
  • Fernández-Tejero, Javier
  • Hommels, B.
  • Jessiman, C.
  • Keller, J.
  • Klein, C.
  • Koffas, T.
  • O'Toole, S.
  • Osieja, J.
  • Poley, L.
  • Staats, E.
  • Stelzer, B.
  • Ullán Comes, Miguel
  • Unno, Y.
An important characteristic of silicon-based particle detectors, such as those used for the forthcoming ATLAS ITk upgrade for the HL-LHC, is the leakage current. This characteristic is evaluated in the quality control stage of the new ITk strip sensors by performing an IV measurement, where the sensors are biased up to −700V, typically showing low and stable leakage current. However, some sensors can exhibit a sudden leakage current increase during the IV measurement, so-called early breakdown, making the sensor unusable. The analysis of these early breakdown conditions typically consists of visual inspection of the sensors using a microscope, as often this is caused by physical damage, such as a deep scratch, chipping on the edges of the sensor, or other damage. However, the association of the observed damage with the early breakdown is not definitive. Rather, this is an association by correlation, due to the limits of verification by observation with standard equipment. A hot spot imaging setup has proven to be a valuable diagnostic tool to identify and understand these early breakdown conditions and elaborate on former understandings of these emissions. The regions responsible for the breakdown can be properly located by imaging the near infra-red light emissions produced by them in breakdown conditions. These regions of interest can also be imaged at magnification to evaluate the more precise structure of the breakdown to better understand the damage. The regions discovered, which have improved our understanding of breakdown damage and its symptoms, include scratches, chipping, static charge buildup and fabrication defects in the ATLAS18 strip sensors and test structures., Funding text 1 This work was supported by the Canada Foundation for Innovation and the Natural Sciences and Engineering Research Council of Canada. This work is part of the Spanish R&D grant PID2021-126327OB-C22, funded by MCIN/ AEI/ 10.13039/501100011033/FEDER, UE. The work at SCIPP was supported by the US Department of Energy, grant DE-SC0010107. Copyright 2024 CERN for the benefit of the ATLAS Collaboration. Reproduction of this article or parts of it is allowed as specified in the CC-BY-4.0 license. Funding text 2 This work was supported by the Canada Foundation for Innovation and the Natural Sciences and Engineering Research Council of Canada . This work is part of the Spanish R&D grant PID2021-126327OB-C22 , funded by MCIN/ AEI/ 10.13039/501100011033/FEDER , UE. The work at SCIPP was supported by the US Department of Energy , grant DE-SC0010107 ., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Identification and recovery of ATLAS18 strip sensors with high surface static charge, e

  • Staats, Ezekiel
  • Affolder, A.
  • Beck, G. A.
  • Bevan, A. J.
  • Chen, Z.
  • Dawson, I.
  • Deshmukh, A.
  • Dowling, A.
  • Duvnjak, D.
  • Fadeyev, V.
  • Federicova, P.
  • Fernández-Tejero, Javier
  • Fournier, A.
  • Gonzalez, N.
  • Jessiman, C.
  • Kachiguin, S.
  • Keller, J.
  • Klein, C. T.
  • Koffas, T.
  • Kroll, J.
  • Kvasnicka, J.
  • Latonova, V.
  • Martinez-Mckinney, F.
  • Mikestikova, M.
  • Miyagawa, P. S.
  • O'Toole, S.
  • Paddock, Q.
  • Poley, L.
  • Slavikova, E. A.
  • Stelzer, B.
  • Tuma, P.
  • Ullán Comes, Miguel
  • Unno, Y.
  • Westbrook, C.
  • Zenz, S. C.
The new all-silicon Inner Tracker (ITk) is being constructed by the ATLAS collaboration to track charged particles produced at the High-Luminosity LHC. The outer portion of the ITk detector will include nearly 18,000 highly segmented and radiation hard silicon strip sensors (ATLAS18 design). Throughout the production of 22,000 sensors, the strip sensors are subjected to a comprehensive suite of mechanical and electrical tests as part of the Quality Control (QC) program. In a large fraction of the batches delivered to date, high surface electrostatic charge has been measured on both the sensors and the plastic sheets between which the sensors are packaged for shipping and handling rigidity. Aggregate data from across QC sites indicate a correlation between observed electrical failures and the sensor/plastic sheet charge build up. To mitigate these issues, the QC testing sites introduced recovery techniques involving UV light or flows of ionizing gas. Significant modifications to sensor handling procedures were made to prevent subsequent build up of static charge. This publication details a precise description of the issue, a variety of sensor recovery techniques, and trend analyses of sensors initially failing electrical tests (IV, strip scan, etc.)., Funding text 1 This work was supported by the Canada Foundation for Innovation and the Natural Sciences and Engineering Research Council of Canada ; is part of the Spanish R&D grant PID2021-126327OB-C22 , funded by MCIN/AEI/10.13039/501100011033/FEDER , UE; at SCIPP was supported by the US Department of Energy , grant DE-SC0010107 ; at QMUL was supported by STFC grants ST/W000474/1 , ST/S00095X/1 , ST/X001431/1 , ST/R00241X/1 ; was supported by the European Structural and Investment Funds and the Czech Ministry of Education, Youth and Sports of the Czech Republic via projects LM2023040 CERN-CZ, LTT17018 Inter-Excellence, and FORTE - CZ.02.01.01/00/22_008/0004632 . Funding text 2 This work was supported by the Canada Foundation for Innovation and the Natural Sciences and Engineering Research Council of Canada; is part of the Spanish R&D grant PID2021-126327OB-C22, funded by MCIN/AEI/10.13039/501100011033/FEDER, UE; at SCIPP was supported by the US Department of Energy, grant DE-SC0010107; at QMUL was supported by STFC grants ST/W000474/1, ST/S00095X/1, ST/X001431/1, ST/R00241X/1; was supported by the European Structural and Investment Funds and the Czech Ministry of Education, Youth and Sports of the Czech Republic via projects LM2023040 CERN-CZ, LTT17018 Inter-Excellence, and FORTE - CZ.02.01.01/00/22_008/0004632. Copyright 2024 CERN for the benefit of the ATLAS Collaboration. Reproduction of this article or parts of it is allowed as specified in the CC-BY-4.0 license., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Development of silicon interposers with embedded microchannels and metal re-distribution layer for the integration of hybrid detector systems

  • Ullán, Miguel
  • Correa, Jonathan
  • Dauderys, Vainius
  • Díez, Sergio
  • Duch, Marta
  • Boto, Luis
  • Martínez, Leyre
  • Mas, Roser
  • Ruiz Moreno, Alberto
One of the important challenges in the current radiation detector applications, as we advance in the further integration of the systems, is the cooling of the detectors. The larger heat densities, combined with the complexity of hybrid detector assemblies, complicate the full integration of the sensors, electronics, and services in the whole system. In order to overcome these difficulties microchannel cooling has been proposed to increase the cooling efficiency, reducing the heat transfer path to the detector volume and therefore increasing the heat removal performance, while improving the integration of the cooling with the detector and front-end electronics hybrid system. In this work, we present the development and fabrication of silicon interposers with embedded microchannels, which also incorporate a metal re-distribution layer (RDL) to contribute further in the integration of the system. These interposers are proposed for their application both in future high energy physics experiments and for advanced systems in photon science where the thermal, material, and integration requirements are very demanding, therefore they can benefit from these developments. The microchannels and the metal tracks are created in several fabrication steps which are described. Two methods have been followed to produce these interposers, called “pre-processing” and "post-processing", depending on whether the microchannels are created before or after the metal lines. The multiple analysis techniques used to evaluate the different fabrication methods and to assess the final quality of the interposers are presented and the results discussed. Additional considerations are made on the potential of alternative technologies available to create interposers for further applications. With the advent of the Through Silicon Vias (TSV) technology, the proposed solution would provide further alternatives for the electrical interconnection of the detector/electronics hybrid with the external world, facilitating the signal and power input/output., Funding text 1 This work is part of the Spanish R&D grant PID2021-126327OB-C22, funded by MCIN/AEI/10.13039/501100011033 and by ERDF/EU a way of making Europe. Additionally, this project has received funding from the European Union's Horizon 2020 Research and Innovation programme under Grant Agreement no 101004761. Funding text 2 This work is part of the Spanish R&D grant PID2021-126327OB-C22, funded by MCIN/ AEI/10.13039/501100011033 and by ERDF/UE A way of making Europe. Additionally, this project has received funding from the European Union's Horizon 2020 Research and Innovation programme under GA no 101004761., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Preliminary defect level investigation in ATLAS ITk Strip Sensors using DLTS

  • Klein, C. T.
  • Dandoy, J.
  • Duvnjak, D.
  • Fadeyev, V.
  • Hara, K.
  • Hirose, S.
  • Jessiman, C.
  • Keller, J. S.
  • Koffas, T.
  • Nakamura, K.
  • Staats, E.
  • Ullán Comes, Miguel
  • Unno, Y.
  • Vandusen, R.
As a part of ongoing studies in parallel to ITk Strip Sensor Production quality control (QC) and quality assurance (QA), diodes fabricated as test structures were measured using Deep-Level Transient Spectroscopy (DLTS). This was done to understand an anomalously large leakage current observed in main sensors, and to improve the precision of sensor simulations as well as to compile a more complete model of radiation damage in ITk Strip Sensors. Utilising DLTS spectra with varying test parameters, trap energy levels and cross-sections associated with defects in the devices were obtained. Furthermore, employing related measurements techniques, such as Thermal Admittance Spectroscopy (TAS), results were supplemented and expanded, or additional points of interest, such as the deep level profile and the capture kinematics of the trap levels, were investigated with double-pulse DLTS (DDLTS). A common trap in unirradiated diodes was identified, but also an additional trap suspected to cause high leakage current. In proton-irradiated diodes, defects common to all devices irrespective of fluence level were observed., Funding text 1 This work was supported by the Canada Foundation for Innovation and the Natural Sciences and Engineering Research Council of Canada; the Spanish R&D grant PID2021-126327OB-C22, funded by MCIN/ AEI/10.13039/501100011033/FEDER, UE; the US Department of Energy, grant DE-SC0010107; the Grant-in-Aid for scientific research on advanced basic research (Grant No. 19H05193, 19H04393, 21H0073 and 21H01099) from the Ministry of Education, Culture, Sports, Science and Technology, of Japan. In keeping the research program move forward, the Cyclotron Radio Isotope Center (CYRIC) at Tohoku University was very important to this project. Copyright 2024 CERN for the benefit of the ATLAS Collaboration. Reproduction of this article or parts of it is allowed as specified in the CC-BY-4.0 license. Funding text 2 This work was supported by the Canada Foundation for Innovation and the Natural Sciences and Engineering Research Council of Canada ; the Spanish R&D grant PID2021-126327OB-C22 , funded by MCIN/ AEI/10.13039/501100011033/FEDER , UE; the US Department of Energy , grant DE-SC0010107 ; the Grant -in-Aid for scientific research on advanced basic research (Grant No. 19H05193 , 19H04393 , 21H0073 and 21H01099 ) from the Ministry of Education, Culture, Sports, Science and Technology, of Japan . In keeping the research program move forward, the Cyclotron Radio Isotope Center (CYRIC) at Tohoku University was very important to this project., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Defect investigation in irradiated ATLAS18 ITk Strip Sensors using transient spectroscopy techniques

  • Klein, C. T.
  • Cindro, V.
  • Dandoy, J.
  • Fadeyev, V.
  • Federičová, P.
  • Jessiman, C.
  • Keller, J. S.
  • Koffas, T.
  • Kroll, J.
  • Kvasnička, J.
  • Mandić, I.
  • Mikeštíková, M.
  • Staats, E.
  • Ullán Comes, Miguel
  • Unno, Y.
  • Zhao, Y.
With the upgrade of the LHC to the High-Luminosity LHC (HL-LHC), the Inner Detector will be replaced with the new all-silicon ATLAS Inner Tracker (ITk). Comprising an active area of 165m<sup>2</sup>, the outer detector layers will host strip modules, built with single-sided micro-strip sensors. The ATLAS18 main sensors were tested at different institutes in the collaboration for mechanical and electrical compliance with technical specifications, while technological parameters were verified on test structures from the same wafers before and after irradiation. Diodes fabricated as test structures were studied using variants of Deep-Level Transient Spectroscopy (DLTS). Irradiated diode samples were measured with Current-DLTS, using both electrical and photo-induced injection. Utilizing DLTS spectra with varying test parameters, trap energy levels and cross-sections associated with defects were obtained. This was done to improve the precision of sensor simulations as well as to compile a more complete model of radiation damage in ITk Strip Sensors. Moreover, previously observed features such as an increasing trend in the full depletion voltage after irradiation and little beneficial annealing in charge collection after high fluence irradiation of high energy protons were also investigated. Results obtained for samples with radiation damage from different sources at various fluences were compared., Funding text 1 This work was supported by the Canada Foundation for Innovation and the Natural Sciences and Engineering Research Council of Canada; the Spanish R&D grant PID2021-126327OB-C22, funded by MCIN/AEI/10.13039/501100011033/FEDER, UE; the US Department of Energy, grant DE-SC0010107; the European Structural and Investment Funds and the Ministry of Education, Youth and Sports of the Czech Republic via projects LM2023040 CERN-CZ, and FORTE - CZ.02.01.01/00/22_008/0004632. In keeping the research program move forward, the Cyclotron Radio Isotope Center (CYRIC) at Tohoku University was very important to this project. The authors would like to thank the crew at the TRIGA reactor in Ljubljana for help with irradiations. The authors acknowledge the financial support from the Slovenian Research and Innovation Agency (research core funding No. P1-0135 and project No. J1-3032). Copyright 2025 CERN for the benefit of the ATLAS Collaboration. Reproduction of this article or parts of it is allowed as specified in the CC-BY-4.0 license. Funding text 2 This work was supported by the Canada Foundation for Innovation and the Natural Sciences and Engineering Research Council of Canada ; the Spanish R&D grant PID2021-126327OB-C22 , funded by MCIN/AEI/10.13039/501100011033/FEDER, UE ; the US Department of Energy , grant DE-SC0010107 ; the European Structural and Investment Funds and the Ministry of Education, Youth and Sports of the Czech Republic via projects LM2023040 CERN-CZ , and FORTE - CZ.02.01.01/00/22_008/0004632 . In keeping the research program move forward, the Cyclotron Radio Isotope Center (CYRIC) at Tohoku University was very important to this project. The authors would like to thank the crew at the TRIGA reactor in Ljubljana for help with irradiations. The authors acknowledge the financial support from the Slovenian Research and Innovation Agency (research core funding No. P1-0135 and project No. J1-3032)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Irradiation study using QA test pieces of ATLAS18 ITk strip sensors with 80 MeV protons

  • Huang, Y.
  • Li, H.
  • Cai, M.
  • Chisholm, A. S.
  • Cindro, V.
  • Crick, B.
  • Deng, H.
  • Fadeyev, V.
  • Hirose, S.
  • Jiang, B.
  • Jing, H.
  • Liu, H.
  • Liu, P.
  • Liu, Y.
  • Lu, W.
  • Mandić, I.
  • Orr, R. S.
  • Shi, X.
  • Tan, Z.
  • Ullán Comes, Miguel
  • Unno, Y.
  • Wang, S.
  • Xu, Z.
The ATLAS experiment is planning a complete replacement of its inner detector (ID) with a new all-silicon inner tracker (ITk) for the ATLAS Phase-2 upgrade. The ATLAS18 silicon strip sensors are designed to operate up to the integrated luminosity of 4000 fb<sup>−1</sup>, which corresponds to the maximum fluence of 1.6×10<sup>15</sup>n<inf>eq</inf>/cm<sup>2</sup> (including safety factor). To enhance the quality assurance (QA) program to monitor the key properties of the sensors, the strip sensor community is considering to include China Spallation Neutron Source (CSNS) as a proton irradiation site and Institute of High Energy Physics (IHEP) as a QA test site. A total of 18 ATLAS18 ITk QA test pieces were irradiated with 6.0×10<sup>14</sup>, 1.6×10<sup>15</sup>, and 2.6×10<sup>15</sup>n<inf>eq</inf>/cm<sup>2</sup> protons at CSNS, and measured at IHEP, including IV (leakage current–voltage), CV (capacitance–voltage) and CCE (charge collection efficiency) measurements. The upgraded irradiation setup at CSNS and measurement setup at IHEP are shown in this paper. Irradiated samples were exchanged between IHEP, Ljubljana and Birmingham to cross-check CCE measurements., The research was supported and financed in large part by the National Key Research and Development Program of China under Grant No. 2023YFA1605902 from the Ministry of Science and Technology; Project W2443002 supported by National Natural Science Foundation of China ; Guangdong Provincial Key Laboratory of Advanced Particle Detection Technology, China ( 2024B1212010005 ); High-performance Computing Public Platform (Shenzhen Campus) of SUN YAT-SEN UNIVERSITY, China ; Project of Gamma\u2013Gamma Collider and Integrated Beam Flow Facility (Phase I) Validation Device at SYSU ( 2403-000000-05-03-714165 ); the Slovenian Research and Innovation Agency (research core funding No. P1-0135 and project No. J1-3032 ); the Spanish R&D grant PID2021-126327OB-C22 , funded by MICIU/ AEI/10.13039/501100011033 and by ERDF/EU ; the work at SCIPP supported by the US Department of Energy , grant DE-SC0010107 ; the Canada Foundation for Innovation and the Natural Sciences and Engineering Research Council of Canada . Copyright 2025 CERN for the benefit of the ATLAS Collaboration. Reproduction of this article or parts of it is allowed as specified in the CC-BY-4.0 license., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Evolution of the electrical characteristics of the ATLAS18 ITk strip sensors with HL-LHC radiation exposure range

  • Fernández-Tejero, Javier
  • Bach, I.
  • Cindro, V.
  • Fadeyev, V.
  • Federičová, P.
  • Fleta, Celeste
  • Hirose, S.
  • Kroll, J.
  • Mandić, I.
  • Maeyama, K.
  • Mikeštíková, M.
  • Poley, L.
  • Stelzer, B.
  • Tuma, P.
  • Ullán Comes, Miguel
  • Unno, Y.
The objective of the study is to evaluate the evolution of the performance of the new ATLAS Inner-Tracker (ITk) strip sensors as a function of radiation exposure, to ensure the proper operation of the upgraded detector during the lifetime of the High-Luminosity Large Hadron Collider (HL-LHC). Full-size ATLAS ITk Barrel Short-Strip (SS) sensors with final layout design, ATLAS18SS, have been irradiated with neutrons and gammas, to confirm the results obtained with prototypes and miniature sensors during the development phase. The irradiations cover a wide range of fluences and doses that ITk will experience, going from 1×10<sup>13</sup> n<inf>eq</inf>/cm<sup>2</sup> and 0.49 Mrad, to 1.6×10<sup>15</sup> n<inf>eq</inf>/cm<sup>2</sup> and 80 Mrad. The split irradiation enables a proper combination of fluence and dose values of the HL-LHC, including a 1.5 safety factor. A complete electrical characterization of the key sensor parameters before and after irradiation is presented, studying the leakage current, bulk capacitance, single-strip and inter-strip characteristics. The results confirm the fulfilment of the ATLAS specifications throughout the whole experiment. The study of a wide range of fluences and doses also allows to obtain detailed results, such as the frequency dependence of the bulk capacitance measurements for highly irradiated sensors, or the evolution of the punch-through protection and inter-strip resistance with radiation., The work at SFU and TRIUMF was supported by the Canada Foundation for Innovation and the Natural Science and Engineering Research Council of Canada. The work at IMB-CNM is part of the Spanish R&D grant PID2019-126327OB-C22, funded by MCIN/AEI/10.13039/501100011033 and by ERDF/EU. The work at SCIPP was supported by the US Department of Energy, grant DE-SC0010107. The work at Prague was supported by the European Structural and Investment Funds and the Czech Ministry of Education, Youth and Sports of the Czech Republic via projects LM2023040 CERN-CZ, LTT17018 Inter-Excellence, and FORTE – CZ.02.01.01/00/22-008/0004632. The authors would like to thank the crew at the TRIGA reactor in Ljubljana for help with irradiations. The authors acknowledge the financial support from the Slovenian Research and Innovation Agency (research core funding No. P1-0135 and project No. J1-3032). The authors would like to thank the technical team at the Cyclotron and Radioisotope Center (CYRIC) of Tohoku University (Japan) for proton irradiation. This work was supported by JSPS KAKENHI Grant Number 23 K13114., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Unusual annealing of charge collection efficiency of silicon strip detectors, ATLAS18, irradiated to high fluences with 23 GeV protons

  • Mandić, I.
  • Cindro, V.
  • Kramberger, G.
  • Mikuž, M.
  • Puklavec, M.
  • Federičová, P.
  • Jirásek, R.
  • Kroll, J.
  • Kvasnička, J.
  • Mikeštíková, M.
  • Tůma, P.
  • Fadeyev, V.
  • Unno, Y.
  • Ullan, M.
  • Soldevila, Urmila
  • Lacasta Llácer, Carlos
  • Solaz, Carles
  • Bernabeu Verdú, José
  • Orr, R.S.
  • Crick, B.
  • Epstein, U.
  • P'yavka, S.
  • Wishart, P.
  • Klein, C.T.
  • Dandoy, J.
  • Keller, J.
  • Staats, E.
  • Jessiman, C.
  • Koffas, T.
  • Zhao, Y.
  • Chisholm, A.S.
  • Scharf, C.
Extensive studies were performed on highly irradiated ATLAS18 mini strip detectors to evaluate their annealing behaviour. Collected charge was measured after several steps of annealing at 60 °C. For detectors irradiated with neutrons or low energy protons the collected charge exhibited a beneficial effect of short-term annealing which was followed by a decrease in charge collection efficiency at longer annealing times. After irradiation with 23 GeV protons to fluences above Φeq∼1.2⋅1015 cm−2, the collected charge remained unchanged or decreased after the first few tens of minutes of annealing. Edge-TCT measurements indicated that this unusual annealing behaviour is related to the double-peak electric field profile in the detector. Mixed irradiation with 23 GeV protons and neutrons to fluences matching the expected in the upgraded ATLAS experiment showed this unusual annealing effect will not impact the operation of the ITk strip detector. © 2025 The Authors, The authors acknowledge the financial support from the Slovenian Research and Innovation Agency (research core funding No. P1-0135 and project No. J1-3032). This work is part of the Spanish R&D grant PID2021-126327OB-C22, funded by MICIU/ AEI/10.13039/501100011033 and by ERDF/EU and part of the Spanish R&D grant PID2021-126327OB-C21, funded by MCIN/ AEI/10.13039/501100011033/FEDER, UE. The work at SCIPP was supported by the US Department of Energy, grant DE-SC0010107. This work was supported by the European Structural and Investment Funds and the Ministry of Education, Youth and Sports of the Czech Republic via projects LM2023040 CERN-CZ, and FORTE-CZ.02.01.01/00/22_008/0004632. The work was supported by the Canada Foundation for Innovation under project number 36248, additional resources were provided by the Natural Sciences and Engineering Research Council of Canada . The authors would like to thank the crews at the TRIGA reactor in Ljubljana, the IRRAD facility at CERN and the MC40 Cyclotron Facility at Birmingham for help with irradiations., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Analysis of MOS capacitor with p layer with TCAD simulation

  • Unno, Y.
  • Bach, Eric
  • Dandoy, J.
  • Fadeyev, V.
  • Fleta, Celeste
  • Jessiman, C.
  • Keller, J.
  • Klein, C. T.
  • Koffas, T.
  • Staats, E.
  • Ullán Comes, Miguel
The ATLAS18 strip sensors of the ATLAS inner tracker upgrade (ITk) are in production since 2021. Along with the large-format n<sup>+</sup>-in-p strip sensor in the center of 6-inch wafer, test structures including Metal–Oxide–Silicon (MOS) capacitors are laid out in the open space for monitoring the performance of the strip sensor and its fabrication process. One of the MOS capacitors is with a p-implantation in the surface of silicon to access the p-stop doping for isolating the n<sup>+</sup> strips, the MOS-p capacitor. The capacitance measurement of the standard MOS capacitor as a function of gate voltage (C–V) shows characteristic behavior in the accumulation, depletion, and inversion regimes, from which one can deduce the amount of the interface charge. The MOS-p capacitor shows the C–V characteristics modulated by the properties of the p-layer. With over 50% of the full production complement delivered, we have observed consistent characteristics in the MOS-p capacitors. Rarely and currently only in three incidents, we have observed anomalous behaviors which implied lower density of p-layer. To study the cause, we have simulated the MOS-p capacitor with a TCAD device simulator. The normal characteristic curve is reproduced successfully with p-density and interface charge within the expected ranges, including a feature caused by a geometrical offset. The anomalous C–V characteristics cannot be explained simply by low p-density, but instead explained with the p-layer density near the specification which goes to zero at the surface. The loss of density could have been introduced with an n-type surface contamination or some other effect such as “dopant segregation”. These simulations have helped to take final acceptance decisions for the batches in production., Funding text 1 We gratefully acknowledge HPK for their close communication and collaboration. This work is supported in part by the Canada Foundation for Innovation and the Natural Science and Engineering Research Council of Canada , as well as the Alexander von Humboldt Foundation , the Spanish R&D grant PID2021-126327OB-C22 , funded by MCIN/ AEI/ 10.13039/501100011033/FEDER , UE, and the US Department of Energy , grant DE-SC0010107 . Funding text 2 We gratefully acknowledge HPK for their close communication and collaboration. This work is supported in part by the Canada Foundation for Innovation and the Natural Science and Engineering Research Council of Canada, as well as the Alexander von Humboldt Foundation, the Spanish R&D grant PID2021-126327OB-C22, funded by MCIN/AEI/10.13039/501100011033 and by ERDF/EU, and the US Department of Energy, grant DE-SC0010107. Copyright 2024 CERN for the benefit of the ATLAS Collaboration. Reproduction of this article or parts of it is allowed as specified in the CC-BY-4.0 license., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Low dose gamma irradiation study of ATLAS ITk MD8 diodes

  • Mikeštíková, M.
  • Fadeyev, V.
  • Federičová, P.
  • Gallus, P.
  • Kozáková, J.
  • Kroll, J.
  • Kůtová, M.
  • Kvasnička, J.
  • Tůma, P.
  • Ullán Comes, Miguel
  • Unno, Y.
Silicon strip detectors developed for the Inner Tracker (ITk) of the ATLAS experiment will operate in a harsh radiation environment of the HL-LHC accelerator. The ITk is thus designed to endure a total fluence of 1.6 × 10<sup>15</sup> 1-MeV n<inf>eq</inf>/cm<sup>2</sup> and a total ionizing dose (TID) of 66 Mrad in the strip detector region. A radiation-hard n <sup>+</sup>-in-p technology is implemented in the ITk strip sensors. To achieve the required radiation hardness, extensive irradiation studies were conducted during sensor development, primarily performed up to the maximal expected total fluence and TID to ensure the full functionality of the detector at its end-of-life. These studies included irradiations of sensors with various particle types and energies, including the <sup>60</sup>Co γ-rays. Our previous results obtained for γ-irradiated diodes and strip sensors indicate a linear increase of bulk current with TID, while the surface current saturates at the lowest TID levels checked (66 Mrad), preventing a determination of the exact TID for which the observed saturation occurs. This work presents the results coming from irradiations by <sup>60</sup>Co γ-rays to multiple low TIDs, ranging from 0.5 to 100 krad. The detailed study of total, bulk, and surface currents of diodes explores an unknown dependence of surface current on the TID, annealing, and temperature. Additionally, the effect of the p-stop implant between the bias and the guard ring of measured samples is shown. The observations are relevant for the initial operations of the new ATLAS tracker., This work was supported by the European Structural and Investment Funds and the Ministry of Education, Youth and Sports of the Czech Republic via projects LM2023040 CERN-CZ and FORTE - CZ.02.01.01/00/22_008/0004632, by the US Department of Energy, grant DE-SC0010107, and the Spanish R&D grant PID2021-126327OB-C22, funded by MICIU/ AEI/10.13039/501100011033 and by ERDF/EU., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Evaluation of performance of the p-stop fabrication process variations in ATLAS18 strip sensors, pre- and post-irradiation

  • Kozáková, J.
  • Affolder, A.
  • Affolder, K.
  • Awais, A.
  • Bach, E.
  • Beck, G.A.
  • Bernabeu Verdú, Pepe
  • Bevan, A.J.
  • Chen, Z.
  • Cindro, V.
  • Crick, B.
  • Dandoy, J.
  • Dawson, I.
  • Fadeyev, V.
  • Federičová, P.
  • Fleta, C.
  • Gallus, P.
  • Jessiman, C.
  • Katznelson, S.
  • Keller, J.
  • Klein, C.T.
  • Koffas, T.
  • Kroll, J.
  • Kůtová, M.
  • Kvasnička, J.
  • Lacasta Llácer, Carlos
  • Mandić, I.
  • Gregorio, R.R.M.
  • Martinez-McKinney, F.
  • Mikeštíková, M.
  • Miyagawa, P.S.
  • Morelos-Zaragoza, L.
  • Orr, R.S.
  • Paddock, Q.
  • Solaz, Carles
  • Soldevila, Urmila
  • Staats, E.
  • Tůma, P.
  • Ullán Comes, Miguel
  • Unno, Y.
  • Vansteenkiste, M.
  • Wishart, P.
  • Zenz, S.C.
  • Zhao, Y.
The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) requires the replacement of the ATLAS Inner Detector with a new all-silicon Inner Tracker (ITk). Radiation-hard n+-in-p micro-strip sensors were developed for use in the ITk. During quality control (QC) and quality assurance (QA) procedures performed on ATLAS18 production sensors and test chips, ATLAS ITk strip sensor institutes identified instances of low p-stop density in certain production batches. To investigate the origin of these issues and to try some technological improvements, two dedicated sample batches with four variations of the p-stop fabrication process were produced. These process types (1–4) were systematically evaluated to determine their effectiveness and uniformity. In total, 56 full-size sensors, along with numerous miniature sensors and test chips, were tested. A number of samples were used in the irradiation campaign reaching the maximum expected levels for the HL-LHC operation after 10 years — with neutrons up to 1.6×1015 neq/cm2, and with gamma rays from a 60Co source up to 66 Mrad. The goal of this evaluation program is to assess the impact of p-stop fabrication process variations on interstrip isolation performance and to provide feedback for future sensor development. This paper describes the applied test procedures and presents the corresponding results, which demonstrate good sensor performance for all investigated p-stop types. The findings confirm the reliability of the evaluated designs and identify specific advantages that can inform further optimization of strip sensor fabrication. © 2026 The Authors, This work was supported by the European Structural and Investment Funds and the Ministry of Education, Youth and Sports of the Czech Republic via projects LM2023040 CERN-CZ, and FORTE CZ.02.01.01/00/22_008/0004632, the Canada Foundation for Innovation, Canada under project number 36248; additional resources were provided by the Natural Sciences and Engineering Research Council of Canada, Canada. The authors would like to thank the crew at the TRIGA reactor in Ljubljana for help with irradiations. The authors acknowledge the financial support from the Slovenian Research and Innovation Agency (research core funding No. P1-0135 and project No. J1-3032). This work is part of the Spanish R&D grant PID2021-126327OB-C22, funded by MICIU/ AEI/10.13039/501100011033 and by ERDF/EU, R&D grant PID2021-126327OB-C21, funded by MCIN/ AEI/10.13039/501100011033/FEDER, UE. This work at QMUL was supported by STFC, United Kingdom grants ST/W000474/1, ST/S00095X/1, ST/X001431/1, ST/R00241X/1. The work at SCIPP was supported by the US Department of Energy , grant DE-SC0010107. Copyright 2026 CERN for the benefit of the ATLAS Collaboration. Reproduction of this article or parts is allowed as specified in the CC-BY-4.0 license., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Quality Assurance during production of the ATLAS18 ITk strip sensors

  • Orr, R.S.
  • Fleta, Celeste
  • Allport, P.P.
  • Awais, A.
  • Bach, Eric
  • Bhardwaj, A.
  • Bernabeu Verdú, Pepe
  • Beck, G.A.
  • Bevan, A.J.
  • Chen, Z.
  • Chisholm, A.S.
  • Cindro, V.
  • Crick, B.
  • Dawson, I.
  • Epstein, U.
  • Fadeyev, V.
  • Federicova, P.
  • Fernandez-Tejero, J.
  • Gallus, P.
  • Hill, E.C.
  • Hirose, S.
  • Klein, C.T.
  • Knight, T.
  • Kopsalis, I.
  • Kozakova, J.
  • Kroll, J.
  • Kvasnicka, J.
  • Lacasta Llácer, Carlos
  • Liu, E.
  • Lomas, J.
  • Mandic, I.
  • Maeyama, K.
  • Gregorio, R.R.M.
  • Mikestikova, M.
  • Miyagawa, P.S.
  • Nakamura, K.
  • Novak, B.
  • Pyavka, S.
  • Sato, K.
  • Skorda, E.
  • Solaz, Carles
  • Soldevila, Urmila
  • Thory-Rao, T.M.
  • Tuma, P.
  • Ullán Comes, Miguel
  • Unno, Y.
  • Valero, David
  • Vansteenkiste, M.
  • Wishart, P.
  • Zenz, S.C.
We describe the extensive quality assurance programme undertaken during the production of the ATLAS ITk strip sensors. Quality Assurance (QA) is the systematic process of preventing defects during production, rather than identifying them after the fact. QA is performed on test structures fabricated at the periphery of the same wafers used to produce the actual sensors, thus ensuring that these structures are a good representation of the sensor and process quality. The test structures consist of test chips, which include strips, diodes, MOS capacitors, and special structures for monitoring of parameters such as bias resistor values, interstrip resistance, coupling capacitance and flat band voltage. Additionally, miniature sensors with the same design as the main sensor, but with reduced area, allow measurement of the charge generated during irradiation with a beta source. Test structure semiconductor parameters are measured on both unirradiated samples and samples subjected to irradiation. The test chips are irradiated using gammas and reactor neutrons to the equivalent dose (660 kGy) and fluence (1.6×1015neq/cm2) expected in the high luminosity-LHC after 1.5 times its lifetime of 14 years. Miniature sensors are irradiated to the same neutron fluence as the test chips, or the equivalent proton fluence. Monitor diodes are irradiated alternatively to the maximum fluence to measure the degradation of the leakage current, and to one third this value to observe the full depletion voltage within the operational range of the measurement setups. Unirradiated test structures are measured on a probe station at room temperature. Irradiated test structures are wire-bonded to a PCB to provide connectivity, and measured at -21 °C and 4% relative humidity. After almost five years of sensor production, the QA process has shown reliable performance across multiple test sites. A few deviations from the acceptance criteria, such as low flat band voltage, high full depletion voltage, and variations in the magnitude and uniformity of the p-stop doping have been identified and timely reported back to the vendor. However, most of the evaluated parameters have remained within the defined specifications. We have tested ∼ 90% of the total sensor production to date. Of these, we have accepted 596 batches and rejected 6; giving a batch rejection rate of 1%. Of the six batches rejected, four are rejected due to QA issues related to low p-stop doping. © 2026, This work was supported by the European Structural and Investment Funds and the Ministry of Education, Youth and Sports of the Czech Republic via projects LM2023040 CERN-CZ, and FORTE - CZ.02.01.01/00/22_008/0004632, the Spanish R&D grant PID2021126327OBC21, funded by MCIN/ AEI/10.13039/501100011033/FEDER, UE., the Spanish R&D grant PID2021-126327OB-C22, funded by MICIU/ AEI/10.13039/501100011033 and by ERDF/EU., by STFC grants ST/W000474/1, ST/S00095X/1, ST/X001431/1, ST/R00241X/1, by JSPS KAKENHI 20K22346 and 23K13114, by the US Department of Energy, grant DE-SC0010107, by the Canada Foundation for Innovation under project number 36248; additional resources were provided by the Natural Sciences and Engineering Research Council of Canada and by the Slovenian Research and Innovation Agency (research core funding No. P1-0135 and project No. J1-3032). The authors would like to thank the crew at the Research Center for Electron Photon Science (RARiS), Tohoku University (Japan) for proton irradiation, and would like to thank the crew at the TRIGA reactor in Ljubljana for help with neutron irradiations.Copyright 2026 CERN for the benefit of the ATLAS Collaboration. Reproduction of this article or parts is allowed as specified in the CC-BY-4.0 license., Peer reviewed