Quantitative analysis of urinary volatile organic compounds by headspace solid-phase microextraction coupled to gas chromatography – mass spectrometry under low sample volume conditions

  • Cámara Valero, Esther
  • Beltrán Sanahuja, Ana
  • de-Madaria, Enrique
  • Todolí Torró, José Luis
  • Beltrán Sanahuja, Ana|||/items/e050de26-d5fa-4bc8-8092-760c0d8865d0
  • Todolí Torró, José Luis|||/items/e63cf980-21e8-48ec-8493-cdb380f1cccc
In this work, a low-sample-volume analytical method based on headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography-mass spectrometry (GC–MS) was developed and evaluated for the targeted quantification of selected volatile organic compounds (VOCs) in urine samples. Optimization of HS-SPME conditions was performed using a Box-Behnken design to evaluate the effects of incubation temperature, incubation time, and extraction time, with temperature and extraction time emerging as the most significant factors. A confirmatory experiment supported shortening the model-derived incubation time from 52 to 15 min without compromising analytical performance. Sample volume was varied from 0.01 to 5.0 mL and, after evaluating extraction efficiency, repeatability, and total analytical response, 0.1 mL was selected as the optimal compromise between analytical response, repeatability, and sample consumption. Under the selected conditions (55 °C incubation temperature, 15 min incubation time and 52 min extraction time), the method enabled reliable extraction of eight chemically diverse VOCs with different volatilities, polarities, and functional groups (including dimethyl disulfide, 4-heptanone, cyclohexanol, cyclohexanone, phenol, p-cresol, nonanoic acid, and 2,4-di‑tert-butylphenol). Cyclohexanol and nonanoic acid were excluded from the final study due to the absence of reproducible EIC peaks under the selected HS-SPME-GC–MS conditions. Method evaluation performed in simulated urine showed good linearity (R2 = 0.987 - 0.999), low limits of detection (0.04 – 22.85 μg L⁻1) and limits of quantification (0.12–76.18 µg L⁻1). Recovery experiments in two real urine samples showed acceptable quantitative performance for most analytes and conditions, although compound- and matrix-dependent deviations were observed. Matrix-related variability was further assessed using multiple headspace solid-phase microextraction (MHS-SPME), as a complementary tool to compare extraction behavior in simulated and real urine. Application to seven healthy urine samples demonstrated the analytical applicability of the method in a real biological matrix. Overall, the proposed method combines trace-level sensitivity, minimal sample consumption, quantitative validation, and applicability to chemically diverse urinary VOCs under sample-limited conditions.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

In situ hydride generation for multielement analysis in complex matrices through ICP-MS with a high-temperature sample introduction system

  • Pérez Ramírez, Rebeca
  • Sánchez, Raquel
  • Todolí Torró, José Luis
  • Sánchez, Raquel|||/items/06c6cd36-b88e-43e0-929a-9b92d670da54
  • Todolí Torró, José Luis|||/items/e63cf980-21e8-48ec-8493-cdb380f1cccc
Hydride generation (HG) remains a powerful sample introduction strategy for the determination of some elements by inductively coupled plasma mass spectrometry (ICP-MS). In this study, two HG-based configurations were systematically evaluated, including a conventional HG system with external gas-liquid separation and a structurally modified high-temperature torch-integrated sample introduction system (hTISIS). The hTISIS was equipped with an auxiliary inlet, i.e., drain tube, for the introduction of NaBH4 and HCl, allowing gas-liquid reaction and phase separation to occur directly within the thermostated spray chamber. This latter setup, HG-hTISIS, was employed under three different modes: sample introduction through both the nebulizer and the drain tube (mode 1); sample introduction only through nebulization (mode 2); and sample introduction only through the drain tube (mode 3). In all three instances, hydride-forming reagents were continuously delivered by means of the drain tube. The operability of all configurations was assessed for five hydride-forming elements (As, Se, Sb, Sn, Bi), while quantitative performance was ultimately established using the optimized in situ HG-hTISIS configuration operated at 200 °C. Non-hydride-forming elements including Li, Al, Mn, Ti, Co, V, Cr, Ni, Cu, Zn, Rb, Sr, Ag, Ba, Cd, Tl, and Pb were also determined under this configuration, with an efficient aerosol transport enabled by the thermal chamber. A Box-Behnken design was employed to optimize the concentrations of NaOH, NaBH4, and HCl, ensuring robust hydride formation and minimal matrix effects across a wide range of conditions. Analytical performance was evaluated in terms of sensitivity, precision, and limits of detection (LODs). Signal enhancement factors ranging from 13 to 150 were achieved for hydride-forming elements, with sub-μg L−1 detection limits and a sample uptake of only 30 μL min−1, in contrast to 0.5 mL min−1 in the conventional HG system. Moreover, foam formation was significantly mitigated in biological matrices, allowing direct analysis after sample dilution. Accuracy was confirmed through the analysis of certified reference materials of environmental and clinical origin, showing good agreement with the certified values. These results highlighted the analytical potential of the hydride generation HG-hTISIS configuration as a sensitive, low-consumption, and multielement-compatible alternative for the analysis of complex matrices by ICP-MS.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Analytical Validation of a Multielement ICP-MS Method for Human Serum and Its Application to Trace Element Biomonitoring in Hemodialysis Patients

  • Valderrama-Sanz, Sara
  • Sánchez, Raquel
  • Molina-Gasset, Ricardo
  • Todolí Torró, José Luis
  • Sánchez, Raquel|||/items/06c6cd36-b88e-43e0-929a-9b92d670da54
  • Todolí Torró, José Luis|||/items/e63cf980-21e8-48ec-8493-cdb380f1cccc
Reliable determination of trace elements in human serum is essential for clinical assessment, toxicological investigations and human biomonitoring. This study describes the development and analytical validation of a multielement inductively coupled plasma mass spectrometry (ICP–MS) method for the simultaneous determination of essential and potentially toxic trace elements in human serum (Ti, V, Cr, Mn, Co, Ni, Cu, Zn, As, Cd, Ba, Bi) using a simple direct-dilution procedure with 1% (v/v) nitric acid. Method validation included assessment of linearity, limits of detection and quantification, carry-over, precision, trueness, measurement uncertainty and analyte stability. Calibration curves showed excellent linearity, with coefficients of determination (R2) ranging from 0.9993 to 1.0000 across analyte-specific calibration ranges of 0–10, 0–50, and 0–500 µg L−1. Repeatability ranged from 0.69% (Cu) to 14.5% (Ba), while intermediate precision ranged from 1.32% (Zn) to 81.1% (Cd and Bi at low concentrations). Recoveries obtained using certified serum reference materials ranged from 55% (V) to 206% (Bi) across the evaluated conditions. Meanwhile, limits of detection ranged from 0.01 (V) to 0.16 (Cu) µg L−1. Measurement uncertainty was estimated following the EURACHEM/CITAC and GUM recommendations, identifying repeatability as the principal contributor to the overall uncertainty budget. The method was successfully applied to serum samples from healthy individuals and patients undergoing chronic hemodialysis. The proposed methodology combines simple sample preparation with comprehensive metrological characterisation, providing practical approach multielement serum analysis and its application to trace-element biomonitoring investigations.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Trace Element Imbalance and Redox-Relevant Serum Profile in Hemodialysis: A Validated Multielement ICP-MS Study

  • Valderrama-Sanz, Sara
  • Tortosa-Carreres, Jordi
  • Molina-Gasset, Ricardo
  • Todolí Torró, José Luis
  • Todolí Torró, José Luis|||/items/e63cf980-21e8-48ec-8493-cdb380f1cccc
Chronic kidney disease (CKD) is associated with persistent inflammation and increased oxidative stress. Trace elements play an important role in these processes as modulators of redox balance, acting either as cofactors of antioxidant systems or as potential inducers of pro-oxidant mechanisms. In this study, the serum profile of trace elements with antioxidant and pro-oxidant relevance was characterized by inductively coupled plasma mass spectrometry (ICP-MS) in hemodialysis patients. Results were compared with those from a healthy control group, and associations with biochemical and hematological parameters were explored. A cross-sectional observational study was conducted including 117 hemodialysis patients and 82 healthy controls, determining a panel of eight trace elements (Zn, Se, Cu, Mn, As, Cr, Co, and Ni). The method showed adequate sensitivity, satisfactory precision for most elements, and acceptable trueness. Hemodialysis patients exhibited significantly lower serum concentrations of Zn and Se, together with greater interindividual variability, as well as higher concentrations of elements with potential pro-oxidant effects, including As, Cr, Co, and Ni. Within this group, Zn and Se were mainly associated with markers of the protein compartment, Cu with ceruloplasmin and inflammatory markers, and Cr and Ni with parameters of renal function and vitamin D status.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Assessment of total sample consumption infrared-heated system for minimization of matrix effects in ICP-tandem mass spectrometry

  • Sánchez, Raquel
  • Todolí Torró, José Luis
  • Sánchez, Raquel|||/items/06c6cd36-b88e-43e0-929a-9b92d670da54
  • Todolí Torró, José Luis|||/items/e63cf980-21e8-48ec-8493-cdb380f1cccc
A total sample consumption infrared-heated system (IR-TSC) has been coupled to ICP-tandem mass spectrometry (ICP-MS/MS) for the first time. The objective of this study was to assess the analytical performance of the IR-TSC system, in terms of analytical figures of merit and mitigation of matrix effects. Twenty-seven elements have been determined: Ag, Al, As, B, Ba, Be, Bi, Cd, Co, Cr, Cu, Fe, K, Li, Mn, Mo, Ni, Pb, Rb, Sb, Se, Sn, Sr, Ti, Tl, V and Zn. Different operating conditions, including nebulization flow rate and spray chamber temperature, were optimized to improve sensitivity, signal stability, and plasma thermal conditions. The results showed that the infrared-heated sample introduction system improved the signal intensity by a factor of 2 to 4 compared to a conventional sample introduction system, whereas the limits of detection (LODs) improved by a factor going from 1.2 (Ba) to 3.3 (Cr) for a sample containing 2% HNO3. Meanwhile, for a 10% ethanol sample the improvement factor ranged from 1.4 (Ti) to 3.8 (Cr). Matrix effects for solutions containing inorganic acids or high content of sodium (2% HNO3, 10% HNO3, 20% HNO3, 10% HCl; 500 mg kg−1 Na, 500 mg kg−1 Na + 10% HNO3) were mitigated under optimum conditions (IR-TSC at 125 °C). Meanwhile, for solutions containing organic solvents (10% ethanol, 10% acetic acid, and 10% formic acid) it was not possible to eliminate matrix effects, even when applying an internal standard. For Se and As, elements spectrally interfered, the combination of IR-TSC sample introduction system with oxygen as reaction/collision gas mode in ICP-MS/MS provided accurate results. For 10% HNO3 and 10% HCl relative intensities values, calculated taking the signal intensity obtained for 2% HNO3 as reference, were close to the unity. Environmental and clinical control and certified reference materials were analyzed by means of an external calibration approach, with most of the elements showing concentrations not significantly different from the certified values. Finally, the IR-TSC was tested on twelve real samples, including seawater, surface water, peritoneal fluid, seminal plasma, wine, and bioethanol samples, demonstrating the system potential in different application fields.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Development of a Dispersive Liquid–Liquid Aerosol Phase Extraction Method for the Quantification of Ag, Cd, Cu, Ni, and Pb in Seawater by Inductively Coupled Plasma Optical Emission Spectroscopy

  • Guijarro-Ramírez, Nuria
  • Sánchez, Raquel
  • Todolí Torró, José Luis
  • Sánchez, Raquel|||/items/06c6cd36-b88e-43e0-929a-9b92d670da54
  • Todolí Torró, José Luis|||/items/e63cf980-21e8-48ec-8493-cdb380f1cccc
The dispersive liquid–liquid aerosol phase extraction (DLLAPE) method was applied for the determination of Ag, Cd, Cu, Ni, and Pb in seawater samples by inductively coupled plasma optical emission spectroscopy (ICP-OES). Key parameters such as sample pH and extractant concentration were systematically evaluated, with ammonium O,O′-diethyldithiophosphate (DDTP) identified as the optimal chelating agent. Optimal extraction conditions were achieved at pH 2.5 for Ag, Cu, Ni, and Pb, while Cd extraction efficiency was found to be pH independent. The extractant concentration did not greatly improve the extraction efficiency. Furthermore, the influence of nebulizer gas flow rate and extraction time was evaluated, achieving the maximum extraction yield at 0.6 L min–1 and 120 s, respectively. The method was evaluated for accuracy and bias through recovery studies, and the results showed that most elements had recovery rates close to 100% with relative standard deviation values in between 3 and 9%. However, in the case of Ag and Ni, 1.184 and 1.089 correction factors were, respectively, applied to compensate for the bias. Moreover, the procedural limits of quantification (pLOQs) found for Ag, Cd, Cu, Ni, and Pb were 0.4, 0.14, 0.2, 0.2, and 0.2 μg L–1, respectively. The in-house validation of the method provided expanded uncertainty values lower than 6% for all elements except for Ag (16.6%). Finally, the application of the method to real seawater samples from coastal areas in Alicante and San Juan (Spain) confirmed its suitability for trace metal analysis in complex marine matrices, underscoring its potential for environmental monitoring and research.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Application of Dispersive Liquid–Liquid Aerosol Phase Extraction to the Analysis of Total and Individual Phenolic Compounds in Fried Extra Virgin Olive Oils

  • Sánchez, Raquel
  • Beltrán Sanahuja, Ana
  • Prats Moya, Soledad
  • Todolí Torró, José Luis
  • Beltrán Sanahuja, Ana|||/items/e050de26-d5fa-4bc8-8092-760c0d8865d0
  • Prats Moya, Soledad|||/items/d05382ec-4153-4251-8997-1cbb0038ac36
  • Sánchez, Raquel|||/items/06c6cd36-b88e-43e0-929a-9b92d670da54
  • Todolí Torró, José Luis|||/items/e63cf980-21e8-48ec-8493-cdb380f1cccc
Seventeen extra virgin olive oil samples from Valencian Community (Spain) were submitted to a domestic-frying process (180 °C) during different degradation times (5, 10, 30, 60, 120 min). A dispersive liquid–liquid aerosol phase extraction by using a methanol/water (50:50) extracting solution was used to isolate the polyphenol fraction. Total phenolic content (TPC) was determined, whereas the determination of seven individual target polyphenolic compounds (hydroxytyrosol, tyrosol, oleuropein, vanillic acid, p-coumaric acid, ferulic acid, and vanillin) was carried out by using ultrahigh-performance liquid chromatography coupled to a tandem mass spectrometer. Statistically significant differences in the TPC values were found for Blanqueta and Manzanilla samples from different harvesting years. The domestic-frying process impacted the TPC and the individual phenolic compounds content. Thermal treatment for 2 h gave rise to a 94% decrease in the TPC. A first-order kinetic model was suitable to accurately describe the degradation of the individual phenolic compounds.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Cutting-edge arsenic quantification in pyrolysis oils: evaluation of a high temperature torch integrated sample introduction system (hTISIS) combined with an ICP-MS/MS

  • Todolí-Carbonell, Mar
  • Pérez Ramírez, Rebeca
  • Coquet, Thomas
  • Chainet, Fabien
  • Lacoue-Nègre, Marion
  • Sánchez, Raquel
  • Sánchez, Raquel|||/items/06c6cd36-b88e-43e0-929a-9b92d670da54
  • Todolí-Carbonell, Mar|||/items/9a91ef35-dd33-45c7-bc3e-33decfd127ec
An innovative approach for routine arsenic quantification in complex tire pyrolysis oil (TPO) matrices by combining a high temperature torch integrated sample introduction system (hTISIS) with ICP-MS/MS is presented. Tire pyrolysis oils present significant potential as alternative fuels but require precise monitoring of arsenic due to its environmental toxicity and its detrimental effects on catalytic processes. The hTISIS system, operating at 400 °C, significantly enhanced analyte transport efficiency, increasing the signal by up to 20-fold compared to conventional sample introduction systems. Moreover, the method achieved detection limits as low as 2 ng kg−1 for arsenic in xylene, significantly lower than the 20 ng kg−1 obtained using conventional sample introduction systems. Moreover, procedural limit of quantification (pLOQ) obtained for the hTISIS system was 60 ng kg−1. Additionally, the combination of hTISIS working at 400 °C and ICP-MS/MS successfully mitigated matrix effects and spectral interferences by employing oxygen as a reaction gas, allowing accurate quantification even in samples containing high chlorine levels. Analysis of 13 TPO samples showed arsenic concentrations ranging from 41 ± 4 to 924 ± 80 µg kg−1. The results were validated through comparison with microwave digestion method, showing no statistically significant differences for most samples with a confidence level of 95%.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Development and Validation of an ICP-MS/MS Method for the Multielemental Analysis of Cerebrospinal Fluid, Examination of Alzheimer's Disease Samples

  • Pérez Ramírez, Rebeca
  • Cuchillo-Ibáñez, Inmaculada
  • Sánchez, Raquel
  • Beltrán Sanahuja, Ana
  • Escamilla, Sergio
  • Molina-Gasset, Ricardo
  • Zetterberg, Henrik
  • Blennow, Kaj
  • Sáez-Valero, Javier
  • Todolí Torró, José Luis
  • Sánchez, Raquel|||/items/06c6cd36-b88e-43e0-929a-9b92d670da54
  • Beltrán Sanahuja, Ana|||/items/e050de26-d5fa-4bc8-8092-760c0d8865d0
  • Todolí Torró, José Luis|||/items/e63cf980-21e8-48ec-8493-cdb380f1cccc
Multielemental analysis of cerebrospinal fluid (CSF) yields critical insights into the pathophysiology of neurological disorders and holds potential as a diagnostic and predictive tool for Alzheimer's disease (AD). The present work presents the development and validation of an inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) based method for multielemental determination in CSF, including metals and metalloids as analytes. As a proof of concept, the importance of the CSF element determination was evaluated in a cohort of patients with AD (n = 20) and non-AD controls (n = 19) who displayed typical levels of core CSF biomarkers (Aβ42, P-tau, and total-tau). Discrete sample introduction ICP-MS/MS procedure was effective for accurate and precise CSF analysis. The methodology provided better sensitivities and limits of detection than a conventional one based on sample dilution and analysis in continuous sample introduction mode, while only requiring a 20 μL CSF sample volume. A total of 24 elements were encountered and quantified in CSF, with reduced levels of Mn, Cr, Se, Fe, and Zn in the CSF from AD patients and increased levels of Ag and Bi, compared with non-AD patients. Particularly, Mn fully discriminated AD from non-AD subjects, with binary regression analysis indicating that Mn was the most effective element to distinguish between AD and non-AD groups. Furthermore, distinctive correlation profiles were found between AD and non-AD controls for elements with AD core biomarkers and the alternative amyloidogenic sAPPβ fragment. Quantitative determination of metals, metalloids and non-metals displays differences associated with pathological status, serving as additional biomarkers for neurological diseases.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Multielemental characterization of mussels (Mytilus galloprovincialis): Geographic variability, tissue distribution and cooking-induced changes

  • Pérez Ramírez, Rebeca
  • Sánchez, Raquel
  • Maestre, Salvador E.
  • Beltrán Sanahuja, Ana
  • Todolí Torró, José Luis
  • Sánchez, Raquel|||/items/06c6cd36-b88e-43e0-929a-9b92d670da54
  • Maestre, Salvador E.|||/items/b30727cb-70d3-48d8-a950-f7612e9e53a8
  • Beltrán Sanahuja, Ana|||/items/e050de26-d5fa-4bc8-8092-760c0d8865d0
  • Todolí Torró, José Luis|||/items/e63cf980-21e8-48ec-8493-cdb380f1cccc
In this study, the multielemental composition of 33 groups of Mytilus galloprovincialis collected from different Galician coastal areas was investigated by ICP-MS/MS. Particular attention was paid to geographical variability, tissue-specific accumulation patterns, and the influence of steam cooking on elemental concentrations. The analytical procedure showed satisfactory performance, with recoveries between 87% and 119% for most certified elements and limits of quantification suitable for routine seafood monitoring. Multivariate statistical analyses revealed substantial variability among sampling groups and enabled the classification of mussels according to their elemental fingerprints, highlighting the influence of environmental and biological factors on elemental accumulation. Distinct tissue-specific distribution patterns were observed, with several elements, including Cu, Ni, Co, Cr and As, tending to accumulate preferentially in the digestive gland (DG), whereas Zn showed higher concentrations in the mantle. Steaming produced element-dependent effects on elemental composition. Significant changes were observed for Fe, Rb and Cd, while consistent decreases were detected for As, Se and Rb across all analysed batches. Arsenic concentrations decreased in every sample following steaming, and the detection of arsenic and other elements in the cooking broth indicated that elemental migration to the cooking medium contributes to the observed behaviour.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Valorization of Pineapple Core Waste for Sequential Extraction of Phenolic Compounds and Carotenoids: Optimization Through Ultrasound-Assisted Method and Box–Behnken Design

  • Beltrán Sanahuja, Ana
  • Valdés, Arantzazu
  • Baenas, Nieves
  • Ferrando, Belén Olga
  • Periago, María Jesús
  • Cenitagoya Alonso, Natalia
  • Sánchez, Raquel
  • Todolí Torró, José Luis
  • Beltrán Sanahuja, Ana|||/items/e050de26-d5fa-4bc8-8092-760c0d8865d0
  • Sánchez, Raquel|||/items/06c6cd36-b88e-43e0-929a-9b92d670da54
  • Todolí Torró, José Luis|||/items/e63cf980-21e8-48ec-8493-cdb380f1cccc
  • Valdés, Arantzazu|||/items/4014bcef-f512-4723-8000-650f5d9ad7e9
  • Baenas, Nieves|||/items/0d564d73-79c5-4248-ab2d-212b951d6df3
In this study, a pioneering cascade method involving ultrasound-assisted extraction (UAE) and Box–Behnken Design (BBD) was optimized to valorize pineapple core waste by the sequential extraction of, firstly phenolic compounds and, secondly, carotenoids. The effectiveness of the extraction was evaluated based on total polyphenol content (TPC) and antioxidant activity using 2,2′-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS) and ferric reducing antioxidant power (FRAP) assays. Characterization of the carotenoids was performed using high-performance liquid chromatography with a diode array detector (HPLC–DAD). The initial characterization of dry pineapple core (DPC) samples revealed their nutritional composition, including protein, lipid, and carbohydrate weight percentages of 1.20 ± 0.05%, 5.3 ± 0.4%, and 88.6 ± 0.5%, respectively. The high extractives content (40.0 ± 4.5%) suggests a substantial presence of phenolic compounds, making the pineapple core a valuable source of natural antioxidants. The optimal UAE conditions for phenolic compound extraction were 70% amplitude, 5 min extraction time, and 2 cycles, yielding an antioxidant extract rich in phenolic compounds with a desirability value of 81.2%. Therefore, DPC was considered a valuable source of natural antioxidants. The extraction of β-carotene also showed promising results with optimal UAE conditions of 20% amplitude, 3 min extraction time, and 2 cycles. This research promotes the sustainable use of pineapple waste and demonstrates the potential to obtain valuable additives for the food, pharmaceutical, and cosmetic industries, encouraging a more circular and efficient use of resources in the pineapple processing industry.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Breaking barriers in thermal interface materials: Ultrahigh thermal conductivity and electrical insulation in epoxy/diamond composites via multimodal packing and dual-mode interface engineering

  • Molina Jordá, José Miguel
  • Molina Jordá, José Miguel|||/items/04e52741-4cf2-482e-a208-79f3a27350e7
Achieving high thermal conductivity together with electrical insulation remains a central challenge in the development of thermal interface materials for advanced electronics. Bulk diamond meets both requirements but is constrained by cost and processability, steering efforts toward electrical insulating diamond-filled polymer composites, most of which deliver thermal conductivities < 3 W·m⁻1·K⁻1, while only a few exceeded 12  W·m⁻1·K⁻1. Here we demonstrate infiltrated epoxy/diamond composites that combine trimodal diamond packing with roughened, sp2-carbon interfaces, enabling ultrahigh thermal conductivities up to 40  W·m⁻1·K⁻1 while preserving electrical resistivities > 3.5 × 101⁰ Ω·m. Trimodal packing raises filler loading (up to a volume fraction of 0.85), full epoxy infiltration suppresses electrical percolation, and roughened, in-situ graphitized interphases reduce thermal boundary resistance. This > 300% improvement over the state-of-the-art diamond-containing polymer composites outlines a scalable, cost-effective route to thermally conductive, electrically insulating materials. These materials are highly promising for applications in microelectronics, power electronics, and next-generation high-density devices.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Evaluation of highly adsorptive Guefoams (multifunctional guest-containing foams) as a potential sorbent for determination of volatile organic compounds (VOCs) by means of thermal desorption

  • Sánchez, Raquel
  • Beltrán Sanahuja, Ana
  • Maiorano Lauría, Lucila Paola
  • Todolí Torró, José Luis
  • Molina Jordá, José Miguel
  • Beltrán Sanahuja, Ana|||/items/e050de26-d5fa-4bc8-8092-760c0d8865d0
  • Maiorano Lauría, Lucila Paola|||/items/f667840c-2310-43e7-bfb3-3c98cd06e781
  • Molina Jordá, José Miguel|||/items/04e52741-4cf2-482e-a208-79f3a27350e7
  • Sánchez, Raquel|||/items/06c6cd36-b88e-43e0-929a-9b92d670da54
  • Todolí Torró, José Luis|||/items/e63cf980-21e8-48ec-8493-cdb380f1cccc
The present work delves into the feasibility of employing a novel structured sorbent referred to as GFAD (Guefoam Adsorption Device) for the determination of volatile organic compounds (VOCs) in liquid samples. The chosen method has been static headspace sorptive extraction-thermal desorption gas chromatography mass spectrometry (HSSE-TD-GC–MS). The GFAD comprises an aluminum cellular material with a distinct replication structure and a solid guest phase consisting of activated carbon particles dispersed within the cavities of the cellular aluminum. The extensive specific surface area, robustness, and exceptional thermal conductivity of this pioneering material offer distinct advantages over commercially available polydimethylsiloxane-based Twister® devices. Therefore, the trapping efficiency for volatile organic compounds is enhanced, and it is possible to perform the analysis of concentrated samples. According to computational simulations, it has been demonstrated that GFAD has a high heat conductivity. As a result, the desorption efficiency is improved, and minimal temperature gradients are generated throughout the GFAD during the heating process. Besides, the energy consumption is significantly lowered, thus aligning with environmentally conscientious and sustainable analytical practices. The experimental results give a proof of the suitability of the GFAD for determining gaseous compounds in liquid samples through HSSE-TD-GC–MS. For volatile species, the new material provides higher peak areas and lower limits of detection than a commercially available Twister® device. Furthermore, the GFAD is reusable, its adsorbing properties remaining unchanged during, at least, 100 consecutive analyses. In addition, unlike to the Twister®, no intense siloxane peaks are observed in the chromatograms obtained with the GFAD. The feasibility of qualitative and semi-quantitative analysis with the new accessory has been demonstrated with both standards and a cereal bioethanol real sample.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Longitudinal trace element monitoring in haemodialysis patients: Impact of dialysis vintage and technical treatment factors

  • Valderrama-Sanz, Sara
  • Tortosa-Carreres, Jordi
  • Rosell-Saiz, Nuria
  • Molina-Gasset, Ricardo
  • Todolí Torró, José Luis|||/items/e63cf980-21e8-48ec-8493-cdb380f1cccc
Background Chronic kidney disease and haemodialysis (HD) profoundly alter essential element homeostasis, causing both deficiencies and toxic metals accumulation. This research aimed to characterise serum trace element status in HD patients compared to healthy controls (CNTRL) and to investigate the time-dependent accumulation and modulation of these elements by clinical and dialysis-related technical factors. Materials and methods A prospective cross-sectional (HD vs. CNTRL) and two-year longitudinal (HD cohort) study was conducted at a single centre (Alcoy, Spain, 2015–2017). A total of 199 participants (117 HD, 82 CNTRL), matched for age and sex, were included. Serum trace elements were quantified using highly sensitive inductively coupled plasma-mass spectrometry (ICP-MS) after rigorous validation. Cross-sectional differences were analysed using multivariable linear and Tobit regression adjusted for clinical confounders and dialysis-specific variables. Longitudinal changes were assessed using linear mixed-effects models (LMM). Results HD patients had significantly lower zinc, selenium, and rubidium levels (p < 0.0001) and higher chromium, arsenic, nickel, cobalt, molybdenum, and titanium levels (all p ≤ 0.03). Dialysis vintage ≥12 months was associated with higher accumulation of chromium, nickel, vanadium, and titanium, highlighting a progressive, time-dependent risk. Water calcium ≥1.5 mmol/L correlated with lower levels of nickel and chromium (p ≤ 0.03). The LMM confirmed increasing nickel (p = 0.0006) and decreasing selenium (p = 0.006) over time. Conclusion HD patients suffer profound, progressive dyshomeostasis of trace elements, marked by deficiencies in essential elements and accumulation of toxic metals. These findings underscore the need for systematic monitoring and targeted interventions to optimise essential element status and reduce toxic metal burden.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Green Ultrasound-Assisted Extraction of Onion Polyphenols Using a Choline Chloride-Urea Deep Eutectic Solvent: Extraction Efficiency, Solvent Selectivity, and Antioxidant Assay Compatibility

  • Jankulovska, Mirjana S.
  • Sánchez, Raquel|||/items/06c6cd36-b88e-43e0-929a-9b92d670da54
  • Guillena, Gabriela
  • Guillena, Gabriela|||/items/cc60bdaf-2c2d-4a78-9538-389c99026973
  • Todolí Torró, José Luis|||/items/e63cf980-21e8-48ec-8493-cdb380f1cccc
Deep eutectic solvents (DES) emerge as sustainable alternatives for antioxidant polyphenol extraction; however, their analytical performance and compatibility with antioxidant assays remain insufficiently characterized. A choline chloride-urea-water DES (1:2:4) was compared with 70% ethanol for extracting polyphenols from onion bulbs and peels from cultivars grown in Spain and North Macedonia. Extraction conditions were selected through a comparative evaluation of vortex- and ultrasound-assisted extraction and benchmarked against conventional ethanolic stirring (2 h). Two-way ANOVA identified solvent composition as the main determinant of total phenolic content (F(1,20) = 1526.28, p < 0.001), while extraction method significantly influenced recovery under DES conditions (F(2,30) = 408.52, p < 0.001). The selected UAE-DES protocol increased TPC up to 2.2-fold and reduced extraction time to <5 min. TPC ranged from 25 to 44 mg GAE/g dw in bulbs and 42–62 mg GAE/g dw in peels, with red cultivars showing the highest values. UHPLC-MS/MS revealed solvent-dependent selectivity: ethanol favored flavonols (quercetin 5–11 mg/g dw), whereas DES enhanced phenolic acids (gallic acid up to 0.3 mg/g dw; protocatechuic acid up to 7 mg/g dw). FRAP correlated with TPC (r = 0.64–0.92), while ABTS was incompatible with DES extracts. Storage reduced TPC by 45–75% but preserved cultivar ranking. These findings demonstrate that UAE-DES enables rapid and efficient polyphenol recovery while highlighting the need to validate antioxidant assays in non-conventional solvents.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Development and Validation of an ICP-MS/MS Method for Multi-elemental Analysis of Human Hair with Application to Heart Failure

  • Ramírez-Castillo, Pablo
  • García-Suarez, Alba
  • Morillas Blasco, Pedro
  • Vicente Ibarra, Nuria
  • García Honrubia, Antonio
  • Martínez Moreno, Marina
  • Sánchez, Raquel
  • Beltrán Sanahuja, Ana
  • Todolí Torró, José Luis
  • Ramírez-Castillo, Pablo|||/items/6f3114cc-083d-4d5f-a9b7-7c9de54b862a
  • Sánchez, Raquel|||/items/06c6cd36-b88e-43e0-929a-9b92d670da54
  • Beltrán Sanahuja, Ana|||/items/e050de26-d5fa-4bc8-8092-760c0d8865d0
  • Todolí Torró, José Luis|||/items/e63cf980-21e8-48ec-8493-cdb380f1cccc
Human hair has emerged as a promising non-invasive matrix for assessing long-term exposure to essential and toxic trace elements relevant to cardiovascular disease. However, its clinical applicability depends on the availability of robust and fully validated analytical methodologies capable of overcoming matrix-related challenges. This study aimed to develop and validate a reliable and high-throughput method for multi-elemental (As, Cd, Cu, Pb, Se and Zn) analysis of human hair using microwave-assisted acid digestion followed by ICP-MS/MS, and to explore its potential application in a pilot cohort of heart failure (HF) patients. Method validation was performed using the certified reference material ERM-DB001. Analytical performance was evaluated in both no-gas and He-KED modes, assessing precision, trueness, procedural detection limits, and measurement uncertainty according to EURACHEM/CITAC guidelines. The influence of sample mass (20–200 mg) was also investigated. The validated method was subsequently applied to hair samples from 25 HF patients and 25 control subjects. The method demonstrated satisfactory intra- and inter-day precision, particularly for Cd, Cu, Se, and Zn. He-KED mode effectively reduced polyatomic interferences, improving selectivity and lowering detection limits for elements such as As and Se. Optimal analytical performance was achieved for sample masses between 60 and 100 mg, while lower masses resulted in increased uncertainty. In the pilot application, exploratory differences were observed for Pb, Mg, Ca and Zn concentrations, together with changes in selected elemental correlations (Mg/Na, Pb/Mn, Sr/Ni, Fe/Al, Fe/Ti and Mn/Ti) between heart failure patients and controls. The validated ICP-MS/MS method provides a sensitive and reliable approach for multi-elemental analysis of human hair. Its robustness and applicability to real samples support its potential use in clinical and epidemiological studies, although further research with larger cohorts is required to confirm the observed trends.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Deep eutectic solvent-based rapid extraction for multielement analysis of onion pulp and peel by ICP-MS/MS: a green alternative to microwave digestion

  • Sánchez, Raquel
  • Jankulovska, Mirjana S.
  • González-Linares, Alejandro
  • Guillena, Gabriela
  • Todolí Torró, José Luis
  • Sánchez, Raquel|||/items/06c6cd36-b88e-43e0-929a-9b92d670da54
  • Guillena, Gabriela|||/items/cc60bdaf-2c2d-4a78-9538-389c99026973
  • Todolí Torró, José Luis|||/items/e63cf980-21e8-48ec-8493-cdb380f1cccc
The development of greener and faster sample preparation strategies is essential to reduce the environmental and time costs associated with conventional digestion-based protocols for multielement analysis. In this work, a hydrophilic deep eutectic solvent (DES) based on choline chloride, urea and water (ChCl:U:H2O = 1:2:4) was evaluated as an alternative extraction medium for the determination of metals and metalloids in onion tissues by ICP-MS/MS. Onion pulp and peel were selected as a model heterogeneous food matrix. Extraction conditions were systematically optimised with respect to solid-to-solvent ratio, extraction technique and extraction time. A 1:10 (w w−1) ratio combined with short extraction times provided an effective compromise between extraction efficiency and analyte enrichment. Under these optimised conditions, vortex-assisted extraction (3 min) and ultrasound-assisted extraction in a bath (5 min) afforded quantitative recoveries for the target elements and procedural limits of quantification lower than those obtained after microwave-assisted acid digestion, mainly due to the reduced overall dilution. Method accuracy was assessed by benchmarking the DES-based procedures against microwave digestion used as a reference; for most elements and both tissues, no statistically significant differences were observed. The greenness of the evaluated strategies was quantified using the AGREEprep metric, revealing a clear improvement when replacing acid digestion with DES-based extraction, with the vortex-assisted and ultra-sound protocols providing the highest score (0.65 and 0.64, respectively). Application to white and red onions from different geographical origins demonstrated the suitability of the method for resolving tissue and origin-dependent elemental distributions, establishing DES-based vortex extraction as a fast, reliable and greener alternative to conventional digestion for multielement analysis of plant-derived food matrices.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Energy-efficient cooling of electronics using non-stochastic aluminum/diamond composite foams with engineered interfaces

  • Maiorano Lauría, Lucila Paola
  • Molina Jordá, José Miguel
  • Maiorano Lauría, Lucila Paola|||/items/f667840c-2310-43e7-bfb3-3c98cd06e781
  • Molina Jordá, José Miguel|||/items/04e52741-4cf2-482e-a208-79f3a27350e7
The progressive miniaturization and rising power densities of electronic devices have intensified the need for materials enabling energy-efficient thermal management. This study introduces high-porosity, non-stochastic aluminum/diamond composite foams with engineered interfaces to enhance heat dissipation. . Ceramic molds were first prepared by inverse replication of additively manufactured Kelvin-cell PLA templates, producing high-porosity structures with controlled geometry and interconnectivity. Molten aluminum was then infiltrated under pressure into these molds densely packed with diamond particles, forming aluminum/diamond composite foams. Controlled in situ formation of Al4C3 interfacial phases significantly boosted thermal transport, yielding thermal conductivities up to three times higher than pure aluminum Kelvin foams, while maintaining low pressure drops. Compared to commercial aluminum and copper Duocel® foams of equivalent porosity, the composite foams achieved 240% and 120% higher conductivities, respectively, with superior balance between thermal performance and flow resistance. Power dissipation tests showed up to near 50% improvement over pure aluminum foams. The heat dissipation behavior in a representative electronic cooling scenario was evaluated through CFD simulations incorporating the experimentally measured thermal properties of the composite foams, resulting in reduced hotspot temperatures compared to pure aluminum foams. Analytical and numerical validation confirmed that interfacial engineering and non-stochastic design effectively improve heat transfer and energy efficiency. The results position the developed architected Al/diamond composite foams as promising candidates for next-generation electronic cooling materials.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Enhanced direct analysis of organic samples using a high temperature total consumption sample introduction system coupled to microwave plasma optical emission spectrometry (MIP-OES)

  • Martínez, Santiago
  • Marsault, Anne-Sophie
  • Lefevre, Johan
  • Sánchez, Raquel
  • Todolí Torró, José Luis
  • Sánchez, Raquel|||/items/06c6cd36-b88e-43e0-929a-9b92d670da54
  • Todolí Torró, José Luis|||/items/e63cf980-21e8-48ec-8493-cdb380f1cccc
This work presents the coupling of a high temperature Torch Integrated Sample Introduction System (hTISIS) to microwave plasma optical emission spectrometry (MIP-OES) for multielemental analysis of organic samples, specifically biofuels and oils. An innovative method for automated, routine analysis of organic samples by MIP-OES, using continuous sample delivery to the spectrometer has been developed. The hTISIS, operated at 300 °C, significantly improved analyte transport efficiency and mitigated matrix effects. Limits of quantification (LOQs) achieved at a 40 μL min−1 liquid flow rate were markedly reduced compared to conventional sample introduction system at 250 μL min−1. Values ranged from 2 μg kg−1 for Cu to 100 μg kg−1 for Pb and 200 μg kg−1 for Zn, compared to 70 μg kg −1, 700 μg kg−1 and 30 μg kg−1 obtained with the conventional device, respectively. Recovery tests across six oil and fat samples validated the method accuracy, with recovery rates between 90 and 110 % achieved without the use of an internal standard, demonstrating effective matrix effect mitigation at 300 °C. Under these conditions, Ca, Cr, Cu, Fe, K, Mg, Mn, Na, Pb, Si and Zn concentrations were determined in six oil and fat samples. The analysis of samples was done after dilution (1:20) using xylene as the diluent to ensure proper sample introduction. The concentration values were compared with those found by applying the reference method UOP 389-15 and statistically equivalent values were found, establishing the robustness and precision of the hTISIS-MIP-OES for direct elemental profiling of organic matrices.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Combination of a high-temperature torch-integrated sample introduction system with the single injection calibration approach for arsenic speciation by HPLC-ICP-MS/MS

  • Pérez Ramírez, Rebeca
  • Sánchez, Raquel
  • Prats Moya, Soledad
  • Beltrán Sanahuja, Ana
  • Todolí Torró, José Luis
  • Sánchez, Raquel|||/items/06c6cd36-b88e-43e0-929a-9b92d670da54
  • Prats Moya, Soledad|||/items/d05382ec-4153-4251-8997-1cbb0038ac36
  • Beltrán Sanahuja, Ana|||/items/e050de26-d5fa-4bc8-8092-760c0d8865d0
  • Todolí Torró, José Luis|||/items/e63cf980-21e8-48ec-8493-cdb380f1cccc
This study presents a comparative evaluation of the high-temperature torch-integrated sample introduction system (hTISIS) and a conventional Scott double-pass spray chamber for arsenic speciation analysis by high-performance liquid chromatography coupled with inductively coupled plasma tandem mass spectrometry (HPLC-ICP-MS/MS). Despite operating at low sample flow rates (c.a., 45 μL min−1) compared to the conventional system (0.5 mL min−1), the hTISIS set at 150 °C significantly enhanced sensitivity and led to five times lower limits of detection (LOD) and quantification (LOQ). Additionally, the single injection calibration approach (SICA) was implemented as an alternative quantification strategy. Unlike conventional multi-point calibration, the SICA constructs a calibration curve from the injection of a single standard, significantly shortening the calibration time by a factor of four and minimizing reagent and mobile phase consumption as well as the residue generation. The method was validated using two certified reference materials (Frozen Human Urine SRM 2669 and Apple Juice SRM 3035), achieving excellent accuracy with recoveries ranging from 92 to 110 %, and good precision (RSD <10 %). Chromatographic separation was performed using a PRP-X 100 anion-exchange column (5 μm, 150 × 2.1 mm) under gradient elution with 60 mmol L−1 ammonium bicarbonate (pH 8.7) and 5 % methanol, enabling baseline separation of arsenite (As(III)), arsenate (As(V)), dimethylarsinic acid (DMAA), methylarsonic acid (MMAA), and arsenobetaine (AsB) within 12 min. The hTISIS-HPLC-ICP-MS/MS assembly was successfully applied to the determination of arsenic species in commercial juice samples, demonstrating its suitability for food safety monitoring. While inorganic arsenic was found in the tested samples at concentrations (in μg kg−1) ranging from 10.4 ± 0.2 to 31 ± 2, DMAA and MMAA were only found at the 2–3 μg kg−1 level in two samples (mixed fruit and apple juice, respectively). Meanwhile, the conventional sample introduction system was not able to provide LOQs low enough to perform this kind of determinations.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Low-porosity aluminum foams with steel guest phases as disruptive materials for active thermal management

  • Maiorano Lauría, Lucila Paola
  • Guidoum, Maroua
  • Molina Jordá, José Miguel
  • Maiorano Lauría, Lucila Paola|||/items/f667840c-2310-43e7-bfb3-3c98cd06e781
  • Molina Jordá, José Miguel|||/items/04e52741-4cf2-482e-a208-79f3a27350e7
Low-porosity metal foams, emerging as promising materials for efficient heat dissipation, outperform their high-porosity counterparts in conductive-convective performance. However, their current thermal capabilities fall short for cutting-edge electronics. This study introduces newly designed Guefoams, a novel family of low-porosity foam materials, and explores their suitability for heat dissipation. The Guefoams prepared herein feature a unique structure with guest phases (steel spheres) seamlessly integrated into the porous cavities of aluminum foams, devoid of bonds with the foam matrix. The study emphasizes the impact of design parameters (dimensions of interconnecting windows and guest phases) on thermo-fluid dynamic properties. The empirical evidence, supported by computational simulation results, demonstrates that these guest phases significantly enhance heat transfer by up to 60 % compared to analog low-porosity aluminum foams. This enhancement primarily arises from two factors: i) altering fluid dynamics via guest phase impedance, influencing flow patterns, and ii) amplifying surface area for greater solid-fluid heat transfer. Compared to high-porosity aluminum foams, a current standard in heat dissipation, the developed materials exhibit heat transfer coefficients >600 % higher. Overall, these advancements position the developed Guefoams as a promising solution for demands in challenging active heat dissipation.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Multielemental analysis of oils and animal fat by using deep eutectic solvents assisted by an aerosol phase extraction procedure

  • Torres, Ana
  • Romero, Ismael
  • Sánchez, Raquel
  • Beltrán Sanahuja, Ana
  • Guillena, Gabriela
  • Todolí Torró, José Luis
  • Beltrán Sanahuja, Ana|||/items/e050de26-d5fa-4bc8-8092-760c0d8865d0
  • Guillena, Gabriela|||/items/cc60bdaf-2c2d-4a78-9538-389c99026973
  • Sánchez, Raquel|||/items/06c6cd36-b88e-43e0-929a-9b92d670da54
  • Todolí Torró, José Luis|||/items/e63cf980-21e8-48ec-8493-cdb380f1cccc
In the present study, thirteen elements (Ag, Al, Ba, Cd, Cr, Cu, Fe, K, Li, Mg, Mn, Ni, Pb) have been extracted from used cooking oils, olive oils and animal fat. Either inductively coupled plasma optical emission spectrometry (ICP-OES) or tandem mass spectrometry (ICP-MS/MS) have been chosen as detection techniques. Due to the difficulty of directly introducing highly viscous organic samples into the spectrometer, a fast dispersive liquid – liquid aerosol phase extraction (DLLAPE) method has been selected to isolate the analytes from the sample matrix. The DLLAPE is based on the generation of an aerosol from the extracting phase with the help of a pneumatic nebulizer. This high velocity aerosol impacts and penetrates in the liquid sample. Consequently, the liquid – liquid exchange surface area becomes high, thus leading to high extraction yields. A hydrophilic deep eutectic solvent (DES) consisting of choline chloride and ethylene glycol (1:2 mass ratio) has been selected as the extracting solvent. Prior to undertaking the experiments, the extraction method has been evaluated in terms of precision under suitable conditions. In comparison with conventional methods based on sample digestion, sample dilution and shot analysis or extraction assisted by vortex agitation, the DLLAPE shows several advantages, because it is faster, and it provides lower limits of detection than the reference methodologies. The procedural limits of quantification for the determined elements with the DLLAPE in ICP-OES were 0.046 (Ag), 0.396 (Al), 0.013 (Cd), 0.033 (Cr), 0.040 (Cu), 0.20 (Fe), 0.026 (K), 0.026 (Li), 0.33 (Mg), 0.013 (Mn), 2.64 (Ni) and 0.53 (Pb) mg kg−1. Meanwhile, pLOQ in ICP-MS/MS lowered by roughly one order of magnitude. The accuracy of the aerosol phase extraction method has been evaluated through the determination of the recoveries for four representative analytes (Ca, Cu, Mg and Ni) from spiked real samples. For these elements, recovery has taken values of (100 ± 20)%. Moreover, a comparison of the multielemental concentration obtained with conventional methods (c.a., sample dilution and shot ICP analysis and liquid-liquid extraction using a vortex agitator) against that measured with the DLLAPE has been carried out. Multiemelemental concentrations have been obtained for real samples and the found levels have been similar to those encountered in previously published works.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Dispersive liquid-liquid aerosol phase extraction for the determination of acetylated bromophenols in urine by gas chromatography – mass spectrometry

  • Sánchez, Raquel|||/items/06c6cd36-b88e-43e0-929a-9b92d670da54
  • Peña, Javier
  • Todolí Torró, José Luis|||/items/e63cf980-21e8-48ec-8493-cdb380f1cccc
  • González-Mariño, Iria
Background. Bromophenols are urinary biomarkers of human exposure to brominated flame retardants, but their determination remains challenging because they occur at ultra-trace levels in this complex biological matrix. Results Under optimized conditions, the acetylating reagent (acetic anhydride) and the extracting solvent (heptane) are nebulized directly into the buffered urine sample, generating an interfacial surface area that accelerates mass transfer. The extraction is completed in 80 s and yields a ready-to-inject organic extract through spontaneous phase separation, avoiding the time-consuming centrifugation steps typically required in conventional liquid-liquid extraction. The method demonstrated satisfactory trueness (recoveries of 74–130 %), good overall precision with RSD values generally ≤20 %, and limits of quantification ranging from 70 to 370 pg mL-1 in human urine. Finally, it was successfully applied to urine samples from five healthy adult volunteers with no known exposure to brominated flame retardants, allowing the quantification of several mono-, di-, and tri-bromophenols at sub-ng mL-1 levels. Significance The study represents the first application of DLLAPE to the extraction of organic compounds from aqueous matrices, specifically from urine. It provides a rapid, solvent-minimized, and high-throughput alternative to conventional liquid-liquid extraction for the determination of bromophenols in urine.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Unexpected high levels of iron and rubidium in the peritoneal fluid of endometriosis patients

  • López-Botella, Andrea
  • Romero, Alejandro
  • Sánchez, Raquel
  • Todolí Torró, José Luis
  • Velasco-Ruiz, Irene
  • Acién, Maribel
  • Gómez-Torres, María José
  • López-Botella, Andrea|||/items/b997136f-08a8-46c7-8e40-df117c325947
  • Romero, Alejandro|||/items/b302b8a7-45cd-4efd-a466-8fc7aab2e97b
  • Sánchez, Raquel|||/items/06c6cd36-b88e-43e0-929a-9b92d670da54
  • Todolí Torró, José Luis|||/items/e63cf980-21e8-48ec-8493-cdb380f1cccc
  • Velasco-Ruiz, Irene|||/items/28a40dfc-74e2-4b42-8542-f07903a23f8a
  • Gómez-Torres, María José|||/items/98e76526-8bb1-4710-9b76-59f6fadc332c
Background: Endometriosis disease affects up to 10 % of menstruating people worldwide and can lead to infertility. Environmental pollutants are risk factors influencing the probability of developing endometriosis. Objective: We aimed to explore the differences in the content of potentially toxic elements (PTEs), trace, and ultra-trace elements in the peritoneal fluid (PF) of endometriosis subjects compared to control subjects. Methods: A hospital-based case–control study was conducted between 2020 and September 2022 at the Obstetrics and Gynecology Service of San Juan University Hospital (Alicante, Spain), where PF samples were collected from 61 patients, including both endometriosis cases and controls. The concentration of barium (Ba), bismuth (Bi), cadmium (Cd), cobalt (Co), lithium (Li), manganese (Mn), nickel (Ni), lead (Pb), rubidium (Rb), tin (Sn), strontium (Sr), titanium (Ti), vanadium (V), chromium (Cr), copper (Cu), iron (Fe), and zinc (Zn) were determined by inductively coupled plasma mass spectrometry. Differences in elemental concentrations between groups were assessed with Kruskal-Wallis test. Binary logistic regression was used to examine the association between elemental concentrations and disease odds. Spearman's Rho (ρ) correlation coefficients and partial correlation networks were employed to assess elemental concentration correlations for each group. Results: We found significantly higher levels of Rb, and Fe, and lower Sr and Li concentrations in the PF of patients with endometriosis. Adjusted odds ratios (aOR) showed that higher Rb concentration was associated with increased odds of endometriosis (aOR = 1.02, 95 % CI: 1.00–1.04), while higher Sr was linked to reduced odds (aOR = 0.93, 95 % CI: 0.88–0.99). Different correlation and association patterns were observed between elemental concentrations in the control and endometriosis groups. Conclusions: Data from this study show different levels of PTEs, trace, and ultra-trace elements in the PF of endometriosis subjects. This suggests environmental exposures and/or pathophysiological and metabolic alterations are associated with the disease.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Synergistic energy-efficient capture of VOCs and metal-free catalytic conversion using magneto-inductive Guefoams: Proof-of-concept in n-hexane-enriched nitrogen streams

  • Verdú Molina, Noelia
  • Molina Jordá, José Miguel
  • Molina Jordá, José Miguel|||/items/04e52741-4cf2-482e-a208-79f3a27350e7
Addressing contemporary environmental and health concerns requires reducing pollutant emissions and converting them into less harmful or valuable compounds within the framework of the circular economy. Guefoam materials offer a promising solution by enabling the capture and pre-concentration of volatile organic compounds (VOCs), while facilitating the structuring of active phases for heterogeneous catalytic conversions. This study demonstrates the benefits of merging two newly designed electromagnetic induction-assisted ceramic matrix Guefoams into a portable integrated unit, synergizing the pre-concentration and chemical transformation of n-hexane, a VOC with special challenges. One Guefoam serves as an adsorbent, whereas the other plays a catalytic role. These Guefoams host guest phases, which consist of composite materials combining a steel core with magneto-inductive properties encased in a highly porous carbonaceous layer. This carbonaceous material undertakes a dual mission: adsorbing n-hexane from a nitrogen stream within the adsorptive Guefoam and, upon phosphorus doping in the catalytic Guefoam, orchestrating the metal-free selective dehydroaromatization of n-hexane into benzene. The design and integration of these novel Guefoam materials into a unified functional entity prove highly effective in pre-concentrating (enrichment factors up to 275) and catalyzing n-hexane with up to 84 % conversion and 94 % benzene selectivity while remaining energy-efficient and environmentally sustainable.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Analytical Determination of Heavy Metals in Human Seminal Plasma—A Systematic Review

  • López-Botella, Andrea
  • Sánchez, Raquel
  • Paul, Raiza
  • Aizpurua, Jon
  • Gómez-Torres, María José
  • Todolí Torró, José Luis
  • Gómez-Torres, María José|||/items/98e76526-8bb1-4710-9b76-59f6fadc332c
  • López-Botella, Andrea|||/items/b997136f-08a8-46c7-8e40-df117c325947
  • Sánchez, Raquel|||/items/06c6cd36-b88e-43e0-929a-9b92d670da54
  • Todolí Torró, José Luis|||/items/e63cf980-21e8-48ec-8493-cdb380f1cccc
Infertility is a growing concerning health problem affecting around 15% of couples worldwide. Conventional semen parameters have limited accuracy for male infertility potential determination. Current advances in the understanding of male infertility indicate that environmental and occupational exposure to chemical contaminants are important etiological factors leading to infertility problems. In this context, some heavy metals (HMs) can be considered as endocrine-disrupting compounds (EDCs), thus altering the seminal quality. This systematic review aims to summarize the key points to detect and quantify HMs in human seminal plasma (SP) and the involved analytical tools. Our results showed that that for HM quantification, atomic absorption spectroscopy (AAS) and inductively coupled plasma (ICP) were the most employed techniques while Zn, Cd, Pb, and Cr were the analytes most often detected. Fast, reliable, and sensitive quantification of EDCs in SP could be important for the development of accurate diagnostic and preventive strategies to address male infertility towards providing personalized therapy.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Sustainable assembling of graphite flakes into graphite/carbon composite foams with thermal percolative interfaces for active heat dissipation

  • Maiorano Lauría, Lucila Paola
  • Verdú Molina, Noelia
  • Molina Jordá, José Miguel
  • Maiorano Lauría, Lucila Paola|||/items/f667840c-2310-43e7-bfb3-3c98cd06e781
  • Molina Jordá, José Miguel|||/items/04e52741-4cf2-482e-a208-79f3a27350e7
Current methods for producing open-pore graphite foams with heat dissipation potential involve costly graphitization processes, limiting their widespread use. This study presents a sustainable approach to fabricate high-performance graphite/carbon composite foams with porosities in the range of 49–82 %. The method involves the densification and carbonization of solid mixtures comprising natural graphite flakes, sucrose, and NaCl particles. The dissolution of NaCl creates coarse pores, while carbonized sucrose contributes fine porosity and serves as a binder to impart mechanical stability, ensuring the maintenance of thermally conductive percolative contacts between flakes. The composite foams exhibit thermal conductivities of up to 91 Wm−1K−1, permeability values in the range of 10−11–10−10 m2, and excellent mechanical properties. Experimental and computational findings demonstrate that the developed materials surpass the heat dissipation capabilities of conventional heat sinks based on graphite and aluminum foams by about 3 and 1.5 times, respectively, making them excellent candidates for thermal management applications.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Pilot-Scale Development of Biodegradable Packaging Incorporating Pineapple By-product Antioxidants for Sustainable Meat Preservation Through Circular Economy

  • Beltrán Sanahuja, Ana
  • Valdés, Arantzazu
  • Cenitagoya Alonso, Natalia
  • Sánchez, Raquel
  • Tone, Ana María
  • Herranz Solana, Nuria
  • Sánchez Reig, Carmen
  • Monedero Prieto, María
  • Todolí Torró, José Luis
  • Beltrán Sanahuja, Ana|||/items/e050de26-d5fa-4bc8-8092-760c0d8865d0
  • Sánchez, Raquel|||/items/06c6cd36-b88e-43e0-929a-9b92d670da54
  • Todolí Torró, José Luis|||/items/e63cf980-21e8-48ec-8493-cdb380f1cccc
  • Valdés, Arantzazu|||/items/4014bcef-f512-4723-8000-650f5d9ad7e9
This pilot-scale study explores the development of biodegradable poly(Ɛ-caprolactone) (PCL) films incorporating antioxidants extracted from pineapple by-products to enhance meat preservation. Pineapple core extracts, rich in phenolic compounds, were obtained through ultrasound-assisted extraction (70% amplitude, 5 min, 2 cycles), followed by fermentation and encapsulation using whey protein isolate (WPI) to improve stability and thermal resistance. Fermented pineapple extract (FPE) showed a significant increase in succinic acid, which rose from 12.0 ± 0.2 mg/100 g in non-fermented extract (PE) to 1120 ± 20 mg/100 g. Encapsulation efficiencies (EE) for fermented and non-fermented extracts were 87.4% and 89.1%, respectively, with encapsulated FPE (EFPE) exhibiting the highest onset degradation temperature (128 ± 2 °C), indicating enhanced thermal stability. Incorporation of these extracts into PCL films resulted in notable changes in mechanical and optical properties. The Young’s modulus decreased from 296 ± 8 MPa in pure PCL to 233 ± 6 MPa in PCL/EPE, and 264 ± 13 MPa in PCL/EFPE, reflecting reduced stiffness. Total phenolic content in PCL/EPE and PCL/EFPE films was approximately 10 and 15 times higher, respectively, than in pure PCL. The films significantly reduced lipid oxidation in burger meat, as evidenced by lower TBARS values, extending freshness by over 10%. This approach supports circular economy principles by valorizing agricultural waste and meets consumer demand for sustainable, natural packaging solutions, offering a scalable alternative to conventional food packaging.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Multielemental Profile for Seminal Plasma Through Inductively Coupled Plasma–Tandem Mass Spectrometry and Its Relationship with Seminal Parameters, Spermatic Biomarkers, and Oxidative Stress

  • López-Botella, Andrea|||/items/b997136f-08a8-46c7-8e40-df117c325947
  • Cenitagoya Alonso, Natalia
  • Sánchez, Raquel|||/items/06c6cd36-b88e-43e0-929a-9b92d670da54
  • Sáez Espinosa, Paula|||/items/3fd4030e-be3f-4920-9a84-59ec1fbcd61c
  • Hernández-Falcó, Miranda|||/items/b426ed79-08e7-4af0-804d-aedf182d1400
  • Gómez-Torres, María José|||/items/98e76526-8bb1-4710-9b76-59f6fadc332c
  • Todolí Torró, José Luis|||/items/e63cf980-21e8-48ec-8493-cdb380f1cccc
The present study investigated the decline in human fertility by analyzing the multielemental profile of seminal plasma and its relationship with seminal parameters and sperm biomarkers. Twenty-nine donor seminal plasma samples were examined using inductively coupled plasma–tandem mass spectrometry (ICP-MS/MS). Method optimization demonstrated that robust plasma conditions, including internal standardization and helium (He) collision gas, were essential to achieve reliable quantification. These conditions mitigated matrix effects and spectroscopic interferences, despite lower sensitivity. Elements such as copper (Cu), iron (Fe), manganese (Mn), strontium (Sr), titanium (Ti), vanadium (V), and chromium (Cr) were quantified, and several significant correlations were identified. Specifically, Cu was negatively correlated with seminal volume and positively correlated with sperm concentration and spontaneous acrosome reacted sperm, but negatively correlated with medium mitochondrial membrane potential (MMP); Mn showed negative associations with sperm vitality and medium MMP; Fe showed a negative correlation with motile sperm concentration (4 h); V was positively correlated with acrosome reacted sperm after acrosome reaction induction and with very low/medium MMP, whereas it was negatively associated with tyrosine phosphorylation; and Cr also showed a negative correlation with tyrosine phosphorylation. As, Mo, and Pb were detected in a few samples, limiting correlation analysis. From a functional perspective, elements such as As and Pb, as well as excess Cu or Fe, may contribute to oxidative stress by enhancing reactive oxygen species (ROS) generation and impairing antioxidant defenses. Conversely, essential metals, including Mn and Cu, at physiological concentrations act as cofactors of antioxidant enzymes and play a protective role against oxidative damage.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Development and Validation of an ICP-MS/MS Method for the Multielemental Analysis of Cerebrospinal Fluid, Examination of Alzheimer's Disease Samples

  • Pérez-Ramírez, Rebeca
  • Cuchillo-Ibáñez, Inmaculada
  • Sánchez-Romero, Raquel
  • Beltrán-Sanahuja, Ana
  • Escamilla, Sergio
  • Molina-Gasset, Ricardo
  • Zetterberg, Henrik
  • Blennow, Kaj
  • Sáez-Valero, Javier
  • Todolí-Torró, José Luis
Multielemental analysis of cerebrospinal fluid (CSF) yields critical insights into the pathophysiology of neurological disorders and holds potential as a diagnostic and predictive tool for Alzheimer's disease (AD). The present work presents the development and validation of an inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) based method for multielemental determination in CSF, including metals and metalloids as analytes. As a proof of concept, the importance of the CSF element determination was evaluated in a cohort of patients with AD (n = 20) and non-AD controls (n = 19) who displayed typical levels of core CSF biomarkers (Aβ42, P-tau, and total-tau). Discrete sample introduction ICP-MS/MS procedure was effective for accurate and precise CSF analysis. The methodology provided better sensitivities and limits of detection than a conventional one based on sample dilution and analysis in continuous sample introduction mode, while only requiring a 20 μL CSF sample volume. A total of 24 elements were encountered and quantified in CSF, with reduced levels of Mn, Cr, Se, Fe, and Zn in the CSF from AD patients and increased levels of Ag and Bi, compared with non-AD patients. Particularly, Mn fully discriminated AD from non-AD subjects, with binary regression analysis indicating that Mn was the most effective element to distinguish between AD and non-AD groups. Furthermore, distinctive correlation profiles were found between AD and non-AD controls for elements with AD core biomarkers and the alternative amyloidogenic sAPPβ fragment. Quantitative determination of metals, metalloids and non-metals displays differences associated with pathological status, serving as additional biomarkers for neurological diseases., The authors wish to thank the Spanish State Research Agency (AEI) from the Ministry of Science, Innovation, and Universities for the financial support (Project Ref. PID2021-127566NB-I00). This work was also supported by grants from the Fondo de Investigaciones Sanitarias (PI22/01329, co-funded by the Fondo Europeo de Desarrollo Regional, FEDER “Investing in your future”), CIBERNED (Instituto de Salud Carlos III, Spain), the Direcció General de Ciència i Investigació, Generalitat Valenciana (AICO/2021/308) and by the Spanish State Research Agency (AEI/10.13039/501100011033), through the “Severo Ochoa” Center of Excellence grant to the IN (CEX2021-001165-S). SE is supported by a PFIS fellowship from the ISC-III. H.Z. is a Wallenberg scholar and a distinguished professor at the Swedish Research Council supported by grants from the Swedish Research Council (#2023-00356, #2022-01018, and #2019-02397), the European Union's Horizon Europe research and innovation program under grant agreement No 101053962, and Swedish State Support for Clinical Research (#ALFGBG-71320)., With funding from the Spanish government through the "Severo Ochoa Centre of Excelence" accreditation (CEX2021-001165-S), Peer reviewed