MEJORA DE LAS TERAPIAS ABLATIVAS DE VANGUARDIA MEDIANTE EL CONTROL DEL COMPORTAMIENTO TISULAR Y CELULAR USANDO CAMPOS ELECTROMAGNETICOS

PID2022-136273OB-C31

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2022
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 19
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Electrical conductivity measurement in human liver tissue, assessment on normal vs. tumor tissue and under in vivo vs. ex vivo conditions

  • Sarreshtehdari, Amirhossein
  • García Sánchez, Tomás
  • Sánchez Velázquez, Patricia|||0000-0002-7902-3920
  • Ielpo, Benedetto|||0000-0003-3129-3208
  • Berjano, Enrique|||0000-0002-3247-2665
  • Villamonte, Maria
  • Moll, Xavier|||0000-0002-2992-9361
  • Burdío, Fernando|||0000-0003-3038-0086
Background: This study evaluated electrical conductivity in human liver tissue in the 3-1000 kHz frequency range to compare normal versus tumor tissues under in vivo versus ex vivo conditions. Methods: Previous informed consent was obtained from twenty patients undergoing liver resection in whom liver electrical conductivity was measured during surgery and after resection. Result: We found higher electrical conductivity values in tumor tissues than in normal tissue in both in vivo (0.41 ± 0.10 vs. 0.13 ± 0.06 S/m) and ex vivo (0.27 ± 0.09 vs. 0.12 ± 0.07 S/m) conditions (at 3 kHz). The electric properties also showed a promising potential for distinguishing between different tissue types including metastasis, cholangiocarcinoma (CCA), hepatocellular carcinoma (HCC), hepatic cirrhosis, and normal liver (both in vivo and ex vivo). At 3 kHz, in vivo electrical conductivity for cholangiocarcinoma, HCC, and metastasis were 0.35, 0.42 ± 0.13, and 0.41 ± 0.08 S/m, respectively, which differed significantly from each other (p < 0.05). Conclusions: These findings could potentially improve liver disease diagnostics through electrical conductivity measurements and treatment techniques involving electric fields. Future research should focus on expanding the sample size to refine the categorization and comparison processes across diverse human liver tissue types.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Electrical conductivity measurement in human liver tissue: assessment on normal vs. tumor tissue and under in vivo vs. ex vivo conditions

  • Sarreshtehdari, Amirhossein
  • García Sánchez, Tomás
  • Sánchez Velázquez, Patricia, 1985-
  • Ielpo, Benedetto
  • Berjano, Enrique J.
  • Villamonte, Maria
  • Moll, Xavier
  • Burdío Pinilla, Fernando
Background: This study evaluated electrical conductivity in human liver tissue in the 3-1000 kHz frequency range to compare normal versus tumor tissues under in vivo versus ex vivo conditions. Methods: Previous informed consent was obtained from twenty patients undergoing liver resection in whom liver electrical conductivity was measured during surgery and after resection. Result: We found higher electrical conductivity values in tumor tissues than in normal tissue in both in vivo (0.41 ± 0.10 vs. 0.13 ± 0.06 S/m) and ex vivo (0.27 ± 0.09 vs. 0.12 ± 0.07 S/m) conditions (at 3 kHz). The electric properties also showed a promising potential for distinguishing between different tissue types including metastasis, cholangiocarcinoma (CCA), hepatocellular carcinoma (HCC), hepatic cirrhosis, and normal liver (both in vivo and ex vivo). At 3 kHz, in vivo electrical conductivity for cholangiocarcinoma, HCC, and metastasis were 0.35, 0.42 ± 0.13, and 0.41 ± 0.08 S/m, respectively, which differed significantly from each other (p < 0.05). Conclusions: These findings could potentially improve liver disease diagnostics through electrical conductivity measurements and treatment techniques involving electric fields. Future research should focus on expanding the sample size to refine the categorization and comparison processes across diverse human liver tissue types., Spanish Ministerio de Ciencia e Innovación, Agencia Estatal de Investigación, Fondo Europeo de Desarrollo Regional (Grants PID2022-136273OB-C31 and PID2022-136273OB-C32 funded by MCIN/AEI/10.13039/501100011033/FEDER, UE).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Computer Modeling of the Influence of Surrounding Tissues on Electrical Current Delivered to the Median Nerve During Neuromodulation for Pain Relief

  • Fernandez-Corazza, Mariano
  • Reina, Miguel A.
  • Muñoz, Victor
  • Boezaart, Andre P.
  • Ribes Llario, Carmina
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] Background: Peripheral nerve stimulation is an effective neuromodulation technique for pain management. However, the effect of surrounding tissue composition on electric field distribution remains not well understood. This study uses computational modeling to quantify the way different tissue types affect the electric field at the nerve surface. Materials and Methods: A finite element model was developed based on histologic analyses of the human median nerve and its surrounding tissues. The model included various tissue configurations, such as fat, muscle, tendon, blood vessels, and bone, to simulate six different electrode placement scenarios. The z-component of the electric field vector (aligned with the nerve axis) was calculated to evaluate stimulation efficacy. Results: The tissue between the electrode and the nerve strongly influenced the intensity of the electric field at the surface of the nerve. Fat, which possesses the lowest electrical conductivity, yielded the highest electric field values, whereas muscle and tendon significantly reduced field intensity, necessitating increased current for comparable stimulation. Moreover, the presence of nearby structures, such as blood vessels (which have high conductivity) or bone (which has low conductivity), modulated the field, either slightly decreasing or increasing its intensity, respectively. Conclusion: These findings underscore the critical role of tissue composition in the effectiveness of peripheral nerve stimulation. Optimizing lead placement by considering tissue conductivity can enhance therapeutic outcomes. Computational modeling may serve as a valuable tool for customizing surgical planning to the individual patient, improving electrode positioning and stimulation efficiency., This work was supported by the Spanish Ministerio de Ciencia e Innovacion, Agencia Estatal de Investigacion, Fondo Europeo de Desarrollo Regional: Grant PID2022-136273OB-C31 funded by MICIU/AEI/10.13039/501100011033 and by ERDF/EU, National University of La Plata, Argentina: Grant 11/EI003.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Analytical model of large-diameter spherical-like catheter for pulsed field ablation in treating cardiac arrhythmias

  • Pérez, Juan J|||0000-0001-8486-8699
  • González-Suárez, Ana|||0000-0002-1813-4176
  • Izquierdo, Maite
[EN] Objective. To study the electrical performance of large-diameter spherical-like catheters used for pulsed field ablation (PFA) in treating cardiac arrhythmias, especially evaluating the effect of electrode radius, applied voltage and maximum current delivered on the PFA-induced lesion depth. Approach. An analytical model was proposed which used spherical coordinates to estimate the value of the electric field around a spherical metal electrode. Lesion depth was estimated by the myocardium lethal electric field threshold. The paper also reviews the literature and proposes a relationship between this threshold and the total cumulative duration of the pulses applied during PFA. Main results. Despite the models simplicity in geometric terms, the estimated values of baseline impedance (44 Omega) and impedance drop due to PFA (7-9 Omega) are closely related to those observed in experimental studies (43 Omega and 5-7 Omega, respectively). The PFA-induced lesion size potentially increases with the applied voltage, but this is only true if the generator can provide the electrical current needed to maintain the required voltage. A nonlinear relationship was identified between PFA-induced lesion depth and the electrode diameter, which was also modulated by the total duration. Significance. The analytical model offers a physical explanation for the PFA-Induced electrical phenomenon, while emphasising how certain technical characteristics (maximum current, applied voltage, electrode diameter) can affect the depth of the lesion., Spanish Ministerio de Ciencia e Innovacion, Agencia Estatal de Investigacion, Fondo Europeo de Desarrollo Regional (Grants PID2022-136273OB-C3, PID2022-136273OA-C33 and RYC2022-036965-I funded by MICIU /AEI/10.13039/501100011033/ERDF/EU and by MICIU/AEI/10.13039/501100011033/ESF+).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Proactive esophageal cooling during laser cardiac ablation: A computer modeling study

  • Gomez Bustamante, Tatiana
  • Mercado Montoya, Marcela
  • Kulstad, Erik
  • Berjano, Enrique|||0000-0002-3247-2665
  • González-Suárez, Ana|||0000-0002-1813-4176
[EN] Background and ObjectivesLaser ablation is increasingly used to treat atrial fibrillation (AF). However, atrioesophageal injury remains a potentially serious complication. While proactive esophageal cooling (PEC) reduces esophageal injury during radiofrequency ablation, the effects of PEC during laser ablation have not previously been determined. We aimed to evaluate the protective effects of PEC during laser ablation of AF by means of a theoretical study based on computer modeling.MethodsThree-dimensional mathematical models were built for 20 different cases including a fragment of atrial wall (myocardium), epicardial fat (adipose tissue), connective tissue, and esophageal wall. The esophagus was considered with and without PEC. Laser-tissue interaction was modeled using Beer-Lambert's law, Pennes' Bioheat equation was used to compute the resultant heating, and the Arrhenius equation was used to estimate the fraction of tissue damage (FOD), assuming a threshold of 63% to assess induced necrosis. We modeled laser irradiation power of 8.5 W over 20 s. Thermal simulations extended up to 250 s to account for thermal latency.ResultsPEC significantly altered the temperature distribution around the cooling device, resulting in lower temperatures (around 22 degrees C less in the esophagus and 9 degrees C in the atrial wall) compared to the case without PEC. This thermal reduction translated into the absence of transmural lesions in the esophagus. The esophagus was thermally damaged only in the cases without PEC and with a distance equal to or shorter than 3.5 mm between the esophagus and endocardium (inner boundary of the atrial wall). Furthermore, PEC demonstrated minimal impact on the lesion created across the atrial wall, either in terms of maximum temperature or FOD.ConclusionsPEC reduces the potential for esophageal injury without degrading the intended cardiac lesions for a variety of different tissue thicknesses. Thermal latency may influence lesion formation during laser ablation and may play a part in any collateral damage.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

How intramyocardial fat can alter the electric field distribution during Pulsed Field Ablation (PFA): Qualitative findings from computer modeling.

  • Pérez, Juan J|||0000-0001-8486-8699
  • González-Suárez, Ana|||0000-0002-1813-4176
[EN] Even though the preliminary experimental data suggests that cardiac Pulsed Field Ablation (PFA) could be superior to radiofrequency ablation (RFA) in terms of being able to ablate the viable myocardium separated from the catheter by collagen and fat, as yet there is no formal physical-based analysis that describes the process by which fat can affect the electric field distribution. Our objective was thus to determine the electrical impact of intramyocardial fat during PFA by means of computer modeling. Computer models were built considering a PFA 3.5-mm blunt-tip catheter in contact with a 7-mm ventricular wall (with and without a scar) and a 2-mm epicardial fat layer. High voltage was set to obtain delivered currents of 19, 22 and 25 A. An electric field value of 1000 V/cm was considered as the lethal threshold. We found that the presence of fibrotic tissue in the scar seems to have a similar impact on the electric field distribution and lesion size to that of healthy myocardium only. However, intramyocardial fat considerably alters the electrical field distribution and the resulting lesion shape. The electric field tends to peak in zones with fat, even away from the ablation electrode, so that 'cold points' (i.e. low electric fields) appear around the fat at the current entry and exit points, while 'hot points' (high electric fields) occur in the lateral areas of the fat zones. The results show that intramyocardial fat can alter the electric field distribution and lesion size during PFA due to its much lower electrical conductivity than that of myocardium and fibrotic tissue., Funded by the Spanish Ministerio de Cienciae Innovacion / Agencia Estatal de Investigacion (MCIN/AEI/10.13039/501100011033) with Grant number PID2022-136273OB-C31 and PID2022-136273OA-C33. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Impact of surrounding tissue-type and peri-electrode gap in stereoelectroencephalography guided (SEEG) radiofrequency thermocoagulation (RF-TC): a computational study

  • Collavini, Santiago
  • Fernández-Corazza, Mariano
  • Oddo, Silvia
  • Irastorza, Ramiro Miguel
  • Pérez, Juan J|||0000-0001-8486-8699
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] Purpose: To use computational modeling to provide a complete and logical description of the electrical and thermal behavior during stereoelectroencephalography-guided (SEEG) radiofrequency thermocoagulation (RF-TC). Methods: A coupled electrical-thermal model was used to obtain the temperature distributions in the tissue during RF-TC. The computer model was first validated by an ex vivo model based on liver fragments and later used to study the impact of three different factors on the coagulation zone size: 1) the difference in the tissue surrounding the electrode (gray/white matter), 2) the presence of a peri-electrode gap occupied by cerebrospinal fluid (CSF), and 3) the energy setting used (power-duration). Results: The model built for the experimental validation was able to predict both the evolution of impedance and the short diameter of the coagulation zone (error < 0.01mm) reasonably well but overestimated the long diameter by 2¿3mm. After adapting the model to clinical conditions, the simulation showed that: 1) Impedance roll-off limited the coagulation size but involved overheating (around 100°C); 2) The type of tissue around the contacts (gray vs. white matter) had a moderate impact on the coagulation size (maximum difference 0.84mm), and 3) the peri-electrode gap considerably altered the temperature distributions, avoided overheating, although the diameter of the coagulation zone was not very different from the no-gap case (<0.2mm). Conclusions: This study showed that computer modeling, especially subject- and scenario-specific modeling, can be used to estimate in advance the electrical and thermal performance of the RF-TC in brain tissue., Spanish Ministerio de Ciencia e Innovación, Agencia Estatal de Investigación, Fondo Europeo de Desarrollo Regional (Grant PID2022-136273OB-C31 funded by MCIN/AEI/10.13039/501100011033/FEDER, UE), Argentinean National Agency for the Promotion of Science and Technology ANPCyT (PICT 2019-0701, PICT 2020-00457), CONICET Argentina (PIP 11220200101515CO), and Universidad Tecnológica Nacional (PID Grant No. MAECLP0009851TC).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

A fundamentals-based vaporization model for radiofrequency ablation of biological tissues: Comparison with the enthalpy method

  • Bon Corbín, José|||0000-0002-0457-9705
  • Berjano, Enrique|||0000-0002-3247-2665
  • Trujillo Guillen, Macarena|||0000-0003-4145-2188
[EN] Intratissue vaporization is a crucial phenomenon to be considered in the theoretical modeling of the radiofrequency ablation (RFA) of biological tissues. The enthalpy method (EM) is one of the most common methods to model it. However, this method does not consider either the vapor pressure or the water content in gas phase and consequently does not realistically consider vaporization. Our objective was to develop a new fully coupled model (FCM) for liver RFA including a multiphase porous media model as well as the vapor pressure and the fraction of water in form of liquid and gas. The results show that the FCM can efficiently calculate the vapor pressure and the water content in all the points and times during the RFA, what differences this model from other existing models. As compared to EM, the FCM presents a more uniform solution without unrealistic fluctuations in the temperature and electrical impedance progresses., This research was funded by Spanish Ministerio de Ciencia e Innovacion, Agencia Estatal de Investigacion, Fondo Europeo de Desarrollo Regional (Grant PID2022-136273OBC31 funded by MCIN/AEI/10.13039/501100011033/FEDER, UE) .
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Enhancing Precision in Window to the Brain Modeling: Methodology and Implementation of Hybrid Digital Twins

  • Llamazares-López, Marcos
  • Trujillo Guillen, Macarena|||0000-0003-4145-2188
  • Cortés, J.-C.|||0000-0002-6528-2155
  • Villanueva Micó, Rafael Jacinto|||0000-0002-0131-0532
[EN] The Window to the Brain (WttB) is a novel cranial implant designed to enhance therapeutic procedures involving brain tissue. Previous computational models studying the effectiveness of the WttB exhibited some discrepancies with experimental results and inconsistencies in certain parameter values. To overcome these drawbacks, the following steps are followed. We first perform a domain reduction where the model is solved via the finite element method. Then, model parameters are calibrated using asynchronous random Particle Swarm Optimization (arPSO) algorithm. A statistical identifiability analysis is performed to evaluate how accurately model parameters are estimated based on the quantity and quality of experimental data. Afterward, we implement Hybrid Digital Twins (HDT) using Grammatical Evolution and Lexicase Selection to improve the model fitting keeping the model complexity. The outcomes demonstrate a complete alignment between experimental and computational results, as well as reasonable values for all model parameters. The final optimized model achieved a mean absolute error of 0.1871, with a standard deviation of 0.0013 and a 95% confidence interval (CI) of [0.1866, 0.1876], indicating a very low residual error and high stability across simulations. Our computational approach enhances the results from previous studies, which can be more useful for improving clinical practice., Financial support: Spanish Ministerio de Ciencia e Innovación, Agencia Estatal de Investigación, Fondo Europeo de Desarrollo Regional (Grant PID2022-136273OB-C31 funded by MCIN/AEI/10.13039/501100011033/FEDER, UE).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Proactive esophageal cooling during radiofrequency cardiac ablation: data update including applications in very high-power short duration ablation

  • Sharkoski, Tiffany
  • Zagrodzky, Jason
  • Warrier, Nikhil
  • Doshi, Rahul
  • Omotoye, Samuel
  • Mercado Montoya, Marcela
  • Gomez Bustamante, Tatiana
  • Kulstad, Erik
  • Metzl, Mark
  • Berjano, Enrique|||0000-0002-3247-2665
  • González-Suárez, Ana|||0000-0002-1813-4176
[EN] Introduction Proactive esophageal cooling reduces injury during radiofrequency (RF) ablation of the left atrium (LA) for the treatment of atrial fibrillation (AF). New catheters are capable of higher wattage settings up to 90 W (very high-power short duration, vHPSD) for 4 s. Varying power and duration, however, does not eliminate the risk of thermal injury. Furthermore, alternative energy sources such as pulsed field ablation (PFA) also exhibit thermal effects, with clinical data showing esophageal temperatures up to 40.3°C. The ensoETM esophageal cooling device (Attune Medical, now a part of Haemonetics, Boston, MA, U.S.A.) is commercially available and FDA-cleared to reduce thermal injury to the esophagus during RF ablation for AF and is recommended in the 2024 expert consensus statement on catheter and surgical ablation of AF. Areas covered This review summarizes growing evidence of esophageal cooling during high power RF ablation for AF treatment, including data relating to procedural efficacy, safety, and efficiency, and techniques to enhance operator success while providing directions for further research. Expert opinion Proactive esophageal cooling reduces injury to the esophagus during high power RF ablation, and utilizing this approach may result in increased success in first-pass isolation, procedural efficiency, and long-term efficacy. Plain Language Summary Atrial fibrillation is a condition that causes the heart to beat irregularly, which then may cause symptoms such as palpitations, shortness of breath, dizziness, and chest pain. Atrial fibrillation increases a person¿s risk of heart failure, dementia, stroke, and death. Radiofrequency catheter ablation is a frequently employed treatment option for atrial fibrillation. This is an elective procedure performed by specialty physicians called electrophysiologists. This treatment uses a thermal (heat) energy source to create scars in the heart that block the irregular or chaotic heartbeats. There are multiple approaches to delivering this energy, including delivering moderate energy over a specified time frame as well as delivering very high amounts of energy over a much-shortened time frame. Despite the approach used, one complication of this type of energy delivery is unintended injury to the esophagus, the organ behind the heart that passes food from the mouth to the stomach. In severe cases, this injury can develop into an atrioesophageal fistula, an abnormal connection between the heart and the esophagus, which can result in death. In this review, we discuss an available device that helps prevent this type of injury in both standard and higher energy delivery, without compromising the efficacy or efficiency of the procedure., Some research reported in this publication was supported by the National Heart, Lung, and Blood Institute of the National Institutes of Health under Award Number R44HL158375 (the content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health), and the Spanish Ministerio de Ciencia e Innovacion, Agencia Estatal de Investigacion, Fondo Europeo de Desarrollo Regional [Grants PID2022-136273OA-C33 and PID2022-136273OB-C31 funded by MICIU/AEI/10.13039/501100011033/ERDF, UE, and the RYC2022-036965-I funded by MICIU/AEI/10.13039/501100011033 and ESF+].
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Characterization of the Thermal Properties of Healthy vs Infarcted Ventricular Tissue: Implications for Radiofrequency Ablation

  • Izquierdo, Maite
  • Gaona, Omérim
  • Navarro, Josep
  • Navarrete, Javier
  • Martinez-Dolz, Luis
  • Almenar, Luis
  • Cano, Oscar
  • Mancheño, Nuria
  • Osca, Joaquín
  • Pérez, Juan J|||0000-0001-8486-8699
  • González-Suárez, Ana|||0000-0002-1813-4176
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] BACKGROUND Radiofrequency (RF) ablation is the technique of choice for treating ventricular tachycardias in ischemic cardiomyopathy. However, recent experimental studies have found it to be ineffective. Poor heat transmission in collagen-rich scar tissue was 1 of the explanations given, even though the thermal properties of infarcted tissue have never been studied. OBJECTIVES The purpose of the present study was to measure the thermal properties of chronically infarcted myocardium. METHODS A total of 5 freshly explanted human hearts from patients undergoing heart transplantation with previous chronic myocardial infarction were studied in the operating room. A 2-needle thermal sensor model SH-3 Tempos (Meter Group) was introduced into different infarcted and healthy areas in the left ventricle to measure the thermal conductivity, volumetric heat capacity, and thermal diffusivity. All the measured areas were excised for histological analysis. An in silico model of radiofrequency catheter ablation was then built to evaluate the impact of the thermal parameters obtained. Stiffness, electrical properties, and vascularization were also included to simulate realistic healthy and infarcted myocardium according to previously published data. RESULTS More than one-half of the area of the infarcted samples was composed of collagen. No significant differences were found between the thermal properties of infarcted and healthy tissue. The RF lesion depths obtained from the computational model did not have any clinically relevant differences (<0.4 mm in depth) between the infarcted and healthy tissue., Funding was provided by the Spanigh Ministerior de Ciencia e Innovación (PID2022-136273OB-C31), Agencia Estatal de Investigación (PID2022-136273OA-C33), Fondo Europeo de Desarrollo Regional (RYC2022-036965-I) and Center for Biomedical Research Network on Cardiovascular Diseases (CIBERCV) (CB16/11/00261).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Body Size Modulates the Impact of the Dispersive Patch Position During Radiofrequency Cardiac Ablation.

  • Irastorza, Ramiro Miguel
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] (1) Background: In the context of cardiac radiofrequency (RF) ablation, it has been proposed that positioning the dispersive patch (DP) concordantly with the orientation of the ablation electrode may enhance lesion size. The objective of this study is to investigate how individual body size may modulate the extent of this effect. (2) Methods: Three computational models representing different body sizes were developed. An irrigated catheter ablation was simulated by delivering a 30 W pulse for 30 s to the endocardial surface of the anterior wall. Lesion sizes were then compared between two configurations of the dispersive patch (DP): an anterior (concordant) position and a posterior (discordant) position. (3) Results: Lesion size was consistently and significantly greater with concordant DP positioning compared to discordant positioning. Moreover, the magnitude of this difference decreased significantly with increasing body size, ranging from 0.65 +/- 0.08 mm in the 35 kg swine model to 0.51 +/- 0.06 mm in the human model. (4) Conclusions: Body size has a modest influence on the effect of dispersive patch positioning on RF lesion size. The potential advantage of a concordant DP configuration may be more significant in individuals with smaller body volume., This work was also supported by grants: PICT 2020-00457 (Agencia Nacional de Promocion de la Investigacion, el Desarrollo Tecnologico y la Innovacion, Argentina); PID UTN: MAECLP0009851TC (Universidad Tecnologica Nacional); PID2022-136273OB-C31 (Spanish Ministerio de Ciencia, Innovacion y Universidades, Agencia Estatal de Investigacion, Fondo Europeo de Desarrollo Regional (MICIU/AEI/10.13039/501100011033/ERDF/EU)).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Effect of dispersive electrode position (anterior vs. posterior) in epicardial radiofrequency ablation of ventricular wall: A computer simulation study

  • Irastorza, Ramiro Miguel
  • Hadid, Claudio
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] An epicardial approach is often used in radiofrequency (RF) catheter ablation to ablate ventricular tachycardia when an endocardial approach fails. Our objective was to analyze the effect of the position of the dispersive patch (DP) on lesion size using computer modeling during epicardial approach. We compared the posterior position (patient's back), commonly used in clinical practice, to the anterior position (patient's chest). The model considered ventricular wall thicknesses between 4 and 8¿mm, and electrode insertion depths between .3 and .7¿mm. RF pulses were simulated with 20¿W of power for 30¿s duration. Statistically significant differences (P¿<¿.001) were found between both DP positions in terms of baseline impedance, RF current (at 15¿s) and thermal lesion size. The anterior position involved lower impedance (130.8¿±¿4.7 vs. 146.2¿±¿4.9¿¿) and a higher current (401.5¿±¿5.6 vs. 377.5¿±¿5.1¿mA). The anterior position created lesion sizes larger than the posterior position: 8.9¿±¿0.4 vs. 8.4¿±¿0.4¿mm in maximum width, 8.6¿±¿0.4 vs. 8.1¿±¿0.4¿mm in surface width, and 4.5¿±¿0.4 vs. 4.3¿±¿0.4¿mm in depth. Our results suggest that: (1) the redirection of the RF currents due to repositioning the PD has little impact on lesion size and only affects baseline impedance, and (2) the differences in lesion size are only 0.5¿mm wider and 0.2¿mm deeper for the anterior position, which does not seem to have a clinical impact in the context of VT ablation., Spanish Ministerio de Ciencia e Innovacion; Agencia Estatal de Investigacion; Fondo Europeo de Desarrollo Regional, Grant/Award Number: PID2022-136273OBC31; Ministerio de Ciencia, Tecnología e Innovacion de Argentina, Agencia Nacional de Promocion de la Investigacion, el Desarrollo Tecnologico; Universidad Tecnologica Nacional, Grant/Award Number: MAECLP0009851TC
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Impact of Intrapericardial Fluid on Lesion Size During Epicardial Radiofrequency Ablation: A Computational Study

  • Luis
  • Berjano, Enrique|||0000-0002-3247-2665
  • Pérez, Juan J|||0000-0001-8486-8699
  • González-Suárez, Ana|||0000-0002-1813-4176
  • Mercado Montoya, Marcela
  • Gomez Bustamante, Tatiana
  • Izquierdo, Maite
  • Lozano, José M.
[EN] Background and aims: Epicardial RFA is often required when ventricular tachyarrhythmias originate from epicardial or subepicardial substrates that cannot be effectively ablated endocardially. Our objective was to evaluate the impact of intrapericardial fluid accumulation on the lesion size in the myocardium and the extent of thermal damage to adjacent structures, particularly the lung. Methods: An in silico model of epicardial RFA was developed, featuring an irrigated-tip catheter placed horizontally on the epicardium. A 50 W-30 s RF pulse was simulated. Temperature distributions and resultant thermal lesions in both the myocardium and lung were computed. Results: An increase in pericardial space from 2.5 mm to 4.5 mm resulted in a reduction of myocardial lesion depth by up to 1 mm, while the volume of lung damage decreased from 200 to 300 mm3 to nearly zero, irrespective of myocardial or epicardial fat thickness. Myocardial lesion size was markedly influenced by the thickness of the epicardial fat layer. In the absence of fat and with a narrow pericardial space, lesions reached up to 262 mm3 in volume and 6.1 mm in depth. With 1 mm of fat, lesion volume decreased to below 100 mm3 and depth to 3 mm; with 2 mm, to under 40 mm3 and 2 mm; and with 3 mm, to less than 16 mm3 and 1.2 mm. Lung damage increased moderately with greater fat thickness. Cooling the irrigation fluid from 37 C to 5 C reduced lung damage by up to 51%, while myocardial lesion size decreased by only 15%. Conclusions: Intrapericardial fluid accumulation can limit myocardial lesion formation while protecting adjacent structures. Cooling the irrigation fluid may reduce collateral damage without compromising myocardial lesion depth., Spanish Ministerio de Ciencia, Innovación y Universidades, Agencia Estatal de Investigación, Fondo Europeo de Desarrollo Regional: Grants PID2022-136273OB-C31 and PID2022-136273OA-C33 funded by MICIU/AEI/10.13039/501100011033 and by ERDF/EU.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Electrical conductivity measurement in human liver tissue: assessment on normal vs. tumor tissue and under in vivo vs. ex vivo conditions

  • Sarreshtehdari, Amirhossein
  • García-Sánchez, Tomás
  • Sánchez-Velázquez, Patricia
  • Ielpo, Benedetto
  • Villamonte, Maria
  • Moll, Xavier
  • Burdio, Fernando
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] This study evaluated electrical conductivity in human liver tissue in the 3¿1000 kHz frequency range to compare normal versus tumor tissues under in vivo versus ex vivo conditions. Methods: Previous informed consent was obtained from twenty patients undergoing liver resection in whom liver electrical conductivity was measured during surgery and after resection. Result: We found higher electrical conductivity values in tumor tissues than in normal tissue in both in vivo (0.41 ± 0.10 vs. 0.13 ± 0.06 S/m) and ex vivo (0.27 ± 0.09 vs. 0.12 ± 0.07 S/m) conditions (at 3 kHz). The electric properties also showed a promising potential for distinguishing between different tissue types including metastasis, cholangiocarcinoma (CCA), hepatocellular carcinoma (HCC), hepatic cirrhosis, and normal liver (both in vivo and ex vivo). At 3 kHz, in vivo electrical conductivity for cholangiocarcinoma, HCC, and metastasis were 0.35, 0.42 ± 0.13, and 0.41 ± 0.08 S/m, respectively, which differed significantly from each other (p < 0.05). Conclusions: These findings could potentially improve liver disease diagnostics through electrical conductivity measurements and treatment techniques involving electric fields. Future research should focus on expanding the sample size to refine the categorization and comparison processes across diverse human liver tissue types., Spanish Ministerio de Ciencia e Innovación, Agencia Estatal de Investigación, Fondo Europeo de Desarrollo Regional (Grants PID2022-136273OB-C31 and PID2022-136273OB-C32 funded by MCIN/AEI/10.13039/501100011033/FEDER, UE).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Impact of Power and Time in Hepatic Microwave Ablation:Effect of Different Energy Delivery Schemes

  • Trujillo Guillen, Macarena|||0000-0003-4145-2188
  • Romero-Taroncher, Antonio
  • Najafabadi, Mahtab Ebad
  • Prakash, Punit
  • Cornelis, Francois H.
[EN] Microwave ablation often involves the use of continuous energy-delivery protocols with a fixed power and time. To achieve larger ablation zones, a range of protocols and power levels have been studied in experimental studies. The objective of the present study was to develop and experimentally evaluate the performance of a coupled computational electromagnetic-bioheat transfer model of 2.45 GHz microwave ablation under a variety of continuous and pulsed power delivery schemes. The main aim was to obtain an in-depth knowledge of the influence of energy delivery settings on ablation zone profiles and thermal damage in the peri-ablation zone. In addition to the theoretical model, we evaluated the power delivery schemes using ex vivo experiments and compared them to previously published data from in vivo experiments. The results showed slight differences in terms of the ablation zone size for different power delivery schemes under ex vivo conditions, with the applied energy level being the most important factor that determines ablation zone size; however, under in vivo conditions, applying a high-power pulse prior to and following a longer constant power application (BOOKEND 95 W protocol) presented the most favorable ablation zones. Moreover, the modeling and experimental studies identified threshold applied power and ablation times beyond which increases did not yield substantive increases in ablation zone extents., This research was funded by Spanish Ministerio de Ciencia e Innovacion, Agencia Estatal de Investigacion, Fondo Europeo de Desarrollo Regional (Grant PID2022-136273OBC31 funded by MCIN/AEI/10.13039/501100011033/FEDER, UE) and in part by NIH/NCI grant R01CA218357.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Computational Assessment of Electrical and Thermal Effects of Epicardial Pulsed Field Ablation Adjacent to Stented Arteries

  • Estevez-Laborí, Francisco
  • Izquierdo, Maite
  • Coffey, Ken
  • O Brien, Barry
  • González-Suárez, Ana|||0000-0002-1813-4176
[EN] Background: Current ablation strategies for the treatment of cardiac arrhythmias remain suboptimal. Treating cardiac arrhythmias using epicardial pulsed field ablation (PFA) selectively targets ganglionated plexi (GPs) within epicardial fat, offering a promising alternative to thermal ablation. Previous computational studies lacked physiological realism, excluding catheter geometry, fluid flow and post-PFA thermal latency. This study aimed to develop a realistic 3D epicardial PFA model integrating a clinical catheter, clinical PFA parameters and a sequentially coupled electro-thermal-fluid dynamics model, including thermal latency, to assess electrical and thermal collateral effects near stented coronary arteries. Methods: The model included epicardial fat, myocardium, blood, and the left circumflex artery containing a metallic stent positioned 0.25 mm beneath the catheter electrodes. Pulses of 1000, 2000, and 2500 V (60 pulses × 100 µs, 1 Hz) were simulated to analyze electric field distribution, PFA-induced lesion volume, temperature evolution, and Arrhenius-based thermal damage, including a 90 s post-pulse period to account for thermal latency. The PFA-threshold of 1000 V/cm was considered. Results: The artery reduced PFA-induced lesion size mainly by occupying fat tissue volume, while the stent shielded the lumen without altering fat lesion volume. The presence of a stent produced localized electric field enhancement at the arterial wall, with up to 3.83% of the arterial wall volume affected by PFA in the worst-case configuration. At clinical settings (1000 V), temperature remained below 40 °C and no collateral damage occurred. Voltages > 2000 V increased arterial wall heating, with thermal damage expanding up to five-fold during latency in the epicardial fat. Myocardium remained unaffected in all cases. Conclusions: The computational model developed in this study indicates that clinically relevant PFA parameters (1000 V) produce localized electric field enhancement at the stent¿artery interface, resulting in limited collateral electrical effects in the arterial wall, while avoiding collateral thermal effects and preserving the myocardium. However, the use of higher pulse voltages can lead to delayed thermal damage within the epicardial fat., This research was funded by the Spanish Ministerio de Ciencia e Innovación, Agencia Estatal de Investigación, Fondo Europeo de Desarrollo Regional (Grants PID2022-136273OA-C33, PID2022-136273OB-C31, and RYC2022-036965-I funded by MICIU/AEI/10.13039/501100011033/ERDF/EU and by MICIU/AEI/10.13039/501100011033/ESF+).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Ablation catheter-induced mechanical deformation in myocardium: computer modeling and ex vivo experiments

  • Ijima, Yukako
  • Masnok, Kriengsak
  • Watanabe, Nobuo
  • Pérez, Juan J|||0000-0001-8486-8699
  • González-Suárez, Ana|||0000-0002-1813-4176
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] Cardiac catheter ablation requires an adequate contact between myocardium and catheter tip. Our aim was to quantify the relationship between the contact force (CF) and the resulting mechanical deformation induced by the catheter tip using an ex vivo model and computational modeling. The catheter tip was inserted perpendicularly into porcine heart samples. CF values ranged from 10 to 80 g. The computer model was built to simulate the same experimental conditions, and it considered a 3-parameter Mooney-Rivlin model based on hyper-elastic material. We found a strong correlation between the CF and insertion depth (ID) (R- 2 = 0.96, P < 0.001), from 0.7 +/- 0.3 mm at 10 g to 6.9 +/- 0.1 mm at 80 g. Since the surface deformation was asymmetrical, two transversal diameters (minor and major) were identified. Both diameters were strongly correlated with CF (R- 2 >= 0.95), from 4.0 +/- 0.4 mm at 20 g to 10.3 +/- 0.0 mm at 80 g (minor), and from 6.4 +/- 0.7 mm at 20 g to 16.7 +/- 0.1 mm at 80 g (major). An optimal fit between computer and experimental results was achieved, with a prediction error of 0.74 and 0.86 mm for insertion depth and mean surface diameter, respectively., Research reported in this publication was partially supported by the Spanish Ministerio de Ciencia e Innovación, Agencia Estatal de Investigación, Fondo Europeo de Desarrollo Regional (Grants PID2022-136273OB-C31 and PID2022-136273OA-C33 funded by MCIN / AEI/https://doi.org/10.13039/501100011033/ FEDER, UE). Ms. Ijima s stay at the Universitat Politècnica de València (Spain) was partially funded by Shibaura Institute of Technology and Japan Student Services Organization (JASSO).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Electrical conductivity measurement in human liver tissue: assessment on normal vs. tumor tissue and under in vivo vs. ex vivo conditions

  • Sarreshtehdari, Amirhossein
  • García Sánchez, Tomás
  • Sánchez Velázquez, Patricia, 1985-
  • Ielpo, Benedetto
  • Berjano, Enrique J.
  • Villamonte, Maria
  • Moll, Xavier
  • Burdío Pinilla, Fernando
Background: This study evaluated electrical conductivity in human liver tissue in the 3-1000 kHz frequency range to compare normal versus tumor tissues under in vivo versus ex vivo conditions. Methods: Previous informed consent was obtained from twenty patients undergoing liver resection in whom liver electrical conductivity was measured during surgery and after resection. Result: We found higher electrical conductivity values in tumor tissues than in normal tissue in both in vivo (0.41 ± 0.10 vs. 0.13 ± 0.06 S/m) and ex vivo (0.27 ± 0.09 vs. 0.12 ± 0.07 S/m) conditions (at 3 kHz). The electric properties also showed a promising potential for distinguishing between different tissue types including metastasis, cholangiocarcinoma (CCA), hepatocellular carcinoma (HCC), hepatic cirrhosis, and normal liver (both in vivo and ex vivo). At 3 kHz, in vivo electrical conductivity for cholangiocarcinoma, HCC, and metastasis were 0.35, 0.42 ± 0.13, and 0.41 ± 0.08 S/m, respectively, which differed significantly from each other (p < 0.05). Conclusions: These findings could potentially improve liver disease diagnostics through electrical conductivity measurements and treatment techniques involving electric fields. Future research should focus on expanding the sample size to refine the categorization and comparison processes across diverse human liver tissue types., Spanish Ministerio de Ciencia e Innovación, Agencia Estatal de Investigación, Fondo Europeo de Desarrollo Regional (Grants PID2022-136273OB-C31 and PID2022-136273OB-C32 funded by MCIN/AEI/10.13039/501100011033/FEDER, UE).