Analytical model of large-diameter spherical-like catheter for pulsed field ablation in treating cardiac arrhythmias

  • Pérez, Juan J|||0000-0001-8486-8699
  • González-Suárez, Ana|||0000-0002-1813-4176
  • Izquierdo, Maite
[EN] Objective. To study the electrical performance of large-diameter spherical-like catheters used for pulsed field ablation (PFA) in treating cardiac arrhythmias, especially evaluating the effect of electrode radius, applied voltage and maximum current delivered on the PFA-induced lesion depth. Approach. An analytical model was proposed which used spherical coordinates to estimate the value of the electric field around a spherical metal electrode. Lesion depth was estimated by the myocardium lethal electric field threshold. The paper also reviews the literature and proposes a relationship between this threshold and the total cumulative duration of the pulses applied during PFA. Main results. Despite the models simplicity in geometric terms, the estimated values of baseline impedance (44 Omega) and impedance drop due to PFA (7-9 Omega) are closely related to those observed in experimental studies (43 Omega and 5-7 Omega, respectively). The PFA-induced lesion size potentially increases with the applied voltage, but this is only true if the generator can provide the electrical current needed to maintain the required voltage. A nonlinear relationship was identified between PFA-induced lesion depth and the electrode diameter, which was also modulated by the total duration. Significance. The analytical model offers a physical explanation for the PFA-Induced electrical phenomenon, while emphasising how certain technical characteristics (maximum current, applied voltage, electrode diameter) can affect the depth of the lesion., Spanish Ministerio de Ciencia e Innovacion, Agencia Estatal de Investigacion, Fondo Europeo de Desarrollo Regional (Grants PID2022-136273OB-C3, PID2022-136273OA-C33 and RYC2022-036965-I funded by MICIU /AEI/10.13039/501100011033/ERDF/EU and by MICIU/AEI/10.13039/501100011033/ESF+).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Proactive esophageal cooling during radiofrequency cardiac ablation: data update including applications in very high-power short duration ablation

  • Sharkoski, Tiffany
  • Zagrodzky, Jason
  • Warrier, Nikhil
  • Doshi, Rahul
  • Omotoye, Samuel
  • Mercado Montoya, Marcela
  • Gomez Bustamante, Tatiana
  • Kulstad, Erik
  • Metzl, Mark
  • Berjano, Enrique|||0000-0002-3247-2665
  • González-Suárez, Ana|||0000-0002-1813-4176
[EN] Introduction Proactive esophageal cooling reduces injury during radiofrequency (RF) ablation of the left atrium (LA) for the treatment of atrial fibrillation (AF). New catheters are capable of higher wattage settings up to 90 W (very high-power short duration, vHPSD) for 4 s. Varying power and duration, however, does not eliminate the risk of thermal injury. Furthermore, alternative energy sources such as pulsed field ablation (PFA) also exhibit thermal effects, with clinical data showing esophageal temperatures up to 40.3°C. The ensoETM esophageal cooling device (Attune Medical, now a part of Haemonetics, Boston, MA, U.S.A.) is commercially available and FDA-cleared to reduce thermal injury to the esophagus during RF ablation for AF and is recommended in the 2024 expert consensus statement on catheter and surgical ablation of AF. Areas covered This review summarizes growing evidence of esophageal cooling during high power RF ablation for AF treatment, including data relating to procedural efficacy, safety, and efficiency, and techniques to enhance operator success while providing directions for further research. Expert opinion Proactive esophageal cooling reduces injury to the esophagus during high power RF ablation, and utilizing this approach may result in increased success in first-pass isolation, procedural efficiency, and long-term efficacy. Plain Language Summary Atrial fibrillation is a condition that causes the heart to beat irregularly, which then may cause symptoms such as palpitations, shortness of breath, dizziness, and chest pain. Atrial fibrillation increases a person¿s risk of heart failure, dementia, stroke, and death. Radiofrequency catheter ablation is a frequently employed treatment option for atrial fibrillation. This is an elective procedure performed by specialty physicians called electrophysiologists. This treatment uses a thermal (heat) energy source to create scars in the heart that block the irregular or chaotic heartbeats. There are multiple approaches to delivering this energy, including delivering moderate energy over a specified time frame as well as delivering very high amounts of energy over a much-shortened time frame. Despite the approach used, one complication of this type of energy delivery is unintended injury to the esophagus, the organ behind the heart that passes food from the mouth to the stomach. In severe cases, this injury can develop into an atrioesophageal fistula, an abnormal connection between the heart and the esophagus, which can result in death. In this review, we discuss an available device that helps prevent this type of injury in both standard and higher energy delivery, without compromising the efficacy or efficiency of the procedure., Some research reported in this publication was supported by the National Heart, Lung, and Blood Institute of the National Institutes of Health under Award Number R44HL158375 (the content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health), and the Spanish Ministerio de Ciencia e Innovacion, Agencia Estatal de Investigacion, Fondo Europeo de Desarrollo Regional [Grants PID2022-136273OA-C33 and PID2022-136273OB-C31 funded by MICIU/AEI/10.13039/501100011033/ERDF, UE, and the RYC2022-036965-I funded by MICIU/AEI/10.13039/501100011033 and ESF+].
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Characterization of the Thermal Properties of Healthy vs Infarcted Ventricular Tissue: Implications for Radiofrequency Ablation

  • Izquierdo, Maite
  • Gaona, Omérim
  • Navarro, Josep
  • Navarrete, Javier
  • Martinez-Dolz, Luis
  • Almenar, Luis
  • Cano, Oscar
  • Mancheño, Nuria
  • Osca, Joaquín
  • Pérez, Juan J|||0000-0001-8486-8699
  • González-Suárez, Ana|||0000-0002-1813-4176
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] BACKGROUND Radiofrequency (RF) ablation is the technique of choice for treating ventricular tachycardias in ischemic cardiomyopathy. However, recent experimental studies have found it to be ineffective. Poor heat transmission in collagen-rich scar tissue was 1 of the explanations given, even though the thermal properties of infarcted tissue have never been studied. OBJECTIVES The purpose of the present study was to measure the thermal properties of chronically infarcted myocardium. METHODS A total of 5 freshly explanted human hearts from patients undergoing heart transplantation with previous chronic myocardial infarction were studied in the operating room. A 2-needle thermal sensor model SH-3 Tempos (Meter Group) was introduced into different infarcted and healthy areas in the left ventricle to measure the thermal conductivity, volumetric heat capacity, and thermal diffusivity. All the measured areas were excised for histological analysis. An in silico model of radiofrequency catheter ablation was then built to evaluate the impact of the thermal parameters obtained. Stiffness, electrical properties, and vascularization were also included to simulate realistic healthy and infarcted myocardium according to previously published data. RESULTS More than one-half of the area of the infarcted samples was composed of collagen. No significant differences were found between the thermal properties of infarcted and healthy tissue. The RF lesion depths obtained from the computational model did not have any clinically relevant differences (<0.4 mm in depth) between the infarcted and healthy tissue., Funding was provided by the Spanigh Ministerior de Ciencia e Innovación (PID2022-136273OB-C31), Agencia Estatal de Investigación (PID2022-136273OA-C33), Fondo Europeo de Desarrollo Regional (RYC2022-036965-I) and Center for Biomedical Research Network on Cardiovascular Diseases (CIBERCV) (CB16/11/00261).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Thermal side effects during pulsed field ablation: an analysis using computer modelling

  • Mercado Montoya, Marcela
  • Gomez Bustamante, Tatiana
  • Mickelsen, Steven R.
  • Kulstad, Erik
  • Overzet, Lawrence J.
  • González-Suárez, Ana|||0000-0002-1813-4176
[EN] Aims: Pulsed field ablation (PFA) is described as non-thermal, but data from oncology and cardiology show thermal effects occur. The specific waveform parameters influencing thermal energy development during PFA are unclear. The aim of this study is to numerically evaluate the thermal effects of PFA on myocardial and oesophageal tissue at various peak voltage conditions. Methods and results: A three-dimensional computer model of the left atrium quantified thermal effects from PFA at peak voltages of 1, 1.5, and 2 kV. Energy was applied using a bipolar configuration with far-field and symmetry boundaries set as electrically insulating. A monophasic waveform with a 100 ¿s pulse width and a 1 s gap between pulses was applied for a total of 50 pulses, mimicking clinical conditions. Minimal temperature rise in the oesophagus was observed with 1 kV pulses (214.5 J). At 1.5 and 2 kV (570.3 and 1.23 kJ), temperatures reached 46.3°C and >62°C, respectively, after a single pulse train. These findings suggest that repeated applications could lead to even higher temperatures, especially if good tissue contact is obtained. These results align with data from other medical fields using pulsed field treatments. Conclusion: Thermal effects from PFA depend on the total energy deposited, with peak voltage being a significant factor. Current commercially available PFA systems have the potential to induce collateral thermal injury with repeated applications of pulsed field energy. This highlights the need for careful monitoring and adjustment of PFA parameters in clinical settings., This study was funded by the Spanish Ministerio de Ciencia e Innovacion, Agencia Estatal de Investigacion, Fondo Europeo de Desarrollo Regional (grants PID2022-136273OA-C33 funded by MICIU/AEI/10.13039/ 501100011033 and by ERDF/EU and the RYC2022-036965-I funded by MICIU/AEI/10.13039/501100011033 and ESF+) and the National Heart, Lung, And Blood Institute of the National Institutes of Health under award number R44HL158375 (the content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Computational Assessment of Electrical and Thermal Effects of Epicardial Pulsed Field Ablation Adjacent to Stented Arteries

  • Estevez-Laborí, Francisco
  • Izquierdo, Maite
  • Coffey, Ken
  • O Brien, Barry
  • González-Suárez, Ana|||0000-0002-1813-4176
[EN] Background: Current ablation strategies for the treatment of cardiac arrhythmias remain suboptimal. Treating cardiac arrhythmias using epicardial pulsed field ablation (PFA) selectively targets ganglionated plexi (GPs) within epicardial fat, offering a promising alternative to thermal ablation. Previous computational studies lacked physiological realism, excluding catheter geometry, fluid flow and post-PFA thermal latency. This study aimed to develop a realistic 3D epicardial PFA model integrating a clinical catheter, clinical PFA parameters and a sequentially coupled electro-thermal-fluid dynamics model, including thermal latency, to assess electrical and thermal collateral effects near stented coronary arteries. Methods: The model included epicardial fat, myocardium, blood, and the left circumflex artery containing a metallic stent positioned 0.25 mm beneath the catheter electrodes. Pulses of 1000, 2000, and 2500 V (60 pulses × 100 µs, 1 Hz) were simulated to analyze electric field distribution, PFA-induced lesion volume, temperature evolution, and Arrhenius-based thermal damage, including a 90 s post-pulse period to account for thermal latency. The PFA-threshold of 1000 V/cm was considered. Results: The artery reduced PFA-induced lesion size mainly by occupying fat tissue volume, while the stent shielded the lumen without altering fat lesion volume. The presence of a stent produced localized electric field enhancement at the arterial wall, with up to 3.83% of the arterial wall volume affected by PFA in the worst-case configuration. At clinical settings (1000 V), temperature remained below 40 °C and no collateral damage occurred. Voltages > 2000 V increased arterial wall heating, with thermal damage expanding up to five-fold during latency in the epicardial fat. Myocardium remained unaffected in all cases. Conclusions: The computational model developed in this study indicates that clinically relevant PFA parameters (1000 V) produce localized electric field enhancement at the stent¿artery interface, resulting in limited collateral electrical effects in the arterial wall, while avoiding collateral thermal effects and preserving the myocardium. However, the use of higher pulse voltages can lead to delayed thermal damage within the epicardial fat., This research was funded by the Spanish Ministerio de Ciencia e Innovación, Agencia Estatal de Investigación, Fondo Europeo de Desarrollo Regional (Grants PID2022-136273OA-C33, PID2022-136273OB-C31, and RYC2022-036965-I funded by MICIU/AEI/10.13039/501100011033/ERDF/EU and by MICIU/AEI/10.13039/501100011033/ESF+).