Pasar al contenido principal

ECODISPOSITIVOS ANALITICOS BASADOS EN TECNOLOGIAS 'LAB-ON-PAPER' PARA LA DETECCION DE CONTAMINANTES AMBIENTALES Y ALIMENTARIOS

PID2022-136337OB-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2022
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD DE VIGO

Resultados relacionados

Resultados totales (Incluyendo duplicados): 9
Encontrada(s) 1 página(s)

Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

In situ formation of a Fe3O4@HgS nanocomposite for green preconcentration of Hg followed by detection with a direct mercury analyzer

  • González Fernández, Aida
  • De La Calle Gonzalez, Inmaculada
  • Romero Rivas, Vanesa
  • Lavilla Beltrán, Maria Isela
  • Bendicho Hernández, Jose Carlos
A novel method with a high greenness profile for the selective preconcentration and detection of Hg at ultratrace levels that involves magnetic nanoparticles has been developed. The ultrasonic decomposition of l-cysteine generated sulphide anion, which acts as a precursor for the formation of Fe3O4@HgS structures resulting in the efficient trapping of Hg(II) onto magnetite. Ultrasonic energy can be considered as green energy and l-cysteine is more environmentally friendly reagent than other sulphide precursors such as sodium sulphide. The magnetic sorbent allowed an easy phase separation using a magnet, thus avoiding centrifugation or filtration steps. A direct mercury analyzer allowed the direct and sensitive determination of the Hg collected onto the magnetic phase. A preconcentration factor of up to 91 and a limit of detection of 0.04 μg L−1 Hg can be achieved using a sample volume of 20 mL. Three reference materials were analyzed after application of the developed preconcentration method obtaining recoveries in the range 96–100 %. Additionally, water samples, including mineral water, tap water, seawater, fountain water and river water, were spiked at two levels of concentration, 5 and 10 μg L−1, recoveries being in the range of 91–110 %, Agencia Estatal de Investigación | Ref. PID2022-136337OB-I00, Agencia Estatal de Investigación | Ref. RTI2018-093697-B-I00, Universidade de Vigo/CISUG
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

Silver nanocluster-based colorimetric/fluorimetric dual-mode sensor for the detection of bromide and sulfite in waters and wastewaters

  • Villarino García, Nerea
  • Lavilla Beltran, Maria Isela
  • Pena Pereira, Francisco Javier
  • Bendicho Hernandez, Jose Carlos
In this work, the development of a fluorimetric/colorimetric dual-mode nanosensor for the determination of sulfite and fluorimetric determination of bromide involving silver nanoclusters (AgNCs) is reported. SO2 and Br2 were found to significantly modify the optical properties of AgNCs. Particularly, both volatiles weakened the fluorescence of AgNCs, whereas a color change from nearly colorless to yellowish/brown occurred upon exposure of AgNCs to SO2. Accordingly, three smartphone-based optical assays were devised for sulfite and bromide determination, involving in situ volatile generation and enrichment/trapping of the selectively formed volatiles by AgNCs confined in a droplet and exposed to the headspace above the sample. A hydrophobized cellulose substrate acting as drop holder enabled integrating both the enrichment and the subsequent smartphone-based optical detection in a straightforward manner. Smartphone-based digitization of the enriched AgNCs microdrops and subsequent image processing using a smartphone and its integrated App, respectively, were used for quantitative purposes. Under optimal conditions, limits of detection (LODs) of 1.1 μM and 1.5 μM were achieved for the fluorimetric determination of sulfite and bromide, respectively, whereas sulfite was alternatively determined by colorimetric readout, yielding a LOD of 37.0 μM. The repeatability, expressed as relative standard deviation, was found to be in the range of 5.1–5.9 % in all cases (N = 8). The applicability of the method was demonstrated in aqueous samples of increasing complexity, with recoveries in the range 91–109 %. In addition, the responsiveness of AgNCs to SO2 and Br2 rendered them suitable for the monitoring of bromide and sulfite in increasingly relevant advanced reduction processes such as the UV/sulfite system, as demonstrated in this work., Agencia Estatal de Investigación | Ref. PID2022-136337OB-I00, Universidade de Vigo/CISUG
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

A 2D microfluidic paper sensor for mercury speciation in fish based on the peroxidase-mimicking activity of l-cysteine-functionalized iron oxide nanoparticles

  • Abalde Pujales, Alberto
  • Villarino García, Nerea
  • Pena Pereira, Francisco Javier
  • Romero Rivas, Vanesa
A novel, field-deployable colorimetric assay based on a two-dimensional microfluidic paper-based analytical device (2D μPAD) was developed for on-site mercury speciation in fish samples. The device integrates L-Cysteine (L-Cys) functionalized iron oxide nanoparticles (Fe3O4@L-Cys NPs) that act as mercury-responsive nanozyme. In the presence of mercury species, L-Cys could be displaced from the Fe3O4 NPs' surface by a stronger L-Cys-Hg-LCys coordination complex. The uncoated Fe3O4 NPs reactivates the peroxidase-like activity of the nanozyme catalyzing the oxidation of 3,3′,5,5′-tetramethylbenzidine (TMB) in the presence of hydrogen peroxide into bluecolored TMBox for quantitative readout. Speciation was performed directly on the 2D μPAD using a selective ethylenediaminetetraacetic acid (EDTA) masking step. The pre-deposited EDTA in the sample addition zone complexes inorganic mercury (Hg2+), preventing its interaction with the NPs, allowing the colorimetric signal to reflect only methylmercury (MeHg+). Under optimal conditions, the 2D μPAD enabled to monitor total mercury in a linear range of 25 to 200 μg L− 1 and MeHg+ in the range of 12.5 – 200 μg L− 1 . The developed assay showed limits of detection as low as 7.3 μg L− 1 and 3.6 μg L− 1 for total mercury and MeHg+, respectively, with a repeatability lower than 3.7 % (N = 5) in all cases. The developed 2D μPAD was applied to determine total mercury and MeHg+ in fish samples, yielding results consistent with the centralized Direct Mercury Analyzer method. The method was further validated using two certified reference materials, BCR-464 (tuna muscle) and DOLT-4 (dogfish liver), with measured values in good agreement with certified concentrations (t-test; p < 0.05)., Agencia Estatal de Investigación | Ref. PID2022-136337OB-I00, Universidade de Vigo/CISUG
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

A perspective on current and future metric tools

  • Pena Pereira, Francisco Javier
  • Benedé, Juan L.
Assessment tools have attracted immense interest in the analytical field in recent years, and remarkable developments have been described toward increasing levels of refinement. However, substantial improvements of metric tools are still needed to obtain highly relevant information about analytical systems in an efficient manner while maintaining or increasing their user friendliness, minimizing their potential subjectivity, and ensuring a high reliability and comparability. The present perspective identifies areas of improvement of currently available metric tools and highlights potential initiatives to be tackled toward advanced metric tools, Agencia Estatal de Investigación | Ref. PID2022-136337OB-I00, Agencia Estatal de Investigación | Ref. RED-2022-134079-T, Universidade de Vigo/CISUG
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

Colorimetric plasmonic sensing of formaldehyde by in situ formation of core-shell bimetallic gold–silver nanoparticles in liquid films

  • Villarino García, Nerea
  • Lavilla Beltrán, Maria Isela
  • Pena Pereira, Francisco Javier
  • Bendicho Hernández, Jose Carlos
Background: Plasmonic sensing approaches involving in-drop enrichment/sensing of volatiles have significantly improved the sensitivity and selectivity of noble metal nanoparticle (NP)-based analytical methods. Colloidal solutions act in these approaches both as acceptor phases and as recognizing elements for optical detection. However, the reduced surface area-to-volume (SA/V) ratio associated to the spherical configuration of NPscontaining microdrops hinders the mass transfer in the acceptor phase and thus results in suboptimal analytical performance. In this sense, the assessment of alternative geometries that could potentially enhance the mass transfer while ensuring ease of operation would be highly desirable. Results: The present work evaluates the suitability of liquid films of plasmonic NPs for enrichment/colorimetric sensing purposes. For this, the circular section of affordable stainless steel safety pins is employed as holder of stable microvolume films with enhanced SA/V ratio. As a proof of concept, liquid films of spherical gold NPs containing Tollens’ reagent have been evaluated as acceptor phases for formaldehyde enrichment and sensing via in situ formation of core-shell bimetallic gold-silver nanoparticles. The performance of the proposed approach has been compared with that of alternative LPME approaches, showing 2.2–3.0-fold higher enrichment factors and improved sensitivity. The method yielded a limit of detection of 56.7 nM and a repeatability of 6.8 % (N = 8) when a portable cuvetteless microvolume UV–vis spectrophotometric system was used, and has been successfully applied to the determination of formaldehyde in different waters and textile samples. Significance: The present study represents the first report that evaluates planar liquid films for simultaneous enrichment and optical sensing, and provides an effective and straightforward way to obtain liquid film-like configurations of variable volumes of acceptor phase for improved mass transfer. The proposed approach shows substantial potential for the development of sensors and nanosensors with enhanced sensitivity., Agencia Estatal de Investigación | Ref. PID2022-136337OB-I00
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

A 3D microfluidic paper-based analytical device with smartphone-based colorimetric readout for phosphate sensing

  • Graña Dosantos, José Manuel
  • Pena Pereira, Francisco Javier
  • Bendicho Hernández, Jose Carlos
  • De La Calle Gonzalez, Inmaculada
In this work, a 3D microfluidic paper-based analytical device (3D-µPAD) was developed for the smartphone-based colorimetric determination of phosphate in environmental samples. The assay relied on the formation of a blue-colored product (molybdenum blue) in the detection area of the 3D-µPAD upon reduction of the heteropolyacid H3PMo12O40 formed in the presence of phosphate. A number of experimental parameters were optimized, including geometric aspects of 3D-µPADs, digitization and image processing conditions, the amount of chemicals deposited in specific areas of the 3D-µPAD, and the reaction time. In addition, the stability of the device was evaluated at three different storage temperatures. Under optimal conditions, the working range was found to be from 4 to 25 mg P/L (12–77 mg PO4−3/L). The limits of detection (LOD) and quantification (LOQ) were 0.015 mg P/L and 0.05 mg P/L, respectively. The repeatability and intermediate precision of a 5 mg P/L standard were 4.8% and 7.1%, respectively. The proposed colorimetric assay has been successfully applied to phosphorous determination in various waters, soils, and sediments, obtaining recoveries in the range of 94 to 107%. The ready-to-use 3D-µPAD showed a greener profile than the standard method for phosphate determination, being affordable, easy-to-use, and suitable for citizen science applications., Agencia Estatal de Investigación | Ref. PID2022-136337OB-I00
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

Multiplexed headspace paper-based analytical devices modified with silver nanoclusters for smartphone-based luminescent determination of inorganic preservatives in food samples

  • Villarino García, Nerea
  • Lavilla Beltrán, Maria Isela
  • Pena Pereira, Francisco Javier
  • Bendicho Hernández, Jose Carlos
Background: Reliable determination of inorganic chemical preservatives is essential for ensuring food safety, due to the health concerns associated to these compounds when present at excessive levels. Nitrite and sulfite, two inorganic preservatives widely used in the food industry, increasingly demand miniaturized alternatives to conventional analytical methods. In this regard, luminescent nanosensors are of particular relevance because of their superior sensitivity. However, further improvements are still needed to enhance their selectivity and multiplexing capability, while ensuring their applicability in the analysis of complex matrices. Results: The present study reports on the development of two paper-based analytical devices (PADs) involving luminescent silver nanoclusters (AgNCs) as sensing nanoreceptors for the simultaneous smartphone-assisted detection of sulfite and nitrite. The assays rely on the highly selective recognition of nitrogen oxides and sulfur dioxide by AgNCs protected with poly(methacrylate) and polyethylenimine, respectively, separately immobilized in the detection areas of PADs. Thus, in this work, AgNCs-containing PADs have been devised for the simultaneous determination of sulfite and nitrite involving in situ formation of the volatile derivatives and their selective trapping/interaction with the corresponding AgNCs nanoreceptors, leading to luminescence quenching. Two different configurations have been evaluated for the development of PAD-based nanosensors, namely in-vial PAD-based headspace microextraction (HS-PAD) and headspace 3D origami microfluidic PAD (HS-μPAD). Under optimal conditions, the developed assays showed limits of detection as low as 0.29 μM and 0.23 μM for sulfite and nitrite, respectively, for the HS-PAD approach, and 1.9 μM and 3.2 μM for the HS-μPAD configuration, with a repeatability expressed as relative standard deviation lower than 7.3 % (N = 8) in all cases. In addition, the developed PAD-based nanosensors were applied to the analysis of food samples, the results obtained showing excellent agreement with those obtained with reference methods. Significance: This article reports, for the first time, on the assessment of AgNCs with different responsiveness as luminescent nanoprobes for the development of multiplexed paper-based nanosensors with headspace sampling. The proposed assays enable decentralized, affordable and straightforward detection of sulfite and nitrite, being complementary in terms of sample consumption and sensitivity, and represent advantageous alternatives for quality control and safety monitoring in the food industry., Agencia Estatal de Investigación | Ref. PID2022-136337OB-I00, Universidade de Vigo/CISUG
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Tesis doctoral (DoctoralThesis)

Development of innovative sensing approaches based on natural compounds using cellulose substrates combined with optical detection, Desarrollo de estrategias innovadoras de detección basadas en compuestos naturales utilizando sustratos de celulosa combinados con detección óptica, Desenvolvemento de estratexias innovadoras de detección baseadas en compostos naturais empregando substratos de celulosa combinados con detección óptica

  • Placer Vidal, Lorena
The analytical methodologies used for the determination of contaminants commonly require advanced analytical instrumentation, which hinders their application in on-site analysis. The development of miniaturized instrumental systems allows decentralized analysis, although it is necessary to develop preconcentration and selective detection strategies that allow the unequivocal determination of compounds of interest at low concentration levels. In addition, the combination of widely deployed electronic devices, such as smartphones, tablets, scanners or webcams, with image processing software offers new opportunities for chemical analysis. However, these systems generally show low sensitivity and selectivity. Therefore, it would be highly desirable to develop sensitive and selective methods involving portable detection systems and, especially, high-implementation electronic devices for on-site quantitative analysis with minimal consumption of chemical reagents. In this regard, a number of optically active molecular compounds derived from natural compounds, are highly promising for non-instrumental optical detection. The present PhD research project is focused on the development of new optical sensors for the monitoring of various environmental pollutants. The general objectives are the design of new miniaturized analytical systems for the ultrasensitive detection of analytes of environmental interest. Implementation of optically active materials in micro-separation systems. Preliminary evaluation of the potential of these systems. Use of miniaturized instrumental optical techniques (UV-vis spectrophotometry and fluorospectrometry). Combination of miniaturized analytical systems with digitization and image processing systems for non-conventional optical detection. Study of the recognition mechanism of analytes of interest by means of instrumental characterization techniques and computational studies. Development of novel, rapid, sensitive and selective analytical methodologies with potential for on-site analysis., Las metodologías analíticas empleadas para la determinación de contaminantes requieren, comúnmente, instrumentación analítica avanzada, lo cual dificulta enormemente su aplicación en análisis on site. El desarrollo de sistemas instrumentales miniaturizados permite realizar análisis descentralizados, si bien es necesario desarrollar estrategias de preconcentración y detección selectiva que permitan efectuar la determinación inequívoca de compuestos de interés a bajos niveles de concentración. Además, la combinación de dispositivos electrónicos de amplia implantación, tales como teléfonos inteligentes, tabletas, escáneres o webcams, con programas informáticos de procesamiento de imágenes ofrece nuevas oportunidades para efectuar análisis químicos. Sin embargo, estos sistemas muestran generalmente una baja sensibilidad y selectividad. Sería altamente deseable, por tanto, el desarrollo de métodos sensibles y selectivos que involucren sistemas de detección portátiles y, especialmente, dispositivos electrónicos de alta implantación para el análisis cuantitativo on site de contaminantes con un consumo mínimo de reactivos químicos. En este sentido, una serie de materiales ópticamente activos, tales como compuestos moleculares derivados de compuestos naturales, son altamente prometedores para la detección óptica no instrumental. El presente proyecto de tesis está enfocado al desarrollo de nuevos sensores ópticos para el control de diversos contaminantes medioambientales. Los objetivos generales son el diseño de nuevos sistemas analíticos miniaturizados para la detección ultrasensible de analitos de interés medioambiental. Implementación de materiales ópticamente activos en sistemas de microseparación. Evaluación preliminar del potencial de dichos sistemas. Empleo de técnicas ópticas instrumentales (espectrofotometría y fluorospectrometría) de microvolúmenes. Combinación de sistemas analíticos miniaturizados con sistemas de digitalización y procesamiento de imágenes para detección óptica no convencional. Estudio del mecanismo de reconocimiento de analitos de interés mediante técnicas de caracterización instrumentales y estudios computacionales. Desarrollo de metodologías analíticas novedosas, rápidas, sensibles y selectivas con potencial de análisis on site., As metodoloxías analíticas empregadas para a determinación de contaminantes requiren, comunmente, instrumentación analítica avanzada, o cal dificulta enormemente a súa aplicación en análises on site. O desenvolvemento de sistemas instrumentais miniaturizados permite realizar análises descentralizados, se ben é necesario desenvolver estratexias de preconcentración e detección selectiva que permitan efectuar a determinación inequívoca de compostos de interese a baixos niveis de concentración. Ademais, a combinación de dispositivos electrónicos de ampla implantación, tales como teléfonos intelixentes, tabletas, escáneres ou webcams, con programas informáticos de procesamento de imaxes ofrece novas oportunidades para efectuar análises químicos. Sen embargo, estes sistemas mostran xeralmente unha baixa sensibilidade e selectividade. Sería altamente desexable, polo tanto, o desenvolvemento de métodos sensibles e selectivos que involucren sistemas de detección portátiles e, especialmente, dispositivos electrónicos de alta implementación para o análise cuantitativo on site de contaminantes cun consumo mínimo de reactivos químicos. Neste sentido, unha serie de materiais ópticamente activos, tales como compostos moleculares derivados de compostos naturais, son altamente prometedores para a detección óptica non instrumental. O presente proxecto de tese está enfocado ó desenvolvemento de novos sensores ópticos para o control de diversos contaminantes medioambientais. Os obxectivos xerais son o deseño de novos sistemas analíticos miniaturizados para a detección ultrasensible de analitos de interese medioambiental. Implementación de materiais ópticamente activos en sistemas de microseparación. Avaliación preliminar do potencial de ditos sistemas. Emprego de técnicas ópticas instrumentais (espectrofotometría e fluorospectrometría) de microvolumes. Combinación de sistemas analíticos miniaturizados con sistemas de dixitalización e procesamento de imaxes para detección óptica non convencional. Estudo do mecanismo de recoñecemento de analitos de interese mediante técnicas de caracterización instrumentais e estudos computacionales. Desenvolvemento de metodoloxías analíticas novedosas, rápidas, sensibles e selectivas con potencial de análisis on site., Agencia Estatal de Investigación | Ref. RTI2018-093697-B-I00, Agencia Estatal de Investigación | Ref. PID2022-136337OB-I00
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

A 3D-microfluidic paper-based analytical device for the kinetic-catalytic colorimetric determination of vanadium with smartphone-based readout

  • Treviño, Estefanía
  • Villarino García, Nerea
  • Lavilla Beltrán, Maria Isela
  • Bendicho Hernández, Jose Carlos
  • Pena Pereira, Francisco Javier
Metal ion detection at trace levels remains challenging for paper-based analytical devices, as they often require preconcentration steps to reach low-ppb detection limits due to their limited sensitivity. This constraint reduces the overall simplicity and portability of paper-based devices, narrowing their suitability for truly filed-deployable analysis. A colorimetric kinetic-catalytic method in a three-dimensional origami microfluidic paper-based analytical device (3D-μPAD) is reported herein for the sensitive determination of vanadium. The method relies on the catalytic activity of vanadium in the oxidation of gallic acid by bromate in acidic media with formation of a colored product in the detection areas of the 3D-μPAD and smartphone-based readout. The proposed method was successfully employed using two different calibration modes (fixed-time and initial-rate), yielding limits of detection and quantification in the range 3.1-3.6 μg/L and 10.3-12.0 μg/L, respectively, with a repeatability and intermediate precision lower than 7.2% and 7.5%, respectively (expressed as relative standard deviation). The fixed-time and initial-rate methods showed sensitivities of 0.18 L/μg and 4.1·10−4 L/μg·s, respectively, working ranges up to 500 μg/L, and a sample throughput in the range of 48-96 h−1. The method was validated against six certified reference materials of diverse matrices (seawater, sediment, soil and industrial sludge), showing good agreement with the certified values at the 95% confidence level using both the fixed-time and the initial-rate methods (t-test; p < 0.05). The implementation of kinetic-catalytic reactions in μPADs is expected to enable further advances toward sensitive detection of metals., Agencia Estatal de Investigación | Ref. PID2022-136337OB-I00, Universidade de Vigo/CISUG