BUSQUEDA DE LOS LIMITES DEL MODELO ESTANDAR Y DESARROLLO DE NUEVA INSTRUMENTACION PARA EL UPGRADE-II DE LHCB

PID2022-140591NB-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2022
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDADE DE SANTIAGO DE COMPOSTELA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 1
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Performance of a CeBr3 scintillator coupled to a photomultiplier tube with an active voltage divider under high bremsstrahlung fluences

  • García Rivas, I.
  • Fernández Prieto, A.
  • Vázquez Regueiro, P.
  • García Fernández, D.
  • Kögler, T.
  • Römer, K.
  • Hueso-González, F.
Proton therapy lacks a standard method to verify the proton range during the treatments in the clinical routine. In this context, the monitoring of prompt γ-rays in a coaxial geometry using a compact detector based on a CeBr3 scintillator coupled to a commercial photomultiplier tube (PMT) could lead to the identification of proton range deviations. Such detection system could be easily integrated in every treatment room. Although measuring in this geometry profits from an advantageous solid angle, the detector is also exposed to an extreme γ-ray rate, of up to 10 Mcps. In this work, we present the first experimental performance evaluation for the proposed detector by irradiating it at very high bremsstrahlung rates at the γELBE facility. Using a customized active voltage divider to supply voltage to the PMT, the detection system was able to sustain a photon rate higher than 12 Mcps without dead time while keeping gain drifts below 15 % in the best configuration, and to achieve a sub-nanosecond time resolution. © 2025 The Author(s), This work has been supported by Xunta de Galicia, Spain, under the Industrial Doctorates Program 2022 (Galician Innovation Agency) and under grant number ED431C/3, by Ministerio de Ciencia e Innovación, Spain, under project PID2022-140591NB-I00 and by Generalitat Valenciana, Spain, (Conselleria de Educación, Investigación, Cultura y Deporte) under grant number CDEIGENT/2019/011. This work has also received funds from the Particle Therapy Cooperative Group (PTCOG) under project funding 2024 and from the European Union’s 2020 research and innovation program under grant 101008126, corresponding to RADNEXT project. IGFAE is supported by the María de Maeztu grant CEX2023-001318-M and IFIC by the Severo Ochoa Center of Excellence grant CEX2023-001292-S, both funded by MCIU/AEI., Peer reviewed