Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 15
Encontrada(s) 1 página(s)

Docta Complutense
Publicación Artículo científico (JournalArticle)

Proton irradiation effects on silicon heterojunction solar cells with MoOx selective contacts

  • Duarte Cano, Sebastián
  • Pérez Zenteno, Francisco José
  • Caudevilla Gutiérrez, Daniel
  • Olea Ariza, Javier
  • San Andrés Serrano, Enrique
  • Prado Millán, Álvaro Del
  • Benítez Fernández, Rafael
  • García Hemme, Eric
  • Rezaei, Mohammadreza
  • Clemente Barreira, Juan Antonio
  • Algaidy, S.
  • Torres, I.
  • Barrio, R.
  • Ros, E.
  • Puigdollers, J.
  • Ortega, P.
  • Voz, C.
  • García Hernansanz, Rodrigo
In this study, we investigate the effects of proton irradiation on silicon-based heterojunction and molybdenum oxide (MoOx) selective contact solar cells. The main idea is to study their potential application in small satellites for measurement and monitoring. The irradiation dose simulates the aggressive environment found in Low Earth Orbit (LEO), where many satellites currently use Group III-VI (GaInP/GaAs/Ge) solar cells due to their superior efficiency, albeit at a higher cost. The experimental approach includes fabrication, irradiation, and characterization methods. Our results show a decrease in fill factor (F.F.) and overall efficiency after irradiation, mainly caused by a decrease in shunt resistance and an increase in series resistance. In addition, open-circuit voltage (Voc) and short-circuit current (Isc) may be affected by displacement damage defects caused by the irradiation process within the active region or by the formation of new point defects.
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Tesis doctoral (DoctoralThesis)

Hardening techniques for mitigating radiation effects in high-end multicore COTS processor-based systems

  • Avilés Delgado, Pablo Miguel
Mención Internacional en el título de doctor, La radiación representa un importante desafío en el empleo de componentes electrónicos en misiones espaciales debido a que los niveles son más elevados que en el ámbito terrestre. Como consecuencia, los componentes pueden sufrir fallos y degradarse, lo cual es especialmente crítico en este ámbito donde la fiabilidad es fundamental. La exposición continua a la radiación puede causar efectos acumulativos y permanentes, como la Dosis Ionizante Total (Total Ionizing Dose, TID) y el Daño por Desplazamiento (Displacement Damage, DD), pero también puede provocar fallos como consecuencia del impacto de una sola partícula ionizante, denominados Efectos de Evento Único (Single-Event Effect, SEE). Estos últimos pueden tener un carácter transitorio (soft errors) o permanente (hard errors). Los soft errors son fallos no destructivos, es decir, no dañan físicamente el circuito, pero pueden alterar su funcionamiento y se están volviendo cada vez más comunes. Los soft errors inducidos por radiación fueron considerados en un inicio como un mecanismo de fallo relativamente raro que causaba anomalías en equipos satelitales y la industria espacial, pero en la actualidad han emergido también como un desafío en el uso de sistemas electrónicos que desempeñan funciones críticas de seguridad en la aviación e incluso en aplicaciones terrestres. En el caso de las aplicaciones espaciales, se utilizan componentes electrónicos que son críticos para el control, la comunicación, la navegación, la adquisición de datos y otros fines. Estos pueden incluir microprocesadores, sensores, sistemas de comunicación, memorias, etc. Los sistemas basados en procesadores desempeñan un papel fundamental, ya que permiten realizar tareas de diferente complejidad, y posibilitan el procesamiento a bordo con el de fin reducir el envío de datos a las estaciones terrestres o disminuir las necesidades de memoria de almacenamiento. La miniaturización de las tecnologías de silicio, la mayor densidad de integración, el uso de voltajes de suministro de energía reducidos, el empleo de márgenes de ruido disminuidos y de frecuencias de funcionamiento elevadas han propiciado que los sistemas electrónicos, incluidos los sistemas basados en microprocesadores, sean más susceptibles a soft errors inducidos por radiación. Existen componentes electrónicos diseñados específicamente para ambientes de radiación denominados rad-hard (del inglés radiation-hardened). Los procesadores rad-hard se han utilizado durante años en misiones espaciales, pero su precio es elevado y sus capacidades computacionales están muy por debajo de las que ofrecen los microprocesadores comerciales de uso en aplicaciones terrestres. En los últimos años se ha incrementado el interés por el sector espacial, no solo por agencias y organizaciones gubernamentales, sino también por empresas privadas. La era del Nuevo Espacio (New Space en inglés), que representa este creciente interés de la industria privada en el sector espacial, ha marcado una tendencia en el uso de componentes electrónicos comerciales conocidos comúnmente como COTS (del inglés Commercial Off-The-Shelf) en lugar de los componentes rad-hard. Los componentes COTS son más asequibles y están más ampliamente disponibles en comparación con los componentes rad-hard. Además, permiten plazos de preparación y lanzamiento de las misiones mucho menores, su precio es menor y sus prestaciones son mayores. El uso de procesadores COTS y de otros dispositivos electrónicos integrados que combinan múltiples componentes hardware en un solo chip, tales como los sistemas en un chip (System-on-Chip, SoC) y los sistemas multiprocesadores en un chip Multiprocessor System-on-Chip, MPSoC) se ha incrementado, lo cual ha permitido abaratar los costes de las misiones e incrementar las capacidades de cómputo de los sistemas a bordo. Tanto la Administración Nacional de Aeronáutica y del Espacio de los Estados Unidos de América (National Aeronautics and Space Administration, NASA) como la Agencia Espacial Europea (European Space Agency, ESA) han utilizado estos dispositivos en algunas misiones recientes, pues en caso contrario hubiera sido imposible cumplir con las especificaciones de prestaciones que requerían dichas misiones. Sin embargo, el uso de sistemas COTS basados en microprocesadores en el ámbito de las aplicaciones espaciales plantea desafíos en términos de fiabilidad y resistencia a la radiación, dado que no están fabricados para operar en esos ambientes. Para abordar estos desafíos, se han desarrollado, y se continúan desarrollando, técnicas de endurecimiento y tolerancia a fallos para hacer a los procesadores COTS robustos ante los efectos de la radiación. De hecho, existen varios estándares y guías para la prueba de dispositivos electrónicos, incluyendo sistemas basados en microprocesadores, en entornos adversos. Estos estándares y guías, desarrollados por varias agencias y organizaciones incluyendo la NASA y la ESA, establecen las pautas y los requisitos a tener en cuenta en las pruebas de radiación de componentes electrónicos considerando diversos tipos de partículas. En esta tesis se han diseñado dos técnicas de endurecimiento denominadas Macrosynchronized Lockstep (MSLS) y Supervised Triple Macrosynchronized Lockstep (STMLS). Ambas propuestas constituyen aportaciones originales de esta tesis y tienen como objetivo incrementar la resistencia de sistemas COTS basados en procesadores multinúcleo de alta gama para cumplir con los requisitos de fiabilidad en condiciones de radiación. Las técnicas implementan diversos mecanismos de corrección y recuperación de errores y se basan en el empleo de núcleos redundantes para ofrecer fiabilidad. En la investigación se han empleado dispositivos avanzados SoC y MPSoC como vehículos de prueba para evaluar y validar los enfoques propuestos. Los dispositivos seleccionados tienen un impacto significativo en la industria de la electrónica comercial y son relevantes también en el sector espacial. La efectividad de las estrategias de mitigación de errores propuestas en esta tesis ha sido evaluada mediante metodologías establecidas para calificar componentes electrónicos destinados a entornos de radiación. Se han realizado campañas de inyección de fallos, y campañas de radiación en diversas instalaciones europeas utilizando diferentes tipos de partículas y cumpliendo con los estándares establecidos. Los resultados demuestran la efectividad de MSLS y STMLS en la corrección de errores y en la recuperación del sistema ante fallos no corregibles. Las técnicas de endurecimiento diseñadas en el marco de esta tesis poseen una amplia aplicabilidad en varios dominios de alta fiabilidad, incluyendo el campo de las aplicaciones espaciales., Radiation poses a significant challenge in using electronic components in space missions, as they are exposed to much higher radiation levels than those found in terrestrial environments. This can lead to component failures and degradation, which is particularly critical in the space domain, where reliability is crucial. Continuous radiation exposure can result in cumulative and permanent effects, such as Total Ionizing Dose (TID) and Displacement Damage (DD), but can also cause failures due to the impact of a single ionizing particle, known as Single-Event Effect (SEE). SEE can be transient (soft errors) or permanent (hard errors). Soft errors are non-destructive failures, meaning they do not physically damage the circuit but can alter its operation and are becoming increasingly common. Radiation-induced soft errors were initially considered a relatively rare failure mechanism causing anomalies in satellite equipment and the space industry, but today, they have also emerged as a challenge in using electronic systems that perform critical safety functions in aviation and even in terrestrial applications. In the case of space applications, electronic components are essential for control, communication, navigation, data acquisition, and other purposes. These may include microprocessors, sensors, communication systems, memories, etc. Processor-based systems play a fundamental role in allowing tasks of varying complexity to be performed and enabling onboard processing to reduce data transmission to ground stations or storage memory requirements. The miniaturization of silicon technologies, higher integration density, lower supply voltages, reduced noise margins, and high operating frequencies have made electronic systems, including processor-based systems, more susceptible to radiation-induced soft errors. There are electronic components specifically designed for use in radiation environments, known as rad-hard (radiation-hardened). Rad-hard processors have long been used in space missions, but they are expensive, and their computational capabilities are inferior to their commercial counterparts. In recent years, there has been increased interest in the space sector, not only from government agencies and organizations but also from private companies and enterprises. The New Space era has marked a trend towards using commercially available electronic components commonly known as Commercial Off-The-Shelf (COTS) instead of rad-hard components. COTS components are more readily available than rad-hard components. They also allow for much shorter mission preparation and launch schedules, are less expensive, and offer better performance. The use of COTS processors and other integrated electronic devices that combine multiple hardware components on a single chip, such as System-on-Chip (SoC) and Multiprocessor System-on-Chip (MPSoC), has increased, leading to mission cost saving and improved onboard computing capabilities. Both National Aeronautics and Space Administration of United States of America (NASA) and European Space Agency (ESA) have used these devices in some recent missions because it would be impossible to meet the performance specifications required for these missions otherwise. However, using COTS microprocessor-based systems in space applications presents challenges in terms of reliability and radiation resistance, as they are not designed to operate in such environments. To address these challenges, techniques for radiation hardening and fault tolerance have been and are being developed to make COTS processors robust against the effects of radiation. In fact, there are several standards and guidelines for testing electronic devices, including microprocessor-based systems, in harsh environments. These standards and guidelines establish the steps and requirements for radiation testing of electronic components, considering various types of particles. They have been developed by various agencies, associations, and organizations, including NASA and ESA, among others. Two hardening techniques have been developed in this thesis, namely Macrosynchronized Lockstep (MSLS) and Supervised Triple Macrosynchronized Lockstep (STMLS). Both proposals are original contributions of this thesis and aim to increase the resilience of high-end multicore COTS processor-based systems to meet reliability requirements in radiation environments. These techniques implement various error correction and recovery mechanisms and rely on the use of redundant processor cores to provide reliability. In this research, advanced SoC and MPSoC devices have been used as test vehicles to evaluate and validate the proposed approaches. The selected devices have a significant impact on the commercial electronics industry and are also relevant to the space sector. The effectiveness of the error mitigation strategies proposed in this thesis has been evaluated using established methodologies for the qualification of electronic components intended for radiation environments. Fault injection campaigns, and radiation campaigns in various European facilities with different types of particles and in compliance with international standards and guidelines have been conducted. The results demonstrate the effectiveness of MSLS and STMLS in correcting errors and recovering the system from uncorrectable errors. The hardening techniques designed within the scope of this thesis have broad applicability in various high-reliability domains, including the field of space applications., This work has been supported in part by the Spanish State Investigation Agency under projects PID2019-106455GB-C21 and PID2022-138696OB-C21, by the Community of Madrid under project no. 49.520608.9.18, by the European Union's Horizon 2020 Research and Innovation Program under Grant Agreement no. 101008126 in the framework of the EU project RADNEXT, and by Community of Madrid under Grant PEJD-2019-PRE/TIC-16327, co-financed by the European Social Fund through the Youth Employment Operational Program and the Youth Employment Initiative (YEI). The work resulting from collaboration with other departments or universities has also been made possible thanks to Grant PID2020-113785RB-100, Grant RTI2018-097045-B-C21 and Grant PID2020-113656RB-C21 funded by the Spanish State Investigation Agency, the Ramón y Cajal Grant RYC-2017-22101, as well as the Community of Madrid throughout the project MIMACUHSPACE-CM-UC3M (2022/00024/001)., Programa de Doctorado en Ingeniería Eléctrica, Electrónica y Automática por la Universidad Carlos III de Madrid, Presidenta: María Luisa López Vallejo.- Secretaria: Marta Portela García.- Vocal: Felipe Restrepo Calle
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Artículo científico (JournalArticle)

Evaluating Reduced Resolution Redundancy for Radiation Hardening in FPGA Designs

  • García Astudillo, Luis Ángel
  • Lindoso Muñoz, Almudena
  • Entrena Arrontes, Luis Alfonso
  • Martín González, Honorio
  • García Valderas, Mario
  • Martín-Holgado, Pedro
  • Morilla, Yolanda
Radiation hardening by design (RHBD) is traditionally performed using triple modular redundancy (TMR), a very effective technique that introduces high overheads in terms of resources and power. The reduced resolution redundancy (RRR) technique presented in this work is a new approximate error mitigation technique that uses redundant circuits with lower resolution to perform computations. In this work, we evaluate this technique under radiation using two different benchmarks implemented in field-programmable gate array (FPGA), namely, a fast Fourier transform (FFT) and an image processing algorithm for a near-infrared (NIR) detector. Experimental results from proton and neutron irradiation, and fault injection campaigns, show that the RRR hardening technique can effectively mitigate errors with reduced overheads., This work was supported in part by the Spanish Agencia Estatal de Investigacion (AEI) under Project PID2019-106455GB-C21 and Project AEI/10.13039/501100011033 and in part by the European Union's Horizon 2020 Research and Innovation Program through the Framework of the European Union (EU) Project RADiation facility Network for the EXploration of Effects for indusTry and research (RADNEXT) under Grant 101008126.
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Artículo científico (JournalArticle)

Hybrid Hardening Approach for a Fault-Tolerant RISC-V System-On-Chip

  • Santos, Douglas A.
  • Avilés Delgado, Pablo Miguel
  • Mattos, André M. P.
  • García Valderas, Mario
  • Entrena Arrontes, Luis
  • Lindoso Muñoz, Almudena
The New Space era has driven a wide array of applications in novel space missions with an increasing demand for processors with high computational capabilities while simultaneously maintaining low power consumption, flexibility, and reliability. Soft-core processors based on commercial off-the-shelf (COTS) technologies have emerged as a viable alternative that can meet these requirements but need to be hardened to operate in harsh environments. In this work, we propose and apply fault tolerance strategies based on software recovery using checkpoint and rollback operations to extend the capabilities of a hardened soft-core RISC-V-based system-on-chip. The proposed strategy relies on the fault awareness provided by the system-on-chip hardening to trigger the software recovery without the addition of dedicated structures or processor cores. Notably, we investigate the effectiveness of this multilayer hardening strategy, which combines software recoverability and hardware redundancy. For that, a neutron irradiation campaign was performed. The results show the effectiveness of the proposed approach, achieving 45.09% of effective software recovery operations with low overhead for performance and resource utilization., European Union’s Horizon 2020 Research and Innovation Program (Grant Number: 101008126) Region d’Occitanie and the École Doctorale I2S through the University of Montpellier (Grant Number: 20007368/ALDOCT- 000932) 10.13039/501100004837-Ministerio de Ciencia e Innovación (MCIN)/Agencia Estatal de Investigación (Grant Number: (AEI)/10.13039/501100011033) “European Regional Development Fund (ERDF) A way of making Europe” (Grant Number: PID2022-138696OB-C21)
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Tesis doctoral (DoctoralThesis)

Approximate hardening techniques for digital signal processing circuits against radiation-induced faults

  • García Astudillo, Luis Ángel
RESUMEN NO TÉCNICO. Se llama radiación al proceso por el cual una partícula o una onda es capaz de transmitir energía a través del espacio o un medio material. Si la energía transmitida es suficientemente alta, la radiación puede provocar que algunos electrones se desplacen de su posición, en un proceso llamado ionización. La radiación ionizante puede provocar problemas a los seres vivos, pero también a los diversos materiales que componen los sistemas eléctricos y electrónicos utilizados en entornos sujetos a radiación. Existen en La Tierra varios procesos que emiten radiación ionizante, como la obtención de energía en centrales nucleares o ciertos procedimientos médicos. Sin embargo, las fuentes de radiación más importantes se sitúan más allá de nuestra atmósfera y afectan fundamentalmente a sistemas aeroespaciales y vuelos de gran altitud. Debido a la radiación, los sistemas electrónicos que se exponen a cualquiera de estas fuentes sufren degradación en sus propiedades a lo largo del tiempo y pueden sufrir fallos catastróficos que acorten su vida útil. El envejecimiento de los componentes se produce por acumulación de carga eléctrica en el material, lo que se conoce como Dosis Ionizante Total (TID por sus siglas en inglés), o por distorsiones en el silicio sobre el que se fabrican los circuitos, lo que se conoce como Daño por Desplazamiento (DD). Una única partícula ionizante puede, sin embargo, provocar también diversos tipos de fallos transitorios o permanentes en los componentes de un circuito, generalmente por un cambio de estado en un elemento de memoria o fallos destructivos en un transistor. Los diferentes tipos de fallos producidos en circuitos por la acción de una única partícula ionizante se engloban en la categoría de Efectos de Evento Único (SEE por sus siglas en inglés). Para proteger los sistemas electrónicos frente a los efectos de la radiación se suele recurrir a un conjunto de técnicas que llamamos endurecimiento frente a radiación. Los procedimientos tradicionales de endurecimiento han consistido en la fabricación de componentes electrónicos mediante procesos especiales que les confieran una resistencia inherente frente a la TID, el DD y los SEE. A este conjunto de técnicas de endurecimiento se lo conoce como Endurecimiento frente a la Radiación Por Proceso (RHBP por sus siglas en inglés). Estos procedimientos suelen aumentar el coste de los componentes y empeorar su rendimiento con respecto a los componentes que usamos en nuestros sistemas electrónicos cotidianos. En oposición a las técnicas RHBP encontramos las técnicas de Endurecimiento frente a la Radiación Por Diseño (RHBD por sus siglas en inglés). Estas técnicas permiten detectar y tratar de corregir fallos producidos por la radiación introduciendo modificaciones en los circuitos. Estas modificaciones suelen aumentar la complejidad de los circuitos que se quiere endurecer, haciendo que consuman más energía, ocupen más espacio o funcionen a menor frecuencia, pero estas desventajas se pueden compensar con la disminución de los costes de fabricación y la mejora en las prestaciones que aportan los sistemas modernos. En un intento por reducir el coste de las misiones espaciales y mejorar sus capacidades, en los últimos años se trata de introducir un mayor número de Componentes Comerciales (COTS por sus siglas en inglés), endurecidos mediante técnicas RHBD. Las técnicas RHBD habituales se basan en la adición de elementos redundantes idénticos al original, cuyos resultados se pueden comparar entre sí para obtener información acerca de la existencia de un error (si sólo se usa un circuito redundante, Duplicación Con Comparación [DWC]) o llegar incluso a corregir un error detectado de manera automática, si se emplean dos o más réplicas redundantes, siendo el caso más habitual la Redundancia Modular Triple (TMR) en todas sus variantes. El trabajo desarrollado en esta Tesis gira en torno a las técnicas de endurecimiento RHBD de sistemas electrónicos comerciales. En concreto, se trata de proponer y caracterizar nuevas técnicas de endurecimiento que permitan reducir el alto consumo de recursos de las utilizadas habitualmente. Para ello, se han desarrollado técnicas de endurecimiento que aprovechan cálculos aproximados para detectar y corregir fallos en circuitos electrónicos digitales para procesamiento de señal implementados en FPGA comerciales, dispositivos que permiten implementar circuitos electrónicos digitales a medida y reconfigurarlos tantas veces como se quiera. A lo largo de esta Tesis se han desarrollado diferentes circuitos de prueba endurecidos mediante TMR y se ha comparado su rendimiento con los de otras técnicas de Redundancia Aproximada, en concreto la Redundancia de Precisión Reducida (RPR), la Redundancia de Resolución Reducida (RRR) y la Redundancia Optimizada para Algoritmos Compuestos (ORCA): • La Redundancia de Precisión Reducida se basa en la utilización de dos réplicas redundantes que calculan resultados con un menor número de bits que el circuito original. De este modo se pueden disminuir los recursos necesitados por el circuito, aunque las correcciones en caso de fallo son menos precisas que en el TMR. En este trabajo exploramos también la RPR Escalada como un método de obtener un balance óptimo entre la precisión y el consumo de recursos. • La Redundancia de Resolución Reducida es una técnica propuesta originalmente en esta tesis. Está pensada para algoritmos que trabajan con información en forma de paquetes cuyos datos individuales guardan alguna relación entre sí. Las réplicas redundantes calculan los resultados con una fracción de los datos de entrada originales, lo que reduce su tamaño y permite correcciones aproximadas en caso de fallo. • La Redundancia Optimizada para Algoritmos Compuestos es también una aportación original de esta tesis. Está indicada para algoritmos cuyo resultado final puede expresarse como la composición de resultados intermedios calculados en etapas anteriores. Las réplicas redundantes se forman como bloques que calculan resultados intermedios y el resultado de su composición se puede comparar con el resultado original. Este método permite reducir recursos y proporciona resultados de corrección exactos en la mayor parte de los casos, lo que supone una mejora importante con respecto a las correcciones de los métodos anteriores. La eficacia de las técnicas de endurecimiento desarrolladas se ha probado mediante experimentos de inyección de fallos y mediante ensayos en instalaciones de aceleradores de partículas preparadas para la irradiación de dispositivos electrónicos. En concreto, se han realizado ensayos de radiación con protones en el Centro Nacional de Aceleradores (CNA España), el Paul Scherrer Institut (PSI, Suiza) y ensayos de radiación con neutrones en el laboratorio ISIS Neutron and Muon Source (ChipIR, Reino Unido)., RESUMEN TÉCNICO. Se llama radiación al proceso por el cual una partícula o una onda es capaz de transmitir energía a través del espacio o un medio material. Si la energía transmitida es suficientemente alta, la radiación puede provocar que algunos electrones se desplacen de su posición, en un proceso llamado ionización. La radiación ionizante puede provocar problemas a los seres vivos, pero también a los diversos materiales que componen los sistemas eléctricos y electrónicos utilizados en entornos sujetos a radiación. Existen en La Tierra varios procesos que emiten radiación ionizante, como la obtención de energía en centrales nucleares o ciertos procedimientos médicos. Sin embargo, las fuentes de radiación más importantes se sitúan más allá de nuestra atmósfera y afectan fundamentalmente a sistemas aeroespaciales y vuelos de gran altitud. Debido a la radiación, los sistemas electrónicos que se exponen a cualquiera de estas fuentes sufren degradación en sus propiedades a lo largo del tiempo y pueden sufrir fallos catastróficos que acorten su vida útil. El envejecimiento de los componentes se produce por acumulación de carga eléctrica en el material, lo que se conoce como Dosis Ionizante Total (TID, Total Ionizing Dose), o por distorsiones acumuladas en la matriz cristalina del silicio en el que se fabrican los circuitos, lo que se conoce como Daño por Desplazamiento (DD, Displacement Damage). Una única partícula ionizante puede, sin embargo, provocar también diversos tipos de fallos transitorios o permanentes en los componentes de un circuito, generalmente por un cambio de estado en un elemento de memoria o la activación de circuitos parasitarios en un transistor. Los diferentes tipos de fallos producidos en circuitos por la acción de una única partícula ionizante se engloban en la categoría de Efectos de Evento Único (SEE, Single Event Effects). Para proteger los sistemas electrónicos frente a los efectos de la radiación se suele recurrir a un conjunto de técnicas que llamamos endurecimiento frente a radiación. Los procedimientos tradicionales de endurecimiento han consistido en la fabricación de componentes electrónicos mediante procesos especiales que les confieran una resistencia inherente frente a la TID, el DD y los SEE. A este conjunto de técnicas de endurecimiento se lo conoce como Endurecimiento frente a la Radiación Por Proceso (RHBP, por sus siglas en inglés). Estos procedimientos suelen aumentar el coste de los componentes y empeorar su rendimiento con respecto a los componentes que usamos en nuestros sistemas electrónicos cotidianos. En oposición a las técnicas RHBP encontramos las técnicas de Endurecimiento frente a la Radiación Por Diseño (RHBD, por sus siglas en inglés). Estas técnicas permiten detectar y tratar de corregir fallos producidos por la radiación introduciendo modificaciones en los circuitos. Estas modificaciones suelen aumentar la complejidad de los circuitos que se quiere endurecer, haciendo que consuman más energía, ocupen más espacio o funcionen a menor frecuencia, pero estas desventajas se pueden compensar con la disminución de los costes de fabricación y la mejora en las prestaciones que aportan los sistemas modernos. En un intento por reducir el coste de las misiones espaciales y mejorar sus capacidades, en los últimos años se trata de introducir un mayor número de Componentes Comerciales (COTS, por sus siglas en inglés), endurecidos mediante técnicas RHBD. Las técnicas RHBD habituales se basan en la adición de elementos redundantes idénticos al original, cuyos resultados se pueden comparar entre sí para obtener información acerca de la existencia de un error (si sólo se usa un circuito redundante, Duplicación Con Comparación [DWC, Duplication With Comparison]) o llegar incluso a corregir un error detectado de manera automática, si se emplean dos o más réplicas redundantes, siendo el caso más habitual la Redundancia Modular Triple (TMR, Triple Modular Redundancy) en todas sus variantes. El trabajo desarrollado en esta Tesis gira en torno a las técnicas de endurecimiento RHBD de sistemas electrónicos comerciales. En concreto, se trata de proponer y caracterizar nuevas técnicas de endurecimiento que permitan reducir el alto consumo de recursos de las técnicas utilizadas habitualmente. Para ello, se han desarrollado técnicas de endurecimiento que aprovechan cálculos aproximados para detectar y corregir fallos en circuitos electrónicos digitales para procesamiento de señal implementados en FPGA (Field Programmable Gate Array) comerciales. Las FPGA son dispositivos que permiten implementar circuitos electrónicos digitales diseñados a medida y reconfigurarlos tantas veces como se quiera. Su capacidad de reconfiguración y sus altas prestaciones las convierten en dispositivos muy interesantes para aplicaciones espaciales, donde realizar cambios en los diseños no suele ser posible una vez comenzada la misión. La reconfigurabilidad de las FPGA permite corregir en remoto posibles problemas en el diseño, pero también añadir o modificar funcionalidades a los circuitos implementados en el sistema. La eficacia de las técnicas de endurecimiento desarrolladas e implementadas en FPGAs se ha probado mediante experimentos de inyección de fallos y mediante ensayos en instalaciones de aceleradores de partículas preparadas para la irradiación de dispositivos electrónicos. Los ensayos de radiación son el estándar industrial para probar el comportamiento de todos los sistemas electrónicos que se envían a una misión espacial. Con estos ensayos se trata de emular de manera acelerada las condiciones de radiación a las que se verán sometidos los sistemas una vez hayan sido lanzados y determinar su resistencia a TID, DD y/o SEEs. Dependiendo del efecto que se quiera observar, las partículas elegidas para la radiación varían, pudiendo elegirse entre electrones, neutrones, protones, iones pesados, fotones... Particularmente, los ensayos de radiación realizados en este trabajo, tratándose de un estudio de técnicas de endurecimiento para sistemas electrónicos digitales, están destinados a establecer la sensibilidad de los circuitos estudiados frente a un tipo de SEE conocido como Single Event Upset (SEU), en el que la radiación modifica el valor lógico de un elemento de memoria. Para ello, hemos recurrido a experimentos de radiación con protones en el Centro Nacional de Aceleradores (CNA, España), el Paul Scherrer Institut (PSI, Suiza) y experimentos de radiación con neutrones en el laboratorio ISIS Neutron and Muon Source (ChipIR, Reino Unido). La sensibilidad de un circuito suele medirse en términos de su sección eficaz (cross section) con respecto a una partícula determinada, calculada como el cociente entre el número de fallos encontrados y el número de partículas ionizantes por unidad de área utilizadas en la campaña de radiación. Esta métrica sirve para estimar el número de fallos que provocará la radiación a lo largo de la vida útil del sistema, pero también para establecer comparaciones que permitan conocer la eficacia de los sistemas de endurecimiento implementados y ayudar a mejorarlos. El método de inyección de fallos utilizado en esta Tesis como complemento a la radiación se basa en modificar el valor lógico de los datos almacenados en la memoria de configuración de la FPGA. En esta memoria se guarda la descripción del funcionamiento del circuito implementado en la FPGA, por lo que modificar sus valores equivale a modificar el circuito. En FPGAs que utilizan la tecnología SRAM en sus memorias de configuración, como las utilizadas en esta Tesis, este es el componente más sensible a la radiación, por lo que es posible comparar los resultados de la inyección de fallos y de las campañas de radiación. Análogamente a la sección eficaz, en experimentos de inyección de fallos podemos hablar de la tasa de error, calculada como el cociente entre el número de fallos encontrados y la cantidad de bits de memoria inyectados. A lo largo de esta Tesis se han desarrollado diferentes circuitos endurecidos mediante Redundancia Modular Triple y se ha comparado su rendimiento con los de otras técnicas de Redundancia Aproximada, en concreto la Redundancia de Precisión Reducida (RPR), la Redundancia de Resolución Reducida (RRR) y la Redundancia Optimizada para Algoritmos Compuestos (ORCA). Estas dos últimas son contribuciones originales presentadas en esta Tesis. • La Redundancia de Precisión Reducida se basa en la utilización de dos réplicas redundantes que calculan resultados con un menor número de bits que el circuito original. Para cada dato de salida se comparan el resultado del circuito original y los dos resultados de precisión reducida. Si los dos resultados de precisión reducida son idénticos y su diferencia con el resultado de precisión completa es mayor que un determinado valor umbral, se considera que existe un fallo en el circuito original y se utiliza el resultado de precisión reducida para corregirlo. En cualquier otro caso, el resultado original se considera correcto, aunque pueda contener errores tolerables por debajo del umbral de comparación. En comparación con un circuito endurecido con TMR, los diseños RPR utilizan menos recursos, debido a la reducción en la precisión de los cálculos de los circuitos redundantes. No obstante, esto también afecta a la calidad de los resultados obtenidos cuando se corrige un error. En este trabajo exploramos también la RPR Escalada como un método de obtener un balance óptimo entre la precisión y el consumo de recursos. En esta variante de la técnica RPR, los resultados de cada etapa de cálculo en los circuitos redundantes tienen una precisión diferente, incrementándose hacia las últimas etapas, en las que el resultado tiene la misma precisión que el circuito original. Con este método se logra incrementar la calidad de los datos corregidos a la vez que se reducen los recursos utilizados por el endurecimiento. Los resultados de las campañas de radiación y de inyección de fallos realizadas sobre los diseños endurecidos con RPR sugieren que la reducción de recursos no sólo es beneficiosa por sí misma en términos de recursos y energía utilizados por el sistema, sino que también conlleva una reducción de la sensibilidad de los circuitos, medida tanto en cross section como en tasa de error. • La Redundancia de Resolución Reducida es una técnica propuesta originalmente en esta tesis. Está indicada para algoritmos que trabajan con información en forma de paquetes cuyos datos individuales guardan alguna relación entre sí, como puede ser un algoritmo de procesamiento de imágenes. En la técnica RRR, se añaden dos circuitos redundantes que calculan los resultados con una fracción de los datos de entrada originales. Tras el cálculo, los resultados diezmados pueden interpolarse para obtener un resultado aproximado del mismo tamaño que el resultado del circuito original. Una vez interpolados, los resultados de los tres circuitos pueden ser comparados para detectar y corregir fallos de una manera similar a la que se utiliza en la técnica RPR. Aprovechando las características del diseño hardware, la disminución de la cantidad de datos que procesan los circuitos de Resolución Reducida puede traducirse en una disminución de recursos, en lugar de una disminución de tiempo de cálculo. De esta manera, la técnica RRR es capaz de reducir el consumo de recursos en comparación a los que se necesitarían si se utilizase un endurecimiento TMR. Los resultados de los experimentos realizados en diseños endurecidos mediante Redundancia de Resolución Reducida sugieren que la técnica es eficaz en reducir los recursos utilizados y, al igual que pasaba en el caso de la Redundancia de Precisión Reducida, también su sensibilidad se ve reducida, comparada con la sensibilidad del mismo circuito endurecido con Redundancia Modular Triple. Además, se observa una reducción notable de la sensibilidad de los circuitos frente a errores no corregibles, comparado con el mismo resultado en TMR y RPR. Este tipo de error engloba aquellos producidos por fallos en la lógica de comparación y votación o aquellos en los que un único SEU produce fallos en los resultados de dos o más de los circuitos redundantes al mismo tiempo, lo que se conoce como Fallo en Modo Común (CMF). No obstante, también se observa que la calidad de las correcciones realizadas utilizando este método empeora ligeramente. • La Redundancia Optimizada para Algoritmos Compuestos es también una aportación original de esta tesis. Está indicada para algoritmos cuyo resultado final puede expresarse como la composición de resultados intermedios calculados en etapas anteriores. Para endurecer un circuito usando esta técnica, se añaden dos circuitos redundantes diferentes entre sí y que procesan cada uno una parte diferente del conjunto de datos de entrada. Cada uno de estos circuitos aproximados calcula un resultado intermedio. La composición de los dos resultados intermedios da un resultado idéntico al del circuito original en ausencia de fallos. La detección de fallos se realiza comparando el resultado del circuito original con el de la composición de los circuitos aproximados. En caso de ser diferentes, se puede determinar el origen del fallo comparando los resultados aproximados intermedios frente a un umbral. Si la diferencia entre los resultados intermedios supera el umbral, significa que el fallo se ha producido en uno de los circuitos aproximados y que el resultado de la composición no debe ser utilizado en la salida. Al igual que ocurre en la Redundancia de Precisión Reducida y la Redundancia de Resolución Reducida, utilizar un umbral de comparación implica la existencia de errores tolerables. No obstante, esta técnica de endurecimiento permite realizar correcciones exactas, en lugar de aproximadas, en la mayor parte de los casos, lo que mejora la calidad de los resultados con respecto a otras técnicas de endurecimiento aproximadas, al tiempo que reduce los recursos utilizados por el sistema endurecido en comparación con las técnicas tradicionales. Los resultados de los experimentos realizados con diseños endurecidos mediante Redundancia Optimizada para Algoritmos Compuestos confirman que esta técnica de endurecimiento es capaz de producir correcciones exactas en un alto porcentaje de los eventos. Su sensibilidad frente a todo tipo de errores y frente a errores no corregibles también se ve disminuida, comparada con la obtenida con Redundancia Modular Triple. Los resultados presentados en esta Tesis respaldan la idea de que las técnicas de Redundancia Aproximada son alternativas viables a las técnicas de endurecimiento frente a la radiación habituales, siempre que las características del sistema toleren la presencia de resultados no exactos. La Redundancia Aproximada logra reducir el área y el consumo de recursos de los circuitos endurecidos a costa de realizar correcciones aproximadas, que van desde obtener menor precisión en los resultados corregidos (RPR), correcciones basadas en resultados correctos próximos (RRR) o correcciones exactas en algunos casos y de menor precisión en otros (ORCA). En cualquiera de los casos, estas correcciones aproximadas pueden ser percibidas como mero ruido por el sistema y no afectar a su funcionalidad. Las campañas de radiación y de inyección de fallos muestran que las técnicas de Endurecimiento Aproximado reducen la sensibilidad de los circuitos endurecidos (con respecto a la del mismo circuito endurecido con Redundancia Modular Triple) como consecuencia de la reducción de recursos. Comparar los resultados de ambos tipos de campañas nos ha permitido establecer una relación entre ellas, lo que valida el método de inyección de fallos y lo sitúa como una manera rápida y económica de obtener resultados preliminares. La inyección de fallos nos ha permitido, por un lado, depurar el funcionamiento de las técnicas propuestas sin necesidad de someterlas a ensayos de radiación o largas campañas de simulación, y por otro, conocer de antemano la sensibilidad y capacidad de corrección de errores de las técnicas de endurecimiento propuestas. Estas dos ventajas nos han permitido realizar una planificación de las campañas de radiación más adecuada, aprovechando al máximo el tiempo de radiación disponible y minimizando los costes de los experimentos. Además de estas características, los resultados obtenidos sugieren que la manera en que las técnicas de Redundancia de Resolución Reducida y en la Redundancia Optimizada para Algoritmos Compuestos tratan los datos reduce la incidencia de Fallos en Modo Común, que son responsables de gran parte de los fallos no corregibles en todos los sistemas endurecidos mediante técnicas RHBD., TECHNICAL SUMMARY. Radiation is the process by which a particle or wave is able to transmit energy through space or a material medium. If the energy transmitted is high enough, radiation can cause some electrons to move out of position, in a process called ionization. Ionizing radiation can cause problems for living beings, but also for the various materials that make up electrical and electronic systems used in environments subject to radiation. There are several processes on Earth that emit ionizing radiation, such as obtaining energy in nuclear power plants or certain medical procedures. However, the most important sources of radiation are located beyond our atmosphere and mainly affect aerospace systems and high-altitude flights. Due to radiation, electronic systems exposed to any of these sources suffer degradation in their properties over time and can suffer catastrophic failures that shorten their useful life. Component aging is caused by accumulation of electrical charge in the material, known as Total Ionizing Dose (TID), or by accumulated distortions in the crystalline matrix of the silicon in which the circuits are made, known as Displacement Damage (DD). A single ionizing particle can, however, also cause various types of transient or permanent failures in the components of a circuit, usually by a change of state in a memory element or the activation of parasitic circuits in a transistor. The different types of faults produced in circuits by the action of a single ionizing particle fall into the category of Single Event Effects (SEE). To protect electronic systems against the effects of radiation, a set of techniques known as radiation hardening is often used. Traditional hardening procedures have consisted of manufacturing electronic components using special processes that give them inherent resistance to TID, DD and SEE. This set of hardening techniques is known as Radiation Hardening By Process (RHBP). These procedures tend to increase the cost of components and worsen their performance relative to the components we use in our everyday electronic systems. In opposition to RHBP techniques we find Radiation Hardening by Design (RHBD) techniques. These techniques allow us to detect and attempt to correct radiation induced failures by introducing modifications to the circuits. These modifications often increase the complexity of the circuits to be hardened, causing them to consume more power, take up more space or operate at a lower frequency. However, these disadvantages can be offset by the reduced manufacturing costs and improved performance provided by modern systems. In an attempt to reduce the cost of space missions and improve their capabilities, efforts have been made in recent years to introduce more Commercial Off-The-Shelf (COTS) components, hardened with RHBD approaches The usual RHBD techniques are based on the addition of redundant elements identical to the original, whose results can be compared with each other to obtain information about the existence of an error (if only one redundant circuit is used, Duplication With Comparison [DWC]) or even to correct an error detected automatically, if two or more redundant replicas are used, the most common case being Triple Modular Redundancy (TMR) in all its variants. The work developed in this Thesis revolves around RHBD hardening techniques for commercial electronic systems. Specifically, the aim is to propose and characterize new hardening techniques to reduce the high resource consumption of commonly used techniques. To this end, we have developed hardening techniques that take advantage of approximate calculations to detect and correct faults in digital electronic circuits for signal processing implemented in commercial FPGAs (Field Programmable Gate Array). FPGAs are devices that allow custom-designed digital electronic circuits to be implemented and reconfigured as many times as desired. Their reconfigurability and high performance make them very interesting devices for space applications, where design changes are usually not possible once the mission has started. The reconfigurability of FPGAs allows to remotely correct possible problems in the design, but also to add or modify functionalities to the circuits implemented in the system. The effectiveness of the hardening techniques developed and implemented in FPGAs has been proven by fault injection experiments and by testing in particle accelerator facilities prepared for irradiation of electronic devices. Irradiation tests are the industry standard for testing the behavior of all electronic systems that are sent on a space mission. The purpose of these tests is to emulate in an accelerated manner the radiation conditions to which the systems will be subjected once they have been launched and to determine their resistance to TID, DD and/or SEEs. Depending on the effects to be observed, the particles chosen for the radiation vary, being able to choose between electrons, neutrons, protons, heavy ions, photons... In particular, the radiation tests carried out in this work, being a study of hardening techniques for digital electronic systems, are aimed at establishing the sensitivity of the circuits studied against a type of SEE known as Single Event Upset (SEU), in which radiation modifies the logic value of a memory element. For this purpose, we have used radiation experiments with protons at the Centro Nacional de Aceleradores (CNA, Spain), the Paul Scherrer Institut (PSI, Switzerland) and radiation experiments with neutrons at the ISIS Neutron and Muon Source laboratory (ChipIR, UK). The sensitivity of a circuit is usually measured in terms of its cross section with respect to a given particle, calculated as the ratio between the number of faults found in the test and the amount of ionizing particles per area used in the radiation campaign. This metric is used to estimate the number of faults that will be caused by the radiation over the lifetime of the system, but also to gather data about the effectiveness of the implemented hardening systems and to help improve them. The fault injection method used in this Thesis as a complement to radiation is based on modifying the logic value of the data stored in the configuration memory of the FPGA. This memory stores the description of the operation of the circuit implemented in the FPGA, so modifying its values is equivalent to modifying the circuit. In FPGAs that use SRAM technology in their configuration memories, such as those used in this Thesis, this is the component most sensitive to radiation, so it is possible to compare the results of fault injection and radiation campaigns. Analogously to the cross section, in fault injection experiments we can talk about the error rate, calculated as the ratio between the number of faults found and the amount of memory bits injected. Throughout this Thesis, different circuits hardened by Triple Modular Redundancy have been developed and their performance has been compared with those of other Approximate Redundancy techniques, namely Reduced Precision Redundancy (RPR), Reduced Resolution Redundancy (RRR) and Optimized Redundancy for Composite Algorithms (ORCA). The latter two are original contributions presented in this Thesis. • Reduced Precision Redundancy is based on the use of two redundant replicas that compute results with a smaller number of bits than the original circuit. For each output data, the result of the original circuit and the two reduced-precision results are compared. If the two reduced-precision results are identical and their difference with the full-precision result is greater than a certain threshold value, a fault is considered to exist in the original circuit and the reduced-precision result is used to correct it. In any other case, the original result is considered correct, even though it may contain tolerable errors below the comparison threshold. Compared to a TMR-hardened circuit, RPR designs use fewer resources, due to the reduced precision of redundant circuit calculations. However, this also affects the quality of the results obtained when an error is corrected. In this work we also explore Scaled RPR as a method of obtaining an optimal balance between accuracy and resource consumption. In this variant of the RPR technique, the results of each computational stage in the redundant circuits have a different precision, increasing towards the last stages of the pipeline, where the result has the same accuracy as the original circuit. This method increases the quality of the corrected data while reducing the resources used for hardening. The results of the radiation and fault injection campaigns performed on the RPR hardened designs suggest that the reduction of resources is not only beneficial in terms of resources and energy used by the system, but also leads to a reduction of the sensitivity of the circuits, measured both in cross section and error rate. • Reduced Resolution Redundancy is a technique originally proposed in this Thesis. It is suitable for algorithms that work with information in the form of packets whose individual data have some relationship with each other, such as an image processing algorithm. In the RRR technique, two redundant circuits are added that compute the results with a fraction of the original input data. After calculation, the decimated results can be interpolated to obtain an approximate result of the same size as the result of the original circuit. Once interpolated, the results of the three circuits can be compared to detect and correct faults in a similar way to that used in the RPR technique. By taking advantage of hardware design features, the decrease in the amount of data processed by the Reduced Resolution circuits are translated into a decrease in resources, rather than a decrease in computational time. In this way, the RRR technique is able to reduce resource consumption compared to what would be required if TMR hardening were used. The results of the experiments performed on designs hardened with Reduced Resolution Redundancy suggest that the technique is effective in reducing the resources used and, as in the case of Reduced Precision Redundancy, its sensitivity is also reduced compared to the sensitivity of the same circuit hardened with TMR. In addition, there is a notable reduction in the sensitivity of the circuits to uncorrectable errors, compared to the same result in TMR and RPR. This type of error encompasses those produced by failures in the comparison and voting logic or those in which a single SEU produces failures in the results of two or more of the redundant circuits at the same time, which is known as Common Mode Failure (CMF). However, it is also observed that the quality of the corrections performed using this method worsens slightly. • Optimized Redundancy for Composite Algorithms is also an original contribution of this Thesis. It is suitable for algorithms whose final result can be expressed as the composition of intermediate results computed in previous stages. To harden a circuit using this technique, two redundant circuits are added that are different from each other, each of them processing a different part of the input data set. Each of these approximate circuits computes an intermediate result. The composition of the two intermediate results gives a result identical to that of the original circuit in the absence of faults. Fault detection is performed by comparing the result of the original circuit with that of the composition of the approximate circuits. In case they are different, the origin of the fault can be determined by comparing the intermediate approximate results against a threshold. If the difference between the intermediate results exceeds the threshold, it means that the fault has occurred in one of the approximate circuits and that the result of the composition should not be used in the output. As with Reduced Precision Redundancy and Reduced Resolution Redundancy, using a comparison threshold implies the existence of tolerable errors. However, this hardening technique allows precise, rather than approximate, corrections to be made in most cases, which improves the quality of the results with respect to other approximate hardening techniques, while reducing the resources used by the hardened system compared to traditional techniques. The results of experiments performed with hardened designs using Optimized Redundancy for Composite Algorithms confirm that this hardening technique is capable of producing precise corrections in a high percentage of the events. Its sensitivity to all types of errors and to uncorrectable errors is also diminished compared to that obtained with Triple Modular Redundancy. The results presented in this Thesis support the idea that Approximate Redundancy techniques are viable alternatives to the usual radiation hardening techniques, provided that the system characteristics tolerate the presence of inaccurate results. Approximate Redundancy manages to reduce the area and resource consumption of hardened circuits at the cost of making approximate corrections, ranging from obtaining lower accuracy in the corrected results (RPR), corrections based on close correct results (RRR) or exact corrections in some cases and lower precision in others (ORCA). In either case, these approximate corrections may be perceived as mere noise by the system and not affect its functionality. Radiation and fault injection campaigns show that Approximate Hardening techniques reduce the sensitivity of hardened circuits (with respect to that of the same circuit hardened with Triple Modular Redundancy) as a consequence of reduced resources. Comparing the results of both types of campaigns has allowed us to establish a relationship between them, which validates the fault injection method and positions it as a fast and inexpensive way to obtain preliminary results. Fault injection has allowed us, on the one hand, to refine the performance of the proposed techniques without the need to test them in radiation campaigns or long simulation campaigns, and on the other hand, to know in advance the sensitivity and error correction capacity of the proposed hardening techniques. These two advantages have allowed us to carry out a more adequate planning of the radiation campaigns, making the best use of the available radiation time and minimizing the costs of the experiments. In addition to these features, the results obtained suggest that the way in which the techniques of Reduced Resolution Redundancy and Optimized Redundancy for Composite Algorithms treat the data reduces the incidence of Common Mode Failures, which are responsible for a large part of the uncorrectable failures in all the systems hardened by RHBD techniques., NON-TECHNICAL SUMMARY. Radiation is the process by which a particle or wave is able to transmit energy through space or a material medium. If the energy transmitted is high enough, radiation can cause some electrons to move out of position, in a process called ionization. Ionizing radiation can cause problems for living beings, but also for the various materials that make up electrical and electronic systems used in environments subject to radiation. There are several processes on Earth that emit ionizing radiation, such as obtaining energy in nuclear power plants or certain medical procedures. However, the most important sources of radiation are located beyond our atmosphere and mainly affect aerospace systems and high-altitude flights. Due to radiation, electronic systems exposed to any of these sources suffer degradation in their properties over time and can suffer catastrophic failures that shorten their useful life. Component aging is caused by accumulation of electrical charge in the material, known as Total Ionizing Dose (TID), or by distortions in the silicon on which the circuits are fabricated, known as Displacement Damage (DD). A single ionizing particle can, however, also cause various types of transient or permanent failures in the components of a circuit, usually by a change of state in a memory element or destructive failures in a transistor. The different types of failures produced in circuits by the action of a single ionizing particle fall into the category of Single Event Effects (SEE). To protect electronic systems against the effects of radiation, a set of techniques known as radiation hardening is commonly used. Traditional hardening procedures have consisted of manufacturing electronic components using special processes that give them inherent resistance to TID, DD and SEE. This set of hardening techniques is known as Radiation Hardening By Process (RHBP). These procedures tend to increase the cost of components and worsen their performance relative to the components we use in our everyday electronic systems. Opposed to RHBP techniques we find Radiation Hardening By Design (RHBD) techniques. These techniques allow us to detect faults and attempt to correct them by inserting modifications in the circuit. These modifications typically increase the complexity of the circuits to be hardened, causing them to consume more power, use more area or operate at lower frequencies, but these disadvantages can be compensated by the lower costs and improved performance provided by modern systems. In an attempt to reduce the cost of space missions and improve their capabilities, efforts have been made in recent years to introduce more Commercial Off-The-Shelf (COTS) components, hardened with RHBD approaches. The usual RHBD techniques are based on the addition of redundant elements identical to the original, whose results can be compared with each other to obtain information about the existence of an error (if only one redundant circuit is used, Duplication With Comparison [DWC]) or even correct an error detected automatically, if two or more redundant replicas are used, the most common case being Triple Modular Redundancy (TMR) in all its variants. The work developed in this Thesis revolves around RHBD hardening techniques for commercial electronic systems. Specifically, the aim is to propose and characterize new hardening techniques to reduce the high resource consumption of those commonly used. For this purpose, we have developed hardening techniques that take advantage of approximate calculations to detect and correct faults in digital electronic circuits for signal processing implemented in commercial FPGA, devices that allow to implement custom digital electronic circuits and reconfigure them as many times as desired. Throughout this Thesis, different TMR-hardened test circuits have been developed and their performance has been compared with those of other Approximate Redundancy techniques, namely Reduced Precision Redundancy (RPR), Reduced Resolution Redundancy (RRR) and Optimized Redundancy for Composite Algorithms (ORCA): • Reduced Precision Redundancy is based on the use of two redundant replicas that compute results with a smaller number of bits than the original circuit. In this way, the resources needed by the circuit can be decreased, although the corrections in case of failure are less accurate than in TMR. In this paper we also explore Scaled RPR as a method of obtaining an optimal balance between accuracy and resource consumption. • Reduced Resolution Redundancy is a technique originally proposed in this thesis. It is intended for algorithms that work with information in the form of packets whose individual data have some relationship with each other. Redundant replicas compute results with a fraction of the original input data, which reduces their size and allows approximate corrections in case of failure. • Optimized Redundancy for Composite Algorithms is also an original contribution of this thesis. It is suitable for algorithms whose final result can be expressed as the composition of intermediate results computed in previous stages. Redundant replicas are formed as blocks that compute intermediate results and the result of their composition can be compared with the original result. This method reduces resources and provides accurate correction results in most cases, which is a significant improvement over the corrections of previous methods. The effectiveness of the developed hardening techniques has been tested by fault injection experiments and by testing in particle accelerator facilities prepared for irradiation of electronic devices. In particular, proton irradiation campaigns have been carried out at Centro Nacional de Aceleradores (CNA, Spain) and at Paul Scherrer Institut (PSI, Switzerland), and neutron irradiation campaigns have been performed at the ISIS Neutron and Muon Source laboratory (ChipIR, United Kingdom)., This work has been supported in part by the Spanish Ministry of Science and Innovation under project PID2019-106455GB-C21, by the Community of Madrid under project no. 49.520608.9.18 and by the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 101008126 in the framework of the EU project RADNEXT., Programa de Doctorado en Ingeniería Eléctrica, Electrónica y Automática por la Universidad Carlos III de Madrid, Presidente: Roberto Sarmiento Rodríguez.- Secretario: Eduardo de la Torre Arnanz.- Vocal: Sergio Cuenca Asensi
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Artículo científico (JournalArticle)

Reliability assessment of AMD MicroBlaze-V TMR architecture using fault injection and proton irradiation

  • Cano Páez, Jorge
  • Entrena Arrontes, Luis Alfonso
  • Lindoso Muñoz, Almudena
This work analyses the robustness of the recent AMD RISC-V processor: MicroBlaze-V. We study the TMR fault tolerant version of the MicroBlaze-V architecture, implemented in an SRAM-based FPGA. The architecture has been evaluated with fault injection and irradiation campaigns using 15 and 230 MeV proton beams. Experimental results show that AMD TMR MicroBlaze-V architecture offers a fast and flexible design process with good error mitigation of faults in the configuration memory. The results obtained show a good correlation between fault injection and proton irradiation campaigns, which may be used for error-rate estimations and precise error mitigation strategies. Overall, AMD TMR MicroBlaze-V has an error detection rate of around 99.84%. Approximately 1% of failures are not warned beforehand, although experimental data show that these errors are related to the memory, which is triplicated. It is calculated that, under the evaluated conditions, the mean time for a system failure is twice the mean time for a non-fatal error to happen. The cross-section is estimated to be 47 and 65 times better for failures with a previous warning compared to failures without warning in experiments with protons of 15 MeV and 230 MeV respectively., This work has been supported in part by the Community of Madrid, under grant PIPF-2024/TEC-34925, by project PID2022–138696OB- C21 funded by MCIN/AEI/10.13039/501,100,011,033 and by “ERDF A way of making Europe”, and in part by the European Union’s Horizon 2020 Research and Innovation Program through the Framework of the European Union (EU) Project RADiation facility Network for the Exploration of Effects for indusTry and research (RADNEXT) under Grant 101008126.
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Artículo científico (JournalArticle)

Evaluation of a Robust System for Hyperspectral Data Compression Under Neutron and Proton Effects

  • Entrena Arrontes, Luis Alfonso
  • Sánchez Clemente, Antonio José
  • García Valderas, Mario
  • Barrios, Yubal
  • Sarmiento, Roberto
  • Lindoso Muñoz, Almudena
The use of hyperspectral sensors in space missions is steadily increasing. These sensors generate large volumes of data in the form of hyperspectral cubes (images captured in hundreds of different wavelengths) which require the adoption of data compression solutions onboard. In this work we evaluate error mitigation for CCSDS-123 hyperspectral data loss less compression IP. Realizing that a data compressor has to be used with some data interfaces and possibly a processor, the evaluation is performed for entire systems built around the SHyLoC CCSDS-123 IP core. To this purpose, we designed hardened systems that include redundant IP cores, input and output data stream interfaces, and processors. The hardened systems were implemented in a commercial SoC device and tested with atmospheric neutrons and protons. Experimental results are presented and discussed for two architectures using dual and triple IP core redundancy, respectively., The authors would like to acknowledge ISIS (UK) for providing the neutron beam time and to Centro Nacional de Aceleradores (Spain) for the access to the proton beam. We would like to thank Chris Frost, Carlo Cazzaniga and Maria Kastriotou for their help with the neutron experiment, and Yolanda Morilla, Amor Romero and Pedro Martín-Holgado for their help with the proton experiment.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Mixed-Field Radiation Monitoring and Beam Characterization Through Silicon Diode Detectors

  • Bilko, Kacper
  • García Alía, Rubén
  • Sacristán Barbero, Mario
  • Girard, Sylvain
  • Aguiar, Ygor Q.
  • Cecchetto, Matteo
  • Belanger-Champagne, Camille
  • Danzeca, Salvatore
  • Hajdas, Wojtek
  • Hands, Alex
  • Martín Holgado, Pedro
  • Morilla, Yolanda
  • Romero-Maestre, Amor
  • Prelipcean, Daniel
  • Ravotti, Federico
  • Sebban, Marc
We present a calibration of a commercial silicon diode with proton and alpha beams and gamma rays. The diode together with a fast acquisition chain can be exploited for both direct and indirect (through the secondary radiation field) beam characterization. Within this work, we demonstrate the detector capabilities of resolving single-energy-deposition events and independently measuring dose rate and beam flux. Profiting from the mixed radiation field in CERN's high-energy accelerator mixed field facility (CHARM) we show how the silicon detector can be exploited to characterize the mixed radiation field present in it, which in turn is used for validating the radiation tolerance of components and systems to be installed in the European Organization for Nuclear Research (CERN) accelerator complex., European Union’s Horizon 2020 Research and Innovation Program (Grant Number: 101008126). European Union’s 2020 Research and Innovation Program, corresponding to the RADNEXT project, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Ultra-Large Silicon Diode for Characterizing Low-Intensity Radiation Environments

  • Bilko, Kacper
  • García Alía, Rubén
  • Girard, Sylvain
  • Sacristán Barbero, Mario
  • Cecchetto, Matteo
  • Belanger-Champagne, Camille
  • Brucoli, Matteo
  • Danzeca, Salvatore
  • Hands, Alex
  • Martín Holgado, Pedro
  • Morilla, Yolanda
  • Romero-Maestre, Amor
  • Sebban, Marc
  • Widorski, Markus
We present applications of a large commercial silicon diode (50 cm^2× 500μ m ) for monitoring low-intensity radiation fields, together with benchmarks via Monte Carlo simulations. After energy calibration with monoenergetic proton and alpha beams in the 2-8-MeV range, we show that the detector is capable of measuring atmospheric radiation at the ground level, not only in terms of a total number of events but also through their energy deposition distribution. Focusing on the atmospheric-like neutron spectrum, we prove that the diode detection cross Section is more than five orders of magnitude larger with respect to static random access memory (SRAM)-based solutions and highlight the potential use cases in the accelerator's radiation environment., European Union’s Horizon 2020 Research and Innovation Program (Grant Number: 101008126), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Optical Fiber-Based Sensors for Real-Time Monitoring for Low-Energy Proton Beams

  • Fricano, Fiammetta
  • Weninger, Luca
  • Morana, Adriana
  • Romero-Maestre, Amor
  • Martín Holgado, Pedro
  • Martín Hernández, José de
  • Morilla, Yolanda
  • Lambert, Damien
  • Paillet, Philippe
  • El Hamzaoui, Hicham
  • Capoen, Bruno
  • Bouazaoui, Mohamed
  • Marin, Emmanuel
  • Ouerdane, Youcef
  • Boukenter, Aziz
  • Girard, Sylvain
This work presents the first results from our investigation regarding the potential use of radioluminescent Ce3+-doped silica-based optical fibers as sensors capable of monitoring the flux of low-energy (≤ 15 MeV) protons. This technology is shown as a promising candidate for dosimetry at the Centro Nacional de Aceleradores (CNA), offering improved precision and real-time radiation monitoring during radiation test campaigns on microelectronics or photonics components and devices. Two proton beam lines have been used to characterize the fiber dosimeters in two different CNA facilities, using a 18/9 Cyclotron and a Tandem 3 MV accelerators. The calibration of the sensor for monitoring the proton flux at 15 MeV is currently reliable within a 24% margin, due to the presence of significant beam fluctuations that prevent a unique correlation between radioluminescence levels and the associated flux values. However, this result can be improved through additional tests aimed at refining the calibration process. When using 3 MeV protons, the signal exhibits an enhanced radioluminescence, confirming the high sensitivity of optical fibers to low-energy protons. Physically relevant insights are obtained, as the compact geometry of the optical fiber makes it sufficiently embedded to detect the 3 MeV proton Bragg peak within its sensitive core region. Nevertheless, further investigations are needed to fully understand the radioluminescence mechanism, especially under the high-dose rate conditions involved., This study was supported by European Union's Horizon 2020 research and innovation program (101008126); RADNEXT project., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Performance of a CeBr3 scintillator coupled to a photomultiplier tube with an active voltage divider under high bremsstrahlung fluences

  • García Rivas, I.
  • Fernández Prieto, A.
  • Vázquez Regueiro, P.
  • García Fernández, D.
  • Kögler, T.
  • Römer, K.
  • Hueso-González, F.
Proton therapy lacks a standard method to verify the proton range during the treatments in the clinical routine. In this context, the monitoring of prompt γ-rays in a coaxial geometry using a compact detector based on a CeBr3 scintillator coupled to a commercial photomultiplier tube (PMT) could lead to the identification of proton range deviations. Such detection system could be easily integrated in every treatment room. Although measuring in this geometry profits from an advantageous solid angle, the detector is also exposed to an extreme γ-ray rate, of up to 10 Mcps. In this work, we present the first experimental performance evaluation for the proposed detector by irradiating it at very high bremsstrahlung rates at the γELBE facility. Using a customized active voltage divider to supply voltage to the PMT, the detection system was able to sustain a photon rate higher than 12 Mcps without dead time while keeping gain drifts below 15 % in the best configuration, and to achieve a sub-nanosecond time resolution. © 2025 The Author(s), This work has been supported by Xunta de Galicia, Spain, under the Industrial Doctorates Program 2022 (Galician Innovation Agency) and under grant number ED431C/3, by Ministerio de Ciencia e Innovación, Spain, under project PID2022-140591NB-I00 and by Generalitat Valenciana, Spain, (Conselleria de Educación, Investigación, Cultura y Deporte) under grant number CDEIGENT/2019/011. This work has also received funds from the Particle Therapy Cooperative Group (PTCOG) under project funding 2024 and from the European Union’s 2020 research and innovation program under grant 101008126, corresponding to RADNEXT project. IGFAE is supported by the María de Maeztu grant CEX2023-001318-M and IFIC by the Severo Ochoa Center of Excellence grant CEX2023-001292-S, both funded by MCIU/AEI., Peer reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Radiation effects on NVIDIA Jetson SoCs: Insights from heavy ion irradiation

  • Rodríguez Ferrández, Iván
  • Rufart Blasco, Eric
  • Kosmidis, Leonidas
  • Tali, Maris
  • Steenari, David
This study examines the vulnerability of modern embedded GPUs—specifically the NVIDIA Jetson Orin NX and Xavier NX System-on-Modules (SoMs)—to Single-Event Effects (SEEs) under heavy ion irradiation. Originally developed for safety-critical environments such as automotive systems, these high-performance SoMs integrate advanced computing capabilities with built-in functional safety, positioning them as promising candidates for deployment in radiation-prone domains like space. We assess SEE behavior across various ion energy levels, focusing on the central System-on-Chip (SoC), which includes the CPU, GPU, and peripheral components. Our evaluation covers both the runtime and boot-time phases, providing a comprehensive view of fault susceptibility and its implications for system uptime and reliability in space conditions. The paper presents an in-depth analysis of error signatures observed in both the CPU and GPU due to ion strikes, contrasting these with outcomes from previous proton-based studies. Additionally, we compare the two NVIDIA platforms in terms of SEE types—including Single-Event Latch-up (SEL)—to evaluate their relative robustness and inform their potential adoption in space-grade applications., This work has received funding from the European Union’s H2020 research and innovation programme under grant agreement No 101008126, corresponding to the RADNEXT project. It was also supported by ESA through the 4000136514/21/NL/GLC/my co-funded PhD activity ”Mixed Software/Hardware-based Fault-tolerance Techniques for Complex COTS System-on-Chip in Radiation Environments”. Moreover, it was partially supported by the European Community’s Horizon Europe programme under the METASAT project (grant agreement 101082622) and the Chips Act Joint Undertaking project SMARTY (grant agreement 101140087), the Spanish Ministry of Economy and Competitiveness under grant IJC2020-045931-I (Spanish State Research Agency / http://dx.doi.org/10.13039/501100011033), the Spanish Ministry of Digital Transformation and Public Service through the AI4S initiative (C005/24-ED CV1) and European Union’s Next Generation EU and the Research and University Department of the Generalitat de Catalunya through its support to the Research Group SSAS (Code: 2021 SGR 00637)., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Proton evaluation of single event effects in the NVIDIA GPU Orin SoM: Understanding radiation vulnerabilities beyond the SoC

  • Rodríguez Ferrández, Iván
  • Kosmidis, Leonidas
  • Tali, Maris
  • Steenari, David
  • Hands, Alex
  • Belanger-Champagne, Camille
In this paper, we investigate the single event effects under proton irradiation for the state-of-the-art embedded GPU NVIDIA Jetson Orin NX System-on-Module (SoM). Designed for deployment across safety critical domains and in particularly automotive, this system represents a cutting-edge advancement in high performance embedded computing with functional safety features, which makes it an ideal candidate for use in space systems. Our study evaluates the Single-Event Effects (SEE) manifested within the SoM’s central processing unit (CPU), graphics processing unit (GPU), and associated peripherals. Through our analysis, we aim to delineate the origins of Single Event Functional Interrupts (SEFI) occurring at the SoM level. Furthermore, we provide a detailed exposition on the errors observed within the GPU complex, elucidating the requisite conditions for their manifestation. Unlike previous works which treat embedded GPUs under irradiation as black box, we are able to identify the source of SEEs through ARM’s RAS subsystem, and observe for the first time in literature GPU SEEs. Our investigation culminates in a comprehensive assessment of the SoM’s susceptibility, identifying particularly sensitive components., This work has received funding from the European Union’s H2020 research and innovation programme under grant agreement No 101008126, corresponding to the RADNEXT project. It was also supported by ESA through the 4000136514/21/NL/GLC/my co-funded PhD activity ”Mixed Software/Hardware-based Fault-tolerance Techniques for Complex COTS System-on-Chip in Radiation Environments”. Moreover, it was partially supported by the European Community’s Horizon Europe programme under the METASAT project (grant agreement 101082622), the Spanish Ministry of Economy and Competitiveness under grants PID2019-107255GB-C21 and IJC2020-045931-I (Spanish State Research Agency / http://dx.doi.org/10.13039/501100011033) and the HiPEAC Network of Excellence. TRIUMF receives federal funding via a contribution agreement with the National Research Council of Canada., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Radiation effects on NVIDIA Jetson SoCs: Insights from heavy ion irradiation

  • Rodríguez Ferrández, Iván
  • Rufart Blasco, Eric
  • Kosmidis, Leonidas
  • Tali, Maris
  • Steenari, David
This study examines the vulnerability of modern embedded GPUs—specifically the NVIDIA Jetson Orin NX and Xavier NX System-on-Modules (SoMs)—to Single-Event Effects (SEEs) under heavy ion irradiation. Originally developed for safety-critical environments such as automotive systems, these high-performance SoMs integrate advanced computing capabilities with built-in functional safety, positioning them as promising candidates for deployment in radiation-prone domains like space. We assess SEE behavior across various ion energy levels, focusing on the central System-on-Chip (SoC), which includes the CPU, GPU, and peripheral components. Our evaluation covers both the runtime and boot-time phases, providing a comprehensive view of fault susceptibility and its implications for system uptime and reliability in space conditions. The paper presents an in-depth analysis of error signatures observed in both the CPU and GPU due to ion strikes, contrasting these with outcomes from previous proton-based studies. Additionally, we compare the two NVIDIA platforms in terms of SEE types—including Single-Event Latch-up (SEL)—to evaluate their relative robustness and inform their potential adoption in space-grade applications., This work has received funding from the European Union’s H2020 research and innovation programme under grant agreement No 101008126, corresponding to the RADNEXT project. It was also supported by ESA through the 4000136514/21/NL/GLC/my co-funded PhD activity ”Mixed Software/Hardware-based Fault-tolerance Techniques for Complex COTS System-on-Chip in Radiation Environments”. Moreover, it was partially supported by the European Community’s Horizon Europe programme under the METASAT project (grant agreement 101082622) and the Chips Act Joint Undertaking project SMARTY (grant agreement 101140087), the Spanish Ministry of Economy and Competitiveness under grant IJC2020-045931-I (Spanish State Research Agency / http://dx.doi.org/10.13039/501100011033), the Spanish Ministry of Digital Transformation and Public Service through the AI4S initiative (C005/24-ED CV1) and European Union’s Next Generation EU and the Research and University Department of the Generalitat de Catalunya through its support to the Research Group SSAS (Code: 2021 SGR 00637)., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Proton evaluation of single event effects in the NVIDIA GPU Orin SoM: Understanding radiation vulnerabilities beyond the SoC

  • Rodríguez Ferrández, Iván
  • Kosmidis, Leonidas
  • Tali, Maris
  • Steenari, David
  • Hands, Alex
  • Belanger-Champagne, Camille
In this paper, we investigate the single event effects under proton irradiation for the state-of-the-art embedded GPU NVIDIA Jetson Orin NX System-on-Module (SoM). Designed for deployment across safety critical domains and in particularly automotive, this system represents a cutting-edge advancement in high performance embedded computing with functional safety features, which makes it an ideal candidate for use in space systems. Our study evaluates the Single-Event Effects (SEE) manifested within the SoM’s central processing unit (CPU), graphics processing unit (GPU), and associated peripherals. Through our analysis, we aim to delineate the origins of Single Event Functional Interrupts (SEFI) occurring at the SoM level. Furthermore, we provide a detailed exposition on the errors observed within the GPU complex, elucidating the requisite conditions for their manifestation. Unlike previous works which treat embedded GPUs under irradiation as black box, we are able to identify the source of SEEs through ARM’s RAS subsystem, and observe for the first time in literature GPU SEEs. Our investigation culminates in a comprehensive assessment of the SoM’s susceptibility, identifying particularly sensitive components., This work has received funding from the European Union’s H2020 research and innovation programme under grant agreement No 101008126, corresponding to the RADNEXT project. It was also supported by ESA through the 4000136514/21/NL/GLC/my co-funded PhD activity ”Mixed Software/Hardware-based Fault-tolerance Techniques for Complex COTS System-on-Chip in Radiation Environments”. Moreover, it was partially supported by the European Community’s Horizon Europe programme under the METASAT project (grant agreement 101082622), the Spanish Ministry of Economy and Competitiveness under grants PID2019-107255GB-C21 and IJC2020-045931-I (Spanish State Research Agency / http://dx.doi.org/10.13039/501100011033) and the HiPEAC Network of Excellence. TRIUMF receives federal funding via a contribution agreement with the National Research Council of Canada., Peer Reviewed, Postprint (author's final draft)