Pasar al contenido principal

SISTEMAS ELECTRONICOS DE DETECCION Y TERAPEUTICOS PARA APLICACIONES INTRACORPORALES, EXTRACORPORALES Y WEARABLES

PID2024-155683OB-C44

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para la Investigación y el Desarrollo Experimental
Subprograma Subprograma Estatal de Generación de Conocimiento Científico-Técnico y Desarrollo Experimental
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2024
Plan Estatal 2024-2027 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Low-barrier biosensing using native printed circuit board solder mask

  • Pastor Navarro, Nuria
  • Pérez-Reinoso, Miguel
  • Noguera Murray, Patricia Silvestre|||0000-0001-7155-0710
  • Masot Peris, Rafael|||0000-0002-1114-649X
  • Alcañiz Fillol, Miguel|||0000-0002-4579-9210
  • Hernández-Maciá, Miriam
  • Gimenez-Romero, David
[EN] Although printed circuit board (PCB) biosensors hold promise for ultra-low-cost diagnostics, their widespread implementation is limited by the need for noble-metal electrodes, whose fabrication requires additional processing steps beyond standard PCB manufacturing (e.g., photolithography), substantially increasing device cost. Here, we present a new strategy to repurpose standard industrial PCBs for low-barrier, cost-effective biosensing by imparting functionality to the native epoxy solder mask through surface functionalization that enables selective recognition of target analytes. The solder mask is directly functionalized using 3-mercaptopropionic acid and EDC/NHS chemistry, enabling stable covalent immobilization of bioreceptors and transforming it into a functional recognition element, thereby eliminating the complex fabrication required in typical PCB biosensors. Bound analytes are detected through a frequency-dependent impedance response arising from the distributed capacitive behavior between the solder mask and the underlying copper-based printed circuit. While validated with impedance spectroscopy using bovine serum albumin (BSA) as a model, this functionalized interface can be tailored to detect a wide range of selected targets. The biofunctionalized solder mask surface demonstrates excellent spatial uniformity (<10% variability) and highly sensitive anti-BSA detection below 10 ppb (p < 0.001). By enabling covalent immobilization of recognition elements directly on commercial PCBs, this approach harnesses standard industrial fabrication to deliver accessible, high-performance biosensors for diagnostics and real-time environmental monitoring, marking a major advance in miniaturized, scalable biosensor platforms., This work was supported by Project PID2021-126304OB-C44 funded by MCIN/AEI/10.13039/501100011033 and by FEDER, EU, and by Project PID2024-155683OB-C44 funded by MICIU/AEI/10.13039/501100011033 and by FEDER, EU.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Influence of Pretreatments on the Conductivity of Flexographic Printed Electronics on Flexible Substrates

  • Silvestre, Rocío
  • Llinares Llopis, Raúl|||0000-0002-9732-2262
  • Olguín Pinatti, Cristian Ariel|||0000-0003-3859-1216
  • FERRI PASCUAL, JOSUÉ|||0000-0002-8084-6182
  • Montava-Seguí, Ignacio|||0000-0001-6564-813X
  • Bou-Belda, Eva|||0000-0003-1461-9296
[EN] The development of electronic textiles (e-textiles) has advanced significantly thanks to the integration of printing technologies such as flexography, which enables the efficient and reproducible production of conductive circuits on fabrics. This study evaluates the impact of different surface pretreatments (hydrophobic and oleophobic) on the electrical conductivity of flexographically printed circuits on a variety of polyester textile substrates. Key parameters such as grammage, fabric type and surface uniformity are analyzed using stereomicroscopy and profilometry techniques to characterize conductive ink distribution. The results demonstrate that oleophobic pretreatment is more effective at reducing the resulting electrical resistance, promoting better ink adhesion and distribution. Among the fabrics with the best results, those with a more regular and compact structure, such as 15 thread/cm and 666.7 dtex polyester taffeta, show homogeneous ink coverage and the lowest electrical resistance (~0.5 ¿/cm) compared to more irregular fabrics with discontinuities and higher resistance. The results show that uniformity in ink distribution, assessed by profilometry and color analysis, directly correlates with low electrical resistance. It can be concluded that the combination of a regular and compact textile structure, an adequate surface pretreatment, and a printing direction of the circuit pattern aligned with the weft permits optimizing the conductivity and quality of e-textiles produced by flexography., This work was supported by the Spanish Government/FEDER funds (PID2024-155683OBC44) (MINECO/FEDER).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Inductor-Based Biosensors for Real-Time Monitoring in the Liquid Phase

  • Cantero-García, Marcos
  • Alcañiz Fillol, Miguel|||0000-0002-4579-9210
  • Pastor Navarro, Nuria
  • Noguera Murray, Patricia Silvestre|||0000-0001-7155-0710
  • Masot Peris, Rafael|||0000-0002-1114-649X
  • Hernández-Maciá, Miriam
  • Gimenez-Romero, David
[EN] Current liquid-phase resonant biosensors, such as Quartz Crystal Microbalance, Surface Acoustic Wave, or Surface Plasmon Resonance, typically rely on specialized piezoelectric substrates or complex optical setups. These requirements often necessitate cleanroom fabrication, thereby limiting cost-effective scalability. This study presents a high-integration sensing platform based on standard Printed Circuit Board (PCB) technology, incorporating an embedded inductor within a fluidic system for real-time monitoring. This design leverages industrial manufacturing standards to achieve a compact, low-cost, and scalable architecture. Detection is governed by shifts in the resonance frequency of an LC tank circuit; specifically, increases in bulk ionic strength induce a frequency decrease, whereas biomolecular adsorption at the sensor surface leads to a frequency increase. This phenomenon can be explained by the modulation of the inter-turn capacitance, which is modeled as a combination of capacitive elements accounting for contributions from the bulk electrolyte and the surface-bound dielectric layer. Such divergent responses provide an intrinsic self-discriminating capability, allowing for the analytical differentiation between surface interactions and bulk effects. To the best of our knowledge, this is the first demonstration of an inductor-based resonant sensor fully embedded in a PCB fluidic architecture for continuous liquid-phase analyte monitoring. Validated through a protein-antibody model (Bovine Serum Albumin-anti-Bovine Serum Albumin), the sensor demonstrated a limit of detection of 1.7 ppm (0.026 mM) and a linear dynamic range of 31-211 ppm (0.47-3.2 mM). These performance metrics, combined with a reproducibility of 4 +/- 3%, indicate that the platform meets the requirements for robust analytical applications. Its inherent simplicity and potential for miniaturization position this technology as a viable candidate for point-of-care diagnostics in diverse environments., This work was supported in part by the Spanish Ministry of Science and Innovation under grant PID2021-126304OB-C44 and the Spanish Ministry of Science, Innovation and Universities under grant PID2024-155683OB-C44.