Pasar al contenido principal

NANODEVICES FOR HEALTH: DIAGNOSTICS AND THERAPIES

PRE2018-084856

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de Promoción del Talento y su Empleabilidad en I+D+i
Subprograma Subprograma Estatal de Formación
Convocatoria Contratos Predoctorales
Año convocatoria 2018
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario FUNDACIÓ INSTITUT CATALÀ DE NANOCIÈNCIA I NANOTECNOLOGIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 8
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Studying ion transport dynamics in electrochemical measurements of lateral flow assays

  • Le Brun, Grégoire
  • Calucho, Enric|||0000-0002-6024-765X
  • Hauwaert, Margo
  • Moumneh, Ramy
  • Maroli, Gabriel|||0000-0001-8921-4205
  • Yunus, Sami
  • Rosati, Giulio|||0000-0002-0227-4561
  • Álvarez Diduk, Ruslan|||0000-0002-9876-1574
  • Piper, Andrew|||0000-0002-1208-8009
  • Merkoçi, Arben|||0000-0003-2486-8085
  • Raskin, Jean-Pierre
Lateral Flow Assays (LFAs) are among the most widely used biosensors. Conventional colorimetric LFAs yield binary, non-quantifiable results. Electrochemical LFAs (eLFAs) aim to overcome this limitation. However, the reported disadvantage of extreme sensitivity to experimental conditions poses a significant challenge in the development of new eLFAs. In this work, impedimetric measurements were performed to probe the impact of experimental factors such as electrolyte conductivity/ionic strength on the eLFA outcomes. The time-dependent evolution of non-Faradaic impedance measurements coupled with flow velocity computations were employed to investigate ion transport across different LFA configurations and buffer compositions. The analysis of the Péclet number, a characteristic dimensionless parameter of flow dynamics within the LFA, revealed the coexistence of diffusive and convective ionic transport regimes over the LFA operational time. In addition, our findings underscore the critical role of absorbent pad dead volume adjustments in governing the capacity to maintain sample flow within the membrane over extended durations. These electro-fluidics phenomena are essential considerations for conducting electrochemical measurements within LFAs. Overall, this study offers insights into key design parameters for the integration of electrochemistry into LFAs.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Tutorial: design and fabrication of nanoparticle-based lateral-flow immunoassays

  • Parolo, Claudio
  • Sena-Torralba, Amadeo
  • Bergua, José Francisco
  • Calucho, Enric
  • Fuentes-Chust, Celia
  • Hu, Liming
  • Rivas, Lourdes
  • Álvarez-Diduk, Ruslan
  • Nguyen, Emily P.
  • Cinti, Stefano
  • Quesada-González, Daniel
  • Merkoçi, Arben
Lateral-flow assays (LFAs) are quick, simple and cheap assays to analyze various samples at the point of care or in the field, making them one of the most widespread biosensors currently available. They have been successfully employed for the detection of a myriad of different targets (ranging from atoms up to whole cells) in all type of samples (including water, blood, foodstuff and environmental samples). Their operation relies on the capillary flow of the sample throughout a series of sequential pads, each with different functionalities aiming to generate a signal to indicate the absence/presence (and, in some cases, the concentration) of the analyte of interest. To have a user-friendly operation, their development requires the optimization of multiple, interconnected parameters that may overwhelm new developers. In this tutorial, we provide the readers with: (i) the basic knowledge to understand the principles governing an LFA and to take informed decisions during lateral flow strip design and fabrication, (ii) a roadmap for optimal LFA development independent of the specific application, (iii) a step-by-step example procedure for the assembly and operation of an LF strip for the detection of human IgG and (iv) an extensive troubleshooting section addressing the most frequent issues in designing, assembling and using LFAs. By changing only the receptors, the provided example procedure can easily be adapted for cost-efficient detection of a broad variety of targets., We acknowledge the MICROB-PREDICT project that has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 825694. Financial support from the EU Graphene Flagship Core 2 Project (No. 785219) is also acknowledged. This article reflects only the author’s view, and the European Commission is not responsible for any use that may be made of the information it contains. ICN2 is funded by the CERCA programme/Generalitat de Catalunya. The ICN2 is supported by the Severo Ochoa Centres of Excellence programme, funded by the Spanish Research Agency (AEI, grant no. SEV-2017-0706). C.P. acknowledges the Marie Skłodowska-Curie Actions Individual Fellowship; this project has received funding from the European Union’s Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement No. 795635. E.C. acknowledges Ministerio de Ciencia e Innovación of Spain and Fondo Social Europeo for the Fellowship PRE2018-084856 awarded under the call ‘Ayudas para contratos predoctorales para la formación de doctores, Subprograma Estatal de Formación del Programa Estatal de Promoción del Talento y su Empleabilidad en I+D+i’, under the framework of ‘Plan Estatal de Investigación Científica y Técnica y de Innovación 2017–2020’. E.P.N. acknowledges funding through the EU’s Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement No. 754510., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Otros (Other)

Optical smartphone-based sensing: diagnostic of biomarkers

  • Hu, Liming
  • Idili, Andrea
  • Parolo, Claudio
  • Álvarez-Diduk, Ruslan
  • Calucho, Enric
  • Merkoçi, Arben
Biomarkers are nucleic acids, peptides, proteins, lipids metabolites, or other small molecules in human tissues or biological fluids whose accurate detection contributes to the prediction and determination of diseases and their status. In recent years, platforms that allow the detection of important biomarkers at the point-of-care (PoC) are moving the field of diagnostics towards personalized medicine. In order to comply with the REASSURED criteria stated by the WHO, the most efficient solution is to integrate PoC devices with smartphones. Without a doubt the smartphone camera is a “smart detector,” and almost all the optical-based methods have been integrated, including absorbance, fluorescence, microscopic bio-imaging, surface plasmon resonance, chemiluminescence, bioluminescence, and photoluminescence. In this chapter, we explain how smartphones can be used as smart detectors in diagnostic devices and we will provide an overview of recent developments of smartphone-based optical PoC devices., A.M. acknowledge FEDER/Ministerio de Ciencia, Innovación y Universidades - Agencia Estatal de Investigación/_Project MAT2017-87202-P. A.M. also acknowledge ICN2 which is funded by the CERCA programme/Generalitat de Catalunya and supported by the Severo Ochoa Centres of Excellence programme that is funded by the Spanish Research Agency (AEI, grant no. SEV-2017-0706). A.M, L.H., A.I., C.P., R.A. and E.C. acknowledge Autonomous University of Barcelona (UAB) for their support. E.C. acknowledges Ministerio de Ciencia e Innovación of Spain and Fondo Social Europeo for the Fellowship PRE2018–084856 under the framework of “Plan Estatal de Investigación Científica y Técnica y de Innovación 2017–2020. L. H. acknowledges China Scholarship Council which is a non-profit institute affiliated with the Ministry of Education of the P. R. China. A.I. was supported by PROBIST postdoctoral fellowship funded by European Research Council (Marie Skłodowska-Curie grant agreement No. 754510)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Capacitive immunosensing at gold nanoparticle-decorated reduced graphene oxide electrodes fabricated by one-step laser nanostructuration

  • Echeverri, Danilo
  • Calucho, Enric
  • Marrugo-Ramírez, José
  • Álvarez-Diduk, Ruslan
  • Orozco, Jahir
  • Merkoçi, Arben
Nanostructured electrochemical biosensors have ushered in a new era of diagnostic precision, offering enhanced sensitivity and specificity for clinical biomarker detection. Among them, capacitive biosensing enables ultrasensitive label-free detection of multiple molecular targets. However, the complexity and cost associated with conventional fabrication methods of nanostructured platforms hinder the widespread adoption of these devices. This study introduces a capacitive biosensor that leverages laser-engraved reduced graphene oxide (rGO) electrodes decorated with gold nanoparticles (AuNPs). The fabrication involves laser-scribed GO-Au3+ films, yielding rGO-AuNP electrodes, seamlessly transferred onto a PET substrate via a press-stamping methodology. These electrodes have a remarkable affinity for biomolecular recognition after being functionalized with specific bioreceptors. For example, initial studies with human IgG antibodies confirm the detection capabilities of the biosensor using electrochemical capacitance spectroscopy. Furthermore, the biosensor can quantify CA-19-9 glycoprotein, a clinical cancer biomarker. The biosensor exhibits a dynamic range from 0 to 300 U mL−1, with a limit of detection of 8.9 U mL−1. Rigorous testing with known concentrations of a pretreated CA-19-9 antigen from human fluids confirmed their accuracy and reliability in detecting the glycoprotein. This study signifies notable progress in capacitive biosensing for clinical biomarkers, potentially leading to more accessible and cost-effective point-of-care solutions., The ICN2 is funded by the CERCA programme/Generalitat de Catalunya. The ICN2 is supported by the Severo Ochoa Centres of Excellence program, Grant CEX2021-001214-S, funded by MCIN/AEI/10.13039.501100011033. Minciencias partially funded the work through the project Cod. 111593092980. This project has received funding from the European Union's Horizon 2020 research and innovation programme under grant agreement No 881603. Views and opinions expressed are, however, those of the author(s) only and do not necessarily reflect those of the European Union. The European Union can not be held responsible for them. JO thanks support from The University of Antioquia and the Max Planck Society through the cooperation agreement 566–1, 2014. We thank The Ruta N complex for hosting the Max Planck Tandem Groups. E. Calucho acknowledges Ministerio de Ciencia e Innovación of Spain and Fondo Social Europeo for the Fellowship PRE2018-084856 awarded under the call “Ayudas para contratos predoctorales para la formación de doctores, Subprograma Estatal de Formación del Programa Estatal de Promoción del Talento y su Empleabilidad en I+D+i”, under the framework of “Plan Estatal de Investigación Científica y Técnica y de Innovación 2017–2020”. E. Calucho also acknowledges Universitat Autònoma de Barcelona (UAB) for the support and the possibility of performing this work within the framework of the Biotechnology PhD Programme., With funding from the Spanish government through the "Severo Ochoa Centre of Excellence" accreditation (CEX2021-001214-S)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Studying ion transport dynamics in electrochemical measurements of lateral flow assays

  • Le Brun, Grégoire
  • Calucho, Enric
  • Hauwaert, Margo
  • Moumneh, Ramy
  • Maroli, Gabriel
  • Yunus, Sami
  • Rosati, Giulio
  • Álvarez-Diduk, Ruslan
  • Piper, Andrew
  • Merkoçi, Arben
  • Raskin, Jean Pierre
Lateral Flow Assays (LFAs) are among the most widely used biosensors. Conventional colorimetric LFAs yield binary, non-quantifiable results. Electrochemical LFAs (eLFAs) aim to overcome this limitation. However, the reported disadvantage of extreme sensitivity to experimental conditions poses a significant challenge in the development of new eLFAs. In this work, impedimetric measurements were performed to probe the impact of experimental factors such as electrolyte conductivity/ionic strength on the eLFA outcomes. The time-dependent evolution of non-Faradaic impedance measurements coupled with flow velocity computations were employed to investigate ion transport across different LFA configurations and buffer compositions. The analysis of the Péclet number, a characteristic dimensionless parameter of flow dynamics within the LFA, revealed the coexistence of diffusive and convective ionic transport regimes over the LFA operational time. In addition, our findings underscore the critical role of absorbent pad dead volume adjustments in governing the capacity to maintain sample flow within the membrane over extended durations. These electro-fluidics phenomena are essential considerations for conducting electrochemical measurements within LFAs. Overall, this study offers insights into key design parameters for the integration of electrochemistry into LFAs., he work of G. Le Brun, M. Hauwaert and R. Moumneh was supported by the FRIA-FNRS. G. Le Brun benefited from a travel grant from Wallonie-Bruxelles International. The work of S. Yunus was supported by Région Wallonne through the Win2Wal research program. The authors thanks N. Moreau for the 3D images. G. Maroli would like to express his gratitude to the Carolina Foundation for financial support through the scholarship “Doctorado 2020.” G. Maroli acknowledges Universitat Autònoma de Barcelona (UAB) for the possibility of performing this work inside the framework of Chemistry PhD Programme. E. Calucho acknowledges Ministerio de Ciencia e Innovación of Spain and Fondo Social Europeo for the Fellowship PRE2018-084856 awarded under the call “Ayudas para contratos predoctorales para la formación de doctors, Subprograma Estatal de Formación del Programa Estatal de Promoción del Talento y su Empleabilidad en I + D + i”, under the framework of “Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020”. E. Calucho also expresses his gratitude to Universitat Autònoma de Barcelona (UAB) for the possibility of performing this work inside the framework of Biotechnology PhD Programme., Peer reviewed
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Tutorial, design and fabrication of nanoparticle-based lateral-flow immunoassays

  • Parolo, Claudio|||0000-0001-9481-4408
  • Sena-Torralba, Amadeo|||0000-0003-1340-1383
  • Bergua Canudo, José Francisco|||0000-0002-5969-193X
  • Calucho, Enric|||0000-0002-6024-765X
  • Fuentes-Chust, Celia|||0000-0002-8945-8514
  • Hu, Liming|||0000-0002-8666-9287
  • Rivas, Lourdes|||0000-0002-1510-5927
  • Álvarez Diduk, Ruslan|||0000-0002-9876-1574
  • Nguyen, Emily P.|||0000-0003-4299-2055
  • Cinti, Stefano|||0000-0002-8274-7452
  • Quesada-González, Daniel|||0000-0003-3064-2146
  • Merkoçi, Arben|||0000-0003-2486-8085
Lateral-flow assays (LFAs) are quick, simple and cheap assays to analyze various samples at the point of care or in the field, making them one of the most widespread biosensors currently available. They have been successfully employed for the detection of a myriad of different targets (ranging from atoms up to whole cells) in all type of samples (including water, blood, foodstuff and environmental samples). Their operation relies on the capillary flow of the sample throughout a series of sequential pads, each with different functionalities aiming to generate a signal to indicate the absence/presence (and, in some cases, the concentration) of the analyte of interest. To have a user-friendly operation, their development requires the optimization of multiple, interconnected parameters that may overwhelm new developers. In this tutorial, we provide the readers with: (i) the basic knowledge to understand the principles governing an LFA and to take informed decisions during lateral flow strip design and fabrication, (ii) a roadmap for optimal LFA development independent of the specific application, (iii) a step-by-step example procedure for the assembly and operation of an LF strip for the detection of human IgG and (iv) an extensive troubleshooting section addressing the most frequent issues in designing, assembling and using LFAs. By changing only the receptors, the provided example procedure can easily be adapted for cost-efficient detection of a broad variety of targets.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Selection and characterisation of bioreceptors to develop nanoparticle-based lateral-flow immunoassays in the context of the SARS-CoV-2 outbreak

  • Hu, Liming|||0000-0002-8666-9287
  • Calucho, Enric|||0000-0002-6024-765X
  • Fuentes-Chust, Celia|||0000-0002-8945-8514
  • Parolo, Claudio|||0000-0001-9481-4408
  • Idili, Andrea|||0000-0002-6004-270X
  • Álvarez Diduk, Ruslan|||0000-0002-9876-1574
  • Rivas, Lourdes|||0000-0002-1510-5927
  • Merkoçi, Arben|||0000-0003-2486-8085
This manuscript aims at raising the attention of the scientific community to the need for better characterised bioreceptors for fast development of point-of-care diagnostic devices able to support mass frequency testing. Particularly, we present the difficulties encountered in finding suitable antibodies for the development of a lateral flow assay for detecting the nucleoprotein of SARS-CoV-2.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Reduced graphene oxide electrodes meet lateral flow assays, A promising path to advanced point-of-care diagnostics

  • Calucho, Enric|||0000-0002-6024-765X
  • Álvarez Diduk, Ruslan|||0000-0002-9876-1574
  • Piper, Andrew|||0000-0002-1208-8009
  • Rossetti, Marianna|||0000-0001-5711-1287
  • Nevanen, Tarja K.
  • Merkoçi, Arben|||0000-0003-2486-8085
Research in electrochemical detection in lateral flow assays (LFAs) has gained significant momentum in recent years. The primary impetus for this surge in interest is the pursuit of achieving lower limits of detection, especially given that LFAs are the most widely employed point-of-care biosensors. Conventionally, the strategy for merging electrochemistry and LFAs has centered on the superposition of screen-printed electrodes onto nitrocellulose substrates during LFA fabrication. Nevertheless, this approach poses substantial limitations regarding scalability. In response, we have developed a novel method for the complete integration of reduced graphene oxide (rGO) electrodes into LFA strips. We employed a CO laser to concurrently reduce graphene oxide and pattern nitrocellulose, exposing its backing to create connection sites impervious to sample leakage. Subsequently, rGO and nitrocellulose were juxtaposed and introduced into a roll-to-roll system using a wax printer. The exerted pressure facilitated the transfer of rGO onto the nitrocellulose. We systematically evaluated several electrochemical strategies to harness the synergy between rGO and LFAs. While certain challenges persist, our rGO transfer technology presents compelling potential for setting a new standard in electrochemical LFA fabrication.