Pasar al contenido principal

IRON: Incremento de la Respuesta Óptica en Nanobiosensores

PTQ2018-010113

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de Promoción del Talento y su Empleabilidad en I+D+i
Subprograma Subprograma Estatal de Incorporación
Convocatoria Torres Quevedo
Año convocatoria 2018
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario PAPERDROP DIAGNOSTICS, SOCIEDAD LIMITADA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Lateral flow immunoassay for simultaneous detection of C. difficile, MRSA, and K. pneumoniae

  • Rubio-Monterde, Ana|||0000-0003-0068-9621
  • Rivas, Lourdes|||0000-0002-1510-5927
  • Gallegos, Marc
  • Quesada-González, Daniel|||0000-0003-3064-2146
  • Merkoçi, Arben|||0000-0003-2486-8085
Mainly performed within a rapid diagnostic tests company, a lateral flow (LF) system using gold nanoparticles (AuNPs) as transducers is presented able to detect three bacteria of interest, of relevance for antimicrobial resistance (AMR): Clostridioides difficile, methicillin-resistant Staphylococcus aureus (MRSA), and Klebsiella pneumoniae, with a limit of detection of 25 ng/mL of glutamate dehydrogenase (GDH) for C. difficile, 36 ng/mL of penicillin-binding protein 2a (PBP2a) for MRSA, and 4 × 10 CFU/mL for K. pneumoniae. The system showed good results with bacteria culture samples, is user-friendly, and suitable for rapid testing, as the results are obtained within 15 min.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Toward Integrated Molecular Lateral Flow Diagnostic Tests Using Advanced Micro- and Nanotechnology

  • Rubio-Monterde, Ana
  • Quesada-González, Daniel
  • Merkoçi, Arben
We acknowledge the funding received from Ministerio de Ciencia e Innovación (Madrid, Spain), which included grants PTQ2018-010113 “IRON” and DIN2018-010115 “LáMiNa”. ICN2 is funded by CERCA programme, Generalitat de Catalunya. Grant SEV-2017-0706 funded by MCIN/AEI/10.13039/501100011033. Grant PID2021-124795NB-I00 funded by MCIN/AEI/10.13039/501100011033 and by “ERDF A way of making Europe” is also acknowledged., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Lateral flow immunoassay for simultaneous detection of C. difficile, MRSA, and K. pneumoniae

  • Rubio-Monterde, Ana
  • Rivas, Lourdes
  • Gallegos, Marc
  • Quesada-González, Daniel
  • Merkoçi, Arben
Mainly performed within a rapid diagnostic tests company, a lateral flow (LF) system using gold nanoparticles (AuNPs) as transducers is presented able to detect three bacteria of interest, of relevance for antimicrobial resistance (AMR): Clostridioides difficile, methicillin-resistant Staphylococcus aureus (MRSA), and Klebsiella pneumoniae, with a limit of detection of 25 ng/mL of glutamate dehydrogenase (GDH) for C. difficile, 36 ng/mL of penicillin-binding protein 2a (PBP2a) for MRSA, and 4 × 106 CFU/mL for K. pneumoniae. The system showed good results with bacteria culture samples, is user-friendly, and suitable for rapid testing, as the results are obtained within 15 min., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature., This work is part of the ANTI-SUPERBUGS PCP project [19] that has received funding from the European Union’s Horizon 2020 Research and Innovation Programme under Grant Agreement 688878. Inside ANTI-SUPERBUGS project, we thank our BugWatcher Consortium partners, NuWave Sensors and Grupo Pulso from Evidenze group, for their support during the project. The ICN2 is funded by the CERCA programme/Generalitat de Catalunya. The ICN2 is supported by the Severo Ochoa Centres of Excellence programme, Grant CEX2021-001214-S, funded by MCIU/AEI/10.13039.501100011033. We acknowledge Departament de Recerca i Universitats of Generalitat de Catalunya for the grant 2021 SGR 01464. We also thank the funding received from Ministerio de Ciencia e Innovación (Madrid, Spain), which included grants PTQ2018-010113 “IRON” and DIN2018-010115 “LaMiNa,” and Grant PID2021-124795NB-I00 funded by MICIU/AEI/https://doi.org/10.13039/501100011033 and by “ERDF/EU.”, With funding from the Spanish government through the "Severo Ochoa Centre of Excellence" accreditation (CEX2021-001214-S)., Peer reviewed
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Toward integrated molecular lateral flow diagnostic tests using advanced micro- and Nnanotechnology

  • Rubio-Monterde, Ana|||0000-0003-0068-9621
  • Quesada-González, Daniel|||0000-0003-3064-2146
  • Merkoçi, Arben|||0000-0003-2486-8085
Introduction: Since the COVID-19 pandemic, some of the routine methods for clinical diagnosis of infectious diseases have become closer to the general population and terms like "PCR" (polymerase chain reaction) and "antigen rapid diagnostic test" (RDT) are not restricted only to the scientific community but now also commonly appear in everyday language. Given the emergency, the pandemic also raised awareness about supply politics and regulation of the market for diagnostic tests [e.g., Emergency Use Authorization (EUA) from the Food and Drug Administration (FDA); or the "Conformité Européenne" marking (CE marking) from the European Union, EU]. PCR and RDT are two major techniques currently used in clinical practice for diagnosis of diseases. On the one hand, PCR is a highly sensitive method, but it relies on expensive equipment and qualified personnel. On the other hand, rapid diagnostic tests, despite being less sensitive, are faster, cheaper, portable, and battery/instrument-free. In this review, we will discuss the advantages and disadvantages of rapid antigen tests and different nucleic acid amplification techniques (NAATs), such as PCR, both as in vitro diagnostic devices. To do so, our review explains the working principle of each method, classifies the different subtypes, and analyzes the impact that the introduction of isothermal amplification methods will have in the diagnostic field. In addition, this review gives an overview of the current available products in the market and the new trends generated as a result of combining the strengths of NAAT and RDT.