Pasar al contenido principal

GESTION ADAPTATIVA Y PROACTIVA DE LA ENFERMEDAD CRONICA MEDIANTE UNA PLATAFORMA VESTIBLE

RTI2018-095324-B-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2018
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario FUNDACION UNIVERSITARIA SAN PABLO CEU

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
Publicación Artículo científico (JournalArticle)

Positive and Negative Evidence Accumulation Clustering for Sensor Fusion: An Application to Heartbeat Clustering

  • Márquez, David G.
  • Félix Lamas, Paulo
  • García, Constantino A.
  • Tejedor, Javier
  • Fred, Ana L. N.
  • Otero, Abraham
In this work, a new clustering algorithm especially geared towards merging data arising from multiple sensors is presented. The algorithm, called PN-EAC, is based on the ensemble clustering paradigm and it introduces the novel concept of negative evidence. PN-EAC combines both positive evidence, to gather information about the elements that should be grouped together in the final partition, and negative evidence, which has information about the elements that should not be grouped together. The algorithm has been validated in the electrocardiographic domain for heartbeat clustering, extracting positive evidence from the heartbeat morphology and negative evidence from the distances between heartbeats. The best result obtained on the MIT-BIH Arrhythmia database yielded an error of 1.44%. In the St. Petersburg Institute of Cardiological Technics 12-Lead Arrhythmia Database database (INCARTDB), an error of 0.601% was obtained when using two electrocardiogram (ECG) leads. When increasing the number of leads to 4, 6, 8, 10 and 12, the algorithm obtains better results (statistically significant) than with the previous number of leads, reaching an error of 0.338%. To the best of our knowledge, this is the first clustering algorithm that is able to process simultaneously any number of ECG leads. Our results support the use of PN-EAC to combine different sources of information and the value of the negative evidence
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

A multi-poosition approach in a smart fiber-optic surveillance system for pipeline integrity threat detection

  • Tejedor, Javier
  • Macías-Guarasa, Javier
  • Martins, Hugo F.
  • Martín-López, Sonia
  • González-Herráez, Miguel
19 pags., 4 figs., 9 tabs. -- This article belongs to the Special Issue Pattern Recognition and Applications, We present a new pipeline integrity surveillance system for long gas pipeline threat detection and classification. The system is based on distributed acoustic sensing with phase-sensitive optical time domain reflectometry (ϕ-OTDR) and pattern recognition for event classification. The proposal incorporates a multi-position approach in a Gaussian Mixture Model (GMM)-based pattern classification system which operates in a real-field scenario with a thorough experimental procedure. The objective is exploiting the availability of vibration-related data at positions nearby the one actually producing the main disturbance to improve the robustness of the trained models. The system integrates two classification tasks: (1) machine + activity identification, which identifies the machine that is working over the pipeline along with the activity being carried out, and (2) threat detection, which aims to detect suspicious threats for the pipeline integrity (independently of the activity being carried out). For the machine + activity identification mode, the multi-position approach for model training obtains better performance than the previously presented single-position approach for activities that show consistent behavior and high energy (between 6% and 11% absolute) with an overall increase of 3% absolute in the classification accuracy. For the threat detection mode, the proposed approach gets an 8% absolute reduction in the false alarm rate with an overall increase of 4.5% absolute in the classification accuracy., This research was funded by a private research project by Fluxys, Gassco and Statoil named “PIT-STOP (Early detection of Pipeline Integrity Threats using a SmarT fiber-OPtic surveillance system)”, by the Spanish Ministry of Economy and Competitiveness under projects HEIMDALUAH (TIN2016-75982-C2-1-R) and ARTEMISA (TIN2016-80939-R), by the University of Alcalá under projects ACUFANO (CCG19/IA-024) and ARGOS (CCG20/IA-043), and by the Spanish Ministry of Science, Innovation and Universities (IJCI-2017-33856 and RTI2018-097957-B-C33). The APC was funded by the Ministry of Science, Innovation and Universities of Spain grant number RTI2018-095324-B-I00., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

A multi-position approach in a smart fiber-optic surveillance system for pipeline integrity threat detection

  • Tejedor, Javier
  • Macías-Guarasa, Javier
  • Martins, Hugo F.
  • Martín-López, Sonia
  • González-Herráez, Miguel
19 pags., 4 figs., 9 tabs. -- This article belongs to the Special Issue Pattern Recognition and Applications, We present a new pipeline integrity surveillance system for long gas pipeline threat detection and classification. The system is based on distributed acoustic sensing with phase-sensitive optical time domain reflectometry (ϕ-OTDR) and pattern recognition for event classification. The proposal incorporates a multi-position approach in a Gaussian Mixture Model (GMM)-based pattern classification system which operates in a real-field scenario with a thorough experimental procedure. The objective is exploiting the availability of vibration-related data at positions nearby the one actually producing the main disturbance to improve the robustness of the trained models. The system integrates two classification tasks: (1) machine + activity identification, which identifies the machine that is working over the pipeline along with the activity being carried out, and (2) threat detection, which aims to detect suspicious threats for the pipeline integrity (independently of the activity being carried out). For the machine + activity identification mode, the multi-position approach for model training obtains better performance than the previously presented single-position approach for activities that show consistent behavior and high energy (between 6% and 11% absolute) with an overall increase of 3% absolute in the classification accuracy. For the threat detection mode, the proposed approach gets an 8% absolute reduction in the false alarm rate with an overall increase of 4.5% absolute in the classification accuracy., This research was funded by a private research project by Fluxys, Gassco and Statoil named “PIT-STOP (Early detection of Pipeline Integrity Threats using a SmarT fiber-OPtic surveillance system)”, by the Spanish Ministry of Economy and Competitiveness under projects HEIMDALUAH (TIN2016-75982-C2-1-R) and ARTEMISA (TIN2016-80939-R), by the University of Alcalá under projects ACUFANO (CCG19/IA-024) and ARGOS (CCG20/IA-043), and by the Spanish Ministry of Science, Innovation and Universities (IJCI-2017-33856 and RTI2018-097957-B-C33). The APC was funded by the Ministry of Science, Innovation and Universities of Spain grant number RTI2018- 095324-B-I00.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

A hybrid cascade-parallel discriminative-generative model for pipeline integrity threat detection in a smart fiber optic surveillance system

  • Tejedor, Javier
  • Macias-Guarasa, Javier
  • Martins, Hugo F.
  • Martín-López, Sonia
  • González-Herráez, Miguel
25 pags., 10 figs., 8 tabs., This paper presents an advanced system for the continuous monitoring of potential threats in a long gas pipeline. For signal acquisition, phase-sensitive optical time domain reflectometry (ϕ-OTDR) technology is employed. Then, pattern recognition strategies are incorporated, which are aimed at identifying threats. To do so, the system integrates a random forest-based approach on top of a multiple-layer perceptron (MLP)-based discriminative approach for feature extraction within a parallel Gaussian Mixture Model (GMM)-Hidden Markov Model (HMM) for pattern classification in a hybrid approach. Subsequently, a system combination strategy, which makes use of the decisions carried out by this hybrid approach, is also presented. This strategy is based on the so-called majority voting technique, which makes use of the output of the classification step from the different feature extraction strategies and the different number of states in the GMM-HMM-based classification. The system is tested on two tasks: (1) Identification of machine and activity, and (2) detection of threats for the pipeline. Compared with our previous system, the results of this advanced system show that the hybrid feature extraction and pattern classification achieve statistically significant improvements for both tasks (i.e., 5% of relative improvement for the machine and activity identification task, 1% of relative improvement in the threat detection rate, and 15% of relative improvement in the false alarm rate for the threat detection task)., This work was partially supported by the Ministry of Science, Innovation and Universities of Spain (grant number RTI2018-095324-B-I00).This work was also funded by the Spanish Ministry of Economy and Competitiveness with projects ARTEMISA (TIN2016-80939-R) and HEIMDAL-UAH (TIN201675982-C2-1-R), by the Spanish Ministry of Science and Innovation MCIN/AEI/10.13039/501100011033 and by the European Union NextGenerationEU/PRTR program, with projects PSI (PLEC2021-007875),ATHENA (PID2020-115995RB-I00) and EYEFUL (PID2020-113118RB-C31), and by CAM and UAH under projects ARGOS+ (PIUAH21/IA-016) and CONDORDIA (CM/JIN/2021-015). The authors gratefully acknowledge the computer resources at Artemisa, funded by the European Union ERDF and Comunitat Valenciana as well as the technical support provided by the Instituto de Fisica Corpuscular, IFIC (CSIC-UV). The authors thank Sira E. Palazuelos-Cagigas for her participation in the writing and technical editing of the manuscript., Peer reviewed
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

A multi-position approach in a smart fiber-optic surveillance system for pipeline integrity threat detection

  • Tejedor Noguerales, Javier
  • Macías Guarasa, Javier|||0000-0002-3303-3963
  • Fidalgo Martins, Hugo|||0000-0003-3927-8125
  • Martín López, Sonia|||0000-0001-5203-6206
  • González Herráez, Miguel|||0000-0003-2555-2971
We present a new pipeline integrity surveillance system for long gas pipeline threat detection and classification. The system is based on distributed acoustic sensing with phase-sensitive optical time domain reflectometry (?-OTDR) and pattern recognition for event classification. The proposal incorporates a multi-position approach in a Gaussian Mixture Model (GMM)-based pattern classification system which operates in a real-field scenario with a thorough experimental procedure. The objective is exploiting the availability of vibration-related data at positions nearby the one actually producing the main disturbance to improve the robustness of the trained models. The system integrates two classification tasks: (1) machine + activity identification, which identifies the machine that is working over the pipeline along with the activity being carried out, and (2) threat detection, which aims to detect suspicious threats for the pipeline integrity (independently of the activity being carried out). For the machine + activity identification mode, the multi-position approach for model training obtains better performance than the previously presented single-position approach for activities that show consistent behavior and high energy (between 6% and 11% absolute) with an overall increase of 3% absolute in the classification accuracy. For the threat detection mode, the proposed approach gets an 8% absolute reduction in the false alarm rate with an overall increase of 4.5% absolute in the classification accuracy., Ministerio de Economía y Competitividad, Agencia Estatal de Investigación, Universidad de Alcalá, Ministerio de Ciencia e Innovación