Pasar al contenido principal

DESARROLLO DE UN EXOESQUELETO PASIVO PARA REHABILITACION Y EVALUACION DE LA TERAPIA DE MIEMBRO SUPERIOR EN PARALISIS CEREBRAL

RTI2018-097122-A-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2018
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario FUNDACION UNIVERSITARIA SAN PABLO CEU

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Rediseño basado en la experiencia clínica de un andador robótico para la rehabilitación de fractura de cadera, Redesign based on clinical experience of a robotic walker for hip fracture rehabilitation

  • Costa, Vanina
  • Sánchez, Cristina
  • Perea, Luis
  • Rocon, Eduardo
  • Otero, Abraham
  • Raya, Rafael
[ES] La fractura de cadera es una lesión frecuente en personas mayores de 65 años,estando asociada a una reducción en la esperanza de vida. Su rehabilitación se basa en la movilización gradual mediante terapia manual. Sin embargo, estos tratamientos no suelen ser integrales, constan de ejercicios repetitivos, resultan monótonos para el pacientey su seguimientoes principalmente cualitativo.  SWalker es un andador robótico basado en un sistema de tracción y de soporte de peso, que integra sensores de marcha. Con una primera versión de este andador se llevó a cabo un estudio clínico que involucró 34 pacientes. A partir de esta experiencia se han extraído los requisitos de diseño que se consideran claves para el desarrollo de este tipo de dispositivos. Sobre la base de estos requisitos se ha construido una segunda versión del andador en la que se ha validado su usabilidad con 5 pacientes. Empleando la escala QUEST 2.0 se han comparado ambas versiones del andador, mostrando mejoras en la segunda versión en seguridad, adaptabilidad y usabilidad, [EN] Hip fracture is a common injury in people over 65 years old, linked to a reduction in life expectancy. Rehabilitation is based on gradual mobilization through manual therapy. However, these treatments are not usually integrative, they consist of repetitive exercises that are not motivating for the patient and their follow-up is mainly qualitative. SWalker is a robotic platform based on a traction and weight-bearing system that integrates gait sensors. A clinical study involving 34 patients was conducted with a first version of this walker. From this experience, the key design requirements for the development of this type of device were gathered. Based on these requirements, a second version of the walker was built and its usability was validated with 5 patients. Using the QUEST 2.0 scale, both versions of the walker were compared, showing improvements in safety, adaptability, and usability in the second version., Los autores agradecen al Grupo Albertia su colaboración en este proyecto y al equipo de Josman Soluciones Técnicas por su contribución en el rediseño y fabricación del dispositivo. Este trabajo fue financiado por el Centro para el Desarrollo Tecnológico Industrial (CDTI) del Ministerio de Ciencia e Innovación, Gobierno de España bajo el proyecto SWALKERS17 concedido en 2018 y el proyecto de referencia IDI-20220400 (SWALKERS II) concedido en 2021.También por el Gobierno de España (Proyectos RTI2018-097122-A-I00 y PID2019-105110RB-C31, financiados por FEDER/Ministerio de Ciencia e Innovación/AEI)
Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
Publicación Artículo científico (JournalArticle)

Positive and Negative Evidence Accumulation Clustering for Sensor Fusion: An Application to Heartbeat Clustering

  • Márquez, David G.
  • Félix Lamas, Paulo
  • García, Constantino A.
  • Tejedor, Javier
  • Fred, Ana L. N.
  • Otero, Abraham
In this work, a new clustering algorithm especially geared towards merging data arising from multiple sensors is presented. The algorithm, called PN-EAC, is based on the ensemble clustering paradigm and it introduces the novel concept of negative evidence. PN-EAC combines both positive evidence, to gather information about the elements that should be grouped together in the final partition, and negative evidence, which has information about the elements that should not be grouped together. The algorithm has been validated in the electrocardiographic domain for heartbeat clustering, extracting positive evidence from the heartbeat morphology and negative evidence from the distances between heartbeats. The best result obtained on the MIT-BIH Arrhythmia database yielded an error of 1.44%. In the St. Petersburg Institute of Cardiological Technics 12-Lead Arrhythmia Database database (INCARTDB), an error of 0.601% was obtained when using two electrocardiogram (ECG) leads. When increasing the number of leads to 4, 6, 8, 10 and 12, the algorithm obtains better results (statistically significant) than with the previous number of leads, reaching an error of 0.338%. To the best of our knowledge, this is the first clustering algorithm that is able to process simultaneously any number of ECG leads. Our results support the use of PN-EAC to combine different sources of information and the value of the negative evidence
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Accuracy study of the Oculus Touch v2 versus inertial sensor for a single-axis rotation simulating the elbow’s range of motion

  • Rojo, Ana
  • Cortina, J.
  • Sánchez, C.
  • Urendes, Eloy José
  • García-Carmona, Rodrigo
  • Raya, Rafael
Virtual reality (VR) has emerged as a valid addition to conventional therapy in rehabilitation and sports medicine. This has enabled the development of novel and affordable rehabilitation strategies. However, before VR devices can be used in these situations, they must accurately capture the range of motion of the body-segment where they are mounted. This study aims to state the accuracy of the Oculus Touch v2 controller when used to measure the elbow’s motion in the sagittal plane. The controller is benchmarked against an inertial sensor (ENLAZA), which has already been validated as a reliable measurement device. We have developed a virtual environment that matches both the Oculus Touch v2 and the inertial sensor orientations using a digital goniometer. We have also collected the orientation measurements given by each system for a set of 17 static angles that cover the full range of normal elbow flexion and hyperextension motion, in 10° intervals from − 10° (hyperextension) to 150° (flexion). We have applied the intra-rater reliability test to assess the level of agreement between the measurements of these devices, obtaining a value of 0.999, with a 95% confidence interval ranged from 0.996 to 1.000. By analyzing the angle measurement outcomes, we have found that the accuracy degrades at flexion values between 70° and 110°, peaking at 90°. The accuracy of Oculus Touch v2 when used to capture the elbow’s flexion motion is good enough for the development of VR rehabilitation applications based on it. However, the flaws in the accuracy that have been revealed in this experimental study must be considered when designing such applications., This research was funded by the SPANISH GOVERNMENT (FEDER/Ministry of Science and Innovation/AEI.), Grant Number RTI2018-097122-A-I00.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

FarmDay: A Gamified Virtual Reality Neurorehabilitation Application for Upper Limb Based on Activities of Daily Living

  • Rojo, Ana
  • Santos-Paz, J.Á.
  • Raya, Rafael
  • García-Carmona, Rodrigo
Patients with upper limb disorders are limited in their activities of daily living and impose an important healthcare burden due to the repetitive rehabilitation they require. A way to reduce this burden is through home-based therapy using virtual reality solutions, since they are readily available, provide immersion, and enable accurate motion tracking, and custom applications can be developed for them. However, there is lack of guidelines for the design of effective VR rehabilitation applications in the literature, particularly for bimanual training. This work introduces a VR telerehabilitation system that uses off-the-shelf hardware, a real-time remote setup, and a bimanual training application that aims to improve upper extremity motor function. It is made of six activities and was evaluated by five physiotherapists specialised in (2) neuromotor disorders and (3) functional rehabilitation and occupational therapy. A descriptive analysis of the results obtained from the System Usability Scale test of the application and a collection of qualitative assessments of each game have been carried out. The application obtained a mean score of 86.25 (±8.96 SD) in the System Usability Scale, and the experts concluded that it accurately reproduces activities of daily living movements except for wrist and finger movements. They also offer a set of design guidelines., The study was funded by the Spanish Ministry of Science, Innovation and University, under the grant European Regional Development Fund (ERDF) with project reference IDI-20191120, and also by the SPANISH GOVERNMENT (FEDER/Ministry of Science and Innovation/AEI), grant number RTI2018-097122-A-I00.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

FarmDay: A Gamified Virtual Reality Neurorehabilitation Application for Upper Limb Based on Activities of Daily Living

  • Rojo, Ana
  • Santos-Paz, J.Á.
  • Raya, Rafael
  • García-Carmona, Rodrigo
Patients with upper limb disorders are limited in their activities of daily living and impose an important healthcare burden due to the repetitive rehabilitation they require. A way to reduce this burden is through home-based therapy using virtual reality solutions, since they are readily available, provide immersion, and enable accurate motion tracking, and custom applications can be developed for them. However, there is lack of guidelines for the design of effective VR rehabilitation applications in the literature, particularly for bimanual training. This work introduces a VR telerehabilitation system that uses off-the-shelf hardware, a real-time remote setup, and a bimanual training application that aims to improve upper extremity motor function. It is made of six activities and was evaluated by five physiotherapists specialised in (2) neuromotor disorders and (3) functional rehabilitation and occupational therapy. A descriptive analysis of the results obtained from the System Usability Scale test of the application and a collection of qualitative assessments of each game have been carried out. The application obtained a mean score of 86.25 (±8.96 SD) in the System Usability Scale, and the experts concluded that it accurately reproduces activities of daily living movements except for wrist and finger movements. They also offer a set of design guidelines., The study was funded by the Spanish Ministry of Science, Innovation and University, under the grant European Regional Development Fund (ERDF) with project reference IDI-20191120, and also by the SPANISH GOVERNMENT (FEDER/Ministry of Science and Innovation/AEI), grant number RTI2018-097122-A-I00.