Pasar al contenido principal

ESTABILIDAD DE REDES MVDC INTEGRANDO TECNOLOGIAS DE ENERGIAS RENOVABLES, ALMACENAMIENTO DE ENERGIA Y CONVERTIDORES DE FUENTE DE IMPEDANCIA

RTI2018-095720-B-C33

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2018
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSITAT POLITECNICA DE CATALUNYA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 13
Encontrada(s) 1 página(s)

RODIN. Repositorio de Objetos de Docencia e Investigación de la Universidad de Cádiz
Publicación Artículo científico (JournalArticle)

Real-Time Implementation of qZSC for MVDC to Microgrids Link

  • Martínez-Figueroa, G. de J.
  • Bogarra, Santiago
  • Córcoles, Felipe
  • Sainz, Luis
  • Fernández Ramírez, Luis Miguel
  • Sarrias Mena, Raúl
Nowadays, power systems require new solutions to integrate renewable energies. In this paper, microgrids linked to MVDC are proposed through quasi-impedance-source converters to improve system reliability. Several prototypes are implemented using real-time platforms to analyze the system behavior, but the real-time implementation of the shoot-through state of the qZSC requires a very low time-step and sample time, which is not easy to achieve. The results obtained with these prototypes are included. Finally, a satisfactory solution is presented, implementing the power system in Typhoon HIL-402, the qZSC control in dSPACE MicroLabBox, and generating the gate signals in the FPGA included in the MicroLabBox platform. © 2022, European Association for the Development of Renewable Energy, Environment and Power Quality (EA4EPQ). All rights reserved.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

State-space model of quasi-z-source inverter-PV systems for transient dynamics studies and network stability assessment

  • Monjo Mur, Lluís|||0000-0001-6106-097X
  • Sainz Sapera, Luis|||0000-0002-5670-0669
  • Mesas García, Juan José|||0000-0002-4014-4258
  • Pedra Durán, Joaquim|||0000-0003-2890-8160
Photovoltaic (PV) power systems are increasingly being used as renewable power generation sources. Quasi-Z-source inverters (qZSI) are a recent, high-potential technology that can be used to integrate PV power systems into AC networks. Simultaneously, concerns regarding the stability of PV power systems are increasing. Converters reduce the damping of grid-connected converter systems, leading to instability. Several studies have analyzed the stability and dynamics of qZSI, although the characterization of qZSI-PV system dynamics in order to study transient interactions and stability has not yet been properly completed. This paper contributes a small-signal, state-space-averaged model of qZSI-PV systems in order to study these issues. The model is also applied to investigate the stability of PV power systems by analyzing the influence of system parameters. Moreover, solutions to mitigate the instabilities are proposed and the stability is verified using PSCAD time domain simulations., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

A parametric approach for the study of three-phase inverters subject to grid faults

  • Rolán Blanco, Alejandro|||0000-0002-9855-6933
  • Sainz Sapera, Luis|||0000-0002-5670-0669
The aim of this work is to describe the behavior of three-phase inverters connected to a faulty grid by means of a parametric approach which gives rise to limaçon of Pascal curves and 3D figures formed by the injected currents during the fault. The analytical study is given in the complex form of the transformed Park variables, and the simulation results are obtained by means of MATLAB. The results show that the parametric analysis can be an easy and useful tool to predict the behavior of three-phase inverters operating under voltage sags, with the aim of achieving fault ride-through (FRT) capability., Objectius de Desenvolupament Sostenible::11 - Ciutats i Comunitats Sostenibles, Objectius de Desenvolupament Sostenible::7 - Energia Assequible i No Contaminant
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Open-circuit fault diagnosis and maintenance in multi-pulse parallel and series TRU topologies

  • Saura Perisé, Jaime|||0000-0002-6904-2781
  • Bakkar, Mostafa|||0000-0001-6913-2472
  • Bogarra Rodríguez, Santiago|||0000-0002-2006-1156
©2020 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., Transformer Rectifier Units (TRUs) are a reliable way for DC generation in several electric applications. These units are formed by multiple three-phase uncontrolled bridge rectifiers connected according to two main topologies (parallel and series), and fed by a phase-shifting transformer, which can have different configurations. Fault diagnosis of the uncontrolled bridge rectifier diodes is one of the most important concerns on the electronic devices, nonetheless, rectifier units are inherently not protected in front of Open-Circuit (O/C) faults, which cause malfunction and performance deterioration. In order to solve this drawback, the proposed fault diagnosis method is based on the O/C fault signature observed in the DC-link output voltage of TRUs rectifier. It allows detecting the O/C diodes of parallel and series TRUs with different phase-shifting transformer configurations and for the most usual fault scenarios. Moreover, it also helps the prediction of diodes that could be exposed to failure after the fault, which provides corrective maintenance for the TRU development. The proposed method is illustrated from MATLABTM numerical simulations of a 12-pulse TRU, and is validated with experimental tests., This work supported in part by the Research Project Estabilidad de Redes MVdc Integrando Tecnologias de Energias Renovables, Almacenamiento de Energia y Convertidores de Fuente de Impedancia, RTI2018-095720-B-C33, in part by the Ministerio de Ciencia, Innovación y Universidades, and in part by the European Union., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

New methodology to calculate DC voltage signature in n-phases TRUs under supply voltage sags

  • Saura Perisé, Jaime|||0000-0002-6904-2781
  • Bakkar, Mostafa|||0000-0001-6913-2472
  • Bogarra Rodríguez, Santiago|||0000-0002-2006-1156
A new methodology based on the shadow projection has been developed to study any multipulse rectifier's dynamic behavior under balanced and unbalanced conditions. The proposed methodology calculates the DC average voltage and instantaneous values under balanced and unbalanced supply voltage conditions for multiphase Transformer Rectifier Units (TRUs). The calculation of the developed algorithms is more practical than the classical methods and other approaches based on Fourier series or symmetrical components that are difficult to apply under unbalanced conditions. Furthermore, classical methods are not simple to determine the limits of the integrals and calculate them to obtain the average value, so a more friendly and practical methodology has been developed to analyze rectifiers operating under supply voltage sags. This new methodology has been validated by simulation for a 12-pulse TRU in series and parallel connections, and it has also been validated for a 36-pulse TRU in parallel connection using interphase inductors. The accuracy of the calculations is validated by the experimental results for 12-pulse TRUs, series, and parallel connection, and 18-pulse TRU in series connection., This work was supported by the research project ‘‘Estabilidad de redes MVDC integrando tecnologías de energías renovables, almacenamiento de energía y convertidores de fuente de impedancia,’’ by the Ministerio de Ciencia, Innovación y Universidades and European Union, under Grant RTI2018-095720-B-C33., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Frequency domain stability assessment of photovoltaic power generation systems with quasi-z-source inverters

  • Sainz Sapera, Luis|||0000-0002-5670-0669
  • Monjo Mur, Lluís|||0000-0001-6106-097X
Photovoltaic power generation systems are one of the main renewable power sources, and quasi-Z-source inverters are becoming powerful devices to integrate these systems in AC grids. However, stability issues due to the damping behaviour of converters must be considered. There are several studies in this direction but instability concerns are not completely solved yet. This paper contributes with a procedure for the stability assessment of photovoltaic power generation systems with quasiZ-source inverters in the frequency domain. The study is based on the small-signal averaged model of the system expressed in the s-domain and the stability criterion derived from the frequency characteristics of the state-space matrix. The influence of the photovoltaic power generation system operating point on stability is studied by the proposed procedure. Eigenvalue analysis and PSCAD/EMTDC simulations are also performed to validate the obtained results., Peer Reviewed, Objectius de Desenvolupament Sostenible::7 - Energia Assequible i No Contaminant
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Average value of the DC-link output voltage in multi-phase uncontrolled bridge rectifiers under supply voltage balance and unbalance conditions

  • Saura Perisé, Jaime|||0000-0002-6904-2781
  • Mesas García, Juan José|||0000-0002-4014-4258
  • Sainz Sapera, Luis|||0000-0002-5670-0669
Average value of the DC-link output voltage is a variable of interest in multi-phase uncontrolled bridge rectifiers. The aim of this paper is to present a new, effort-saving procedure capable of providing an accurate value of this variable, a value which can be later corrected considering the usually omitted voltage drops. The proposed method, based on the Cauchy’s formula (1841), allows the limitations of the existing methods to be overcome and can be used under supply voltage balance and unbalance conditions. Time-domain simulations and experimental tests were conducted to show the usefulness of the method and validate its accuracy. Under supply voltage balance conditions, the new method allows results as accurate as those provided by analytical expressions available in the literature or time-domain simulations performed by any software to be obtained. Moreover, under supply voltage unbalance conditions, this method outperforms analytical expressions available in the literature and at least equals time-domain simulations performed by any software in terms of accuracy of the obtained results. Therefore, under supply voltage balance and unbalance conditions, the proposed method makes the mathematical effort required to elaborate analytical expressions or the computational effort required to perform time-domain simulations unnecessary. In addition, the new method provides suitable estimates of values experimentally determined., This work was supported in part by the Ministerio de Ciencia, Innovación y Universidades under Grant RTI2018-095720-B-C33., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

New methodology to calculate DC voltage signature in n-phases TRUs under supply voltage sags

  • Saura Perisé, Jaime
  • Bakkar, Mostafa
  • Bogarra Rodríguez, Santiago
A new methodology based on the shadow projection has been developed to study any multipulse rectifier's dynamic behavior under balanced and unbalanced conditions. The proposed methodology calculates the DC average voltage and instantaneous values under balanced and unbalanced supply voltage conditions for multiphase Transformer Rectifier Units (TRUs). The calculation of the developed algorithms is more practical than the classical methods and other approaches based on Fourier series or symmetrical components that are difficult to apply under unbalanced conditions. Furthermore, classical methods are not simple to determine the limits of the integrals and calculate them to obtain the average value, so a more friendly and practical methodology has been developed to analyze rectifiers operating under supply voltage sags. This new methodology has been validated by simulation for a 12-pulse TRU in series and parallel connections, and it has also been validated for a 36-pulse TRU in parallel connection using interphase inductors. The accuracy of the calculations is validated by the experimental results for 12-pulse TRUs, series, and parallel connection, and 18-pulse TRU in series connection., This work was supported by the research project ‘‘Estabilidad de redes MVDC integrando tecnologías de energías renovables, almacenamiento de energía y convertidores de fuente de impedancia,’’ by the Ministerio de Ciencia, Innovación y Universidades and European Union, under Grant RTI2018-095720-B-C33., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Frequency domain stability assessment of photovoltaic power generation systems with quasi-z-source inverters

  • Sainz Sapera, Luis
  • Monjo Mur, Lluís
Photovoltaic power generation systems are one of the main renewable power sources, and quasi-Z-source inverters are becoming powerful devices to integrate these systems in AC grids. However, stability issues due to the damping behaviour of converters must be considered. There are several studies in this direction but instability concerns are not completely solved yet. This paper contributes with a procedure for the stability assessment of photovoltaic power generation systems with quasiZ-source inverters in the frequency domain. The study is based on the small-signal averaged model of the system expressed in the s-domain and the stability criterion derived from the frequency characteristics of the state-space matrix. The influence of the photovoltaic power generation system operating point on stability is studied by the proposed procedure. Eigenvalue analysis and PSCAD/EMTDC simulations are also performed to validate the obtained results., Peer Reviewed, Objectius de Desenvolupament Sostenible::7 - Energia Assequible i No Contaminant, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

State-space model of quasi-z-source inverter-PV systems for transient dynamics studies and network stability assessment

  • Monjo Mur, Lluís
  • Sainz Sapera, Luis
  • Mesas García, Juan José
  • Pedra Durán, Joaquim
Photovoltaic (PV) power systems are increasingly being used as renewable power generation sources. Quasi-Z-source inverters (qZSI) are a recent, high-potential technology that can be used to integrate PV power systems into AC networks. Simultaneously, concerns regarding the stability of PV power systems are increasing. Converters reduce the damping of grid-connected converter systems, leading to instability. Several studies have analyzed the stability and dynamics of qZSI, although the characterization of qZSI-PV system dynamics in order to study transient interactions and stability has not yet been properly completed. This paper contributes a small-signal, state-space-averaged model of qZSI-PV systems in order to study these issues. The model is also applied to investigate the stability of PV power systems by analyzing the influence of system parameters. Moreover, solutions to mitigate the instabilities are proposed and the stability is verified using PSCAD time domain simulations., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Average value of the DC-link output voltage in multi-phase uncontrolled bridge rectifiers under supply voltage balance and unbalance conditions

  • Saura Perisé, Jaime
  • Mesas García, Juan José
  • Sainz Sapera, Luis
Average value of the DC-link output voltage is a variable of interest in multi-phase uncontrolled bridge rectifiers. The aim of this paper is to present a new, effort-saving procedure capable of providing an accurate value of this variable, a value which can be later corrected considering the usually omitted voltage drops. The proposed method, based on the Cauchy’s formula (1841), allows the limitations of the existing methods to be overcome and can be used under supply voltage balance and unbalance conditions. Time-domain simulations and experimental tests were conducted to show the usefulness of the method and validate its accuracy. Under supply voltage balance conditions, the new method allows results as accurate as those provided by analytical expressions available in the literature or time-domain simulations performed by any software to be obtained. Moreover, under supply voltage unbalance conditions, this method outperforms analytical expressions available in the literature and at least equals time-domain simulations performed by any software in terms of accuracy of the obtained results. Therefore, under supply voltage balance and unbalance conditions, the proposed method makes the mathematical effort required to elaborate analytical expressions or the computational effort required to perform time-domain simulations unnecessary. In addition, the new method provides suitable estimates of values experimentally determined., This work was supported in part by the Ministerio de Ciencia, Innovación y Universidades under Grant RTI2018-095720-B-C33., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

A parametric approach for the study of three-phase inverters subject to grid faults

  • Rolán Blanco, Alejandro
  • Sainz Sapera, Luis
The aim of this work is to describe the behavior of three-phase inverters connected to a faulty grid by means of a parametric approach which gives rise to limaçon of Pascal curves and 3D figures formed by the injected currents during the fault. The analytical study is given in the complex form of the transformed Park variables, and the simulation results are obtained by means of MATLAB. The results show that the parametric analysis can be an easy and useful tool to predict the behavior of three-phase inverters operating under voltage sags, with the aim of achieving fault ride-through (FRT) capability., Objectius de Desenvolupament Sostenible::11 - Ciutats i Comunitats Sostenibles, Objectius de Desenvolupament Sostenible::7 - Energia Assequible i No Contaminant, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Open-circuit fault diagnosis and maintenance in multi-pulse parallel and series TRU topologies

  • Saura Perisé, Jaime
  • Bakkar, Mostafa
  • Bogarra Rodríguez, Santiago
©2020 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., Transformer Rectifier Units (TRUs) are a reliable way for DC generation in several electric applications. These units are formed by multiple three-phase uncontrolled bridge rectifiers connected according to two main topologies (parallel and series), and fed by a phase-shifting transformer, which can have different configurations. Fault diagnosis of the uncontrolled bridge rectifier diodes is one of the most important concerns on the electronic devices, nonetheless, rectifier units are inherently not protected in front of Open-Circuit (O/C) faults, which cause malfunction and performance deterioration. In order to solve this drawback, the proposed fault diagnosis method is based on the O/C fault signature observed in the DC-link output voltage of TRUs rectifier. It allows detecting the O/C diodes of parallel and series TRUs with different phase-shifting transformer configurations and for the most usual fault scenarios. Moreover, it also helps the prediction of diodes that could be exposed to failure after the fault, which provides corrective maintenance for the TRU development. The proposed method is illustrated from MATLABTM numerical simulations of a 12-pulse TRU, and is validated with experimental tests., This work supported in part by the Research Project Estabilidad de Redes MVdc Integrando Tecnologias de Energias Renovables, Almacenamiento de Energia y Convertidores de Fuente de Impedancia, RTI2018-095720-B-C33, in part by the Ministerio de Ciencia, Innovación y Universidades, and in part by the European Union., Peer Reviewed, Postprint (author's final draft)