Pasar al contenido principal

METROLOGIA POR FUSION DE DATOS MULTIESCALA PARA LA CARACTERIZACION DE PIEZAS COMPLEJAS

RTI2018-097191-B-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2018
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD DE ZARAGOZA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

2D positioning control system for the planar motion of a nanopositioning platform

  • Díaz-Pérez, Lucía
  • Torralba, Marta
  • Albajez, José Antonio
  • Yagüe-Fabra, José Antonio
A novel nanopositioning platform (referred as NanoPla) in development has been designed to achieve nanometre resolution in a large working range of 50 mm × 50 mm. Two-dimensional (2D) movement is performed by four custom-made Halbach linear motors, and a 2D laser system provides positioning feedback, while the moving part of the platform is levitating and unguided. For control hardware, this work proposes the use of a commercial generic solution, in contrast to other systems where the control hardware and software are specifically designed for that purpose. In a previous paper based on this research, the control system of one linear motor implemented in selected commercial hardware was presented. In this study, the developed control system is extended to the four motors of the nanopositioning platform to generate 2D planar movement in the whole working range of the nanopositioning platform. In addition, the positioning uncertainty of the control system is assessed. The obtained results satisfy the working requirements of the NanoPla, achieving a positioning uncertainty of ±0.5 µm along the whole working range.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Assessment of gradient-based algorithm for surface determination in multi-material gap measurements by x ray computed tomography

  • Jiménez Pacheco, R.
  • Ontiveros, S.
  • Yagüe Fabra, J. A
  • Zanini, F.
  • Carmignato, S.
  • Albajez, J.A.
XX-ray computed tomography is one of the most promising measurement techniques for the dimensional evaluation of industrial components. However, the inherent complexity of this technology also involves important challenges. One of them is to develop surface determination algorithms capable of providing measurement results with better accuracy in any situation—for example, for single and multi-material parts, inner and outer geometries, with and without image artefacts, etc.—and reducing user influence. The surface determination is particularly complex in the case of multi-material parts, especially when they are separated by small air gaps. In previous works, two gradient-based algorithms were presented, that showed less measurement variability throughout the whole part, and reduced the computational cost and operator influence compared to threshold-based algorithms. This work focuses on the evaluation of the performance of these algorithms when used in a scenario so complex that parts of it are made of one or more materials (metal–metal and polymer–metal) with gaps inside. For this purpose, a set of multi-material reference standards is used. The presented gradient-based algorithms show measurement errors comparable to commercial threshold-based algorithms, but with the capability of obtaining accurate measurements in smaller gaps, apart from reducing the user influence on the measurement process.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Reference standard for the uncertainty estimation of X–ray Computed Tomography measurements of complex macro-and micro-geometries

  • Albajez, J.A.
  • Nuño, S.
  • Díaz, L.C.
  • Gallardo, D.
  • Yagüe, J.A.
  • Jiménez, R.
  • Torralba, M.
Traditionally, measuring both macro and micro geometries with a single device has been challenging in metrology. Coordinate Measuring Machines (CMM) are common devices for the inspection of large features, while optical microscopes can achieve resolutions in the order of micrometers in small areas. X-Ray Computed Tomography (XCT) has become a solution not only to characterize both micro and macro geometries, but also to inspect internal features without destroying the sample. In this field, various reference standards have been developed in order to verify the capabilities of XCT systems, these artefacts include geometrical features or profiles for roughness inspection. This paper shows the design and develompent of a reference standard for XCT test which includes internal and external geometrical features and profiles for macro and micro geometrical inspection. The model is manufactured by additive manufacturing (AM), easing the process of fabrication of the artefact and allowing to test the capabilities of this technology to produce reference standards.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Uncertainty budget of a large-range nanopositioning platform based on Monte Carlo simulation

  • Díaz-Pérez, L.C.
  • Torralba, M.
  • Muro, L.
  • Albajez, J.A.
  • Yagüe-Fabra, J.A.
The objective of precision systems design is to obtain machines with very high and totally predictable work-zone accuracies. In already functional systems, where the errors can be measured, this is achieved by error correction and compensation. The aim of this work is to propose an uncertainty budget methodology to obtain the final measuring uncertainty of precise measuring systems, after error compensation. The case study is a nanopositioning platform, referred as NanoPla, with a confocal sensor integrated as measuring instrument. The NanoPla performs precise positioning in a large range of 50 mm × 50 mm, and its target is surface topography characterization, at a submicrometre scale. After performing the uncertainty budget of the NanoPla, Monte Carlo method is used to obtain the final measuring uncertainty along the whole NanoPla working range, considering all the casuistry. By studying the results, the authors are able to propose solutions to minimize the final measuring uncertainty.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

X-ray computed tomography performance in metrological evaluation and characterisation of polymeric additive manufactured surfaces.

  • Gallardo, Daniel
  • Díaz, Lucía-Candela
  • Jiménez, Roberto
  • Torralba, Marta
  • Albajez, José Antonio
  • Yagüe Fabra, José Antonio
Surface characterisation has always been an important aspect in quality control for industrial parts. With the development of additive manufacturing (AM) technologies and the design freedom they provide, new measuring techniques have become necessary for inspection of inner elements and hidden surfaces. X-ray computed tomography (XCT) has the potential for this purpose. Its performance in surface characterisation has been studied mainly for new metallic AM technologies due to its extended use in industrial products; however, it is not possible to directly extend this knowledge to polymeric AM surface characterisation, due to the material, manufacturing process itself and behaviour with X-rays. In this paper, a study of different polymeric AM surfaces by means of XCT is presented, taking into consideration the layer-by-layer technology and geometrical parameters (angle of inclination, layer thickness). Areal and linear roughness parameters are extracted to create a comparison between XCT measurements and reference measurements with a calibrated focal variation microscope (FVM). A reasonably achievable geometrical magnification for a polymeric AM assembly with industrial part dimensions (28 µm voxel size for a 50 mm × 55 mm × 60 mm object) is demonstrated to be suitable for roughness evaluation with an acceptable precision. Results show that it is possible to evaluate roughness in FDM and Polyjet technologies with linear parameters, while areal parameters are more suitable for SLS parts; also, post process has an important role in surface characterisation, but its effect is different depending on the technology.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Progress toward the Definition of X-ray Computed Tomography Accuracy in the Characterization of Polymer-Based Lattice Structures

  • Gallardo, Daniel
  • Díaz, Lucía-Candela
  • Albajez, José Antonio
  • Yagüe-Fabra, José Antonio
Lattice structures have become an innovative solution for the improvement of part design, as they are able to substitute solid regions, maintain mechanical capabilities, and reduce material usage; however, dimensional quality control of these geometries is challenging. X-ray computed tomography (XCT) is the most suitable non-destructive metrological technique as it is capable of characterizing internal features and hidden elements. Uncertainty estimation of XCT is still in development, and studies typically use high-resolution calibrated devices such as focal variation microscopes (FVMs) as a reference, focusing on certain parts of the lattice but not the whole structure. In this paper, an estimation of the accuracy of XCT evaluation of a complete lattice structure in comparison to a higher-resolution reference device (FVM) is presented. Experimental measurements are taken on ad hoc designed test objects manufactured in polyamide 12 (PA12) using selective laser sintering (SLS), optimized for the evaluation on both instruments using different cubic-based lattice typologies. The results confirm higher precision on XCT evaluation in both qualitative and quantitative analysis. Even with a lower resolution, XCT is able to characterize details of the surface such as re-entrant features; as well, standard deviations and uncertainties in strut diameter evaluation remain more stable in all cells in XCT, identifying on the other hand reconstruction problems on FVM measurements. Moreover, it is shown that, using XCT, no additional evaluation errors were found in inner cells, suggesting that the measurement of external elements could be representative of the whole structure for metrological purposes.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

On the effect of material density in dimensional evaluations by X-ray computed tomography of metal-polymer multi-material parts

  • Gallardo, Daniel
  • Díaz, Lucía-Candela
  • Zanini, Filippo
  • Albajez, José Antonio
  • Carmignato, Simone
  • Yagüe-Fabra, José A.
An important aspect to consider in the evaluation of parts and assemblies by X-ray computed tomography (XCT) is the attenuation coefficient of the different materials involved, which are directly related to their density; depending on this coefficient, the X-ray penetration varies and, therefore, varies the contrast between different materials and with the background. This becomes more critical in those assemblies in which materials are characterized by a high difference in density, where the lighter material could be difficult to be characterised. In this paper, the effect of the presence of metals in the dimensional evaluation of polymeric geometries (having lower density than the metal parts) is studied, to evaluate the errors caused in dimensional measurements of different geometries and surface texture characterization. Based on a common geometry, four scenarios have been experimentally tested with variations of metal amount, in which macro geometries (precision spheres made by different polymers) and micro geometries (inclined ramps manufactured by fused deposition modelling (FDM)) have been characterised. Results show errors in the surface determination of the polymeric features directly related to the presence of metal: a high amount of steel makes significantly difficult to accurately determine the interface between background and material due to the noise and artifacts created, while aluminium has less influence on the irregularities of the features extracted. This effect is more evident for polymers with lower density due to the higher difference. Numerically, most affected parameters are those sensible to variations in surface determination, such as spheres’ form error and ramps’ maximum surface texture (Sz), while more solid features as spheres’ diameters, distances and ramps’ average surface texture (Sa and Sq) remain more stable. In conclusion and to sum up, it has been found that the quantity of metal present in assemblies made of polymeric and metallic materials is correlated with distortions in the dimensional evaluation of polymeric features by XCT.