Pasar al contenido principal

DEVELOPMENT OF TENSORIAL SIGNAL PROCESSING AND MACHINE LEARNING TOOLS TAILORED TO THE ANALYSIS OF URINE METABOLOMICS

RTI2018-098577-B-C22

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2018
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario FUNDACIO INSTITUT DE BIOENGINYERIA DE CATALUNYA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Full workflows for the analysis of gas chromatography-ion mobility spectrometry in foodomics: application to the analysis of iberian ham aroma

  • Freire, Rafael
  • Fernández, Luis
  • Mallafré-Muro, Celia
  • Martín-Gómez, Andrés
  • Madrid-Gambin, Francisco
  • Oliveira, Luciana
  • Pardo, Antonio
  • Arce, Lourdes
  • Marco, Santiago
Gas chromatography-ion mobility spectrometry (GC-IMS) allows the fast, reliable, and inexpensive chemical composition analysis of volatile mixtures. This sensing technology has been successfully employed in food science to determine food origin, freshness and preventing alimentary fraud. However, GC-IMS data is highly dimensional, complex, and suffers from strong non-linearities, baseline problems, misalignments, peak overlaps, long peak tails, etc., all of which must be corrected to properly extract the relevant features from samples. In this work, a pipeline for signal pre-processing, followed by four different approaches for feature extraction in GC-IMS data, is presented. More precisely, these approaches consist of extracting data features from: (1) the total area of the reactant ion peak chromatogram (RIC); (2) the full RIC response; (3) the unfolded sample matrix; and (4) the ion peak volumes. The resulting pipelines for data processing were applied to a dataset consisting of two different quality class Iberian ham samples, based on their feeding regime. The ability to infer chemical information from samples was tested by comparing the classification results obtained from partial least-squares discriminant analysis (PLS-DA) and the samples' variable importance for projection (VIP) scores. The choice of a feature extraction strategy is a trade-off between the amount of chemical information that is preserved, and the computational effort required to generate the data models., This work is part of the BEST Postdoctoral Program, funded by the European Commission under Horizon 2020 Marie Skłodowska-Curie Actions COFUND scheme (Grant Agreement no. 712754) and by the Severo Ochoa program of the Spanish Ministry of Science and Competitiveness (Grant SEV-2014-0425 (2015–2019)). We would like to acknowledge, the Departament d’Universitats, Recerca i Societat de la Informació de la Generalitat de Catalunya (expedient 2017 SGR 1721); the Comissionat per a Universitats i Recerca del DIUE de la Generalitat de Catalunya; and the European Social Fund (ESF). Additional financial support has been provided by the Institut de Bioenginyeria de Catalunya (IBEC). IBEC is a member of the CERCA Programme/Generalitat de Catalunya. This work has been additionally funded by Spanish MINECO Project TENSOMICS (RTI2018-098577-B-C22) and by the Consejería de Economía, Conocimiento, Empresas y Universidad de la Junta de Andalucía (Programa Operativo FEDER Andalucía 2014–2020. Convocatoria 2018. 1261925-R).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Full workflows for the analysis of gas chromatography-ion mobility spectrometry in foodomics: application to the analysis of iberian ham aroma

  • Freire, Rafael
  • Fernández, Luis
  • Mallafré-Muro, Celia
  • Martín-Gómez, Andrés
  • Madrid-Gambin, Francisco
  • Oliveira, Luciana
  • Pardo, Antonio
  • Arce, Lourdes
  • Marco, Santiago
Gas chromatography-ion mobility spectrometry (GC-IMS) allows the fast, reliable, and inexpensive chemical composition analysis of volatile mixtures. This sensing technology has been successfully employed in food science to determine food origin, freshness and preventing alimentary fraud. However, GC-IMS data is highly dimensional, complex, and suffers from strong non-linearities, baseline problems, misalignments, peak overlaps, long peak tails, etc., all of which must be corrected to properly extract the relevant features from samples. In this work, a pipeline for signal pre-processing, followed by four different approaches for feature extraction in GC-IMS data, is presented. More precisely, these approaches consist of extracting data features from: (1) the total area of the reactant ion peak chromatogram (RIC); (2) the full RIC response; (3) the unfolded sample matrix; and (4) the ion peak volumes. The resulting pipelines for data processing were applied to a dataset consisting of two different quality class Iberian ham samples, based on their feeding regime. The ability to infer chemical information from samples was tested by comparing the classification results obtained from partial least-squares discriminant analysis (PLS-DA) and the samples' variable importance for projection (VIP) scores. The choice of a feature extraction strategy is a trade-off between the amount of chemical information that is preserved, and the computational effort required to generate the data models., This work is part of the BEST Postdoctoral Program, funded by the European Commission under Horizon 2020 Marie Skłodowska-Curie Actions COFUND scheme (Grant Agreement no. 712754) and by the Severo Ochoa program of the Spanish Ministry of Science and Competitiveness (Grant SEV-2014-0425 (2015–2019)). We would like to acknowledge, the Departament d’Universitats, Recerca i Societat de la Informació de la Generalitat de Catalunya (expedient 2017 SGR 1721); the Comissionat per a Universitats i Recerca del DIUE de la Generalitat de Catalunya; and the European Social Fund (ESF). Additional financial support has been provided by the Institut de Bioenginyeria de Catalunya (IBEC). IBEC is a member of the CERCA Programme/Generalitat de Catalunya. This work has been additionally funded by Spanish MINECO Project TENSOMICS (RTI2018-098577-B-C22) and by the Consejería de Economía, Conocimiento, Empresas y Universidad de la Junta de Andalucía (Programa Operativo FEDER Andalucía 2014–2020. Convocatoria 2018. 1261925-R).
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Quantitative GC-TCD Measurements of Major Flatus Components, A Preliminary Analysis of the Diet Effect

  • Freire, Rafael
  • Mego Silva, Marianela
  • Oliveira, Luciana Fontes
  • Mas, Silvia
  • Azpiroz Vidaur, Fernando|||0000-0002-7327-960X
  • Marco Colás, Santiago|||0000-0003-2663-2965
  • Pardo, Antonio|||0000-0003-4369-544X
The impact of diet and digestive disorders in flatus composition remains largely unexplored. This is partially due to the lack of standardized sampling collection methods, and the easy atmospheric contamination. This paper describes a method to quantitatively determine the major gases in flatus and their application in a nutritional intervention. We describe how to direct sample flatus into Tedlar bags, and simultaneous analysis by gas chromatography-thermal conductivity detection (GC-TCD). Results are analyzed by univariate hypothesis testing and by multilevel principal component analysis. The reported methodology allows simultaneous determination of the five major gases with root mean measurement errors of 0.8% for oxygen (O), 0.9% for nitrogen (N), 0.14% for carbon dioxide (CO), 0.11% for methane (CH), and 0.26% for hydrogen (H). The atmospheric contamination was limited to 0.86 (95% CI: [0.7-1.0])% for oxygen and 3.4 (95% CI: [1.4-5.3])% for nitrogen. As an illustration, the method has been successfully applied to measure the response to a nutritional intervention in a reduced crossover study in healthy subjects.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Breath analysis using electronic nose and gas chromatography-mass spectrometry, A pilot study on bronchial infections in bronchiectasis

  • Fontes de Oliveira, Luciana
  • Mallafré-Muro, Celia
  • Giner, Jordi|||0000-0002-3044-2059
  • Perea, Lidia|||0000-0002-1624-0012
  • Sibila, Oriol|||0000-0002-4833-6713
  • Pardo, Antonio|||0000-0003-4369-544X
  • Marco, Santiago
Background and aims: In this work, breath samples from clinically stable bronchiectasis patients with and without bronchial infections by Pseudomonas Aeruginosa- PA) were collected and chemically analysed to determine if they have clinical value in the monitoring of these patients. Materials and methods: A cohort was recruited inviting bronchiectasis patients (25) and controls (9). Among the former group, 12 members were suffering PA infection. Breath samples were collected in Tedlar bags and analyzed by e-nose and Gas Chromatography-Mass Spectrometry (GC-MS). The obtained data were analyzed by chemometric methods to determine their discriminant power in regards to their health condition. Results were evaluated with blind samples. Results: Breath analysis by electronic nose successfully separated the three groups with an overall classification rate of 84% for the three-class classification problem. The best discrimination was obtained between control and bronchiectasis with PA infection samples 100% (CI: 84-100%) on external validation and the results were confirmed by permutation tests. The discrimination analysis by GC-MS provided good results but did not reach proper statistical significance after a permutation test. Conclusions: Breath sample analysis by electronic nose followed by proper predictive models successfully differentiated between control, Bronchiectasis and Bronchiectasis PA samples.