Exploring new venues in trace elemental and isotopic analysis via ICP-mass spectrometry: a novel approach for nano-quantification

RYC2021-031093-I

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Desarrollar, Atraer y Retener Talento
Subprograma Subprograma Estatal de Incorporación
Convocatoria Ramón y Cajal
Año convocatoria 2021
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD DE ZARAGOZA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 18
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Serum Mg isotopic composition reveals that Mg dyshomeostasis remains in type 1 diabetes despite the resolution of hypomagnesemia

  • Sullivan, Kaj Vaughan
  • Assantuh, Yasmina
  • Grigoryan, Rosa
  • Costas-Rodríguez, Marta
  • Bolea-Fernandez, Eduardo
  • Lapauw, Bruno
  • Van Laecke, Steven
  • Vanhaecke, Frank
Hypomagnesemia was historically prevalent in individuals with type 1 diabetes mellitus (T1DM), but contemporary results indicate an incidence comparable to that in the general population, likely due to improved treatment in recent decades, resulting in better glycemic control. However, a recent study found a significant difference between the serum Mg isotopic composition of T1DM individuals and controls, indicating that disruptions to Mg homeostasis persist. Significant deviations were also found in samples taken one year apart. To investigate whether the temporal variability in serum Mg isotopic composition is linked to the transient impact of administered insulin, Mg isotope ratios were determined in serum from 15 T1DM individuals before and one hour after insulin injection/meal consumption using multi-collector inductively coupled plasma-mass spectrometry. Consistent with results of the previous study, significant difference in the serum Mg isotopic composition was found between T1DM individuals and 10 sex-matched controls. However, the average difference between pre- and post-insulin injection/meal T1DM samples of 0.05 ± 0.13‰ (1SD) was not significant. No difference was observed for controls before (−0.12 ± 0.16‰) and after the meal (−0.10 ± 0.13‰) either, suggesting a lack of a postprandial Mg isotopic response within one hour of food consumption, and that the timing of the most recent meal may not require controlling for when determining serum Mg isotopic composition.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A comparison of calibration strategies for quantitative laser ablation ICP-mass spectrometry (LA-ICP-MS) analysis of fused catalyst samples

  • Rua-Ibarz, Ana
  • Van Acker, Thibaut
  • Bolea-Fernández, Eduardo
  • Boccongelli, Marina
  • Vanhaecke, Frank
In the field of petrochemistry, the quantitative determination of trace elements in catalysts is crucial for optimizing various types of processes. Catalyst poisoning, resulting from the presence of contaminants, can lead to decreased performance and efficiency, even when these are present at trace level only. Inductively coupled plasma-mass spectrometry (ICP-MS) is a powerful technique for trace elemental analysis, but its application to catalysts is challenging due to their physicochemical characteristics challenging straightforward dissolution. Laser ablation (LA) coupled to ICP-MS (LA-ICP-MS) has emerged as a valuable approach for direct analysis of solid samples. However, developing an appropriate calibration strategy for reliable quantitative LA-ICP-MS analysis of catalyst samples remains a challenge. In this work, different calibration strategies for quantitative LA-ICP-MS analysis of fused catalyst samples were evaluated. The traditional strategy relied on external calibration against certified reference materials (CRMs) combined with internal standardization and was considered the reference approach. When using this approach, the relative bias with respect to the reference value was found to be <15%. Two novel calibration strategies were introduced and compared: a so-called multi-signal calibration approach and a solution-based calibration approach. The multi-signal calibration strategy involved varying the laser repetition rate (20, 30, 40 and 50 Hz) or laser beam diameter (10, 12, 15 and 20 μm), allowing a calibration curve to be constructed by comparing the analytical signal intensity for a single solid CRM with that for the sample, thus partially overcoming the shortage of CRMs for quantitative LA-ICP-MS analysis. The solution-based calibration approach was used for quantitative multi-element analysis without the need for any solid standard and required only minor hardware modifications to accommodate the introduction of aqueous standard solutions for calibration. Various glass certified reference materials were used for method development, calibration, and validation purposes. Furthermore, two fused alumina catalyst samples (used in the context of petroleum refining processes) were successfully analyzed as a proof-of-concept application. For both the multi-signal (matrix-matched conditions) and the solution-based calibration approaches, the average relative bias between the experimentally determined and certified/reference concentrations varied between −9% and +7%.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Extending the application range of Hg isotopic analysis to sub-µg L-1 levels using cold vapor generation multi-collector inductively coupled plasma-mass spectrometry with 1013 ohm Faraday cup amplifiers

  • Suárez-Criado, Laura
  • Bolea-Fernández, Eduardo
  • Abou-Zeid, Lana
  • Vandermeiren, Mathias
  • Rodríguez-González, Pablo
  • Garcia Alonso, Jose Ignacio
  • Vanhaecke, Frank
High-precision determination of the isotopic composition of mercury (Hg) is of paramount importance for unraveling its biogeochemical cycle and for identifying the origin of Hg in environmental compartments. Cold vapor generation multi-collector inductively coupled plasma-mass spectrometry (CVG-MC-ICP-MS) is the standard approach for such application. Cold vapor generation provides a high Hg introduction efficiency into the ICP, while chromatographic Hg isolation is not required as a result of the selective reaction between Hg2+ and SnCl2. For environmental or biota samples with low Hg concentrations, however, this approach still presents challenges and reliable measurements typically require a Hg concentration ≥1 μg L−1 in the solution analyzed. Recent improvements of MC-ICP-MS instrumentation, including the introduction of the so-called Jet interface and 1013 Ω Faraday cup amplifiers, enhance the signal-to-noise ratio. In this study, it was investigated to what extent this allows Hg isotopic analysis at lower concentration. Performance in Hg isotopic analysis was compared using two different sets of cones (standard vs. Jet), two plasma conditions (wet vs. dry) and two amplifier types (1011 Ω vs. 1013 Ω). Satisfactory accuracy and precision were achieved at a Hg concentration down to 0.1 μg L−1 in the solution measured when using Jet cones, dry plasma conditions, and the four available 1013 Ω amplifiers. The uncertainty expressed as 2SD for the δ202Hg values measured for the in-house standard solution was ±0.2‰ at 0.25 μg Hg L−1 and ± 0.3‰ at 0.1 μg Hg L−1. The method was subsequently applied to the analysis of real surface water samples contaminated with toxic metals.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Tracing isotopically labeled selenium nanoparticles in plants via single-particle ICP-mass spectrometry

  • Moreira Freire, Bruna
  • Rua-Ibarz, Ana
  • Venâncio Nakadi, Flávio
  • Bolea-Fernández, Eduardo
  • Barriuso-Vargas, Juan J.
  • Lange, Camila Neves
  • Aramendía, Maite
  • Batista, Bruno Lemos
  • Resano, Martín
Agronomic biofortification using selenium nanoparticles (SeNPs) shows potential for addressing selenium deficiency but further research on SeNPs-plants interaction is required before it can be effectively used to improve nutritional quality. In this work, single-particle inductively coupled plasma-mass spectrometry (SP-ICP-MS) was used for tracing isotopically labeled SeNPs (82SeNPs) in Oryza sativa L. tissues. For this purpose, SeNPs with natural isotopic abundance and 82SeNPs were synthesized by a chemical method. The NPs characterization by transmission electron microscopy (TEM) confirmed that enriched NPs maintained the basic properties of unlabeled NPs, showing spherical shape, monodispersity, and sizes in the nano-range (82.8 ± 6.6 nm and 73.2 ± 4.4 nm for SeNPs and 82SeNPs, respectively). The use of 82SeNPs resulted in an 11-fold enhancement in the detection power for ICP-MS analysis, accompanied by an improvement in the signal-to-background ratio and a reduction of the size limits of detection from 89.9 to 39.9 nm in SP-ICP-MS analysis. This enabled 82SeNPs to be tracked in O. sativa L. plants cultivated under foliar application of 82SeNPs. Tracing studies combining SP-ICP-MS and TEM-energy-dispersive X-ray spectroscopy data confirmed the uptake of intact 82SeNPs by rice leaves, with most NPs remaining in the leaves and very few particles translocated to shoots and roots. Translocation of Se from leaves to roots and shoots was found to be lower when applied as NPs compared to selenite application. From the size distributions, as obtained by SP-ICP-MS, it can be concluded that a fraction of the 82SeNPs remained within the same size range as that of the applied NP suspension, while other fraction underwent an agglomeration process in the leaves, as confirmed by TEM images. This illustrates the potential of SP-ICP-MS analysis of isotopically enriched 82SeNPs for tracing NPs in the presence of background elements within complex plant matrices, providing important information about the uptake, accumulation, and biotransformation of SeNPs in rice plants.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Development and initial evaluation of a combustion-based sample introduction system for direct isotopic analysis of mercury in solid samples via multi-collector ICP-mass spectrometry

  • Bolea-Fernández, Eduardo
  • Rua-Ibarz, Ana
  • Anjos, Jorge Alves
  • Vanhaecke, Frank
High-precision isotopic analysis of mercury (Hg) using multi-collector ICP-mass spectrometry (MC-ICP-MS) is a powerful method for obtaining insight into the sources, pathways and sinks of this toxic metal. Modification of a commercially available mercury analyzer (Teledyne Leeman Labs, Hydra IIc – originally designed for quantification of Hg through sample combustion, collection of the Hg vapor on a gold amalgamator, subsequent controlled release of Hg and detection using cold vapor atomic absorption spectrometry CVAAS) enabled the system to be used for the direct high-precision Hg isotopic analysis of solid samples using MC-ICP-MS – i.e., without previous sample digestion and subsequent dilution. The changes made to the mercury analyzer did not compromise its (simultaneous) use for Hg quantification via CVAAS. The Hg vapor was mixed with a Tl-containing aerosol produced via pneumatic nebulization, creating wet plasma conditions, and enabling the use of Tl as an internal standard for correction of instrumental mass discrimination. Accurate and precise (0.10 ‰ 2SD, δ202Hg, n = 5) results were obtained for an in-house standard solution of Hg (20 ng Hg sample intake). Initial validation relied on the successful analysis of two solid certified reference materials of biological origin (BCR CRM 464 Tuna fish and NRC-CNRC TORT-3 Lobster hepatopancreas). It was shown that instrumental mass discrimination can be adequately corrected for by relying on the use of an aqueous Hg standard solution (NIST SRM 3133), without the need of matrix-matching. The novel setup developed thus allows for direct high-precision isotopic analysis of Hg in solid samples, thus enhancing the sample throughput. It is also suited for samples for which low amounts are available only and/or that are characterized by low Hg concentrations.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Intensity- and time-based strategies for micro/nano-sizing via single-particle ICP-mass spectrometry: A comparative assessment using Au and SiO2 as model particles

  • Bazo, Antonio
  • Bolea-Fernandez, Eduardo
  • Rua-Ibarz, Ana
  • Aramendía, Maite
  • Resano, Martín
Background Single-particle ICP-mass spectrometry (SP-ICP-MS) is a powerful method for micro/nano-particle (MNP) sizing. Despite the outstanding evolution of the technique in the last decade, most studies still rely on traditional approaches based on (1) the use of integrated intensity as the analytical signal and (2) the calculation of the transport efficiency (TE). However, the increasing availability of MNP standards and advancements in hardware and software have unveiled new venues for MNP sizing, including TE-independent and time-based approaches. This work systematically examines these different methodologies to identify and summarize their strengths and weaknesses, thus helping to determine their preferred application areas. Results Different SP-ICP-MS methods for MNP sizing were assessed using AuNPs (20–70 nm) and SiO2MNPs (100–1000 nm). Among TE-dependent approaches, the particle frequency method was characterized by larger uncertainties than the particle size method. The results of the latter were dependent on the appropriate selection of the reference MNP, making the use of multiple reference MNPs recommended. TE-independent methods were based on external (linear and polynomial) calibrations and a relative approach. These methods exhibited the lowest uncertainties of all the strategies evaluated. External calibrations benefited from simpler calculations, but their application could be hindered by a lack of reference MNPs within the desired size range or by the need for interpolations outside the calibration range. Finally, transit time signals are directly proportional to the MNP size rather than its mass. The time-based method demonstrated adequate performance for sizing AuNPs but failed when sizing the largest SiO2MNPs (1000 nm). Significance and novelty This work provides further insights into the application of different SP-ICP-MS methodologies for MNP sizing. Both TE-independent approaches and the monitoring of the transit time as the analytical signal are underused strategies; in this context, a Python script was developed for accurate transit time measurement. After 20 years of development, a quantitative comparison of the different methodologies, including the most novel approaches, is deemed necessary for further growth on solid theoretical ground.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

An evaluation of the analytical and biological robustness of a method for quantifying iron in individual red blood cells via single-cell tandem ICP-mass spectrometry

  • Dejonghe, Rinus
  • Bolea-Fernández, Eduardo
  • Lores-Padin, Ana
  • Van Acker, Thibaut
  • Rua-Ibarz, Ana
  • De Wever, Olivier
  • Vanhaecke, Frank
This work evaluated the analytical and biological robustness of iron (Fe) determination in individual red blood cells (RBCs) via single-cell ICP-MS (SC-ICP-MS). RBCs were separated from other whole blood constituents using Ficoll-Paque™ density gradient centrifugation. While fixation with paraformaldehyde (PFA) led to RBC lysis, the use of glutaraldehyde (GA) left the RBCs intact and permitted storage of RBC suspensions in ultra-pure water for up to 16 months at 4 °C. GA-fixation also rendered the RBCs sufficiently robust to maintain integrity during their introduction into the ICP by means of nebulization of dilute suspensions. Obtaining quantitative data on a cell-per-cell basis required determination of the transport efficiency using the particle size method and external calibration against aqueous Fe standard solutions. The average Fe content per RBC obtained using SC-ICP-MS (103 fg/cell) agreed well with the value obtained using solution-based ICP-MS obtained after cell pellet digestion and with values obtained from literature. Variation of the cell number density in the suspensions analyzed between 1.5 × 105 and 6.0 × 105 cells per mL did not affect the result. Identical results from one-week interval blood drawings from healthy individuals demonstrate biological consistency. Compared to bulk analysis, the SC-ICP-MS approach offers the added value of providing information on the cell-to-cell heterogeneity in Fe content.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Cinnabar for Roman Ephesus: Material quality, processing and provenance

  • Rodler-Rørbo, Alexandra
  • Baragona, Anthony J.
  • Verbeemen, Eliah J.
  • Sørensen, Lasse Vilien
  • Çakmakoglu, Berk
  • Helvaci, Cahit
  • Bolea-Fernandez, Eduardo
  • Rua-Ibarz, Ana
  • Vanhaecke, Frank
  • Becker, Hilary
  • Artioli, Gilberto
  • Zabrana, Lilli
  • Debaille, Vinciane
  • Mattielli, Nadine
  • Goderis, Steven
  • Claeys, Philippe
Ephesus was an important harbor city that flourished during the Roman period and ancient texts mention Almadén in Spain and the Cilbian fields of Ephesus as important cinnabar sources in antiquity. This work investigates whether imported cinnabar was used and whether this could be related to changes in painting activities over time. Microscopic analysis indicates a consistent preparation of cinnabar, hinting at a uniform source material quality or processing technique. However, the use of cinnabar varies among the architectural structures studied, indicating a plurality of painting techniques. A few of the analyzed cinnabar samples overlap with Turkish- and Balkan reference Pb isotope ratios; three samples from tabernas, however, deviate from this. The Hg isotope ratios reveal that cinnabar from carbonate-hosted deposits was likely used, and that processing of cinnabar included heating as suggested by ancient texts. Most notably, a correlation exists between the geochemical data and the painting technique – shifts in sourcing and cinnabar usage are potentially assignable to building chronology and/or usage. Through the lens of material provenance and processing, Ephesian cinnabar brings the organization of pigment trade into focus.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

High-precision Cu isotopic analysis of human dietary Cu sources via multi-collector ICP-mass spectrometry

  • Sullivan, Kaj V.
  • Moser, Katharina
  • Costas-Rodríguez, Marta
  • Bolea-Fernandez, Eduardo
  • Vanhaecke, Frank
The disruption of Cu homeostasis is associated with the pathogenesis of many diseases and can result in alterations in Cu isotope fractionation. Changes in the Cu isotope ratio (65Cu/63Cu) of body fluids and tissues have been observed in liver disorders, cancers, and other diseases, displaying diagnostic/prognostic potential. However, it is not entirely clear whether certain physiological or lifestyle factors may also influence the bodily Cu isotopic composition, potentially obfuscating the signature of the pathology. To ascertain whether differences exist between food products, the Cu isotopic composition of 29 significant dietary Cu sources has been determined for the first time. The general enrichment of Cu and its heavy isotope, 65Cu, in legumes, nuts, and seeds (major Cu sources in plant-based diets) was revealed, suggesting that individuals with plant-based diets may have a bodily Cu isotopic composition offset from that of individuals with omnivorous diets, thus requiring controlling for in study design.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Ions with Ions, Entities with Entities: A Proof-of-Concept Study Using the SELM-1 Yeast Certified Reference Material for Intra- and Extracellular Se Quantification via Single-Cell ICP-Mass Spectrometry

  • Bazo, Antonio
  • Bolea-Fernandez, Eduardo
  • Rua-Ibarz, Ana
  • Aramendía, Maite
  • Resano, Martín
In this work, two novel nanoparticle (NP)-based calibration strategies, external calibration and a relative method, have been explored for single-cell ICP-mass spectrometry (SC-ICP-MS) analysis. The fundamental principle of these methods is to rely on individual entities (well-characterized NPs of the target analyte) for calibration rather than on ionic standard solutions. The performance of the NP-based calibration approaches has been compared to that of the reference method (particle size with AuNP standards). In addition to the intracellular Se content (mass per individual cell), the extracellular Se (dissolved fraction) was also determined directly and simultaneously using the average background from the SC-ICP-MS time-resolved signal. The figures-of-merit of the methods developed have been evaluated by relying on the analysis of the SELM-1 cell-certified reference material, consisting of Se-enriched yeast cells, and certified for its total Se content (intracellular + extracellular Se). All methods successfully determined the Se elemental contents, but an improvement in accuracy and precision was observed for the NP-based methods compared to the reference one. Furthermore, the NP-based methods were found to be less time-consuming, more straightforward, and more user-friendly in terms of calculations. These results open new avenues for calibration in quantitative SC-ICP-MS analysis and call for a fundamental change in the methodology, where the determination of ionic contents is based on the use of ionic standard solutions for calibration, while the determination of elemental contents in discrete micro/nanoentities, such as cells, should ideally be based on calibration using standard entities, thus avoiding the need to calculate a transport efficiency coefficient.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Improving transport efficiency for large human cells for enabling accurate determination of cellular nanoparticle uptake via SC-ICP-TOF-MS

  • Nikolic, Mina
  • Lores-Padin, Ana
  • Van Acker, Thibaut
  • Smets, Tina
  • Goemaere, Ilia
  • Ahmad, Amin
  • Braeckmans, Kevin
  • Bolea-Fernandez, Eduardo
  • Vanhaecke, Frank
Single-cell inductively coupled plasma-mass spectrometry (SC-ICP-MS) provides high-throughput, quantitative information on nanoparticle (NP)–cell interaction, but its application to larger mammalian cells remains limited due to the low transport efficiency (TE) provided by commercially available introduction systems. In this study, we have addressed this challenge by working at a higher spray chamber temperature (150 °C), which led to a 81-fold increase in TE for A549 human lung carcinoma cells (measured size of ∼20 μm). This observation was also validated using other cell types with different sizes and morphologies, such as red blood cells (∼6 μm) and Raji cells (∼11 μm), for which respective TE improvements of 2.3- and 13-fold were observed. Coupling the optimized setup to a time-of-flight ICP-MS (ICP-TOF-MS) unit enabled quasi-simultaneous monitoring of nearly the entire elemental mass range, allowing clear differentiation between a) cells with AuNPs, b) cells without AuNPs, and c) free AuNPs, by simultaneously monitoring the presence of cellular components (P, Zn), NPs (Au), and a DNA intercalator (Ir). The method developed was subsequently applied to study the uptake of AuNPs in cells, which is relevant for fields like drug delivery and nanotoxicology. Quantification of the number of AuNPs per cell across varying NP concentrations revealed an overdispersed Poisson distribution, consistent with theoretical expectations. Further method validation via LA-ICP-TOF-MS was used to confirm the biological relevance of the results. Overall, this study presents a robust SC-ICP-MS workflow for studying large human cells and demonstrates its utility in studying the uptake of metallic NPs in cells.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A novel particle mass calibration strategy for the quantification of AuNPs in single cancer cells <i>via</i> laser ablation ICP-mass spectrometry. A case study

  • Bazo, Antonio
  • Bolea-Fernandez, Eduardo
  • Billimoria, Kharmen
  • Rua-Ibarz, Ana
  • Aramendía, Maite
  • Menero-Valdés, Paula
  • Morley, Jack
  • Neves, Sara
  • Sánchez-Cachero, Armando
  • Goenaga-Infante, Heidi
  • Resano, Martín
Laser ablation ICP-mass spectrometry (LA-ICP-MS) has developed as a powerful tool for elemental quantitative analysis of individual cells, assuring that the content of each cell is analyzed individually. However, this technique is still limited by the difficulties associated with calibration using solid standards. This work proposes a particle mass calibration strategy that is independent of both the properties and thickness of the gelatin films used for calibration, overcoming a significant drawback of previously established methods. The fundamental principle of this strategy relies on the individual ablation of nanoparticles (NPs) of well-characterized size that are embedded in the films, so that their mass can be directly used for calibration without the need to calculate their exact concentration within the gelatin. The performance of the newly developed method was compared to that of the previously reported approaches (ionic and particle number calibration) in terms of linearity and homogeneity between different films prepared from the same gelatin solution. As a case study, the three calibration strategies were used for the quantitative analysis of HeLa cancer cells exposed to AuNPs. In parallel, in-suspension single-cell (SC) ICP-MS Au data were obtained and used as reference for comparison with the three LA-SC-ICP-MS strategies. The results obtained with the novel particle mass approach demonstrated better accuracy and repeatability over three different working sessions, addressing key limitations and providing a robust and reliable method for quantitative LA-SC-ICP-MS analysis. The particle mass method holds promise for quantitative LA-ICP-MS analysis of samples beyond NP-exposed cells, such as biological tissues.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Laser Ablation for Nondestructive Sampling of Microplastics in Single-Particle ICP-Mass Spectrometry

  • Van Acker, Thibaut
  • Rua-Ibarz, Ana
  • Vanhaecke, Frank
  • Bolea-Fernandez, Eduardo
In this work, laser ablation (LA) was characterized as a method for sampling and introducing microplastic particles (MPs) into an inductively coupled plasma (ICP) for subsequent 13C+ monitoring using an ICP-mass spectrometer operated in single-event mode. MPs of different types (PS, PMMA, and PVC) and sizes (2–20 µm) were introduced intactly. The laser energy density did not affect the particle sampling across a wide range (0.25–6.00 J cm–2). Single-shot analysis separated clustered MPs (2–7 MPs per cluster) during the LA and particle transport processes, allowing the temporally resolved analysis of the individual constituting MPs. Line scanning showed superior performance when using a small laser beam diameter combined with a high repetition rate. The 13C+ signal intensity correlated linearly (R2 >0.9945) with the absolute C mass in a 2–10 µm size range, while the use of He in the collision-reaction cell (CRC) allowed extension of the linear range to 20 µm. The LA approach generated narrower 13C+ signal distributions than the traditional solution-based approach (dry versus wet plasma conditions) and proved successful for the analysis of a mixed suspension (containing four sizes of PS MPs in a 2–5 µm size range) and for sampling MPs from PVDF and glass microfiber filters, with the latter offering a lower background.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Improving detection and figures of merit in single-particle inductively coupled plasma-mass spectrometry via transient event heights

  • Bazo, Antonio
  • López-Villellas, Lorién
  • Mataloni, Matilde
  • Bolea-Fernandez, Eduardo
  • Rua-Ibarz, Ana
  • Grotti, Marco
  • Aramendía, Maite
  • Resano, Martín
Background: Single-particle inductively coupled plasma-mass spectrometry (SP-ICP-MS) is a powerful method for characterizing micro- and nanoparticulate materials. The technique primarily relies on the linear relationship between the integrated intensities of individual events (peak areas) and the analyte mass, though transit times (peak widths) have also been used for quantitative purposes. This work (1) evaluates the potential of using peak heights as analytical signals in SP-ICP-MS, (2) introduces a new method for determining peak heights, and (3) explores scenarios in which peak height offers added value over the commonly used SP-ICP-MS signals. Results: A new method was proposed to estimate peak height values in SP-ICP-MS accurately. The cumulative intensity across consecutive dwell times was modeled using a third-degree polynomial, from which the adjusted peak height was derived. This approach reduces the uncertainty associated with using raw maximum intensity values, yielding NP distributions comparable to those obtained via integrated intensities. The effect of dwell time on peak height was also evaluated. An optimal range (50 μs–200 μs) was identified, where a linear relationship was observed between the peak height and the square of the NP diameter. Within this range, peak height showed the lowest bias when characterizing smaller NPs, indicating the potential to improve the limit of quantification (LoQ). Additionally, peak heights proved helpful in determining the limit of detection (LoD) and setting appropriate threshold values for data processing, thereby helping to flag incorrect resultsand addressing a challenge in SP-ICP-MS analysis. Significance: This is the first study to evaluate peak height as an analytical signal in SP-ICP-MS. The results highlight its advantages in specific applications, such as sizing NPs near the LoD, and in supporting the more reliable use of other signals, such as peak areas, by helping to identify incorrect threshold selection that could lead to biased distributions. Finally, monitoring peak heights allows for a more realistic and assumption-free determination of the LoD.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Discrete Entity Analysis via Microwave-Induced Nitrogen Plasma–Mass Spectrometry in Single-Event Mode

  • Rua-Ibarz, Ana
  • Nakadi, Flávio V.
  • Bolea-Fernandez, Eduardo
  • Bazo, Antonio
  • Battistella, Beatrice
  • Matiushkina, Anna
  • Resch-Genger, Ute
  • Abad, Carlos
  • Resano, Martín
In this work, single-event microwave-induced nitrogen plasma–mass spectrometry (single-event MINP-MS) was evaluated for the first time for the analysis of discrete entities such as nanoparticles, biological cells, and microplastics. Nitrogen (N2) effectively overcomes Ar-based polyatomic interferences, enabling (ultra)trace element determination of Fe and Se using their most abundant isotopes, 56Fe (91.66%) and 80Se (49.82%). Iron oxide nanoparticles (Fe2O3 NPs) ranging from 20 to 70 nm were accurately characterized, with excellent agreement with established sizing techniques, such as transmission electron microscopy (TEM) and dynamic light scattering (DLS). A limit of detection (LoD) of 8.6 ag for Fe─equivalent to an LoDsize of 19 nm for Fe2O3─was achieved, which is significantly lower than recent values reported for high-end quadrupole-based ICP-MS. Selenium nanoparticles (SeNPs) of 150 and 250 nm were also accurately characterized, without the N2-based plasma experiencing issues handling relatively large metallic NPs (linearity, R2 = 0.9994). Se-enriched yeast cells (SELM-1 certified reference material) were successfully analyzed via single-cell MINP-MS using external calibration based on SeNPs and a transport efficiency-independent approach. In addition, 2–3 μm polystyrene (PS) and polytetrafluoroethylene (PTFE) were accurately sized by monitoring 12C+, confirming the method’s suitability for handling micrometer-sized polymeric materials (microplastics). The average duration of individual events (680 ± 160 μs) suggests that the digestion of individual entities in N2-based plasmas is comparable to that in Ar-based plasmas. These results open new avenues for this instrumentation as an alternative to ICP ionization sources, also in the context of discrete entity analysis.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

From pitfalls to progress in quantitative single-cell elemental analysis by time-of-flight ICP-mass spectrometry

  • Dejonghe, Rinus
  • Lores-Padin, Ana
  • Bolea-Fernandez, Eduardo
  • Van Acker, Thibaut
  • De Wever, Olivier
  • Vanhaecke, Frank
The aim of this study was to evaluate the capabilities and limitations of single-cell elemental analysis of tandem and time-of-flight ICP-mass spectrometry (SC-ICP-MS/MS and SC-ICP-ToF-MS). As partial detection of elemental distributions remains underexplored in the context of single-cell analysis, event detection, data completeness, and the reliability of derived quantitative results were investigated. The effects of detection thresholds, instrumentation type, and transient signal characteristics on the integrity of single-cell datasets and their interpretation were addressed. Red blood cells (RBCs) and peripheral blood mononuclear cells (PBMCs) were isolated, fixed with glutaraldehyde, and analyzed using both ICP-MS/MS and ICP-ToF-MS, while average contents (fg per cell) were additionally determined by bulk analysis. One key finding was that although ICP-MS/MS offers higher sensitivity, it is incompatible with multi-elemental profiling, while the sequential data acquisition for different target elements leads to inconsistent cell counts (observed cell events) during consecutive runs. In contrast, ICP-ToF-MS provides (quasi-)simultaneous detection, allowing comprehensive and consistent characterization when using an endogenous (e.g., Fe in RBCs) or exogenous (e.g., Ir from a DNA intercalator in PBMCs) cell marker. The use of such a cell marker reveals how many cells remain undetected for each element under real experimental conditions. Second, by varying signal thresholds during data processing, the influence on (partially) detected mass distributions and the impact on mean signal intensities were evaluated. This confirmed that when detection thresholds exclude low-intensity events, the resulting distributions are biased. This study underscores the need for improved instrumental sensitivity for biologically relevant low-mass elements, especially for ToF-based ICP-mass spectrometers, as well as for careful interpretation of (partially) detected datasets to avoid misleading conclusions.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Determining Si/Al atomic ratios in particulate matter via quadrupole single-particle ICP-MS with combined unit-mass and bandpass resolution modes: a proof-of-concept study on Antarctic snow

  • Mataloni, Matilde
  • Bazo, Antonio
  • Bolea-Fernandez, Eduardo
  • Rua-Ibarz, Ana
  • Aramendía, Maite
  • Güemes, Lucas
  • Téllez, Carlos
  • Coronas, Joaquín
  • Grotti, Marco
  • Resano, Martín
Micrometer-scale mineral dust deposited in Antarctica represents a valuable archive for reconstructing atmospheric variability and for improving our understanding of dust-climate interactions. Among the various types of particle-specific information available, elemental ratios, such as the Si/Al atomic ratio, are especially useful as geochemical indicators of particle composition and provenance. However, the nature of these samples, characterized by coexisting particle populations and limited particle numbers, makes this determination particularly challenging. In this work, a novel quadrupole-based single-particle ICP-mass spectrometry (SP-ICP-QMS) approach to determine population-specific Si/Al atomic ratios containing chemically heterogeneous particle populations is presented. To overcome the sequential acquisition inherent to ICP-QMS instrumentation, Al and Si measurements at unit-mass resolution (m/z 27 and 28, respectively) were combined with bandpass acquisition centered at m/z 27 (2.47 ± 0.06 amu resolution at 10% peak height), enabling simultaneous collection of 27Al+ and 28Si + signals. This strategy was first used to identify the Al and Si distributions belonging to the same particle population and, consequently, to determine the corresponding atomic ratios in a suspension containing SiO2 microparticles (MPs) and two different types of synthesized zeolite MPs with different Si/Al atomic ratios. The reliability and accuracy of the method were confirmed by comparing the results with those obtained from individual Scanning Electron Microscopy with Energy Dispersive X-ray Spectroscopy (SEM-EDX) and SP-ICP-MS characterization of the zeolite samples. As a proof-of-concept, the analysis of an Antarctic snow sample demonstrated the potential of the developed method to provide population-specific information - Si/Al atomic ratios - essential for environmental assessments based on high-resolution short-term records.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Direct Characterizationof Halogen-Based Microplasticsvia Single-Event ICP-Mass Spectrometry in Negative-Ion Mode

  • Bazo, Antonio
  • Bolea-Fernandez, Eduardo
  • Rua-Ibarz, Ana
  • Resano, Martín
  • Badiei, Hamid
  • Clases, David
  • Raab, Andrea
  • Feldmann, Jörg
  • Gonzalez de Vega, Raquel
Halogen-containing microplastics such as polytetrafluoroethylene (PTFE) and poly(vinyl chloride) (PVC) are analytically relevant targets, yet their selective characterization by ICP-MS remains challenging, particularly for fluoropolymers due to the limited formation of F+ in conventional positive-ion mode. Here we introduce negative-ion single-event ICP-MS as a direct strategy for particle-resolved characterization of halogen-containing microplastics by monitoring F– and Cl– on a quadrupole ICP-MS without plasma modifiers or proxy-ion chemistry. PTFE and PVC particle standards were used as well-defined model systems, with scanning electron microscopy (SEM) confirming particle morphology and size distributions. Key acquisition and instrumental conditions governing event detectability were systematically optimized, enabling reliable transient detection at a dwell time of 100 μs. Using a conventional spray-chamber configuration, size detection limits of 1.18 μm (PTFE) and 0.73 μm (PVC) were achieved, improving to 0.68 μm (PTFE) and 0.45 μm (PVC) with a high-efficiency sample introduction system. Quantification strategies for negative-mode operation, including external calibration and transport-efficiency-based workflows, were further assessed. Overall, this work establishes negative-ion mode single-event ICP-MS as a direct platform for fluorine- and chlorine-selective microplastic detection and sizing, expanding the analytical scope of particle-resolved microplastic analysis beyond indirect fluorine detection or carbon-based approaches.