Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 8
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Design and validation of an immersive virtual rehabilitation system for individuals with vestibular disorders: A feasibility study

  • Ibrahem-Altwijri, Abdulaziz
  • Albiol-Perez, Sergio
  • Cortes-Vega, Maria-Dolores
  • Garcia-Munoz, Cristina
  • Ramirez de Arellano, Rocio Sasian
  • Casuso-Holgado, Maria Jesus
  • Gil-Gómez, José-Antonio|||0000-0001-9954-2480
  • Lozano Quilis, José Antonio|||0000-0002-7756-183X
[EN] Background Vestibular rehabilitation is an essential part of managing balance disorders, but traditional exercises can often be repetitive and demotivating for patients. This can reduce adherence and limit treatment outcomes.Objective This study aimed to assess the feasibility, usability, patient satisfaction, and safety of DizzyVR, an immersive virtual reality system designed to support vestibular rehabilitation. Preliminary data on its potential effects on clinical outcomes were also collected.Methods A prospective, single-arm feasibility study was conducted with ten participants diagnosed with various vestibular disorders. Each participant completed eight weekly sessions using DizzyVR. Feasibility was assessed through session attendance and completion rates. Usability, satisfaction, and safety were measured using the System Usability Scale, the User Satisfaction Evaluation Questionnaire, and the Simulator Sickness Questionnaire. Clinical measures included the Dizziness Handicap Inventory (DHI), Timed Up and Go (TUG) test, Activities-specific Balance Confidence (ABC) scale, and Functional Gait Assessment (FGA).Results Ten participants completed the training, with a high adherence rate (91.25%). Usability scores indicated good ease of use, and satisfaction scores were high. Mild adverse events such as nausea or disorientation were reported by three participants, but improved over time. Exploratory pre-post changes were observed in gait speed (TUG: p = 0.002), balance confidence (ABC: p = 0.007), and gait stability (FGA: p = 0.012). While DHI scores demonstrated a trend toward improvement, the change did not reach statistical significance (p = 0.081). Overall, participants reported feeling safe and expressed willingness to recommend and reuse the system.Conclusions The findings suggest that DizzyVR is a feasible, usable, and well-accepted tool that may complement conventional vestibular rehabilitation. The system appears to support patient motivation and safe participation while showing promising exploratory changes in balance and gait. Further studies with larger samples, control groups, and longer follow-up are recommended to confirm and expand on these promising preliminary results., This research was funded by Grant T49_23R, funded by Gobierno de Aragon (Department of Science, University and Knowledge Society) and co-funded by the European Regional Development Fund (ERDF) "A way of making Europe". The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Fall detection in low-illumination environments from far-infrared images using pose detection and dynamic descriptors

  • Gutiérrez, Jesús
  • Martin, Sergio
  • Rodriguez, Victor H.
  • Albiol, Sergio
  • Plaza, Inmaculada
  • Medrano, Carlos
  • Martinez, Javier
In an increasingly aging world, the effort to automate tasks associated with the care of elderly dependent individuals becomes more and more relevant if quality care provision at sustainable costs is desired. One of the tasks susceptible to automation in this field is the automatic detection of falls. The research effort undertaken to develop automatic fall detection systems has been quite substantial and has resulted in reliable fall detection systems. However, individuals who could benefit from these systems only consider their use in certain scenarios. Among them, a relevant scenario is the one associated to semi-supervised patients during the night who wake up and get out of bed, usually disoriented, feeling an urgent need to go to the toilet. Under these circumstances, usually, the person is not supervised, and a fall could go unnoticed until the next morning, delaying the arrival of urgently needed assistance. In this scenario, associated with nighttime rest, the patient prioritizes comfort, and in this situation, body-worn sensors typical of wearable systems are not a good option. Environmental systems, particularly visual-based ones with cameras deployed in the patient’s environment, could be the ideal option for this scenario. However, it is necessary to work with far-infrared (FIR) images in the low-light conditions of this environment. This work develops and implements, for the first time, a fall detection system that works with FIR imagery. The system integrates the output of a human pose estimation neural network with a detection methodology which uses the relative movement of the body’s most important joints in order to determine whether a fall has taken place. The pose estimation neural networks used represent the most relevant architectures in this field and have been trained using the first large public labeled FIR dataset. Thus, we have developed the first vision-based fall detection system working on FIR imagery able to operate in conditions of absolute darkness whose performance indexes are equivalent to the ones of equivalent systems working on conventional RGB images.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Sensor Arrays: A Comprehensive Systematic Review

  • Domínguez-Gimeno, Sergio
  • Igual-Catalán, Raúl
  • Plaza-García, Inmaculada
Sensor arrays are arrangements of sensors that follow a certain pattern, usually in a row–column distribution. This study presents a systematic review on sensor arrays. For this purpose, several systematic searches of recent studies covering a period of 10 years were performed. As a result of these searches, 361 papers have been analyzed in detail. The most relevant aspects for sensor array design have been studied. In relation to sensing technologies, different categories were identified: resistive/piezoresistive, capacitive, inductive, diode-based, transistor-based, triboelectric, fiber optic, Hall effect-based, piezoelectric, and bioimpedance-based. Other aspects of sensor array design have also been analyzed: applications, validation experiments, software used for sensor array data analysis, sensor array characteristics, and performance metrics. For each aspect, the studies were classified into different subcategories. As a result of this analysis, different emerging technologies and future research challenges in sensor arrays were identified.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A new approach for real-time center-of-pressure correction in pressure sensitive mats using feedforward neural networks

  • Domínguez Gimeno, Sergio
  • Igual Catalán, Raúl
  • Medrano Sánchez, Carlos
  • Plaza García, Inmaculada
  • Martínez Cesteros, Javier
  • Pasetti, Marco
Center-of-pressure (CoP) is a good clinical indicator in balance tests and fall-risk assessment. It can be detected using pressure sensitive mats (PSMs), which are affordable. However, these can suffer from certain nonidealities, such as hysteresis and creep. These effects have been assessed in literature. However, proposed algorithms have low computation speed and are complex. In this work, a completely new approach based on feedforward neural networks (FFNNs) is proposed with the goal of correcting the CoP given by PSMs, allowing real-time correction. Its performance is compared in terms of error and computation times with a state-of-the-art model, which corrects for hysteresis and creep in the PSM. Results show that FFNN can correct for the CoP measurements, providing a good accuracy-speed balance.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Characterization and Comparison of Piezoresistive Materials and Their Performance on Pressure-Sensitive Mats

  • Martínez-Cesteros, Javier
  • Domínguez-Gimeno, Sergio
  • Castellanos-Ramos, Julián
  • Sánchez-Durán, José A.
  • Medrano-Sánchez, Carlos
The response of three readily available low-cost piezoresistive materials (EeonTex, Ex-Static, and Velostat) and their performance on a specific application were studied in this work. First, a series of pressure cycles was applied with a pneumatic platform on piezoresistive sensors based on them. These experiments allowed quantifying several nonidealities: Variability, drift, creep, hysteresis, nonlinearity, and response time. An overview radar chart showed that hysteresis, variability, and response time were quantitatively more relevant and different between the materials. Then, pressure-sensitive mats (PSMs) were manufactured using each of those three materials. They were evaluated by measuring the center of pressure (CoP) in stability tests. A force platform (FP) served as a reference instrument. The best performance in this kind of experiment was obtained by the Velostat-based mat (trajectory distance of 0.021 versus 0.035 and 0.045 cm/sample for Ex-Static-based and EeonTexbased mats, respectively). This material also showed less response time (0.21 versus 0.42 and 0.50 s for Ex-Static and EeonTex, respectively) and hysteresis (0.11 versus 0.21 and 0.23 S/S for EeonTex and Ex-Static, respectively), although its variability was larger (0.137 versus 0.065 and 0.059 S/S for Ex-Static and EeonTex, respectively). These results indicate that response time and hysteresis have a major influence on the determination of the CoP. Further research should focus on compensating for these effects or finding sensor configurations that minimize them.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Adaptation of the Inverse of Equivalent Conductance Method for Crosstalk Compensation in Resistive Sensor Arrays With Parallel Readout

  • Domínguez-Gimeno, Sergio
  • Medrano-Sánchez, Carlos
  • Martínez-Cesteros, Javier
  • Igual-Catalán, Raul
  • Plaza-García, Inmaculada
Resistive sensor arrays (RSAs) are arrangements of resistive sensors formed by shared conductive rows and columns. Each sensor is read by selecting one row and column at the same time. The voltage divider circuit (VDC) is a basic circuit for RSA readout. Other circuits described in the literature allow several columns to be read at the same time, which is known as parallel readout. In this work, parallel readout is applied for the first time to VDCs, leading to a new readout circuit for RSAs: the parallel-VDC (P-VDC). This circuit has been theoretically analyzed and qualitatively compared to other readout circuits, showing several strengths such as simplicity, easy nonidealities compensation, and lower power consumption. Crosstalk is a major problem in RSAs, which appears due to the row–column selection method. It has been compensated by a novel adaptation of the inverse of equivalent conductance method, based on effective conductances instead of equivalent ones. The feasibility of this new method is assessed through both simulations and laboratory experiments with a physical prototype of the P-VDC. The results show that the P-VDC presents lower base error than the basic VDC, and faster data acquisition due to parallel readout. In addition, the impact of uncertainty on the method is evaluated, and quantitative comparisons were made with other state-of-the-art circuits, where it demonstrates competitive performance. Moreover, it has been applied to plantar pressure measurement with RSAs, proving to be a feasible approach.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Design and validation of an immersive virtual rehabilitation system for individuals with vestibular disorders: A feasibility study

  • Ibrahem-Altwijri, Abdulaziz
  • Albiol-Pérez, Sergio
  • Cortés-Vega, María-Dolores
  • García-Muñoz, Cristina
  • Sasián Ramírez de Arellano, Rocio
  • Gil Gómez, José Antonio
  • Lozano-Quilis, José-Antonio
  • Casuso-Holgado, María Jesús
Background Vestibular rehabilitation is an essential part of managing balance disorders, but traditional exercises can often be repetitive and demotivating for patients. This can reduce adherence and limit treatment outcomes. Objective This study aimed to assess the feasibility, usability, patient satisfaction, and safety of DizzyVR, an immersive virtual reality system designed to support vestibular rehabilitation. Preliminary data on its potential effects on clinical outcomes were also collected. Methods A prospective, single-arm feasibility study was conducted with ten participants diagnosed with various vestibular disorders. Each participant completed eight weekly sessions using DizzyVR. Feasibility was assessed through session attendance and completion rates. Usability, satisfaction, and safety were measured using the System Usability Scale, the User Satisfaction Evaluation Questionnaire, and the Simulator Sickness Questionnaire. Clinical measures included the Dizziness Handicap Inventory (DHI), Timed Up and Go (TUG) test, Activities-specific Balance Confidence (ABC) scale, and Functional Gait Assessment (FGA). Results Ten participants completed the training, with a high adherence rate (91.25%). Usability scores indicated good ease of use, and satisfaction scores were high. Mild adverse events such as nausea or disorientation were reported by three participants, but improved over time. Exploratory pre–post changes were observed in gait speed (TUG: p = 0.002), balance confidence (ABC: p = 0.007), and gait stability (FGA: p = 0.012). While DHI scores demonstrated a trend toward improvement, the change did not reach statistical significance (p = 0.081). Overall, participants reported feeling safe and expressed willingness to recommend and reuse the system. Conclusions The findings suggest that DizzyVR is a feasible, usable, and well-accepted tool that may complement conventional vestibular rehabilitation. The system appears to support patient motivation and safe participation while showing promising exploratory changes in balance and gait. Further studies with larger samples, control groups, and longer follow-up are recommended to confirm and expand on these promising preliminary results.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Development and Validation of a Simulation Framework for Acoustic Intensity Measurements Using Dual-Microphone Probes Under Moving Source and Probe Conditions

  • Martín Ferrer, Raúl
  • Palacios-Navarro, Guillermo
  • Ramos Lorente, Pedro
This work presents a comprehensive physics-based simulation framework designed to model and assess the performance of acoustic intensity dual-microphone probes under dynamic conditions. The measured quantity, acoustic intensity, is a vector representing the net flow of sound energy through a unit area, allowing for the estimation not only of the amount of energy transmitted but also its direction. This characteristic is of great interest for locating sound sources and evaluating the acoustic power radiated by a source enclosed within a bounding surface. To analyze the quality of the intensity determination, an acoustic propagation model was developed in a MATLAB R2025a environment that allows for the simulation of the generation, three-dimensional propagation, and measurement of sound signals under free-field conditions. The model incorporates moving sources and sensors, precise calculation of propagation delays, and simulation of triaxial probes, also allowing for sensor translations and rotations. From the simulated pressure signals, intensity estimates are obtained using time and frequency-domain methods, and the quality of the estimates is evaluated using error metrics against known geometric references. The results demonstrate the simulator’s ability to generate coherent and controlled datasets and highlight its usefulness as a tool for comparative analysis of intensity estimation methods and for predicting the performance of real probes in dynamic scenarios.