SISTEMA MICROFLUIDICO MODULAR PARA LA MEDIDA DE CONTAMINANTES PRIORITARIOS EN AGUAS SUPERFICIALES

TEC2016-79367-C2-1-R

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2016
Plan Estatal 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

IRTA Pubpro. Open Digital Archive
Publicación Artículo científico (JournalArticle)

Compact analytical flow system for the simultaneous determination of L-lactic and L-malic in red wines

  • Giménez-Gómez, Pablo
  • Gutiérrez-Capitán, Manuel
  • Capdevila, Fina
  • Puig-Pujol, Anna
  • Jiménez-Jorquera, Cecilia
  • Fernández-Sánchez, César
During the malolactic fermentation of red wines, L-malic acid is mainly converted to L-lactic acid. Both acids should be precisely measured during the entire process to guarantee the quality of the final wine, thus making real-time monitoring approaches of great importance in the winemaking industry. Traditional analytical methods based on laboratory procedures are currently applied and cannot be deployed on-site. In this work, we report on the design and development of a bi-parametric compact analytical flow system integrating two electrochemical biosensors that could be potentially applied in this scenario. The developed flow-system will allow for the first time the simultaneous measurement of both acids in real scenarios at the real-time and in remote way. Miniaturized thin-film platinum four-electrode chips are fabricated on silicon substrates by standard photolithographic techniques and further implemented in a polymeric fluidic structure. This includes a 15 µL flow cell together with the required fluidic channels for sample and reagent fluid management. The four-electrode chip includes counter and pseudo-reference electrodes together with two working electrodes. These are sequentially modified with electropolymerized polypyrrole membranes that entrap the specific receptors for selectively detecting both target analytes. The analytical performance of both biosensors is studied by chronoamperometry, showing a linear range from 5 × 10−6 to 1 × 10−4 M (LOD of 3.2 ± 0.3 × 10−6 M) and from 1 × 10−7 to 1 × 10−6 M (LOD of 6.7 ± 0.2 × 10−8 M) for the L-lactate and the L-malate, respectively. Both biosensors show long-term stability, retaining more than the 90% of their initial sensitivity after more than 30 days, this being a prerequisite for monitoring the whole process of the malolactic fermentation of the red wines (time between 20 and 40 days). The flow system performance is assessed with several wine samples collected during the malolactic fermentation process of three red wines, showing an excellent agreement with the results obtained with the standard method., info:eu-repo/semantics/publishedVersion
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Compact analytical flow system for the simultaneous determination of L-lactic and L-malic in red wines

  • Giménez-Gómez, Pablo
  • Gutiérrez-Capitán, Manuel
  • Capdevila, Fina
  • Puig-Pujol, Anna
  • Jiménez-Jorquera, Cecilia
  • Fernández Sánchez, César
During the malolactic fermentation of red wines, L-malic acid is mainly converted to L-lactic acid. Both acids should be precisely measured during the entire process to guarantee the quality of the final wine, thus making real-time monitoring approaches of great importance in the winemaking industry. Traditional analytical methods based on laboratory procedures are currently applied and cannot be deployed on-site. In this work, we report on the design and development of a bi-parametric compact analytical flow system integrating two electrochemical biosensors that could be potentially applied in this scenario. The developed flow-system will allow for the first time the simultaneous measurement of both acids in real scenarios at the real-time and in remote way. Miniaturized thin-film platinum four-electrode chips are fabricated on silicon substrates by standard photolithographic techniques and further implemented in a polymeric fluidic structure. This includes a 15 µL flow cell together with the required fluidic channels for sample and reagent fluid management. The four-electrode chip includes counter and pseudo-reference electrodes together with two working electrodes. These are sequentially modified with electropolymerized polypyrrole membranes that entrap the specific receptors for selectively detecting both target analytes. The analytical performance of both biosensors is studied by chronoamperometry, showing a linear range from 5 × 10-6 to 1 × 10-4 M (LOD of 3.2 ± 0.3 × 10-6 M) and from 1 × 10-7 to 1 × 10-6 M (LOD of 6.7 ± 0.2 × 10-8 M) for the L-lactate and the L-malate, respectively. Both biosensors show long-term stability, retaining more than the 90% of their initial sensitivity after more than 30 days, this being a prerequisite for monitoring the whole process of the malolactic fermentation of the red wines (time between 20 and 40 days). The flow system performance is assessed with several wine samples collected during the malolactic fermentation process of three red wines, showing an excellent agreement with the results obtained with the standard method., Funding text 1 We acknowledge the group of Dr. Iluminada Gallardo (Chemistry Department, Universitat Autònoma de Barcelona, Spain) for kindly helping us with the polypyrrole distillation process. This work used the Spanish ICTS Network MICRONANOFABS and was partly supported by the Spanish Ministry of Economy, Industry and Competitiveness. Funding text 2 P.G.-G. carried out the optimization and the validation of the bi-parametric compact analytical flow system with wine samples. F.C. and A.P.-P. carried out the wine samples selection and collection, as well as the analytical measurements with standard enzymatic methods. P.G.-G., M.G.-C., C.F.-S. and C.J.-J. managed and coordinated the execution of the research activity. All the authors prepared the draft. P.G.-G. and C.F.-S revised and edited the manuscript. C.J.-J. and C.F.-S. obtained the financial support to carry out the projects associated with the manuscript., Peer reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Compact analytical flow system for the simultaneous determination of L-lactic and L-malic in red wines

  • Giménez-Gómez, Pablo
  • Gutiérrez-Capitán, Manuel
  • Capdevila, Fina
  • Puig-Pujol, Anna
  • Jiménez-Jorquera, Cecilia
  • Fernández-Sánchez, César
During the malolactic fermentation of red wines, L-malic acid is mainly converted to L-lactic acid. Both acids should be precisely measured during the entire process to guarantee the quality of the final wine, thus making real-time monitoring approaches of great importance in the winemaking industry. Traditional analytical methods based on laboratory procedures are currently applied and cannot be deployed on-site. In this work, we report on the design and development of a bi-parametric compact analytical flow system integrating two electrochemical biosensors that could be potentially applied in this scenario. The developed flow-system will allow for the first time the simultaneous measurement of both acids in real scenarios at the real-time and in remote way. Miniaturized thin-film platinum four-electrode chips are fabricated on silicon substrates by standard photolithographic techniques and further implemented in a polymeric fluidic structure. This includes a 15 µL flow cell together with the required fluidic channels for sample and reagent fluid management. The four-electrode chip includes counter and pseudo-reference electrodes together with two working electrodes. These are sequentially modified with electropolymerized polypyrrole membranes that entrap the specific receptors for selectively detecting both target analytes. The analytical performance of both biosensors is studied by chronoamperometry, showing a linear range from 5 × 10−6 to 1 × 10−4 M (LOD of 3.2 ± 0.3 × 10−6 M) and from 1 × 10−7 to 1 × 10−6 M (LOD of 6.7 ± 0.2 × 10−8 M) for the L-lactate and the L-malate, respectively. Both biosensors show long-term stability, retaining more than the 90% of their initial sensitivity after more than 30 days, this being a prerequisite for monitoring the whole process of the malolactic fermentation of the red wines (time between 20 and 40 days). The flow system performance is assessed with several wine samples collected during the malolactic fermentation process of three red wines, showing an excellent agreement with the results obtained with the standard method., info:eu-repo/semantics/publishedVersion