Publicación Artículo científico (JournalArticle)

Equilibrium optimiser tuned frequency-shifted internal model control proportional-derivative decoupled dual-loop design for industrial plants followed by experimental validation

  • Aryan, Pulakraj
  • Vilanova, Ramon|||0000-0002-8035-5199
  • Raja, G. Lloyds
Integrating and unstable processes require rugged control demand by virtue of their non-self-regulation character. The occurrence of system poles located at the origin and on the right half of the complex frequency plane causes instability in an open-loop configuration. When these processes proceed with dead time, it demands more sophisticated control requirements. Therefore, binal-loop control schemes are recommended over single-loop controller schemes. For plants with prevalent unstable and integrating dynamics and dead time, a novel modified inferred internal model control-proportional derivative decoupled binal-loop control system is suggested. The inner-loop is controlled by the stabilising proportional derivative controller with Routh-Hurwitz stability constraints. The outer-loop contains an inferred internal model controller for reference-point tracking. The equilibrium optimiser is then used to minimise the integral squared error by tuning the inner and outer-loop controller settings in the confined search space. The suggested strategy delivers appreciable enhancement in the quantitative performance measures as compared to some of the contemporary control techniques. The effect of time-varying disturbance and robust stability analysis is also presented. Finally, utilising a magnetic levitation laboratory setup, the suggested method is experimentally verified using the hardware-in-loop method.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Adapting WWTP performance to seasonality and climate change, Temperature-driven strategies for enhanced nitrogen removal

  • Revollar, Silvana|||0000-0001-9869-6437
  • Meneses, Montse|||0000-0002-5846-2676
  • Vilanova, Ramon|||0000-0002-8035-5199
  • Francisco, Mario|||0000-0002-6505-0936
  • Vega, Pastora|||0000-0002-3504-2273
A Temperature Driven Control Strategy that combines modifications on DO set-point, external carbon dosage and Solids Retention Time (SRT) is proposed to address the effect of seasonal and abnormal variations of temperature in the operation of Wastewater Treatment Plants. The medium-sized municipal WWTP, represented by Benchmark Simulation Model No. 2 (BSM2) that includes a Nitrogen Removal Activated Sludge Process (N-Removal ASP) with Dissolved Oxygen (DO) control has been selected as reference plant. The objective is to formulate a control strategy that improves the efficiency of the N-Removal ASP despite seasonal and unexpected variations of temperature of the influent, considering the trade-offs between temperature effects and control action effects on dynamic behavior. Simulations were carried out to evaluate the temperature and control actions effects on global average and dynamic behavior over a 30 days operation window, considering the BSM2 range from 10°C to 20 °C. A comprehensive analysis is carried out to look for potential solutions to improve performance at different temperature scenarios through the proper adjustment of DO set-points, carbon addition and sludge retention time (SRT). At low temperatures, the control actions are selected to improve N-Removal balance, since nitrification and denitrification rates are slowed producing violations of effluent quality limits in the presence of strong disturbances in influent flowrate. At high temperatures operational goals are to reduce the electricity consumption and the use of chemicals (external carbon), maintaining satisfactory performance. The Temperature Driven Control Strategy with different settings was tested considering a one year operating period. The proposed strategy address satisfactorily the seasonal and unexpected changes of temperature modelled by the annual BSM2 influent profile, attaining an appropriated trade-off between effluent quality and electricity consumption. The violations of required total Nitrogen limits are reduced up to 50 % in frequency and 33 % in length, while violations of required ammonium limits are reduced up to 36 % in frequency and 40 % in length. Annual average ammonium levels are reduced up to 19 % and annual average total Nitrogen is reduced up to 11 %. All these improvements are attained together with a slight decrease on electricity consumption. The proposed strategy is evaluated in a simulation platform, but it can be the starting point for the formulation of temperature driven advanced control strategies able to face climate change effects in the operation of for full-scale WWTPs.