Pasar al contenido principal

RETOS DE ECONOMIA CIRCULAR PARA LA OPERACION Y EL CONTROL DEL SISTEMA INTEGRADO DE AGUAS

PID2019-105434RB-C33

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2019
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD AUTONOMA DE BARCELONA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 16
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Equilibrium optimiser tuned frequency-shifted internal model control proportional-derivative decoupled dual-loop design for industrial plants followed by experimental validation

  • Aryan, Pulakraj
  • Vilanova, Ramon|||0000-0002-8035-5199
  • Raja, G. Lloyds
Integrating and unstable processes require rugged control demand by virtue of their non-self-regulation character. The occurrence of system poles located at the origin and on the right half of the complex frequency plane causes instability in an open-loop configuration. When these processes proceed with dead time, it demands more sophisticated control requirements. Therefore, binal-loop control schemes are recommended over single-loop controller schemes. For plants with prevalent unstable and integrating dynamics and dead time, a novel modified inferred internal model control-proportional derivative decoupled binal-loop control system is suggested. The inner-loop is controlled by the stabilising proportional derivative controller with Routh-Hurwitz stability constraints. The outer-loop contains an inferred internal model controller for reference-point tracking. The equilibrium optimiser is then used to minimise the integral squared error by tuning the inner and outer-loop controller settings in the confined search space. The suggested strategy delivers appreciable enhancement in the quantitative performance measures as compared to some of the contemporary control techniques. The effect of time-varying disturbance and robust stability analysis is also presented. Finally, utilising a magnetic levitation laboratory setup, the suggested method is experimentally verified using the hardware-in-loop method.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Reducing the Environmental Impact of Sewer Network Overflows Using Model Predictive Control Strategy

  • Vasiliev, Iulian|||0000-0003-2791-0824
  • Luca, Laurentiu|||0000-0002-7743-6772
  • Barbu, Marian|||0000-0001-6645-3705
  • Vilanova, Ramon|||0000-0002-8035-5199
  • Caraman, Sergiu Viorel
This paper proposes a method for reducing the environmental impact of sewer network (SN) overflows. The main objective of the paper is to minimize the wastewater quantity and the pollutant loads that overflow from the SN. The proposed algorithm to achieve this goal is Model Predictive Control using Particle Swarm Optimization as optimization method. It was tested in simulation using a simplified model of the network based on Benchmark Simulation Modelsewer as prediction model, and a forecasted influent. Three cases have been considered: (a) the fitness function is defined as the global yearly overflow volume calculated using equal weights for each tank; (b) the fitness function uses different weights for each tank depending on the medium loads and (c) integrating a penalty term related to the system state at the end of the prediction horizon in the previous fitness function. The simplified model determined a significant reduction of the integration time minimizing the optimization time.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

LSTM-Based Neural Network Controllers as Drop-In Replacements for PI Controllers in a Wastewater Treatment Plant

  • Adil, Muhammad|||0000-0002-4920-3875
  • Vilanova, Ramon|||0000-0002-8035-5199
Wastewater Treatment Plants (WWTPs) rely on automatic control strategies to regulate pollutant concentrations and comply with environmental standards. Among them, Proportional Integral (PI) controllers are widely adopted for their simplicity and robustness, yet their effectiveness is limited by the nonlinear and time-varying dynamics of biological processes. In this work, Long Short-Term Memory (LSTM)-based Artificial Neural Network (ANN) PI controllers are proposed as data-driven replacements for conventional PIs in key WWTP feedback loops. Using the Benchmark Simulation Model No. 1 (BSM1), ANN controllers were trained to replicate the behavior of default nitrate and nitrite nitrogen ((Formula presented.)) and dissolved oxygen ((Formula presented.)) loops, under both time-agnostic and time-aware strategies with three- and four-input configurations. The four-input time-aware model delivered the best results, reproducing PI behavior with high accuracy (coefficient of determination, (Formula presented.)) and considerably reducing control errors. For instance, under storm influent conditions, the (Formula presented.) controller reduced the Integral of Squared Error ((Formula presented.)) and Integral of Absolute Error ((Formula presented.)) by 84.7% and 68.4%, respectively, compared with the default PI. Beyond loop-level improvements, a Transfer Learning (TL) extension was explored: the trained (Formula presented.) controller was directly applied to additional aerated reactors ((Formula presented.) and (Formula presented.)) without retraining, replacing fixed aeration and demonstrating adaptability while reducing design effort. Plant-wide evaluation with the (Formula presented.) loop and three dissolved oxygen loops ((Formula presented.) - (Formula presented.)), all controlled by LSTM-based PI controllers, under storm influent conditions, showed further reductions in the Effluent Quality Index ((Formula presented.)) and the Overall Cost Index ((Formula presented.)) by 0.84% and 1.47%, respectively, highlighting simultaneous gains in effluent quality and operational economy. Additionally, the actuator and energy analyses showed that the LSTM-based controllers produced realistic and smooth control signals, maintained consistent energy use, and ensured stable overall operation, confirming the practical feasibility of the proposed approach.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Adapting WWTP performance to seasonality and climate change, Temperature-driven strategies for enhanced nitrogen removal

  • Revollar, Silvana|||0000-0001-9869-6437
  • Meneses, Montse|||0000-0002-5846-2676
  • Vilanova, Ramon|||0000-0002-8035-5199
  • Francisco, Mario|||0000-0002-6505-0936
  • Vega, Pastora|||0000-0002-3504-2273
A Temperature Driven Control Strategy that combines modifications on DO set-point, external carbon dosage and Solids Retention Time (SRT) is proposed to address the effect of seasonal and abnormal variations of temperature in the operation of Wastewater Treatment Plants. The medium-sized municipal WWTP, represented by Benchmark Simulation Model No. 2 (BSM2) that includes a Nitrogen Removal Activated Sludge Process (N-Removal ASP) with Dissolved Oxygen (DO) control has been selected as reference plant. The objective is to formulate a control strategy that improves the efficiency of the N-Removal ASP despite seasonal and unexpected variations of temperature of the influent, considering the trade-offs between temperature effects and control action effects on dynamic behavior. Simulations were carried out to evaluate the temperature and control actions effects on global average and dynamic behavior over a 30 days operation window, considering the BSM2 range from 10°C to 20 °C. A comprehensive analysis is carried out to look for potential solutions to improve performance at different temperature scenarios through the proper adjustment of DO set-points, carbon addition and sludge retention time (SRT). At low temperatures, the control actions are selected to improve N-Removal balance, since nitrification and denitrification rates are slowed producing violations of effluent quality limits in the presence of strong disturbances in influent flowrate. At high temperatures operational goals are to reduce the electricity consumption and the use of chemicals (external carbon), maintaining satisfactory performance. The Temperature Driven Control Strategy with different settings was tested considering a one year operating period. The proposed strategy address satisfactorily the seasonal and unexpected changes of temperature modelled by the annual BSM2 influent profile, attaining an appropriated trade-off between effluent quality and electricity consumption. The violations of required total Nitrogen limits are reduced up to 50 % in frequency and 33 % in length, while violations of required ammonium limits are reduced up to 36 % in frequency and 40 % in length. Annual average ammonium levels are reduced up to 19 % and annual average total Nitrogen is reduced up to 11 %. All these improvements are attained together with a slight decrease on electricity consumption. The proposed strategy is evaluated in a simulation platform, but it can be the starting point for the formulation of temperature driven advanced control strategies able to face climate change effects in the operation of for full-scale WWTPs.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Sintonía de controladores PID: un enfoque analítico basado en el moldeo de la función de sensibilidad, PID Tuning: Analytical approach based on the weighted Sensitivity problem

  • Vilanova, R.
  • Alcántara, S.
  • Pedret, C.
[EN] The PID controller is the most common option in the realm of control applications and is dominant in the process control industry. Among the related analytical methods, Internal Model Control (IMC) has gained remarkable industrial acceptance due to its robust nature and good set-point responses. However, the traditional application of IMC results in poor load disturbance rejection for lag-dominant and integrating plants. This work presents an IMC-like design method which avoids this common pitfall and is devised to work well for plants of modest complexity, for which analytical PID tuning is plausible. For simplicity, the design only focuses on the closed-loop sensitivity function. The approach provides model-based tuning of single-loop PID controllers in terms of the robustness/performance and servo/regulator trade-offs. Although the robustness/performance compromise is commonly considered, it is not so common to also take into account, for example, the conflict between input and output disturbances, referred also as the servo/regulator trade-off. As interested in providing a unified tuning approach, it is shown how the proposed methodology allows to deal with different process dynamics in a unified way., [ES] El controlador PID es la opción más común en el ámbito de las aplicaciones de control, siendo la opción predominante en el control de procesos industriales. Entre los métodos analíticos más usuales utilizados para su diseño, el Control por Modelo Interno (IMC) ha ganado una notable aceptación industrial debido a su naturaleza robusta y buenas respuestas ante cambios de consigna. Sin embargo, la aplicación tradicional del IMC da como resultado un bajo rendimiento para el rechazo de perturbaciones en carga para plantas integradoras y/o con largas constantes de tiempo. Este trabajo presenta un método de diseño, basado en IMC, que evita esta deficiencia y está diseñado para funcionar bien en plantas de complejidad moderada para las cuales, por otro lado, el ajuste analítico de un controlador PID es plausible. Por simplicidad, el diseño solo se centra en la función de sensibilidad en lazo cerrado. El enfoque proporciona un ajuste basado en modelo en términos de los compromisos robustez/rendimiento y de servo/regulación. Aunque comúnmente se considera el compromiso robustez/rendimiento, no es tan común tener en cuenta también, por ejemplo, el conflicto entre las perturbaciones de entrada y salida, también conocido como el compromiso servo/regulación. Con el objetivo de proporcionar un enfoque de ajuste unificado, se muestra como la metodología propuesta permite tratar diferentes dinámicas de proceso de manera unificada., Los autores desean agradecer al Ministerio de Economía y Competitividad bajo las subvenciones DPI-2016-77271-R y PID2019-105434RB-C33 por la ayuda que han supuesto en la elaboración de los trabajos que han conducido a los desarrollos aquí presentados.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Eco-Efficiency Assessment of Control Actions in Wastewater Treatment Plants

  • Revollar, Silvana|||0000-0001-9869-6437
  • Meneses, Montse|||0000-0002-5846-2676
  • Vilanova, Ramon|||0000-0002-8035-5199
  • Vega, Pastora|||0000-0002-3504-2273
  • Francisco, Mario|||0000-0002-6505-0936
This work explores the possibilities of improving the eco-efficiency of Wastewater Treatment Plants (WWTPs) introducing a plant-wide perspective in the formulation of the control strategy. Eco-efficiency goals are contemplated in the analysis of the appropriateness of control actions, considering the seasonal effects of temperature into the decision-making process. Plant-wide control strategy handles are the operation variables of the activated sludge process, the volume of the primary clarifier, and the temperature of the anaerobic digester. Performance is evaluated in terms of energy use, biogas production, effluent quality, emissions to air and soil, considering annual and bimestrial average values of indicators to capture seasonal effect of temperature. The result is a set of possible solutions, obtained from a multi-objective decision-making procedure, consisting on a sequence of control actions applied at different temporal windows that improve the eco-efficiency indicators of the plant. The results obtained when applying the different solutions make evident how the application of plant-wide control strategies is useful to improve performance indicators that represent individual goals, leading to trade-off solutions that describe WWTPs' eco-efficiency.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

New approach for regulation of the internal recirculation flow rate by fuzzy logic in biological wastewater treatments

  • Santín López, Ignacio|||0000-0002-4312-1035
  • Vilanova, Ramon|||0000-0002-8035-5199
  • Pedret Ferré, Carles|||0000-0001-8633-2548
  • Barbu, Marian|||0000-0001-6645-3705
The internal recirculation plays an important role on the different biological processes of wastewater treatment plants because it has a great influence on the concentration of pollutants, especially nutrients. Usually, the internal recirculation flow rate is kept fixed or manipulated by control techniques to maintain a fixed nitrate set-point in the last anoxic tank. This work proposes a new control strategy to manipulate the internal recirculation flow rate by applying a fuzzy controller. The proposed controller takes into account the effects of the internal recirculation flow rate on the inlet of the biological treatment and on the denitrification and nitrification processes with the aim of reducing violations of legally established limits of nitrogen and ammonia and also reducing operational costs. The proposed fuzzy controller is tested by simulation with the internationally known benchmark simulation model no. 2. The objective is to apply the proposed fuzzy controller in any control strategy, only replacing the manipulation of the internal recirculation flow rate, to improve the plant operation.Therefore, it has been implemented in five operation strategies from the literature, replacing their original internal recirculation flow rate control, and simulation results are compared with those of the original strategies. Results show improvements with the application of the proposed fuzzy controller of between 2.25 and 57.94% in reduction of total nitrogen limit violations, between 55.22 and 79.69% in reduction of ammonia limit violations and between 0.84 and 38.06% in cost reduction of pumping energy.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Transfer learning in wastewater treatment plant control design, from conventional to long short-term memory-based controllers

  • Pisa, Ivan|||0000-0003-3931-9257
  • Morell, Antoni|||0000-0003-2249-8594
  • Vilanova, Ramon|||0000-0002-8035-5199
  • Lopez Vicario, Jose|||0000-0002-3574-4697
In the last decade, industrial environments have been experiencing a change in their control processes. It is more frequent that control strategies adopt Artificial Neural Networks (ANNs) to support control operations, or even as the main control structure. Thus, control structures can be directly obtained from input and output measurements without requiring a huge knowledge of the processes under control. However, ANNs have to be designed, implemented, and trained, which can become complex and time-demanding processes. This can be alleviated by means of Transfer Learning (TL) methodologies, where the knowledge obtained from a unique ANN is transferred to the remaining nets reducing the ANN design time. From the control viewpoint, the first ANN can be easily obtained and then transferred to the remaining control loops. In this manuscript, the application of TL methodologies to design and implement the control loops of a Wastewater Treatment Plant (WWTP) is analysed. Results show that the adoption of this TL-based methodology allows the development of new control loops without requiring a huge knowledge of the processes under control. Besides, a wide improvement in terms of the control performance with respect to conventional control structures is also obtained. For instance, results have shown that less oscillations in the tracking of desired set-points are produced by achieving improvements in the Integrated Absolute Error and Integrated Square Error which go from 40.17% to 94.29% and from 34.27% to 99.71%, respectively.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Anaerobic digestion process control using a data-driven internal model control method

  • Condrachi, Larisa
  • Vilanova, Ramon|||0000-0002-8035-5199
  • Meneses, Montse|||0000-0002-5846-2676
  • Barbu, Marian|||0000-0001-6645-3705
Anaerobic digestion processes offer the possibility for wastewater treatment while obtaining a benefit through the obtained biogas. This paper aims to continue the effort to adopt data-driven control methods in the case of anaerobic digestion processes. The paper proposes a data-based Internal Model Control approach applied to an anaerobic digestion process. The paper deals extensively with the issue of choosing the reference model and proposing an engineering approach to this issue. The paper also addresses the issue of verifying robust stability, a very important aspect considering the uncertainties that characterize bioprocesses in general. The approach proposed in the paper is validated through a numerical simulation using the Anaerobic Digestion Model No. 1. During the validation of the proposed control solution, the main operating conditions were analyzed, such as the setpoint tracking performance, the rejection of disturbance generated by variations in the influent concentration, and the effect of the measurement noise on the controlled variable.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Design of feedback control strategies in a plant-wide wastewater treatment plant for simultaneous evaluation of economics, energy usage, and removal of nutrients

  • Sheik, Abdul
  • Tejaswini, Egalapati
  • Seepana, Murali
  • Ambati, Seshagiri
  • Meneses, Montse|||0000-0002-5846-2676
  • Vilanova, Ramon|||0000-0002-8035-5199
Simultaneous removal of nitrogen and phosphorous is a recommended practice while treating wastewater. In the present study, control strategies based on proportional-integral (PI), model predictive control (MPC), and fuzzy logic are developed and implemented on a plant-wide wastewater treatment plant. Four combinations of control frameworks are developed in order to reduce the operational cost and improve the effluent quality. As a working platform, a Benchmark simulation model (BSM2-P) is used. A default control framework with PI controllers is used to control nitrate and dissolved oxygen (DO) by manipulating the internal recycle and oxygen mass trans-fer coefficient (KLa). Hierarchical control topology is proposed in which a lower-level control framework with PI controllers is implemented to DO in the sixth reactor by regulating the KLa of the fifth, sixth, and seventh reactors, and fuzzy and MPC are used at the supervisory level. This supervisory level considers the ammonia in the last aerobic reactor as a feedback signal to alter the DO set-points. PI-fuzzy showed improved effluent quality by 21.1%, total phosphorus removal rate by 33.3% with an increase of operational cost, and a slight increase in the production rates of greenhouse gases. In all the control design frameworks, a trade-off is observed between operational cost and effluent quality.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Optimal Control Strategy of a Sewer Network

  • Vasiliev, Iulian|||0000-0003-2791-0824
  • Luca, Laurentiu|||0000-0002-7743-6772
  • Barbu, Marian|||0000-0001-6645-3705
  • Vilanova, Ramon|||0000-0002-8035-5199
  • Caraman, Sergiu
This paper proposes a series of methods to increase the efficiency of the operating of a sewer network that serves a medium-sized city with a population of 250,000 inhabitants. The sewer network serves five areas of the city and consists of seven tanks that communicate with one another and with the treatment plant through pipes. The controls are applied to the process by valves and pumps. The main objective of this paper is to determine the optimal controls to minimize two performance criteria: volume of overflow, and overflow quality index. The sewer network was modeled in the BSMSewer environment. The optimization of the operating of the sewer network was carried out in the conditions of an influent computed in relation to the number of inhabitants and to the area served, using genetic algorithms as a method of optimization. Five optimization strategies were analyzed by numerical simulation. The analysis of the five strategies was done by comparison of their results with one another, as well as in relation to the case where all of the controls were set at maximum values of 100%. The simulations showed that the third strategy produced the best results in relation to each of the two criteria.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

FOPI/FOPID tuning rule based on a fractional order model for the process

  • Meneses, Helber|||0000-0001-7119-3100
  • Arrieta Orozco, Orlando|||0000-0002-4004-8573
  • Padula, Fabrizio|||0000-0002-0013-9526
  • Visioli, Antonio|||0000-0002-9246-5715
  • Vilanova, Ramon|||0000-0002-8035-5199
This paper deals with the design of a control system based on fractional order models and fractional order proportional-integral-derivative (FOPID) controllers and fractional-order proportional-integral (FOPI) controllers. The controller design takes into account the trade-off between robustness and performance as well as the trade-off between the load disturbance rejection and set-point tracking tasks. The fractional order process model is able to represent an extensive range of dynamics, including over-damped and oscillatory behaviors and this simplifies the process modelling. The tuning of the FOPID and FOPI controllers is achieved by using an optimization, as a first step, and in a second step, several fitting functions were used to capture the behavior of the optimal parameters of the controllers. In this way, a new set of tuning rules called FOMCoRoT (Fractional Order Model and Controllers Robust Tuning) is obtained for both FOPID and FOPI controllers. Simulation examples show the effectiveness of the proposed control strategy based on fractional calculus.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Transfer Learning in wastewater treatment plants control, Measuring the transfer suitability

  • Pisa, Ivan|||0000-0003-3931-9257
  • Morell, Antoni|||0000-0003-2249-8594
  • Lopez Vicario, Jose|||0000-0002-3574-4697
  • Vilanova, Ramon|||0000-0002-8035-5199
The industrial sector is nowadays experiencing a digital transformation motivated by the Industry 4.0 paradigm. Concepts such as data-driven models, Artificial Neural Networks (ANNs), and Transfer Learning (TL) are part of the current vocabulary in the industrial management and control topics. For that reason, in this paper the application of TL techniques is proposed to derive new ANN-based control structures from pre-existing ones. Notice that if an ANN-based controller is transferred into a new industrial environment, its appropriate behaviour must be ensured, and what it is more important, this must be known a priori. Nevertheless, TL techniques do not always ensure this. That is why the Transfer Suitability Metric (TSM) is proposed here. Determining the similarity among environments, this metric tells if the controller can be transferred, transferred with certain limitations, or if it cannot be transferred at all. Here, the metric is applied over a Wastewater Treatment Plant (WWTP). The objective is to derive the control structure of one control loop, let us say the Dissolved Oxygen (DO), and then transfer it into another basic control loop in a WWTP, the Nitrate-nitrogen (NO), and vice-versa. Results show that with the help of the TSM, an improvement around a 68.54% and 80.53% in the Integrated Absolute Error (IAE) and the Integrated Squared Error (ISE) is obtained in the NO management, respectively. Moreover, a simplification and speed-up of the controller design process is achieved.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Model-Based Optimization Approach for PID Control of Pitch-Roll UAV Orientation

  • Arrieta Orozco, Orlando|||0000-0002-4004-8573
  • Campos, Daniel|||0000-0003-1982-3288
  • Rico-Azagra, Javier|||0000-0002-5500-6093
  • Gil-Martínez, Montserrat|||0000-0002-6547-5301
  • Rojas, José David|||0000-0003-1176-9061
  • Vilanova, Ramon|||0000-0002-8035-5199
This study focuses on the modeling and control optimization of the pitch-roll angles orientation in a quad-rotor UAV (unmanned aerial vehicle) drone system. To address the control challenge, PID (proportional-integral-derivative) controllers are used, which have been tuned through a model-based optimization approach. A non-linear model of the system is obtained and further validated experimentally. The model is implemented in Simulink to conduct model-based optimization. The controller design uses an IMC (internal model control) model-based approach to establish the initial parameters for a PID controller. In the subsequent design phase, a multiobjective approach is taken, incorporating weighted cost functions that account for IAE (integral absolute error) and ITAE (integral of time-weighted absolute error) forms, along with battery usage. The outcomes of this design are showcased through simulations and real-world platform testing.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Nitrous oxide reduction in wastewater treatment plants by the regulation of the internal recirculation flow rate with a fuzzy controller

  • Santín López, Ignacio|||0000-0002-4312-1035
  • Meneses, Montse|||0000-0002-5846-2676
  • Pedret Ferré, Carles|||0000-0001-8633-2548
  • Barbu, Marian|||0000-0001-6645-3705
  • Vilanova, Ramon|||0000-0002-8035-5199
The reduction of greenhouse gas emissions due to anthropogenic causes is one of the world's main challenges to face climate change. Wastewater treatment plants are necessary to improve the quality of wastewater before it is discharged into the receiving environment, but they have the disadvantage of generating nitrous oxide emissions during the biological treatment, which is a potent greenhouse gas. Avoiding partial nitrification by increasing dissolved oxygen is one of the ways to reduce these emissions. However, this article proposes to face a reduction of nitrous oxide emissions by reducing oxygen to minimum levels causing heterotrophic microorganisms to reduce nitrous oxide to dinitrogen. To achieve this objective, the present work proposes a regulation of the internal recirculation flow rate of the biological treatment by means of a fuzzy controller. This regulation is added to a usual control strategy in wastewater treatment plants, which achieves satisfactory results with respect to water quality and operational costs but that generates high nitrous oxide emissions. The Benchmark Simulation Model no. 2 Gas is used as working scenario, which includes the two main nitrous oxide emission pathways: heterotrophic denitrification and ammonia oxidizing bacteria denitrification. The proposed internal recirculation manipulation is shown to achieve nitrous oxide reductions of 26.70 and 30.83 % in different time periods with a slight effluent quality improvement and an operational cost reduction.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Design a Robust Proportional-Derivative Gain-Scheduling Control for a Magnetic Levitation System

  • Almobaied, Moayed|||0000-0001-7912-2673
  • Al-Nahhal, Hassan|||0000-0003-0547-542X
  • Arrieta Orozco, Orlando|||0000-0002-4004-8573
  • Vilanova, Ramon|||0000-0002-8035-5199
This study focuses on the design of a robust PD gain-scheduling controller (PD-GS-C) for an unstable SISO (single-input, single-output) magnetic levitation system with two electromagnets (MLS2EM). Magnetic levitation systems offer various advantages, including friction-free, reliable, fast, and cost-effective operations. However, due to their unstable and highly nonlinear nature, these systems require sophisticated feedback control techniques to ensure optimal performance and functionality. To address these challenges, in this study, we derive the nonlinear state-space mathematical model of the MLS2EM and linearize it around five different operating points. The PDGS-C controller aims to stabilize the system and improve steady-state control error. The strategy for obtaining the PD controller gains involves a parameter space technique, which specifies performance requirements. This technique results in ranges of proportional (KP) and derivative (KD) gains that are used by the PD-GS-C structure. To optimize the controller's performance further, we utilize the big bang-big crunch optimization technique (BB-BC) to determine the optimal PD gains within the specified ranges. The optimization process focuses on achieving optimal performance in terms of a specific performance index function. This function quantifies the system's time-domain step response criteria, which include minimizing overshoot percentage, settling time, and rising time. The index function is inversely proportional to the desired performance criteria, meaning that the goal is to maximize the index function to optimize the system's performance. To validate the effectiveness and viability of the proposed strategy, we conducts MATLAB simulations and real-time experiments. The simulations and experimental findings serve to demonstrate the controller's performance and verify its capabilities in stabilizing the MLS2EM magnetic levitation system.