Effects of sedatives and opioids on trigger and cycling asynchronies throughout mechanical ventilation, An observational study in a large dataset from critically ill patients

  • Haro López, Candelaria de|||0000-0002-2668-1030
  • Magrans, Rudys
  • López-Aguilar, Josefina|||0000-0003-2359-3980
  • Montanyà, Jaume
  • Lena, Enrico
  • Subirà, Carles|||0000-0003-2285-2311
  • Fernández-Gonzalo, Sol|||0000-0003-0267-0617
  • Gomà, Gemma|||0000-0002-1890-4855
  • Fernández, Rafael
  • Albaiceta, Guillermo M.|||0000-0002-9276-3253
  • Skrobik, Yoanna|||0000-0002-5315-6020
  • Lucangelo, Umberto
  • Murias, Gastón
  • Ochagavía Calvo, Ana|||0000-0002-0564-2913
  • Kacmarek, Robert M.
  • Rué, Montserrat|||0000-0002-7862-9365
  • Blanch, Lluís|||0000-0002-4158-7464
Background: In critically ill patients, poor patient-ventilator interaction may worsen outcomes. Although sedatives are often administered to improve comfort and facilitate ventilation, they can be deleterious. Whether opioids improve asynchronies with fewer negative effects is unknown. We hypothesized that opioids alone would improve asynchronies and result in more wakeful patients than sedatives alone or sedatives-plus-opioids. Methods: This prospective multicenter observational trial enrolled critically ill adults mechanically ventilated (MV).
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Predicting Patient-ventilator Asynchronies with Hidden Markov Models

  • Marchuk, Yaroslav
  • Magrans, Rudys
  • Sales, Bernat
  • Montanya, Jaume
  • López-Aguilar, Josefina|||0000-0003-2359-3980
  • Haro López, Candelaria de|||0000-0002-2668-1030
  • Gomà, Gemma|||0000-0002-1890-4855
  • Subirà, Carles|||0000-0003-2285-2311
  • Fernández, Rafael
  • Kacmarek, Robert M.
  • Blanch, Lluís|||0000-0002-4158-7464
In mechanical ventilation, it is paramount to ensure the patient's ventilatory demand is met while minimizing asynchronies. We aimed to develop a model to predict the likelihood of asynchronies occurring. We analyzed 10,409,357 breaths from 51 critically ill patients who underwent mechanical ventilation.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Automatic detection of ventilatory modes during invasive mechanical ventilation

  • Murias, Gastón
  • Montanyà, Jaume
  • Chacón, Encarna
  • Estruga, Anna
  • Subirà, Carles|||0000-0003-2285-2311
  • Fernández, Rafael
  • Sales, Bernat
  • Haro López, Candelaria de|||0000-0002-2668-1030
  • López-Aguilar, Josefina|||0000-0003-2359-3980
  • Lucangelo, Umberto
  • Villar, Jesús
  • Kacmarek, Robert M.
  • Blanch, Lluís|||0000-0002-4158-7464
Expert systems can help alleviate problems related to the shortage of human resources in critical care, offering expert advice in complex situations. Expert systems use contextual information to provide advice to staff. In mechanical ventilation, it is crucial for an expert system to be able to determine the ventilatory mode in use. Different manufacturers have assigned different names to similar or even identical ventilatory modes so an expert system should be able to detect the ventilatory mode. The aim of this study is to evaluate the accuracy of an algorithm to detect the ventilatory mode in use. We compared the results of a two-step algorithm designed to identify seven ventilatory modes. The algorithm was built into a software platform (BetterCare® system, Better Care SL; Barcelona, Spain) that acquires ventilatory signals through the data port of mechanical ventilators. The sample analyzed compared data from consecutive adult patients who underwent.