RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication
Artículo científico (JournalArticle)
Ductility of slender reinforced concrete columns under monotonic flexureand constant axial load
In this paper an investigation is presented based on tests results of reinforced concrete columns subjected
to monotonic flexure and constant axial load from a previous paper [1]. The variables of the tests were
strength of concrete (30, 60 and 90 MPa), shear span ratio (M/(V h) = 7.5, 10.5 and 15), axial load level
(0–45%), and transversal and longitudinal reinforcement ratio (1.4–3.2%). This paper is a continuation
of the aforementioned but focuses on the deformation capacity, which depends on the method selected
to idealize the response diagram comparing four of these methods. The results show that the parameters
affecting ductility are greatly influenced by the different methods. It was observed that the ductility in
displacements does not always decrease with axial load and column slenderness. In addition, a new equation
is proposed to obtain the ultimate displacement for slender columns.
2012 Elsevier Ltd. All rights reserved, The authors of this work wish to thank the Research Bureau of the Spanish Ministry of Science and Innovation and the Plan E, for the funding of the project BIA 2009-10207.