Skip to main content

CONVERTIDORES ELECTRONICOS AVANZADOS PARA INTEGRACION EN RED DE SISTEMAS FOTOVOLTAICOS Y EOLICOS

DPI2016-80641-R

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2016
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSIDAD PUBLICA DE NAVARRA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 19
Encontrada(s) 1 página(s)

Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Identification of critical parameters for the design of energy management algorithms for Li-ion batteries operating in PV power plants

  • Berrueta Irigoyen, Alberto
  • Soto Cabria, Adrián
  • Marcos Álvarez, Javier
  • Parra Laita, Íñigo de la
  • Sanchis Gúrpide, Pablo
  • Ursúa Rubio, Alfredo
Lithium-ion batteries are gaining importance for a variety of applications due to their price decrease and characteristics improvement. For a proper use of such storage systems, an energy management algorithm (EMA) is required. A number of EMAs, with various characteristics, have been published recently, given the diverse nature of battery problems. The EMA of deterministic battery problems is usually based on an optimization algorithm. The selection of such an algorithm depends on a few problem characteristics, which need to be identified and closely analyzed. The aim of this article is to identify the critical optimization problem parameters that determine the most suitable EMA for a Li-ion battery. With this purpose, the starting point is a detailed model of a Li-ion battery. Three EMAs based on the algorithms used to face deterministic problems, namely dynamic, linear, and quadratic programming, are designed to optimize the energy dispatch of such a battery. Using real irradiation and power price data, the results of these EMAs are compared for various case studies. Given that none of the EMAs achieves the best results for all analyzed cases, the problem parameters that determine the most suitable algorithm are identified to be four, i.e., desired computation intensity, characteristics of the battery aging model, battery energy and power capabilities, and the number of optimization variables, which are determined by the number of energy storage systems, the length of the optimization problem, and the desired time step., This work was supported in part by the European Union under the H2020 Project STARDUST under Grant 774094, in part by the Spanish State Research Agency and FEDER-UE under Grants DPI2016-80641-R, DPI2016-80642-R, PID2019-111262RB-I00, and PID2019-110956RB-I00, in part by the Government of Navarra through Research Project 0011-1411-2018-000029 GERA, and in part by the Public University of Navarre under Project ReBMS PJUPNA1904.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Maximum expected ramp rates using cloud speed sensor measurements

  • Wang, Guang Chao
  • Kurtz, Ben
  • Bosch, Juan Luis
  • Parra Laita, Íñigo de la
  • Kleissl, Jan
Large ramps and ramp rates in photovoltaic (PV) power output are of concern and sometimes even explicitly restricted by grid operators. Battery energy storage systems can smooth the power output and maintain ramp rates within permissible limits. To enable PV plant and energy storage system design and planning, a method to estimate the largest expected ramps for a given location is proposed. Because clouds are the dominant source of PV power output variability, an analytical relationship between the worst expected ramp rate, cloud motion vector, and the geometrical layout of the PV plant is developed. The ability of the proposed method to bracket actual ramp rates is assessed over 10 months under different meteorological conditions, demonstrating an average compliance rate of 98.9% for a 2 min evaluation time window. The largest observed ramp of 29.7% s(-1)is contained with the worst case estimate of 34.3% s(-1). This method provides a convenient yet economical approach to worst-case PV ramp rate modeling and is compatible with solar irradiance measured at coarse temporal resolution., Juan Bosch was financed in part by Project No. PID2019-108953RB-C21, funded by the Ministerio de Ciencia e Innovación and co-financed by the European Regional Development Fund. In addition, Iñigo de la Parra was partially supported by the Spanish State Research Agency (AEI) and FEDER-UE under Grant Nos. DPI2016-80641-R and DPI2016-80642-R.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Combined dynamic programming and region-elimination technique algorithm for optimal sizing and management of lithium-ion batteries for photovoltaic plants

  • Berrueta Irigoyen, Alberto
  • Heck, Michael
  • Jantsch, Martin
  • Ursúa Rubio, Alfredo
  • Sanchis Gúrpide, Pablo
The unpredictable nature of renewable energies is drawing attention to lithium-ion batteries. In order to make full utilization of these batteries, some research works are focused on the management of existing systems, while others propose sizing techniques based on business models. However, in order to optimise the global system, a comprehensive methodology that considers both battery sizing and management at the same time is needed. This paper proposes a new optimisation algorithm based on a combination of dynamic programming and a region elimination technique that makes it possible to address both problems at the same time. This is of great interest, since the optimal size of the storage system depends on the management strategy and, in turn, the design of this strategy needs to take account of the battery size. The method is applied to a real installation consisting of a 100 kWp rooftop photovoltaic plant and a Li-ion battery system connected to a grid with variable electricity price. Results show that, unlike conventional optimisation methods, the proposed algorithm reaches an optimised energy dispatch plan that leads to a higher net present value. Finally, the tool is used to provide a sensitivity analysis that identifies key informative variables for decision makers, The authors would like to acknowledge the support of the Spanish State Research Agency and FEDER-UE under grants DPI2016-80641-R and DPI2016-80642-R; of Government of Navarra through research project PI038 INTEGRA-RENOVABLES; and the FPU Program of the Spanish Ministry of Education, Culture and Sport (FPU13/00542).
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Common-mode and phase-to-ground voltage reduction in back-to-back power converters with discontinuous PWM

  • Samanes Pascual, Javier
  • Gubía Villabona, Eugenio
  • Juankorena Saldias, Xabier
  • Gironés Remírez, Carlos
Discontinuous space vector pulsewidth modulation (DSVPWM) techniques are an interesting option for three-phase, two-level power converters when efficiency is a key factor. Such is the case of back-to-back (B2B) power converters used mainly in wind energy conversion systems and electrical drives. The application of DSVPWMs to B2B converters increases the common-mode (CM) and phase-to-ground (PG) voltages by 50%, compared to conventional space vector pulsewidth modulation (SVPWM7). Higher CM and PG voltages cause bearing currents and insulation stress, which reduce system reliability. In this article, this problem is addressed and two DSVPWM strategies are presented to reduce the CM and PG voltages in B2B power converters. In the first proposal, the CM and PG are both limited to the same values as the conventional SVPWM7 without introducing additional commutations. In the second proposal, a further modification is added to reduce the CM by 50%, compared to the SVPWM7, although this modulation strategy eventually requires two additional commutations in certain periods. Experimental and simulation results validate the performance of the proposed strategies., This work has been supported by the Spanish State Research Agency (AEI) and FEDER-UE under grant DPI2016-80641-R.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Robust multisampled capacitor voltage active damping for grid-connected power converters

  • Samanes Pascual, Javier
  • Urtasun Erburu, Andoni
  • Gubía Villabona, Eugenio
  • Petri, Alberto
The derivative feedback of the capacitor voltage is one of the most extended active damping strategies, used to eliminate stability problems in grid-connected power converters with an LCL filter. This strategy is equivalent to the implementation of a virtual impedance in parallel with the filter capacitor. This virtual impedance is strongly affected by the control loop delays and frequency, creating changes in the sign of the emulated virtual resistor, and raising instability regions where the active damping is ineffective. As a consequence, the LCL resonance frequency is restricted to vary, as the effective grid inductance changes, within the active damping stability region. This is an additional restriction imposed on the LCL filter design that can compromise the achievement of an optimised design. For this reason, in this work, a different strategy is presented; by adjusting the delay in the active damping feedback path, it becomes stable within the range where the LCL resonance frequency can be located for a given filter design, achieving a robust damping. Analytical expressions are provided to adjust this delay. To widen the stability region of the capacitor voltage derivative active damping, a multisampled derivative is implemented, overcoming its limitations close to the control Nyquist frequency. Experimental and simulation results validate the active damping strategy presented., This work has been supported by the Spanish State Research Agency (AEI) and FEDER-UE under grant DPI2016-80641-R. This work was partially funded by the Public University of Navarre through a doctoral scholarship.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

A comprehensive model for lithium-ion batteries: from the physical principles to an electrical model

  • Berrueta Irigoyen, Alberto
  • Urtasun Erburu, Andoni
  • Ursúa Rubio, Alfredo
  • Sanchis Gúrpide, Pablo
The growing interest in e-mobility and the increasing installation of renewable energy-based systems are leading to rapid improvements in lithium-ion batteries. In this context, battery manufacturers and engineers require advanced models in order to study battery performance accurately. A number of Li-ion battery models are based on the representation of physical phenomena by electrochemical equations. Although providing detailed physics-based information, these models cannot take into account all the phenomena for a whole battery, given the high complexity of the equations. Other models are based on equivalent circuits and are easier to design and use. However, they fail to relate these circuit parameters to physical properties. In order to take the best of both modeling techniques, we propose an equivalent circuit model which keeps a straight correlation between its parameters and the battery electrochemical principles. Consequently, this model has the required simplicity to be used in the simulation of a whole battery, while providing the depth of detail needed to identify physical phenomena. Moreover, due to its high accuracy, it can be used in a wide range of environments, as shown in the experimental validations carried out in the final section of this paper., The authors acknowledge the support of the Spanish State Research Agency (AEI) and FEDER UE under grants DPI2013 42853 R, DPI2016 80641 R and DPI2016 80642 R; of Government of Navarra through research project PI038 INTEGRA-RENOVABLES; and the FPU Program of the Spanish Ministry of Education, Culture and Sport (FPU13/00542).
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Control of a photovoltaic array interfacing current-mode-controlled boost converter based on virtual impedance emulation

  • Urtasun Erburu, Andoni
  • Samanes Pascual, Javier
  • Barrios Rípodas, Ernesto
  • Sanchis Gúrpide, Pablo
  • Marroyo Palomo, Luis
Due to the nonlinear characteristics of a photovoltaic (PV) array, its regulation is highly dependent on the operating point. Focusing on a dc-dc boost converter, this paper first shows how the PV voltage and inductor current controls are affected by the PV array. It then proposes to emulate an impedance virtually connected to the PV array, making it possible to greatly improve the control robustness. Thanks to the proposed strategy, the crossover frequency variation for the whole operating range is reduced from 42 times for the traditional control to 3.5 times when emulating parallel resistance or to 1.4 times when emulating series and parallel resistances, all with simple implementation. Experimental results with a commercial PV inverter and a 4-kWp PV array validate the theoretical analysis and demonstrate the superior performance of the proposed control., This work was supported in part by Ingeteam Power Technology and in part by Spanish State Research Agency (AEI) FEDER-UE under Grant DPI2016-80641-R.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

The potential of forecasting in reducing the LCOE in PV plants under ramp-rate restrictions

  • Cirés Buey, Eulalia
  • Marcos Álvarez, Javier
  • Parra Laita, Íñigo de la
  • García Solano, Miguel
  • Marroyo Palomo, Luis
An increasing number of grid codes are requiring the limitation of the PV output power fluctuation over a given time scale. Batteries represent the most obvious solution to smooth power fluctuations, with the corresponding negative impact on the PV energy cost. However, short-term forecasting is currently being proposed as a tool to reduce battery capacity requirements or even completely remove it. Although these solutions decrease or avoid the battery cost, it also entails some energy curtailment losses which obviously raise the final cost of PV energy. This energy losses, currently unknown, are independent of the forecasting accuracy and represent the minimal additional cost in the hypothetical case of a perfect prediction. Thus, this paper compares Levelized Cost of Energy (LCOE) of three ramp-rate control strategies in order to determine which would give the lowest cost: battery-based, ideal short-term forecasting, or a combination of both. Results show that curtailment losses would be small enough to make battery-less strategy an appropriate choice, so it is worthwhile improving short-term forecasting in view of the potential LCOE savings. Database is taken from high resolution measurements recorded for over a year at 8 PV plants ranging from 1 to 46 MWp., The authors would like to thank ACCIONA for authorizing measurements at its PV plants and for the helpful collaboration of its staff. This work has been supported by the Spanish State Research Agency (AEI) and FEDER-UE (ERDF-EU) under grants DPI2016-80641-R and DPI2016-80642-R.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Experimental assessment of first- and second-life electric vehicle batteries: performance, capacity dispersion, and aging

  • Braco Sola, Elisa
  • San Martín Biurrun, Idoia
  • Berrueta Irigoyen, Alberto
  • Sanchis Gúrpide, Pablo
  • Ursúa Rubio, Alfredo
Nowadays, the reuse of electric vehicle batteries is considered to be a feasible alternative to recycling, as it allows them to benefit from their remaining energy capacity and to enlarge their lifetime. Stationary applications, such as self-consumption or off-grid systems support, are examples of second-life (SL) uses for retired batteries. However, reused modules that compose these batteries have heterogeneous properties, which limit their performance. This article aims to assess the influence of degradation in modules from electric vehicles, covering three main aspects: performance, capacity dispersion, and extended SL behavior. First, a complete characterization of new and reused modules is carried out, considering three temperatures and three discharge rates. In the second stage, intra- and intermodule capacity dispersions are evaluated with new and reused samples. Finally, the behavior during SL is also analyzed, through an accelerated cycling test so that the evolution of capacity and dispersion are assessed. Experimental results show that the performance of reused modules is especially undermined at low temperatures and high current rates, as well as in advanced stages of aging. The intramodule dispersion is found to be similar in reused and new samples, while the intermodule differences are nearly four times greater in SL., This work was supported in part by the Spanish State Research Agency (AEI) under Grant PID2019-111262RB-I00/AEI/10.13039/501100011033 and Grant DPI2016-80641-R, in part by the European Union under the H2020 Project STARDUST under Grant 774094, in part by the Government of Navarra under Research Project 0011-1411-2018-000029 GERA, and in part by the Public University of Navarre under Project ReBMS PJUPNA1904.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Cloud tomography applied to sky images: a virtual testbed

  • Mejía, Felipe A.
  • Kurtz, Ben
  • Levis, Aviad
  • Parra Laita, Íñigo de la
  • Kleissl, Jan
Two tomographic techniques are applied to two simulated sets of sky images with different cloud fraction. The Algebraic Reconstruction Technique (ART) is applied to optical depth maps from sky images to reconstruct 3-D cloud extinction coefficients without considering multiple scattering effects. Reconstruction accuracy is explored for different products, including surface irradiance and extinction coefficients, and as a function of the number of available sky imagers and setup distance. Increasing the number of imagers improves the accuracy of the 3-D reconstruction: for surface irradiance, the error decreases significantly up to four imagers at which point the improvements become marginal. But using nine imagers gives more robust results in practical situations in which the circumsolar region of images has to be excluded due to poor cloud detection. The ideal distance between imagers was also explored: for a cloud height of 1 km, increasing distance up to 3 km (the domain length) improved the 3-D reconstruction. An iterative reconstruction technique that iteratively updated the source function improved the results of the ART by minimizing the error between input red radiance images and reconstructed red radiance simulations. For the best case of a nine-imager deployment, the ART and iterative method resulted in 53.4% and 33.6% relative mean absolute error for the extinction coefficients, respectively., The authors acknowledge funding from the California Energy Commission EPIC program. Felipe Mejia was supported by the National Science Foundation Graduate Research Fellowship under Grant No. (DGE-1144086). In addition, Íñigo de la Parra has been partially supported by the Spanish State Research Agency (AEI) and FEDER-UE under grants DPI2016-80641-R and DPI2016-80642-R.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Supercapacitors: electrical characteristics, modelling, applications and future trends

  • Berrueta Irigoyen, Alberto
  • Ursúa Rubio, Alfredo
  • San Martín Biurrun, Idoia
  • Eftekhari, Ali
  • Sanchis Gúrpide, Pablo
Energy storage systems are playing an increasingly important role in a variety of applications, such as electric vehicles or grid-connected systems. In this context, supercapacitors (SCs) are gaining ground due to their high power density, good performance and long maintenance-free lifetime. For this reason, SCs are a hot research topic, and several papers are being published on material engineering, performance characterization, modelling and post-mortem analysis. A compilation of the most important millstones on this topic is essential to keep researchers on related fields updated about new potentials of this technology. This review paper covers recent research aspects and applications of SCs, highlighting the relationship between material properties and electrical characteristics. It begins with an explanation of the energy storage mechanisms and materials used by SCs. Based on these materials, the SCs are classified, their key features are summarised, and their electrochemical characteristics are related to electrical performance. Given the high interest in system modelling and the large number of papers published on this topic, modelling techniques are classified, explained and compared, addressing their strengths and weaknesses, and the experimental techniques used to measure the modelled properties are described. Finally, the market sectors in which SCs are successfully used, as well as their growth expectations are analysed. The analysis presented herein gives account of the expansion that SC market is currently undergoing and identifies the most promising research trends on this field., This work was supported in part by the Spanish State Research Agency (AEI) and FEDER UE under Grant DPI2016-80641-R and Grant DPI2016-80642-R, in part by the Government of Navarre through the Research Project PI020 RENEWABLE-STORAGE, and in part by the FPU Program of the Spanish Ministry of Education, Culture and Sport under Grant FPU13 /00542.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

On the stability of advanced power electronic converters: the Generalized Bode Criterion

  • Lumbreras Magallón, David
  • Barrios Rípodas, Ernesto
  • Urtasun Erburu, Andoni
  • Ursúa Rubio, Alfredo
  • Marroyo Palomo, Luis
  • Sanchis Gúrpide, Pablo
A key factor in the design of power electronic converters is the development of control systems and, in particular, the determination of their stability. Due to ease of application, the Bode criteria are currently the most commonly used stability criteria, both with regard to its classic version and to the subsequent revisions proposed in the literature. However, as these criteria have a limited range of applicability, on occasions it is necessary to resort to other universally applicable criteria such as the Nyquist criterion. Unlike Bode, the Nyquist criterion can always be applied, although its use considerably complicates the tuning of the controller. This paper proposes a new stability criterion, called Generalized Bode Criterion, which is based on the Nyquist criterion and, therefore, always applicable, but calculated from both the Bode diagram and the 0 Hz phase of the open-loop transfer function, thus making the criterion easy to be applied. This way, the proposed criterion combines the advantages of Nyquist and Bode criteria and provides an interesting and useful tool to help in the controller design process. The validation of the criterion is made on a voltage control loop for a stand-alone PV system through simulation and experimental tests made on a voltage control loop for a stand-alone PV system including a battery, a boost converter, an inverter and an ac load. The tests are also used to show the limitations of the classic Bode criterion and its revisions to correctly determine the stability of complex systems. IEEE, This work was supported in part by the Spanish State Research Agency (AEI) and FEDER-UE underGrant DPI2016-80641-R and Grant DPI2016-80642-R, in part by the Public University of Navarre through a doctoral scholarship, and in part by the Ingeteam Power Technology
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Parameter-independent battery control based on series and parallel impedance emulation

  • Urtasun Erburu, Andoni
  • Sanchis Gúrpide, Pablo
  • Guinjoan Gispert, Francesc
  • Marroyo Palomo, Luis
Appropriate voltage control is essential in order to extend the useful life of a battery. However, when universal chargers are used, the design of this control becomes more complicated, given the fact that the battery impedance value may vary considerably, depending not only on the operating point but also on the type, size, and aging level of the battery. This paper first shows how the voltage regulation can become extremely variable or even unstable when the controller is designed according to the proposals in the literature. We then go on to propose the emulation of a series and parallel impedance with the battery, which is easy to implement and achieves a control that is completely independent of the battery connected. The simulation results obtained for batteries with resistances ranging from 10 mΩ to 1Ω, show the problems with existing controls and confirm that the proposed control response is similar for all the possible range of battery resistance., This work was supported in part by the Spanish State Research Agency (AEI) and ERDF-UE under Grant DPI2016-80641-R, and in part by Ingeteam Power Technology.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Experimental assessment of cycling ageing of lithium-ion second-life batteries from electric vehicles

  • Braco Sola, Elisa
  • San Martín Biurrun, Idoia
  • Berrueta Irigoyen, Alberto
  • Sanchis Gúrpide, Pablo
  • Ursúa Rubio, Alfredo
The reutilization of batteries from electric vehicles allows to benefit from their remaining energy capacity and to increase their lifespan. The applications considered for the second life of these batteries are less demanding than electric vehicles regarding power and energy density. However, there is still some uncertainty regarding the technical and economic viability of these systems. In this context, the study of the ageing and lifetime of reused batteries is key to contribute to their development. This paper assesses the experimental cycle ageing of lithium-ion modules from different Nissan Leaf through accelerated cycling tests on their second life. The evolution of the internal parameters during ageing and the correlation between them are shown, including the analysis of best fitting curves. In addition, a second-life end-of-life criterion is proposed, based on capacity and internal resistance measurements during cells ageing, which can be applied to real application in order to prevent safety issues. By estimating future values from degradation trends and checking latter measurements, the ageing knee is identified. Results show that the modules operate for at least 2033 equivalent full cycles before reaching their ageing knee. This would mean more than 5 years of operation in a real second-life application, such as a photovoltaic self-consumption installation with daily cycling. Moreover, it is shown that a traditional cell characterisation based on capacity and internal resistance measurements is not enough to predict the durability of a cell during its second life., The authors would like to acknowledge the support of the European Union under the H2020 project STARDUST (774094), the Spanish State Research Agency (AEI) and FEDER–UE under grants DPI2016–80641-R, DPI2016–80642-R, PID2019–111262RB-I00 and PID2019–110956RB-I00, of Government of Navarra through research project 0011–1411–2018–000029 GERA and of Public University of Navarre under project ReBMS PJUPNA1904.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Low complexity energy management strategy for grid profile smoothing of a residential grid-connected microgrid using generation and demand forecasting

  • Arcos Avilés, Diego
  • Pascual Miqueleiz, Julio María
  • Guinjoan Gispert, Francesc
  • Marroyo Palomo, Luis
  • Sanchis Gúrpide, Pablo
This paper presents the design of an energy management strategy based on a low complexity Fuzzy Logic Control (FLC) for grid power profile smoothing of a residential grid-connected microgrid including Renewable Energy Sources (RES) and battery Energy Storage System (ESS). The proposed energy management strategy uses generation and demand forecasting to anticipate the future behavior of the microgrid. Accordingly to the microgrid power forecast error and the Battery State-of-Charge (SOC) the proposed strategy performs the suitable control of the grid power. A simulation comparison with previous energy management strategies highlights the advantages of the proposed work minimizing fluctuations and power peaks in the power profile exchanged with the grid while keeping the energy stored in the battery between secure limits. Finally, the experimental validation in a real residential microgrid implemented at Public University of Navarre (UPNA, Spain) demonstrates the proper operation of the proposed strategy achieving a smooth grid power profile and a battery SOC center close to the 75% of the rated battery capacity., This work is part of the project 2016-PIC-044 from the Universidad de las Fuerzas Armadas ESPE. This work was partially supported by the Spanish State Research Agency (AEI) and FEDER-UE under grants: DPI2015-67292, DPI2013-41224-P, DPI2013-42853-R and DPI2016-80641-R.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Methodology for sizing stand-alone hybrid systems: a case study of a traffic control system

  • San Martín Biurrun, Idoia
  • Berrueta Irigoyen, Alberto
  • Sanchis Gúrpide, Pablo
  • Ursúa Rubio, Alfredo
This paper proposes a methodology for sizing stand-alone hybrid photovoltaic-wind power generation systems. This methodology makes it possible to optimise the overall performance of the stand-alone system components, based on the premise of guaranteeing the power supply throughout the useful life of the installation at a minimum cost. The sizing is performed in two stages. Firstly, the components of the wind and photovoltaic power generation subsystem are obtained and, secondly, the size of the storage subsystem is determined. For the storage subsystem sizing, account is taken of the variation in efficiency according to the operating point and also the deterioration of the subsystem due to aging and, therefore, the loss of available energy during the useful life of the installation. This methodology is applied to a stand-alone traffic control system located on a secondary road in the Autonomous Community of Valencia (Spain). This system comprises wind and photovoltaic power generation components, a lithium battery bank and various traffic management components. Finally, an analysis of the proposed sizing is made. Satisfactory results are obtained, showing how the proposed methodology makes it possible to optimise the sizing of stand-alone systems with regard to the size of its components, cost and operation., This work has been supported by the Spanish State Research Agency (AEI) and FEDER-UE under grant DPI2013-42853-R, DPI2016-80642-R and DPI2016-80641-R; and by the Government of Navarre under project PIO38 INTEGRA-RENOVABLES.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Sub-synchronous resonance damping control strategy for DFIG wind turbines

  • Samanes Pascual, Javier
  • Gubía Villabona, Eugenio
  • López Taberna, Jesús
  • Burgos, Rolando
Doubly-fed induction generator (DFIG) wind turbines connected to capacitive series-compensated transmission lines are prone to exhibit oscillatory behavior. The phenomena is called sub-synchronous resonances (SSRs), as these oscillations occur at frequencies below the fundamental component. This paper first develops a modeling methodology for DFIG wind turbines, based on impedance matrices, that is applied to model a real wind farm where SSRs were reported. The stability analysis performed shows how the interaction between the grid-side converter and the rotor-side converter contribute to the instability of DFIG wind energy conversion systems connected to series compensated grids. With this model, we propose a simple sub-synchronous resonance control strategy based on an orthogonal proportional action applied to the rotor currents, and a variable gain in the PI controller adjusted as a function of the DFIG rotational speed. This control strategy depends only on the rotor currents, which are local and already measured variables in any DFIG wind turbine, and is implemented in the rotor side converter, so it does not imply an additional cost at wind farm or wind turbine level and can be applied to any DFIG wind energy conversion system (WECS). Additionally, it proves to be robust for any line impedance series compensation level, and it does not need real-time information concerning the grid at which the wind turbine is connected, or its parameters. A real case study is considered, where the sub-synchronous resonance damping strategy presented in this work is able to stabilize the system for every possible line impedance compensation level., This work was supported by the Agencia Estatal de Investigacion (AEI) (Spanish State Research Agency) under Grant PID2019-110956RB-I00/AEI/10.13039 and Grant DPI-2016-80641-R.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Parameter-independent control for battery chargers based on virtual impedance emulation

  • Urtasun Erburu, Andoni
  • Berrueta Irigoyen, Alberto
  • Sanchis Gúrpide, Pablo
  • Marroyo Palomo, Luis
An effective battery voltage regulation is fundamental to extend battery lifetime and to avoid overvoltage. However, the design of this regulation is complicated due to the wide battery impedance range, which, when dealing with universal chargers, is dependent not only on the operating point but also on the battery type and size. This paper first shows how the voltage response becomes highly variable when designing the controller as described in the literature. Then, it proposes to emulate virtual impedance in parallel with the battery, making it possible to achieve a voltage control which is independent of battery characteristics. Experimental results are carried out for a new lithium-ion battery with 25 mΩ-impedance and an overused lead-acid battery with 400 mΩ-impedance. For this large impedance variation, the results evidence the problems of the conventional control and validate the superior performance of the proposed control., This work was supported in part by the Spanish State Research Agency (AEI) and FEDER-UE under Grant DPI2016-80641-R and in part by Ingeteam Power Technology.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Control design and stability analysis of power converters: the MIMO generalized bode criterion

  • Samanes Pascual, Javier
  • Urtasun Erburu, Andoni
  • Barrios Rípodas, Ernesto
  • Lumbreras Magallón, David
  • López Taberna, Jesús
  • Gubía Villabona, Eugenio
  • Sanchis Gúrpide, Pablo
Three-phase dynamic systems and multiphase generators are frequently modeled and controlled in the synchronous reference frame. To properly model the cross-coupling terms in this reference frame, complex vector theory and transfer function matrices are commonly applied, obtaining multiple-input multiple-output (MIMO) dynamic models. The stability of MIMO systems can be assessed through the Nyquist generalized stability criterion. However, the use of the Nyquist diagram complicates the controller design. The Bode diagram is a more intuitive tool for the controller design; however, the Bode stability criterion is not applicable to MIMO systems. In this article, the MIMO generalized Bode criterion is proposed. Since this stability criterion is based on the Nyquist generalized stability criterion, it can be applied to any system. Furthermore, it is simple to use, as it only requires information contained in the open-loop transfer matrix and the Bode diagram. The proposed stability criterion thus offers an interesting tool for the controller design procedure in MIMO systems, as it is shown in this article for two common applications: the current control loop of a power converter, a 2 × 2 system, and the current control loop of two independent power converters in parallel, a 4 × 4 system., This work has been supported by the Spanish State Research Agency (AEI) and FEDER-UE under grant DPI2016-80641-R.