INTEGRACION DE BIOSENSORES, MATRICES DE MICROELECTRODOS 3D Y CIRCUITOS FOTONICOS CON TECNOLOGIA COMPATIBLE CMOS

PID2021-127653NB-C21

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprogram Subprograma Estatal de Generación de Conocimiento
Call Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Call year 2021
State Plan 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 11
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Electrochemical biosensor for aerobic acetate detection

  • Forner, E.
  • Ezenarro, J.J.
  • Pérez-Montero, M.
  • Vigués, N.
  • Asensio-Grau, Andrea
  • Mas, J.
  • Baeza, M.
  • Muñoz-Berbel, X.
  • Villa, R.
  • Gabriel, G.
  • Andrés Grau, Ana María|||0000-0002-6132-3167
[EN] There is an increasing demand on alternatives methods to animal testing. Numerous health parameters have been already studied using in vitro devices able to mimic the essential functions of the organs, being the real-time monitoring and response to stimuli their main limitations. Regarding the health of the gut, the short chain fatty acids, and particularly acetate, have emerged as key biomarkers to evaluate gut healthiness and disease development, although the number of acetate biosensors is still very low. This article presents a microbial biosensor based on fully biocompatible materials which is able to detect acetate in aerobic conditions in the range between 11 and 50 mM, and without compromising the viability and function of either bacteria (>90% viability) or mammalian cells (>80% viability). The detection mechanism is based on the metabolism of acetate by Escherichia coli bacteria immobilized on the transducer surface. Ferricyanide is used as a redox mediator to transfer electrons from the acetate metabolism in the bacterial cells to the transducer. High bacterial concentrations are immobilized in the transducer surface (109 cfu mL-1) by electrodeposition of conductive alginate hydrogels doped with reduced graphene oxide. The results show successful outcomes to exploit bacteria as a biosensing tool, based on the use of inkjet printed transducers, biocompatible materials and cell entrapment technologies., The authors acknowledge the support from the Ministerio de Ciencia Innovacion y Universidades (MICIU/FEDER, EU) , in Spain, through GUMICHIP (RTI2018-096786-B-I00) , GALILEI (PID2021-126253OB-C21) and CHIP4CELL projects (PID2021-127653NB-C21) and the support of the Generalitat de Catalunya to 2021SGR00495. The work has been performed by the ICTS "NANBIOSIS", more specifically by the U8 Unit of the CIBER in Bioengineering, Biomaterials & Nanomedicine (CIBER-BBN) at the IMB-CNM (CSIC) . This work also made use of theSpanish ICTS Network MICRONANOFABS partially supported by MEINCOM. We would like to thank the members of the GENOCOV research group from Universitat Autonoma, specifically Dr. D. Gabriel and PhD student M. Fachal, for their assistance in the liquid chroma-tography analysis presented in this work.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Fiber-Optic-Based System for High-Resolution Monitoring of Stretch in Excised Tissues

  • Velarte, Antonio
  • Otin, Aranzazu
  • Giménez-Gómez, Pablo
  • Muñoz-Berbel, Xavier
  • Pueyo, Esther
Cardiovascular diseases cause a high number of deaths nowadays. To improve these statistics, new strategies to better understand the electrical and mechanical abnormalities underlying them are urgently required. This study focuses on the development of a sensor to measure tissue stretch in excised tissues, enabling improved knowledge of biomechanical properties and allowing greater control in real time. A system made of biocompatible materials is described, which is based on two cantilevered platforms that integrate an optical fiber inside them to quantify the amount of stretch the tissues are exposed to with a precision of μ m. The operating principle of the sensor is based on the variation of the optical path with the movement of the platforms onto which the samples are fixed. The conducted tests highlight that this system, based on a simple topology and technology, is capable of achieving the desired purpose (a resolution of ∼1 μ m), enabling the tissue to be bathed in any medium within the system., This work was funded by projects PID2019-105674RB-I00, RTI2018-100773-B-C31, PID2021-127653NB-C21, PID2022-140556OB-I00 and TED2021-130459B-I00 by Ministerio de Ciencia e Innovación, ERC grant 638284 by European Research Council and projects LMP94_21 and BSICoS T39_23R by European Social Fund (EU) and Aragón Government., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

A novel integrated platform enabling simultaneous microextraction and chemical analysis on-chip

  • Santigosa-Murillo, Elia
  • Moreno, Alexandre
  • Ramos-Payán, María
  • Ríos, Juan Manuel
  • Muñoz-Berbel, Xavier
  • Muñoz, María
  • Giménez-Gómez, Pablo
The nature and size of biological, pharmaceutical or environmental analytes complicates their extraction and detection outside of laboratories and near the site of interest by the current chromatographic methods because they require the combination of bulky extraction and detection methods. In order to solve this inefficient centralized control, a ground-breaking and miniaturized proof of concept platform is developed in this work. The platform integrates for the very first time an electro-membrane extraction process and an accurate analyte quantification method in the same device, by using electrochemical impedance spectroscopy (EIS) as analytical technique. The microfluidic flow cell, including the microfluidic components, is fabricated in polymeric materials by rapid prototyping techniques. It comprises a four-electrode platinum thin-film chip that enables the control of the microextraction and the full characterization of the process, i.e., extraction efficiency determination, at the same time. The microfluidic system has been simulated by using computational tools, enabling an accurate prediction of the effect of the different experimental conditions in the microextraction efficiency. The platform has been validated in the microextraction of the nonsteroidal anti-inflammatory drug ketoprofen in a range from 0.5 ppm to 6 ppm. The predicted microextraction efficiency values obtained by EIS were compared with those calculated from the high-performance liquid chromatography coupled with a diode array detector (HPLC-DAD), showing an excellent agreement. This validates the high potential of this integrated and miniaturized platform for the simultaneous extraction by electro-membrane and also the analysis within the platform, solving one of the of most important limitations of current systems., This work was financially supported by the Ministry of Science, Innovation and Universities - State Research Agency -AEI- and European Regional Development Fund -ERDF- (RTI2018-101974-B-C-21 and PID2021-127653NB-C21). E. Santigosa thanks Universitat Autònoma de Barcelona (UAB) for her PIF fellowship supported by the Agencia de Gestió d’Ajusts Universitaris i de Recerca (2017-SGR-329). A. Moreno is grateful to MICINN for the grant of a PhD studentship from the FPI program (PRE2019-088338)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Electrochemical biosensor for aerobic acetate detection

  • Forner, E
  • Ezenarro, J J
  • Pérez-Montero, M
  • Vigués, N
  • Asensio-Grau, A
  • Borges, Andrés A.
  • Mas, J
  • Baeza, M
  • Muñoz-Berbel, Xavier
  • Villa, Rosa
  • Gabriel, Gemma
There is an increasing demand on alternatives methods to animal testing. Numerous health parameters have been already studied using in vitro devices able to mimic the essential functions of the organs, being the real-time monitoring and response to stimuli their main limitations. Regarding the health of the gut, the short chain fatty acids, and particularly acetate, have emerged as key biomarkers to evaluate gut healthiness and disease development, although the number of acetate biosensors is still very low. This article presents a microbial biosensor based on fully biocompatible materials which is able to detect acetate in aerobic conditions in the range between 11 and 50 mM, and without compromising the viability and function of either bacteria (>90% viability) or mammalian cells (>80% viability). The detection mechanism is based on the metabolism of acetate by Escherichia coli bacteria immobilized on the transducer surface. Ferricyanide is used as a redox mediator to transfer electrons from the acetate metabolism in the bacterial cells to the transducer. High bacterial concentrations are immobilized in the transducer surface (109 cfu mL-1) by electrodeposition of conductive alginate hydrogels doped with reduced graphene oxide. The results show successful outcomes to exploit bacteria as a biosensing tool, based on the use of inkjet printed transducers, biocompatible materials and cell entrapment technologies., The authors acknowledge the support from the Ministerio de Ciencia Innovacion y Universidades (MICIU/FEDER, EU), in Spain, through GUMICHIP (RTI2018-096786-B-I00), GALILEI (PID2021-126253OB-C21) and CHIP4CELL projects (PID2021-127653NB-C21) and the support of the Generalitat de Catalunya to 2021SGR00495. The work has been performed by the ICTS “NANBIOSIS”, more specifically by the U8 Unit of the CIBER in Bioengineering, Biomaterials & Nanomedicine (CIBER-BBN) at the IMB-CNM (CSIC). This work also made use of the Spanish ICTS Network MICRONANOFABS partially supported by MEINCOM. We would like to thank the members of the GENOCOV research group from Universitat Autonoma, specifically Dr. D. Gabriel and PhD student M. Fachal, for their assistance in the liquid chromatography analysis presented in this work., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Optical Detection Techniques for Biomedical Sensing: A Review of Printed Circuit Board (PCB)-Based Lab-on-Chip Systems

  • Perdigones, Francisco
  • Giménez-Gómez, Pablo
  • Muñoz-Berbel, Xavier
  • Aracil, Carmen
Lab on Printed Circuit Boards (Lab-on-PCB) technology has emerged as a promising platform, offering miniaturization, integration, and cost-effective fabrication for a wide range of sensing applications. This review explores the most common optical detection techniques implemented on printed circuit boards (PCBs), including absorbance, fluorescence, and chemiluminescence, discussing their working principles, advantages, and limitations in the context of PCB-based sensing. Additionally, evanescent wave generation is considered as an alternative optical approach with benefits for specific applications. Elements such as excitation sources, photodetectors, and the distinguishing characteristics of each method are analyzed to provide a comprehensive, but concise, overview of the field. Emphasis is placed on how the PCB platform influences the performance, sensitivity, and feasibility of these detection methods, highlighting relevant design considerations. This work aims to provide a solid foundation for researchers interested in optical sensing within this technology, serving as a reference for future developments and applications in PCB-based optical detection., This research received no external funding. We are gratefyul for our collaboration with the project “Interacción electro-neuronal inteligente en un sistema de cultivo de larga duración” (reference number PID2021-127653NB-C22), and the project “Integración de biosensores, matrices de microelectrodos 3D y circuitos fotónicos con tecnología compatible CMOS” (reference project number PID2021-127653NB-C21; Ministerio de Ciencia e Innovación, Plan Estatal 2021–2023—Proyectos Investigación No Orientada)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Reusable Colorimetric Biosensors on Sustainable Silk-Based Platforms

  • Márquez, Augusto
  • Santiago, Sara
  • Dos Santos, Molíria Vieira
  • Aznar-Cervantes, Salvador D
  • Domínguez, Carlos
  • Omenetto, Fiorenzo G
  • Guirado, Gonzalo
  • Muñoz-Berbel, Xavier
In biosensor development, silk fibroin is advantageous for providing transparent, flexible, chemically/mechanically stable, biocompatible, and sustainable substrates, where the biorecognition element remains functional for long time periods. These properties are employed here in the production of point-of-care biosensors for resource-limited regions, which are able to display glucose levels without the need for external instrumentation. These biosensors are produced by photopatterning silk films doped with the enzymes glucose oxidase and peroxidase and photoelectrochromic molecules from the dithienylethene family acting as colorimetric mediators of the enzymatic reaction. The photopatterning results from the photoisomerization of dithienylethene molecules in the silk film from its initial uncolored opened form to its pink closed one. The photoisomerization is dose-dependent, and colored patterns with increasing color intensities are obtained by increasing either the irradiation time or the light intensity. In the presence of glucose, the enzymatic cascade reaction is activated, and peroxidase selectively returns closed dithienylethene molecules to their initial uncolored state. Color disappearance in the silk film is proportional to glucose concentration and used to distinguish between hypoglycemic (below 4 mM), normoglycemic (4-6 mM), and hyperglycemic levels (above 6 mM) by visual inspection. After the measurement, the biosensor can be regenerated by irradiation with UV light, enabling up to five measurement cycles. The coupling of peroxidase activity to other oxidoreductases opens the possibility to produce long-life reusable smart biosensors for other analytes such as lactate, cholesterol, or ethanol., This work was supported by the Spanish R&D National Program (MEC Project TEC2014-54449-C3-1-R, RTI2018-100773-B-C31 and PID2021-127653NB-C21). Moliria Vieira dos Santos thanks FAPESP for a postdoctoral fellowship, grants #2016/11591-8 and #2018/11039-9. A.M. is also grateful to the MICINN for the award of a research studentship from the FPI program (BES-2015-072946). The authors also thank the Ministerio de Ciencia e Innovación of Spain for financial support through projects PID2019-106171RB-I00, PID2022-1412930B-I00, and AGAUR (Generalitat de Catalunya, 2021 SGR 00052). Dr. Salvador Aznar acknowledges partial financial support (60%) from the European Commission ERDF/FEDER Operational Programme of Murcia (2021-2027), Project No. 50463 “Development of sustainable models of agricultural, livestock, and aquaculture production” (subproject: Innovation in the field of sericulture: New materials, biomaterials, and extracts of biomedical interest)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Silk Fibroin Functionalised Isfets with Enhanced Stability for Long-Term Ph Monitoring of Cell Cultures

  • Moreno Diaz, Alexander
  • Urbano-Gámez, Jesus
  • Pérez-Montero, Marta
  • Rodríguez-Rodríguez, Rosalia
  • Aznar-Cervantes, Salvador
  • Perdigones, Francisco
  • Manuel Quero, José
  • Domínguez Horna, Carlos
  • Jiménez-Jorquera, Cecilia
  • Muñoz Berbel, Xavier
Silk-fibroin is a biomaterial with high thermal and chemical stability, mechanical strength, biocompatibility, wettability and filtration capacity. These properties are here exploited in the development of miniaturised long-life pH sensors implemented in microfluidic chambers for long-term cell culture monitoring. Silk fibroin is crystallised on the gate of silicon nitride ion- selective-field-effect-transistors (ISFETs), producing silk films of 30±14 μm. The silk-modified ISFETs exhibit similar responses to pH than bare ISFETs in terms of sensitivity (51±2 mV/pH vs. 51±4 mV/pH) and precision (both >99% vs. glass-membrane pH meters). Main advantages of silk modification reside on the sensor drift and biofouling. Hence, silk ISFETs present smaller signal variations associated to drift and to molecular adsorption, the latter reduced 10 times thanks to the filtering capacity of the film. After implementation in cell culture chambers, silk-modified ISFETs are able to continuously monitor the culture pH for more than 3 days without the need for recalibration steps. Due to their simplicity of operation, durability, excellent analytical performance and small size, these sensors may be a first choice in applications where precise pH determination is required in small sample volumes, e.g. cell culture analysis, clinical diagnostics or sweat monitoring., This work was funded by the Spanish Ministry of Science and Innovation, MICINN− State Research Agency −AEI− (PID2021-127653NB-C21), the MICINN FPI program (PRE2019−088338) and European Commission ERDF/FEDER Operational Programme of Murcia (2021-2027); Project No. 50463. Project name: Integración de biosensores, matrices de microelectrodos 3D y circuitos fotónicos con tecnología compatible CMOS Project number: PID2021-127653NB-C1, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Silkworm gut fibre-based biosensors for optical glucose detection

  • Fitó-Parera, Aina
  • Márquez, Augusto
  • Rodríguez-Núñez, Pablo
  • Aznar-Cervantes, Salvador D.
  • Reguera, Ana Cristina
  • Perdigones, Francisco
  • Aracil, Carmen
  • Rodríguez-Rodríguez, Rosalía
  • Domínguez, Carlos
  • Muñoz-Berbel, Xavier
Silk is a re-emerging biomaterial with significant potential for optical waveguiding due to its high transparency in the visible spectrum and elevated refractive index. Naturally occurring silk filamentous structures, such as silkworm gut fibres (SGFs), resemble traditional optical fibres while offering advantages such as biocompatibility, flexibility, mechanical strength and biodegradability. In this study, SGFs from different Bombyx mori races were evaluated for their suitability in optical fibre-based biosensing applications. White SGFs were selected for their superior optical properties, including a broad transmission window in the visible spectrum, strong light confinement, and high guidance efficiency. However, pristine SGFs exhibited sensitivity to hydration/drying cycles, leading to transmission losses. To address this, an alginate cladding was applied, stabilizing the fibre while preserving biocompatibility and optical performance. The modified SGFs successfully quantified colorants in the surrounding medium and were further employed in biochemical sensing. Specifically, alginate-coated SGFs enabled glucose detection by monitoring the colorimetric response of a redox mediator oxidized through a bi-enzymatic reaction involving glucose oxidase and peroxidase. This system effectively distinguished glucose concentrations corresponding to healthy, hypoglycaemic, and hyperglycaemic (pre-diabetic and diabetic) conditions. Furthermore, direct glucose measurements in real blood samples were possible, as the alginate layer functioned as a size-exclusion filter, selectively retaining cellular components while allowing glucose to diffuse and react with immobilized enzymes and redox mediators. The use of silk and alginate, both recognised as biodegradable materials, suggests significant potential for the development of real-time, minimally invasive glucose monitoring systems for in vitro and in vivo analysis., This work was financially supported by the MICINN\u2212 State Research Agency \u2212AEI\u2212 ( PID2021-127653NB-C21 ). Dr. Salvador Aznar acknowledges partial financial support from the European Commission ERDF/FEDER Operational Programme of Murcia (2021-2027) , Project No. 50463 \"Development of sustainable models of agricultural, livestock and aquaculture production\" (Subproject: Innovation in the field of sericulture: New materials, biomaterials and extracts of biomedical interest)., Peer reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Fiber-Optic-Based System for High-Resolution Monitoring of Stretch in Excised Tissues

  • Velarte, Antonio
  • Otin, Aranzazu
  • Giménez-Gómez, Pablo
  • Muñoz-Berbel, Xavier
  • Pueyo, Esther
Cardiovascular diseases cause a high number of deaths nowadays. To improve these statistics, new strategies to better understand the electrical and mechanical abnormalities underlying them are urgently required. This study focuses on the development of a sensor to measure tissue stretch in excised tissues, enabling improved knowledge of biomechanical properties and allowing greater control in real time. A system made of biocompatible materials is described, which is based on two cantilevered platforms that integrate an optical fiber inside them to quantify the amount of stretch the tissues are exposed to with a precision of μm. The operating principle of the sensor is based on the variation of the optical path with the movement of the platforms onto which the samples are fixed. The conducted tests highlight that this system, based on a simple topology and technology, is capable of achieving the desired purpose (a resolution of ∼1 μm), enabling the tissue to be bathed in any medium within the system.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

A novel integrated platform enabling simultaneous microextraction and chemical analysis on-chip

  • Santigosa-Murillo, Elia
  • Moreno, Alexandre
  • Ramos-Payán, María
  • Rios Gallardo, Juan Manuel
  • Muñoz-Berbel, Xavier|||0000-0002-6447-5756
  • Muñoz, Maria|||0000-0001-5540-1491
  • Giménez-Gómez, Pablo|||0000-0003-3443-802X
The nature and size of biological, pharmaceutical or environmental analytes complicates their extraction and detection outside of laboratories and near the site of interest by the current chromatographic methods because they require the combination of bulky extraction and detection methods. In order to solve this inefficient centralized control, a ground-breaking and miniaturized proof of concept platform is developed in this work. The platform integrates for the very first time an electro-membrane extraction process and an accurate analyte quantification method in the same device, by using electrochemical impedance spectroscopy (EIS) as analytical technique. The microfluidic flow cell, including the microfluidic components, is fabricated in polymeric materials by rapid prototyping techniques. It comprises a four-electrode platinum thin-film chip that enables the control of the microextraction and the full characterization of the process, i.e., extraction efficiency determination, at the same time. The microfluidic system has been simulated by using computational tools, enabling an accurate prediction of the effect of the different experimental conditions in the microextraction efficiency. The platform has been validated in the microextraction of the nonsteroidal anti-inflammatory drug ketoprofen in a range from 0.5 ppm to 6 ppm. The predicted microextraction efficiency values obtained by EIS were compared with those calculated from the high-performance liquid chromatography coupled with a diode array detector (HPLC-DAD), showing an excellent agreement. This validates the high potential of this integrated and miniaturized platform for the simultaneous extraction by electro-membrane and also the analysis within the platform, solving one of the of most important limitations of current systems.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Reusable Colorimetric Biosensors on Sustainable Silk-Based Platforms

  • Márquez, Augusto|||0000-0003-3074-7941
  • Santiago Malagon, Sara|||0000-0002-1206-1455
  • Santos, Molíria V.|||0000-0003-0569-2424
  • Aznar-Cervantes, Salvador|||0000-0001-9809-7215
  • Dominguez, Carlos|||0000-0002-5972-7285
  • Omenetto, Fiorenzo|||0000-0002-0327-853X
  • Guirado, Gonzalo|||0000-0003-2128-7007
  • Muñoz-Berbel, Xavier|||0000-0002-6447-5756
In biosensor development, silk fibroin is advantageous for providing transparent, flexible, chemically/mechanically stable, biocompatible, and sustainable substrates, where the biorecognition element remains functional for long time periods. These properties are employed here in the production of point-of-care biosensors for resource-limited regions, which are able to display glucose levels without the need for external instrumentation. These biosensors are produced by photopatterning silk films doped with the enzymes glucose oxidase and peroxidase and photoelectrochromic molecules from the dithienylethene family acting as colorimetric mediators of the enzymatic reaction. The photopatterning results from the photoisomerization of dithienylethene molecules in the silk film from its initial uncolored opened form to its pink closed one. The photoisomerization is dose-dependent, and colored patterns with increasing color intensities are obtained by increasing either the irradiation time or the light intensity. In the presence of glucose, the enzymatic cascade reaction is activated, and peroxidase selectively returns closed dithienylethene molecules to their initial uncolored state. Color disappearance in the silk film is proportional to glucose concentration and used to distinguish between hypoglycemic (below 4 mM), normoglycemic (4-6 mM), and hyperglycemic levels (above 6 mM) by visual inspection. After the measurement, the biosensor can be regenerated by irradiation with UV light, enabling up to five measurement cycles. The coupling of peroxidase activity to other oxidoreductases opens the possibility to produce long-life reusable smart biosensors for other analytes such as lactate, cholesterol, or ethanol.