Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Interfacial Phenomena Governing Performance of Graphene Electrodes in Aqueous Electrolyte

  • Delgà-Fernández, Marta|||0000-0001-7434-8593
  • Toral-Lopez, Alejandro|||0000-0001-5612-0536
  • Guimerà Brunet, Anton|||0000-0003-1768-3293
  • Pérez-Marín, Antonio Pablo|||0000-0003-1843-8273
  • Marin, Enrique G|||0000-0002-0302-3764
  • Godoy Medina, Andres|||0000-0002-3014-8765
  • Garrido, Jose|||0000-0001-5621-1067
  • Del Corro, Elena|||0000-0001-6452-9139
There is evidence of the presence of intercalated water between graphene and the substrate in electronic devices. However, a proper understanding of the impact of this phenomenon, which causes important limitations for the optimization of graphene-based devices operating in aqueous electrolytes, is missing. We used graphene-based electrodes on insulating and conducting substrates to evaluate the impact of intercalated water by combining experimental techniques with numerical simulations. Results show that the capacitance of the conductive substrate/graphene electrodes is significantly higher than that of the insulating substrate/graphene ones. Meanwhile, Raman spectroscopy demonstrates that graphene charge modulation with the applied potential is independent of the substrate conductivity. We found that this intriguing behavior is influenced by the water intercalation phenomena and governed by the substrate conductive nature. This work contributes to the understanding of the electric response of graphene-based devices in an aqueous environment and of the methods to measure and model it.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Concurrent functional ultrasound imaging with graphene-based DC-coupled electrophysiology as a platform to study slow brain signals and cerebral blood flow under control and pathophysiological brain states

  • Zhang, Julie Meng|||0000-0001-5985-3815
  • Masvidal Codina, Eduard|||0000-0002-9579-8603
  • Nguyen, Diep
  • Illa, Xavi|||0000-0002-3212-1128
  • Dégardin, Julie
  • Goulet, Ruben
  • Prats-Alfonso, Elisabet
  • Matsoukis, Stratis
  • Guger, Christoph
  • Garrido, Jose Antonio
  • Picaud, Serge|||0000-0002-0548-5145
  • Guimerà-Brunet, Anton
  • Wykes, Robert C|||0000-0002-6141-6822
Current methodology used to investigate how shifts in brain states associated with regional cerebral blood volume (CBV) change in deep brain areas, are limited by either the spatiotemporal resolution of the CBV techniques, and/or compatibility with electrophysiological recordings; particularly in relation to spontaneous brain activity and the study of individual events. Additionally, infraslow brain signals (<0.1 Hz), including spreading depolarisations, DC-shifts and infraslow oscillations (ISO), are poorly captured by traditional AC-coupled electrographic recordings; yet these very slow brain signals can profoundly change CBV. To gain an improved understanding of how infraslow brain signals couple to CBV we present a new method for concurrent CBV with wide bandwidth electrophysiological mapping using simultaneous functional ultrasound imaging (fUS) and graphene-based field effect transistor (gFET) DC-coupled electrophysiological acquisitions. To validate the feasibility of this methodology visually-evoked neurovascular coupling (NVC) responses were examined. gFET recordings are not affected by concurrent fUS imaging, and epidural placement of gFET arrays within the imaging window did not deteriorate fUS signal quality. To examine directly the impact of infra-slow potential shifts on CBV, cortical spreading depolarisations (CSDs) were induced. A biphasic pattern of decreased, followed by increased CBV, propagating throughout the ipsilateral cortex, and a delayed decrease in deeper subcortical brain regions was observed. In a model of acute seizures, CBV oscillations were observed prior to seizure initiation. Individual seizures occurred on the rising phase of both infraslow brain signal and CBV oscillations. When seizures co-occurred with CSDs, CBV responses were larger in amplitude, with delayed CBV decreases in subcortical structures. Overall, our data demonstrate that gFETs are highly compatible with fUS and allow concurrent examination of wide bandwidth electrophysiology and CBV. This graphene-enabled technological advance has the potential to improve our understanding of how infraslow brain signals relate to CBV changes in control and pathological brain states.
Dipòsit Digital de Documents de la UAB
Publication Artículo de revisión (ReviewArticle)

Cortical spreading depolarizations in stroke, Mechanisms, neuroprotective interventions, and monitoring techniques

  • Díaz Pérez, Andrea|||0009-0008-2215-6344
  • Alvarez de Eulate, Nerea|||0009-0009-9031-3388
  • Masvidal Codina, Eduard|||0000-0002-9579-8603
  • Illa, Xavi|||0000-0002-3212-1128
  • Navarro, X. (Xavier)|||0000-0001-9849-902X
  • Guimerà Brunet, Anton|||0000-0003-1768-3293
  • Jiménez Altayó, Francesc|||0000-0002-9034-2041
  • Penas Pérez, Clara|||0000-0003-0554-3832
Cortical spreading depolarization (CSD) is a pathophysiological event critically implicated in ischemic stroke and other brain disorders. It consists of slowly propagating waves of massive neuronal and glial depolarization in cerebral gray matter, accompanied by spreading depression of cortical activity. CSD disrupts ion homeostasis, alters cerebral blood flow, and contributes to neuronal death in vulnerable tissue. This comprehensive review summarizes both classic and recent studies on CSD mechanisms and their role in brain damage progression after stroke. We also review potential neuroprotective strategies to mitigate CSD-induced damage and discuss available technologies for detecting CSD. Advancing our understanding of CSD mechanisms, combined with targeted neuroprotective strategies and improved monitoring techniques, holds promise for reducing stroke-related brain injury and guiding personalized recovery approaches.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Electrochemical biosensor for aerobic acetate detection

  • Forner, E.
  • Ezenarro, J.J.
  • Pérez-Montero, M.
  • Vigués, N.
  • Asensio-Grau, Andrea
  • Mas, J.
  • Baeza, M.
  • Muñoz-Berbel, X.
  • Villa, R.
  • Gabriel, G.
  • Andrés Grau, Ana María|||0000-0002-6132-3167
[EN] There is an increasing demand on alternatives methods to animal testing. Numerous health parameters have been already studied using in vitro devices able to mimic the essential functions of the organs, being the real-time monitoring and response to stimuli their main limitations. Regarding the health of the gut, the short chain fatty acids, and particularly acetate, have emerged as key biomarkers to evaluate gut healthiness and disease development, although the number of acetate biosensors is still very low. This article presents a microbial biosensor based on fully biocompatible materials which is able to detect acetate in aerobic conditions in the range between 11 and 50 mM, and without compromising the viability and function of either bacteria (>90% viability) or mammalian cells (>80% viability). The detection mechanism is based on the metabolism of acetate by Escherichia coli bacteria immobilized on the transducer surface. Ferricyanide is used as a redox mediator to transfer electrons from the acetate metabolism in the bacterial cells to the transducer. High bacterial concentrations are immobilized in the transducer surface (109 cfu mL-1) by electrodeposition of conductive alginate hydrogels doped with reduced graphene oxide. The results show successful outcomes to exploit bacteria as a biosensing tool, based on the use of inkjet printed transducers, biocompatible materials and cell entrapment technologies., The authors acknowledge the support from the Ministerio de Ciencia Innovacion y Universidades (MICIU/FEDER, EU) , in Spain, through GUMICHIP (RTI2018-096786-B-I00) , GALILEI (PID2021-126253OB-C21) and CHIP4CELL projects (PID2021-127653NB-C21) and the support of the Generalitat de Catalunya to 2021SGR00495. The work has been performed by the ICTS "NANBIOSIS", more specifically by the U8 Unit of the CIBER in Bioengineering, Biomaterials & Nanomedicine (CIBER-BBN) at the IMB-CNM (CSIC) . This work also made use of theSpanish ICTS Network MICRONANOFABS partially supported by MEINCOM. We would like to thank the members of the GENOCOV research group from Universitat Autonoma, specifically Dr. D. Gabriel and PhD student M. Fachal, for their assistance in the liquid chroma-tography analysis presented in this work.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Nanoporous graphene-based thin-film microelectrodes for in vivo high-resolution neural recording and stimulation

  • Viana, Damia|||0000-0001-8558-986X
  • Walston, Steven T.|||0000-0003-4567-8926
  • Masvidal Codina, Eduard|||0000-0002-9579-8603
  • Illa, Xavi|||0000-0002-3212-1128
  • Rodríguez-Meana, Bruno|||0000-0003-0052-7446
  • Del Valle, Jaume|||0000-0002-6703-8244
  • Hayward, Andrew
  • Dodd, Abbie
  • Loret, Thomas|||0000-0001-9171-9819
  • Prats-Alfonso, Elisabet
  • de la Oliva, Natalia|||0000-0002-1263-2705
  • Palma, Marie
  • Del Corro, Elena|||0000-0001-6452-9139
  • del Pilar Bernicola, María
  • Rodríguez-Lucas, Elisa
  • Gener, Thomas|||0000-0001-9209-9228
  • de la Cruz, Jose Manuel
  • Torres-Miranda, Miguel
  • Duvan, Fikret Taygun|||0000-0002-3377-9351
  • Ria, Nicola|||0000-0002-0082-0952
  • Sperling, Justin R.|||0000-0002-1708-2474
  • Martí-Sánchez, Sara|||0000-0003-4283-1489
  • Spadaro, Maria Chiara|||0000-0002-6540-0377
  • Hébert, Clément|||0000-0001-9667-033X
  • Savage, Sinead|||0000-0002-1761-9390
  • Arbiol i Cobos, Jordi|||0000-0002-0695-1726
  • Guimerà Brunet, Anton|||0000-0003-1768-3293
  • Puig, Maria Victoria|||0000-0002-1490-4153
  • Yvert, Blaise|||0000-0002-8850-7935
  • Navarro, X. (Xavier)|||0000-0001-9849-902X
  • Kostarelos, Kostas|||0000-0002-2224-6672
  • Garrido, Jose|||0000-0001-5621-1067
One of the critical factors determining the performance of neural interfaces is the electrode material used to establish electrical communication with the neural tissue, which needs to meet strict electrical, electrochemical, mechanical, biological and microfabrication compatibility requirements. This work presents a nanoporous graphene-based thin-film technology and its engineering to form flexible neural interfaces. The developed technology allows the fabrication of small microelectrodes (25 µm diameter) while achieving low impedance (∼25 kΩ) and high charge injection (3-5 mC cm ). In vivo brain recording performance assessed in rodents reveals high-fidelity recordings (signal-to-noise ratio >10 dB for local field potentials), while stimulation performance assessed with an intrafascicular implant demonstrates low current thresholds (<100 µA) and high selectivity (>0.8) for activating subsets of axons within the rat sciatic nerve innervating tibialis anterior and plantar interosseous muscles. Furthermore, the tissue biocompatibility of the devices was validated by chronic epicortical (12 week) and intraneural (8 week) implantation. This work describes a graphene-based thin-film microelectrode technology and demonstrates its potential for high-precision and high-resolution neural interfacing.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Single-Step Functionalization Strategy of Graphene Microtransistor Array with Chemically Modified Aptamers for Biosensing Applications

  • Brosel-Oliu, Sergi
  • Rius, Gemma|||0000-0003-0552-1043
  • Aviñó, Ana|||0000-0003-3047-738X
  • Nakatsuka, Nako
  • Illa, Xavi|||0000-0002-3212-1128
  • Del Corro, Elena|||0000-0001-6452-9139
  • Delgà-Fernández, Marta|||0000-0001-7434-8593
  • Masvidal Codina, Eduard|||0000-0002-9579-8603
  • Rodríguez, Natalia
  • Merino, Juan Pedro
  • Criado, Alejandro|||0000-0002-9732-513X
  • Prato, Maurizio|||0000-0002-8869-8612
  • Tkatchenko, Raphaela
  • Eritja, Ramon|||0000-0001-5383-9334
  • Godignon, Philippe
  • Garrido, Jose|||0000-0001-5621-1067
  • Villa, Rosa|||0000-0003-2735-3204
  • Guimerà, Anton
  • Prats-Alfonso, Elisabet
Graphene solution-gated field-effect transistors (gSGFETs) offer high potential for chemical and biochemical sensing applications. Among the current trends to improve this technology, the functionalization processes are gaining relevance for its crucial impact on biosensing performance. Previous efforts are focused on simplifying the attachment procedure from standard multi-step to single-step strategies, but they still suffer from overreaction, and impurity issues and are limited to a particular ligand. Herein, a novel strategy for single-step immobilization of chemically modified aptamers with fluorenylmethyl and acridine moieties, based on a straightforward synthetic route to overcome the aforementioned limitations is presented. This approach is benchmarked versus a standard multi-step strategy using thrombin as detection model. In order to assess the reliability of the functionalization strategies 48-gSGFETs arrays are employed to acquire large datasets with multiple replicas. Graphene surface characterization demonstrates robust and higher efficiency in the chemical coupling of the aptamers with the single-step strategy, while the electrical response evaluation validates the sensing capability, allowing to implement different alternatives for data analysis and reduce the sensing variability. In this work, a new tool capable of overcome the functionalization challenges of graphene surfaces is provided, paving the way toward the standardization of gSGFETs for biosensing purposes.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Ethanol Solvation of Polymer Residues in Graphene Solution-Gated Field Effect Transistors

  • Merino, Juan Pedro
  • Brosel-Oliu, Sergi
  • Rius, Gemma|||0000-0003-0552-1043
  • Illa, Xavi|||0000-0002-3212-1128
  • Vázque Sulleiro, Manuel|||0000-0002-9688-7771
  • Del Corro, Elena|||0000-0001-6452-9139
  • Masvidal Codina, Eduard|||0000-0002-9579-8603
  • Bonaccini Calia, Andrea|||0000-0002-7873-4296
  • Garrido, Jose|||0000-0001-5621-1067
  • Villa, Rosa|||0000-0003-2735-3204
  • Guimerà-Brunet, Anton
  • Prato, Maurizio|||0000-0002-8869-8612
  • Criado, Alejandro|||0000-0002-9732-513X
  • Prats Alfonso, Elisabet|||0000-0002-7320-1896
The persistence of photoresist residues from microfabrication procedures causes significant obstacles in the technological advancement of graphene-based electronic devices. These residues induce undesired chemical doping effects, diminish carrier mobility, and deteriorate the signal-to-noise ratio, making them critical in certain contexts, including sensing and electrical recording applications. In graphene solution-gated field-effect transistors (gSGFETs), the presence of polymer contaminants makes it difficult to perform precise electrical measurements, introducing response variability and calibration challenges. Given the absence of viable short to midterm alternatives to polymer-intensive microfabrication techniques, a postpatterning treatment involving THF and ethanol solvents was evaluated, with ethanol being the most effective, environmentally sustainable, and safe method for residue removal. Employing a comprehensive analysis with XPS, AFM, and Raman spectroscopy, together with electrical characterization, we investigated the influence of residual polymers on graphene surface properties and transistor functionality. Ethanol treatment exhibited a pronounced enhancement in gSGFET performance, as evidenced by a shift in the charge neutrality point and reduced dispersion. This systematic cleaning methodology holds the potential to improve the reproducibility and precision in the manufacturing of graphene devices. Particularly, by using ethanol for residue removal, we align our methodology with the principles of green chemistry, minimizing environmental impact while advancing diverse graphene technology applications.