Skip to main content

New generation of electronic devices based on low-dimensional materials

RYC2019-027879-I

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de Promoción del Talento y su Empleabilidad en I+D+i
Subprogram Subprograma Estatal de Incorporación
Call Ramón y Cajal
Call year 2019
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre FUNDACIÓ INSTITUT CATALÀ DE NANOCIÈNCIA I NANOTECNOLOGIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 18
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Graphene-based microelectrodes with bidirectional functionality for next-generation retinal electronic interfaces

  • Duvan, Fikret Taygun|||0000-0002-3377-9351
  • Cunquero, Marina|||0000-0001-8093-8186
  • Masvidal Codina, Eduard|||0000-0002-9579-8603
  • Walston, Steven T.|||0000-0003-4567-8926
  • Marsal, Maria|||0000-0001-9678-8717
  • de la Cruz, Jose Manuel
  • Viana, Damia|||0000-0001-8558-986X
  • Nguyen, Diep
  • Dégardin, Julie
  • Illa, Xavi|||0000-0002-3212-1128
  • Zhang, Julie Meng|||0000-0001-5985-3815
  • Bernicola, María del Pilar|||0000-0002-8124-2567
  • Macias Montero, Jose Gabriel
  • Puigdengoles, Carles|||0000-0002-1372-5452
  • Castro-Olvera, Gustavo|||0000-0001-9843-3581
  • Del Corro, Elena|||0000-0001-6452-9139
  • Dokos, Socrates
  • Chmeissani, Mokhtar|||0000-0002-2287-4791
  • Loza-Alvarez, Pablo|||0000-0002-3129-1213
  • Picaud, Serge|||0000-0002-0548-5145
  • Garrido, Jose|||0000-0001-5621-1067
Neuroelectronic prostheses are being developed for restoring vision at the retinal level in patients who have lost their sight due to photoreceptor loss. The core component of these devices is the electrode array, which enables interfacing with retinal neurons. Generating the perception of meaningful images requires high-density microelectrode arrays (MEAs) capable of precisely activating targeted retinal neurons. Achieving this precision necessitates the downscaling of electrodes to micrometer dimensions. However, miniaturization increases electrode impedance, which poses challenges by limiting the amount of current that can be delivered, thereby impairing the electrode's capability for effective neural modulation. Additionally, it elevates noise levels, reducing the signal quality of the recorded neural activity. This report focuses on evaluating reduced graphene oxide (rGO) based devices for interfacing with the retina, showcasing their potential in vision restoration. Our findings reveal low impedance and high charge injection limit for microscale rGO electrodes, confirming their suitability for developing next-generation high-density retinal devices. We successfully demonstrated bidirectional interfacing with cell cultures and explanted retinal tissue, enabling the identification and modulation of multiple cells' activity. Additionally, calcium imaging allowed real-time monitoring of retinal cell dynamics, demonstrating a significant reduction in activated areas with small-sized electrodes. Overall, this study lays the groundwork for developing advanced rGO-based MEAs for high-acuity visual prostheses.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Interfacial Phenomena Governing Performance of Graphene Electrodes in Aqueous Electrolyte

  • Delgà-Fernández, Marta|||0000-0001-7434-8593
  • Toral-Lopez, Alejandro|||0000-0001-5612-0536
  • Guimerà Brunet, Anton|||0000-0003-1768-3293
  • Pérez-Marín, Antonio Pablo|||0000-0003-1843-8273
  • Marin, Enrique G|||0000-0002-0302-3764
  • Godoy Medina, Andres|||0000-0002-3014-8765
  • Garrido, Jose|||0000-0001-5621-1067
  • Del Corro, Elena|||0000-0001-6452-9139
There is evidence of the presence of intercalated water between graphene and the substrate in electronic devices. However, a proper understanding of the impact of this phenomenon, which causes important limitations for the optimization of graphene-based devices operating in aqueous electrolytes, is missing. We used graphene-based electrodes on insulating and conducting substrates to evaluate the impact of intercalated water by combining experimental techniques with numerical simulations. Results show that the capacitance of the conductive substrate/graphene electrodes is significantly higher than that of the insulating substrate/graphene ones. Meanwhile, Raman spectroscopy demonstrates that graphene charge modulation with the applied potential is independent of the substrate conductivity. We found that this intriguing behavior is influenced by the water intercalation phenomena and governed by the substrate conductive nature. This work contributes to the understanding of the electric response of graphene-based devices in an aqueous environment and of the methods to measure and model it.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

The impact of graphene oxide nanosheet lateral dimensions on the electrochemical performance of nanoporous graphene-based electrodes

  • Bernicola, María del Pilar|||0000-0002-8124-2567
  • Madrid-Gimeno, Miquel
  • Murillo Cremaes, Nerea
  • Battisti, Tommaso
  • Lozano, Neus|||0000-0002-9026-1743
  • Kostarelos, Kostas|||0000-0002-2224-6672
  • Garrido, Jose|||0000-0001-5621-1067
  • Del Corro, Elena|||0000-0001-6452-9139
Electrodes based on nanoporous reduced graphene oxide (rGO) have been developed as the interfacing component in different designs of neural implants in a variety of therapeutic and monitoring applications. The starting graphene oxide (GO) nanosheets lateral dimensions influenced the staking order, roughness and thickness of the derived rGO films, including the formation of nanochannels. Apart from the morphological differences observed, the GO lateral dimension also impacted on the film conductivity, and on the overall electrochemical performance of the rGO electrodes. While electrodes fabricated from nano-scale GO sheets (us-GO) only showed diffusion-limited impedance in the high frequency regime, the electrical response of electrodes from micron-scale GO sheets (L-GO) was limited by diffusion in the whole frequency range due to a less disordered nanoporous film. At 1 kHz, us-GO electrodes, due to their larger capacitance, presented a higher charge injection limit (Qinj.l.) than L-GO electrodes. Due to the higher conductivity of L-GO, electrodes exhibited half the ohmic drop (IR) of electrodes made of us-GO,. This work highlights the importance of GO nanosheet engineering to optimize the performance of rGO electrodes in terms of Qinj.l. and IR, two key figures of merit in neuroelectronic applications.
RUC. Repositorio da Universidade da Coruña
Publication Artículo científico (JournalArticle)

Ethanol Solvation of Polymer Residues in Graphene Solution-Gated Field Effect Transistors

  • Merino, Juan P.
  • Vázquez Sulleiro, Manuel
  • Criado, Alejandro
  • Prato, Maurizio
  • Prats Alfonso, Elisabet
[Abstract] The persistence of photoresist residues from microfabrication procedures causes significant obstacles in the technological advancement of graphene-based electronic devices. These residues induce undesired chemical doping effects, diminish carrier mobility, and deteriorate the signal-to-noise ratio, making them critical in certain contexts, including sensing and electrical recording applications. In graphene solution-gated field-effect transistors (gSGFETs), the presence of polymer contaminants makes it difficult to perform precise electrical measurements, introducing response variability and calibration challenges. Given the absence of viable short to midterm alternatives to polymer-intensive microfabrication techniques, a postpatterning treatment involving THF and ethanol solvents was evaluated, with ethanol being the most effective, environmentally sustainable, and safe method for residue removal. Employing a comprehensive analysis with XPS, AFM, and Raman spectroscopy, together with electrical characterization, we investigated the influence of residual polymers on graphene surface properties and transistor functionality. Ethanol treatment exhibited a pronounced enhancement in gSGFET performance, as evidenced by a shift in the charge neutrality point and reduced dispersion. This systematic cleaning methodology holds the potential to improve the reproducibility and precision in the manufacturing of graphene devices. Particularly, by using ethanol for residue removal, we align our methodology with the principles of green chemistry, minimizing environmental impact while advancing diverse graphene technology applications., This work has made use of the Spanish ICTS Network MICRONANOFABS, partially supported by MICINN and the ICTS NANBIOSIS, more specifically by the Micro-NanoTechnology Unit U8 of the CIBER-BBN. This research was funded by the European Union’s Horizon 2020 research and innovation programme under Grant Agreement No. 881603 (GrapheneCore3) and No. 785219 (GrapheneCore2). We also acknowledge funding from the Generalitat de Catalunya (2021SGR00495 and 2021SGR001534). G.R. thanks the Ayuda RYC-2016-21412, and E.dC thanks the Ayuda RYC2019-027879-I founded by MCIU/AEI/10.13039/501100011033 and by El FSE invierte en tu futuro. E.M.-C. acknowledges Ayuda FJC2021-046601-I financiada por MCIU/AEI/10.13039/501100011033 y por la Unión Europea NextGenerationEU/PRTR. This research was funded by the Spanish Ministerio de Ciencia e Innovación (PID2021-126117NA-I00, PID2020-113663RB-I00, PLEC2022-009232) founded by MCIU/AEI/10.13039/501100011033) and by “ERDF A way of making Europe”, also this work was funded by CIBER-BBN (CB06/01/0049). In addition, this work has been funded by PLEC2022-009232 funded by MCIU/AEI/ 10.13039/501100011033 and by the European Union NextGenerationEU/PRTR. The authors acknowledge the financial support provided by CIBER-BBN and the Instituto de Salud Carlos III with assistance from the European Regional Development. M.V.S. thanks Xunta de Galicia (ED481B-2023-126). A.C. acknowledges financial support by Grant ED431H 2020/17 funded by Xunta de Galicia, and by Grant RYC2020-030183-I funded by MCIN/AEI/10.13039/501100011033 and “ESF Investing in your future”. Part of this work was performed under the Maria de Maeztu Units of Excellence Program grant MDM-2017-0720 funded by MCIN/AEI/10.13039/501100011033 and supported by the Severo Ochoa Centres of Excellence programme [SEV-2017-0706] and is currently supported by the Severo Ochoa Centres of Excellence programme, Grant CEX2021-001214-S, both funded by MCIN and MCIU/AEI/10.13039.501100011033. M.P. as recipient of the AXA Chair is grateful to AXA Chair in Nanobiotechnology supported by the AXA Research Fund., Generalitat de Catalunya; 2021SGR00495, Generalitat de Catalunya; 2021SGR001534, Xunta de Galicia; ED481B-2023-126, Xunta de Galicia; ED431H 2020/17
RUC. Repositorio da Universidade da Coruña
Publication Artículo científico (JournalArticle)

Single-Step Functionalization Strategy of Graphene Microtransistor Array with Chemically Modified Aptamers for Biosensing Applications

  • Brosel, Sergi
  • Rius, Gemma
  • Aviñó, Ana
  • Nako, Nakatsuka
  • Illa, Xavi
  • Corro, Elena del
  • Delgà-Fernández, Marta
  • Criado, Alejandro
  • Guimerà, Anton
  • Prats Alfonso, Elisabet
[Abstract]: Graphene solution-gated field-effect transistors (gSGFETs) offer high potential for chemical and biochemical sensing applications. Among the current trends to improve this technology, the functionalization processes are gaining relevance for its crucial impact on biosensing performance. Previous efforts are focused on simplifying the attachment procedure from standard multi-step to single-step strategies, but they still suffer from overreaction, and impurity issues and are limited to a particular ligand. Herein, a novel strategy for single-step immobilization of chemically modified aptamers with fluorenylmethyl and acridine moieties, based on a straightforward synthetic route to overcome the aforementioned limitations is presented. This approach is benchmarked versus a standard multi-step strategy using thrombin as detection model. In order to assess the reliability of the functionalization strategies 48-gSGFETs arrays are employed to acquire large datasets with multiple replicas. Graphene surface characterization demonstrates robust and higher efficiency in the chemical coupling of the aptamers with the single-step strategy, while the electrical response evaluation validates the sensing capability, allowing to implement different alternatives for data analysis and reduce the sensing variability. In this work, a new tool capable of overcome the functionalization challenges of graphene surfaces is provided, paving the way toward the standardization of gSGFETs for biosensing purposes., This work has received funding from the European Union's Horizon 2020 research and innovation programme under grant agreement no. 881603 (GrapheneCore3) and no. 785219 (GrapheneCore2). M. P. is AXA Professor and is supported by the European Research Council (ERC-AdG-2019, no. 885323), the Agencia Estatal de Investigación-AEI (“Proyectos I+D+i 2019-Modalidad Retos Investigación”, no. PID2019-108523RB-I00), by grant PRE2020-095099 funded by MCIN/AEI/10.13039/501100011033 and by “ESF Investing in your future.” Part of this work has made use of the Spanish ICTS Network MICRONANOFABS, partially supported by MICINN and the ICTS NANBIOSIS, more specifically by the Micro-NanoTechnology Unit U8 of the CIBER-BBN. This project was also funded by the Generalitat de Catalunya (2021SGR00495), by the Spanish Ministerio de Ciencia e Innovación (PID2021-126117NA-I00), by “ERDF A way of making Europe”, and by CIBER-BBN (CB06/01/0049). X. I., R. V., A. G. and E. P.-A. thank the financial support provided by CIBER-BBN and the Instituto de Salud Carlos III with assistance from the European Regional Development. A. C. acknowledges financial support by Grant ED431H 2020/17 funded by Xunta de Galicia, and by Grant RYC2020-030183-I funded by MCIN/AEI/10.13039/501100011033 and “ESF Investing in your future”., Generalitat de Catalunya; 2021SGR00495
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Single-Step Functionalization Strategy of Graphene Microtransistor Array with Chemically Modified Aptamers for Biosensing Applications

  • Brosel-Oliu, Sergi
  • Rius, Gemma
  • Aviñó, Anna
  • Nakatsuka, Nako
  • Illa, Xavi
  • Del Corro, Elena
  • Delgà-Fernández, Marta
  • Masvidal Codina, Eduard
  • Rodríguez, Natalia
  • Merino, Juan Pedro
  • Criado, Alejandro
  • Prato, Maurizio
  • Tkatchenko, Raphaela
  • Eritja, Ramón
  • Godignon, Philippe
  • Garrido, José Antonio
  • Villa, Rosa
  • Guimerà, Anton
  • Prats-Alfonso, Elisabet
Graphene solution-gated field-effect transistors (gSGFETs) offer high potential for chemical and biochemical sensing applications. Among the current trends to improve this technology, the functionalization processes are gaining relevance for its crucial impact on biosensing performance. Previous efforts are focused on simplifying the attachment procedure from standard multi-step to single-step strategies, but they still suffer from overreaction, and impurity issues and are limited to a particular ligand. Herein, a novel strategy for single-step immobilization of chemically modified aptamers with fluorenylmethyl and acridine moieties, based on a straightforward synthetic route to overcome the aforementioned limitations is presented. This approach is benchmarked versus a standard multi-step strategy using thrombin as detection model. In order to assess the reliability of the functionalization strategies 48-gSGFETs arrays are employed to acquire large datasets with multiple replicas. Graphene surface characterization demonstrates robust and higher efficiency in the chemical coupling of the aptamers with the single-step strategy, while the electrical response evaluation validates the sensing capability, allowing to implement different alternatives for data analysis and reduce the sensing variability. In this work, a new tool capable of overcome the functionalization challenges of graphene surfaces is provided, paving the way toward the standardization of gSGFETs for biosensing purposes., This work has made use of the Spanish ICTS Network MICRONANOFABS, partially supported by MICINN and the ICTS NANBIOSIS, more specifically by the Micro-NanoTechnology Unit U8 and the Oligonucleotide synthesis platform U29 of the CIBER-BBN. This work has received funding from the European Union's Horizon 2020 research and innovation programme under Grant Agreement No. 881603 (GrapheneCore3) and No. 785219 (GrapheneCore2). The authors also acknowledge funding from the Generalitat de Catalunya (2021SGR00495). G.R. thanks to the Ayuda RYC-2016-21412, E.dC thanks to the Ayuda RYC2019-027879-I and A.C. thanks to RYC2020-030183-I founded by MCIN/AEI /10.13039/501100011033 and by El FSE invierte en tu futuro.M.P. as recipient of the AXA Chair, is grateful to AXA Chair in Nanobiotechnology supported by the AXA Research Fund. This research was funded by the Spanish Ministerio de Ciencia e Innovación (PID2020-118145RB-I00, PID2021-126117NA-I00) and by “ERDF A way of making Europe”, also this work was funded by CIBER-BBN (CB06/01/0019 & CB06/01/0049). Part of this work was performed under the Maria de Maeztu Units of Excellence Program grant MDM-2017-0720 funded by MCIN/AEI/10.13039/501100011033. The authors acknowledge the financial support provided by CIBER-BBN and the Instituto de Salud Carlos III with assistance from the European Regional Development., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Nanoporous graphene-based thin-film microelectrodes for in vivo high-resolution neural recording and stimulation

  • Viana, Damià
  • Walston, Steven T.
  • Masvidal Codina, Eduard
  • Illa, Xavi
  • Rodríguez-Meana, Bruno
  • Valle, Jaume del
  • Hayward, Andrew
  • Dodd, Abbie
  • Loret, Thomas
  • Prats Alfonso, Elisabet
  • Oliva, Natàlia de la
  • Palma, Marie
  • Del Corro, Elena
  • Bernicola, María del Pilar
  • Rodríguez-Lucas, Elisa
  • Gener, Thomas
  • Cruz, Jose Manuel de la
  • Torres-Miranda, Miguel
  • Duvan, F. Taygun
  • Ria, Nicola
  • Sperling, Justin R.
  • Martí-Sànchez, Sara
  • Spadaro, Maria Chiara
  • Hébert, Clement
  • Savage, Sinead
  • Arbiol, Jordi
  • Guimerà-Brunet, Anton
  • Puig, M. Victoria
  • Yvert, Blaise
  • Navarro, Xavier
  • Kostarelos, Kostas
  • Garrido, Jose A.
One of the critical factors determining the performance of neural interfaces is the electrode material used to establish electrical communication with the neural tissue, which needs to meet strict electrical, electrochemical, mechanical, biological and microfabrication compatibility requirements. This work presents a nanoporous graphene-based thin-film technology and its engineering to form flexible neural interfaces. The developed technology allows the fabrication of small microelectrodes (25 µm diameter) while achieving low impedance (∼25 kΩ) and high charge injection (3–5 mC cm−2). In vivo brain recording performance assessed in rodents reveals high-fidelity recordings (signal-to-noise ratio >10 dB for local field potentials), while stimulation performance assessed with an intrafascicular implant demonstrates low current thresholds (<100 µA) and high selectivity (>0.8) for activating subsets of axons within the rat sciatic nerve innervating tibialis anterior and plantar interosseous muscles. Furthermore, the tissue biocompatibility of the devices was validated by chronic epicortical (12 week) and intraneural (8 week) implantation. This work describes a graphene-based thin-film microelectrode technology and demonstrates its potential for high-precision and high-resolution neural interfacing., This work has been funded by the European Union Horizon 2020 Research and Innovation programme under grant agreement number 881603 (Graphene Core3); FLAG-ERA JTC 2021 project RESCUEGRAPH, from the Agencia Estatal de Investigación of Spain PCI2021-122075-2A y PCI2021-122095-2A financiados por MCIN/AEI/10.13039/501100011033 y por la Unión Europea NextGenerationEU/PRTR; TERCEL (RD12/0019/0011), CIBERNED (CB06/05/1105) and CIBER-BBN (CB06/01/0049) funds from the Instituto de Salud Carlos III of Spain, Proyecto PID2020-113663RB-I00 financiado por MCIN/AEI/10.13039/501100011033, from the Generalitat de Catalunya (2021SGR00495) and from the European Union’s Horizon Europe research and innovation programme under grant agreement number 101070865 (MINIGRAPH). The ICN2 is supported by the Severo Ochoa Centres of Excellence programme, Grant CEX2021-001214-S, funded by MCIN/AEI/10.13039.501100011033, and by the CERCA Programme/Generalitat de Catalunya. D.V. and S.M.-S. have been supported by the International PhD Programme La Caixa–Severo Ochoa (Programa Internacional de Becas ‘la Caixa’–Severo Ochoa). D.V. acknowledges that this work has been done in the framework of a PhD in electrical and telecommunication engineering at the Universitat Autònoma de Barcelona. J.d.V. acknowledges the Ministerio de Economía, Industria y Competitividad of Spain for Juan de la Cierva incorporation fellowship. M.C.S. received funding from the European Union Horizon 2020 under the Marie Sklodowska-Curie grant agreement number 754510 (PROBIST). E.d.C. acknowledges Ayuda RYC2019-027879-I financiada por MCIN/AEI/10.13039/501100011033 y por El FSE invierte en tu futuro. N.R. acknowledges Ayuda PRE2020-093708 financiada por MCIN/AEI/10.13039/501100011033 y por FSE invierte en tu futuro. E.M.-C. acknowledges Ayuda FJC2021-046601-I financiada por MCIN/AEI/10.13039/501100011033 y por la Unión Europea NextGenerationEU/PRTR. Authors acknowledge M. Ezcurdia for assistance in the bending experiments. S.M.-S and J.A. acknowledge funding from Generalitat de Catalunya 2021SGR00457. This study is part of the Advanced Materials programme and was supported by MCIN with funding from European Union NextGenerationEU (PRTR-C17.I1) and by Generalitat de Catalunya. This work has made use of the Spanish ICTS Network MICRONANOFABS partially supported by MICINN and the ICTS ‘NANBIOSIS’, more specifically by the Micro-NanoTechnology Unit of the CIBER-BBN at the IMB-CNM. Part of the present work has been performed in the framework of Universitat Autònoma de Barcelona Materials Science PhD programme and Neuroscience PhD programme. The focused ion beam sample preparation was conducted in the Laboratorio de Microscopias Avanzadas at Instituto de Nanociencia de Aragon-Universidad de Zaragoza. Authors acknowledge the LMA-INA for offering access to their instruments and expertise. This study was also financed by grant PID2019-104683RB-I00 funded by MCIN/AEI/10.13039/501100011033 to M.V.P. The authors would like to acknowledge P. Nebot for technical assistance. The authors would also like to thank C. Bullock and C. Bussy for their contributions during the early stages of the project. The University of Manchester Bioimaging and Single Cell Genomics Facility microscopes used in this study were purchased with grants from the UKRI Biotechnology and Biological Sciences Research Council (BBSRC), the Wellcome Trust and the University of Manchester Strategic Fund. The RT97 antibody was obtained from the Developmental Studies Hybridoma Bank developed under the auspices of the NICHD and maintained by the University of Iowa, Department of Biology., With funding from the Spanish government through the "Severo Ochoa Centre of Excellence" accreditation (CEX2021-001214-S)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Ethanol solvation of polymer residues in graphene solution-gated field effect transistors

  • Merino, Juan Pedro
  • Brosel-Oliu, Sergi
  • Rius, Gemma
  • Illa, Xavi
  • Vázquez Sulleiro, Manuel
  • Del Corro, Elena
  • Masvidal Codina, Eduard
  • Bonaccini Calia, Andrea
  • Garrido, Jose A.
  • Villa, Rosa
  • Guimerà-Brunet, Anton
  • Prato, Maurizio
  • Criado, Alejandro
  • Prats Alfonso, Elisabet
The persistence of photoresist residues from microfabrication procedures causes significant obstacles in the technological advancement of graphene-based electronic devices. These residues induce undesired chemical doping effects, diminish carrier mobility, and deteriorate the signal-to-noise ratio, making them critical in certain contexts, including sensing and electrical recording applications. In graphene solution-gated field-effect transistors (gSGFETs), the presence of polymer contaminants makes it difficult to perform precise electrical measurements, introducing response variability and calibration challenges. Given the absence of viable short to midterm alternatives to polymer-intensive microfabrication techniques, a postpatterning treatment involving THF and ethanol solvents was evaluated, with ethanol being the most effective, environmentally sustainable, and safe method for residue removal. Employing a comprehensive analysis with XPS, AFM, and Raman spectroscopy, together with electrical characterization, we investigated the influence of residual polymers on graphene surface properties and transistor functionality. Ethanol treatment exhibited a pronounced enhancement in gSGFET performance, as evidenced by a shift in the charge neutrality point and reduced dispersion. This systematic cleaning methodology holds the potential to improve the reproducibility and precision in the manufacturing of graphene devices. Particularly, by using ethanol for residue removal, we align our methodology with the principles of green chemistry, minimizing environmental impact while advancing diverse graphene technology applications., This work has made use of the Spanish ICTS Network MICRONANOFABS, partially supported by MICINN and the ICTS NANBIOSIS, more specifically by the Micro-NanoTechnology Unit U8 of the CIBER-BBN. This research was funded by the European Union’s Horizon 2020 research and innovation programme under Grant Agreement No. 881603 (GrapheneCore3) and No. 785219 (GrapheneCore2). We also acknowledge funding from the Generalitat de Catalunya (2021SGR00495 and 2021SGR001534). G.R. thanks the Ayuda RYC-2016-21412, and E.dC thanks the Ayuda RYC2019-027879-I founded by MCIU/AEI/10.13039/501100011033 and by El FSE invierte en tu futuro. E.M.-C. acknowledges Ayuda FJC2021-046601-I financiada por MCIU/AEI/10.13039/501100011033 y por la Unión Europea NextGenerationEU/PRTR. This research was funded by the Spanish Ministerio de Ciencia e Innovación (PID2021-126117NA-I00, PID2020-113663RB-I00, PLEC2022-009232) founded by MCIU/AEI/10.13039/501100011033) and by “ERDF A way of making Europe”, also this work was funded by CIBER-BBN (CB06/01/0049). In addition, this work has been funded by PLEC2022-009232 funded by MCIU/AEI/ 10.13039/501100011033 and by the European Union NextGenerationEU/PRTR. The authors acknowledge the financial support provided by CIBER-BBN and the Instituto de Salud Carlos III with assistance from the European Regional Development. M.V.S. thanks Xunta de Galicia (ED481B-2023-126). A.C. acknowledges financial support by Grant ED431H 2020/17 funded by Xunta de Galicia, and by Grant RYC2020-030183-I funded by MCIN/AEI/10.13039/501100011033 and “ESF Investing in your future”. Part of this work was performed under the Maria de Maeztu Units of Excellence Program grant MDM-2017-0720 funded by MCIN/AEI/10.13039/501100011033 and supported by the Severo Ochoa Centres of Excellence programme [SEV-2017-0706] and is currently supported by the Severo Ochoa Centres of Excellence programme, Grant CEX2021-001214-S, both funded by MCIN and MCIU/AEI/10.13039.501100011033. M.P. as recipient of the AXA Chair is grateful to AXA Chair in Nanobiotechnology supported by the AXA Research Fund., With funding from the Spanish government through the "Severo Ochoa Centre of Excellence" accreditation (CEX2021-001214-S)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Graphene-based microelectrodes with bidirectional functionality for next-generation retinal electronic interfaces

  • Duvan, F. Taygun
  • Cunquero, Marina
  • Masvidal Codina, Eduard
  • Walston, Steven T.
  • Marsal, María
  • Cruz, Jose Manuel de la
  • Viana, Damià
  • Nguyen, Diep
  • Degardin, Julie
  • Illa, Xavi
  • Zhang, Julie M.
  • Bernicola, María del Pilar
  • Macías-Montero, José Gabriel
  • Puigdengoles, Carles
  • Castro-Olvera, Gustavo
  • Del Corro, Elena
  • Dokos, Socrates
  • Chmeissani, Mokhtar
  • Loza-Álvarez, Pablo
  • Picaud, Serge
  • Garrido, Jose A.
This article is part of the themed collection: Graphene and 2D Materials in Healthcare., Neuroelectronic prostheses are being developed for restoring vision at the retinal level in patients who have lost their sight due to photoreceptor loss. The core component of these devices is the electrode array, which enables interfacing with retinal neurons. Generating the perception of meaningful images requires high-density microelectrode arrays (MEAs) capable of precisely activating targeted retinal neurons. Achieving this precision necessitates the downscaling of electrodes to micrometer dimensions. However, miniaturization increases electrode impedance, which poses challenges by limiting the amount of current that can be delivered, thereby impairing the electrode's capability for effective neural modulation. Additionally, it elevates noise levels, reducing the signal quality of the recorded neural activity. This report focuses on evaluating reduced graphene oxide (rGO) based devices for interfacing with the retina, showcasing their potential in vision restoration. Our findings reveal low impedance and high charge injection limit for microscale rGO electrodes, confirming their suitability for developing next-generation high-density retinal devices. We successfully demonstrated bidirectional interfacing with cell cultures and explanted retinal tissue, enabling the identification and modulation of multiple cells' activity. Additionally, calcium imaging allowed real-time monitoring of retinal cell dynamics, demonstrating a significant reduction in activated areas with small-sized electrodes. Overall, this study lays the groundwork for developing advanced rGO-based MEAs for high-acuity visual prostheses., The project leading to these results have received funding from “la Caixa” Foundation (ID 100010434), under the agreement LCF/PR/HR19/52160003 (i-VISION), European Unions Horizon 2020 research and innovation programme under grant agreement no. 881603 (Graphene flagship Core3), and French state funds managed by the Agence Nationale de la Recherche (ANR) within Programme Investissements dAvenir, Laboratoire dExcellence (LABEX) LIFESENSES (ANR-10-LABX-0065) and Institut Hospitalo-Universitaire FOReSIGHT (ANR-18-IAHU-0001). We also acknowledge funding from the Generalitat de Catalunya (2021SGR001534). E. D. C. thanks the Ayuda RYC2019-027879-I founded by MCIU/AEI/10.13039/501100011033 and by El FSE invierte en tu futuro. E. M. C. acknowledges Ayuda FJC2021-046601-I financiada por MCIU/AEI/10.13039/501100011033 y por la Unión Europea NextGenerationEU/PRTR. This research was funded by the Spanish Ministerio de Ciencia e Innovación (PID2020-113663RB-I00) founded by (MCIU/AEI/10.13039/501100011033) and by “ERDF A way of making Europe”. The ICN2 has been supported by the Severo Ochoa Centres of Excellence programme [SEV-2017-0706] and is currently supported by the Severo Ochoa Centres of Excellence programme, Grant CEX2021-001214-S, both funded by MCIN and MCIU/AEI/10.13039.501100011033. This project has also received funding from the European Unions Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement no. 861423 (enTRAIN Vision). Part of this work was performed at the Spanish ICTS Network MICRONANOFABS partially supported by MICINN, and the ICTS ‘NANBIOSIS’, more specifically by the Micro-NanoTechnology Unit of the CIBER in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN) at the IMB-CNM. DN has received funding from the doctoral school of Cerveau, cognition, comportement (3C) at Sorbonne Université., With funding from the Spanish government through the "Severo Ochoa Centre of Excellence" accreditation (CEX2021-001214-S)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Interfacial phenomena governing performance of graphene electrodes in aqueous electrolyte

  • Delgà-Fernández, Marta
  • Toral-Lopez, Alejandro
  • Guimerà-Brunet, Anton
  • Pérez-Marín, Antonio Pablo
  • Marin, Enrique G.
  • Godoy, Andrés
  • Garrido, Jose A.
  • Del Corro, Elena
There is evidence of the presence of intercalated water between graphene and the substrate in electronic devices. However, a proper understanding of the impact of this phenomenon, which causes important limitations for the optimization of graphene-based devices operating in aqueous electrolytes, is missing. We used graphene-based electrodes on insulating and conducting substrates to evaluate the impact of intercalated water by combining experimental techniques with numerical simulations. Results show that the capacitance of the conductive substrate/graphene electrodes is significantly higher than that of the insulating substrate/graphene ones. Meanwhile, Raman spectroscopy demonstrates that graphene charge modulation with the applied potential is independent of the substrate conductivity. We found that this intriguing behavior is influenced by the water intercalation phenomena and governed by the substrate conductive nature. This work contributes to the understanding of the electric response of graphene-based devices in an aqueous environment and of the methods to measure and model it., M.D.-F. acknowledges that this work has been done within the framework of the Ph.D. program in Materials Science of the Autonomous University of Barcelona. This work has received funding from the Spanish State Research Agency through PRE2018-086251 funded by MCIN/AEI/10.13039/501100011033 and FSE, UE, the PID2020-113663RB-I00 funded by MCIN/AEI/10.13039/501100011033 and the European Union’s Horizon 2020 research and innovation programs under Grant Agreement No. 881603 (Graphene Flagship Core Project 3). This work is supported by the Generalitat de Catalunya (2021-SGR-01534) and the Spanish Government through Project PID2020-116518GB-I00 funded by MCIN/AEI/10.13039/501100011033 and Project TED2021-129769B-I00 funded by MCIN/AEI/10.13039/501100011033 by the European Union NextGenerationEU/PRTR. Part of this work has made use of the Spanish ICTS Network MICRONANOFABS, partially supported by MICINN and the ICTS NANBIOSIS, more specifically, by the MicroNanoTechnology Unit U8 of the CIBER-BBN. This project has also been funded by the Generalitat de Catalunya (2021SGR00495), by the Spanish Ministerio de Ciencia e Innovación (PID2021-126117NA-I00, PLEC2022-009232,), and by CIBER-BBN (CB06/01/0049). E.d.C. acknowledges the RYC2019-027879-I Grant funded by MCIN/AEI/10.13039/501100011033., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

On the Electrochemical Activation of Nanoporous Reduced Graphene Oxide Electrodes Studied by In Situ/Operando Electrochemical Techniques

  • Bernicola, María del Pilar
  • Lounasvuori, Mailis
  • Padilla-Pantoja, Jessica
  • Santiso, José
  • Debiemme-Chouvy, Catherine
  • Perrot, Hubert
  • Petit, Tristan
  • Garrido, Jose A.
  • Corro, Elena del
Due to the difficult access of the electrolyte into the nanoconfined space of nanoporous reduced graphene oxide (rGO) electrodes, achieving the optimal electrochemical performance of these devices becomes a challenge. In this work, the dynamics of interfacial-governed phenomena are investigated during a voltage-controlled electrochemical activation of nanoporous rGO electrodes that leads to an enhanced electrochemical performance in terms of areal capacitance and electrochemical impedance. In situ/operando characterization techniques are used to reveal the dynamics of the irreversible material changes introduced during the activation process, including ionic diffusion and water confinement within the nanopores, along with the reduction of oxygenated groups and the decrease of the rGO interlayer distance. Furthermore, operando techniques are used to uncover the origin of the complex polarization-dependent dynamic response of rGO electrodes. The study reveals that the reversible protonation/deprotonation of remaining functional groups and the cation electro-adsorption/desorption process in the graphene basal plane govern the pseudocapacitive performance of nanoporous rGO electrodes. This work brings new understanding of the complex interplay between surface chemistry, ion confinement, and desolvation processes occurring during electrochemical cycling in nanoporous rGO electrodes, offering new insights for designing high-performing electrodes based on nanoporous rGO., Part of the present work has been performed in the framework of Universitat Autònoma de Barcelona Materials Science PhD programme; This work has received funding from the European Union's Horizon 2020 research and innovation programme under grant agreement N° 825213 (WASP); the European Union's Horizon 2020 research and innovation programme under grant agreement N° 881603 (GrapheneCore3); the European Union's Horizon 2020 research and innovation programme under grant agreement N° 101070865 (MINIGRAPH); and MCIN/ AEI /10.13039/501100011033 under grant agreement PID2020-113663RB-I00. E.d.C. acknowledges the RYC2019-027879-I Grant funded by MCIN/AEI/10.13039/501100011033., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

The impact of graphene oxide nanosheet lateral dimensions on the electrochemical performance of nanoporous graphene-based electrodes

  • Bernicola, María del Pilar
  • Madrid-Gimeno, Miquel
  • Murillo-Cremaes, Nerea
  • Battisti, Tommaso
  • Lozano, Neus
  • Kostarelos, Kostas
  • Garrido, Jose A.
  • Corro, Elena del
Electrodes based on nanoporous reduced graphene oxide (rGO) have been developed as the interfacing component in different designs of neural implants in a variety of therapeutic and monitoring applications. The starting graphene oxide (GO) nanosheets lateral dimensions influenced the staking order, roughness and thickness of the derived rGO films, including the formation of nanochannels. Apart from the morphological differences observed, the GO lateral dimension also impacted on the film conductivity, and on the overall electrochemical performance of the rGO electrodes. While electrodes fabricated from nano-scale GO sheets (us-GO) only showed diffusion-limited impedance in the high frequency regime, the electrical response of electrodes from micron-scale GO sheets (L-GO) was limited by diffusion in the whole frequency range due to a less disordered nanoporous film. At 1 kHz, us-GO electrodes, due to their larger capacitance, presented a higher charge injection limit (Qinj.l.) than L-GO electrodes. Due to the higher conductivity of L-GO, electrodes exhibited half the ohmic drop (IR) of electrodes made of us-GO. This work highlights the importance of GO nanosheet engineering to optimize the performance of rGO electrodes in terms of Qinj.l. and IR, two key figures of merit in neuroelectronic applications., Part of the present work has been performed in the framework of Universitat Autònoma de Barcelona Materials Science PhD programme. This work has received funding from the European Union's Horizon 2020 Research and Innovation Programme under grant agreement No 825213 (WASP); the European Union's Horizon 2020 research and innovation programme under grant agreement No 881603 (GrapheneCore3); the European Union's Horizon 2020 research and innovation programme under grant agreement No 101070865 (MINIGRAPH); and MCIN/AEI /10.13039/501100011033 under grant agreement PID2020-113663RB-I00. E.d.C. acknowledges the RYC2019-027879-I Grant funded by MCIN/AEI/10.13039/501100011033. The ICN2 is funded by the CERCA programme/Generalitat de Catalunya and has been supported by the Severo Ochoa Centres of Excellence programme [SEV-2017-0706] and is currently supported by the Severo Ochoa Centres of Excellence programme, Grant CEX2021-001214-S, both funded by MCIN and MCIU/AEI/10.13039.501100011033., With funding from the Spanish government through the "Severo Ochoa Centre of Excelence" accreditation (CEX2021-001214-S), With funding from the Spanish government through the "Severo Ochoa Centre of Excelence" accreditation (SEV-2017-0706), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Research data Set de datos (Dataset)

Replication data for Ethanol Solvation of Polymer Residues in Graphene Solution-Gated Field Effect Transistors, Ethanol solvation of polymer residues in graphene solution-gated field effect transistors JP Merino, S Brosel-Oliu, G Rius, X Illa, MV Sulleiro… - ACS sustainable chemistry & engineering, 2024

  • Merino, Juan Pedro
  • Brosel-Oliu, Sergi
  • Rius, Gemma
  • Illa, Xavi
  • Vázquez Sulleiro, Manuel
  • Del Corro, Elena
  • Masvidal Codina, Eduard
  • Bonaccini Calia, Andrea
  • Garrido, Jose A.
  • Villa, Rosa
  • Guimerà-Brunet, Anton
  • Prato, Maurizio
  • Criado, Alejandro
  • Prats Alfonso, Elisabet
The persistence of photoresist residues from microfabrication procedures causes significant obstacles in the technological advancement of graphene-based electronic devices. These residues induce undesired chemical doping effects, diminish carrier mobility, and deteriorate the signal-to-noise ratio, making them critical in certain contexts, including sensing and electrical recording applications. In graphene solution-gated field-effect transistors (gSGFETs), the presence of polymer contaminants makes it difficult to perform precise electrical measurements, introducing response variability and calibration challenges. Given the absence of viable short to midterm alternatives to polymer-intensive microfabrication techniques, a postpatterning treatment involving THF and ethanol solvents was evaluated, with ethanol being the most effective, environmentally sustainable, and safe method for residue removal. Employing a comprehensive analysis with XPS, AFM, and Raman spectroscopy, together with electrical characterization, we investigated the influence of residual polymers on graphene surface properties and transistor functionality. Ethanol treatment exhibited a pronounced enhancement in gSGFET performance, as evidenced by a shift in the charge neutrality point and reduced dispersion. This systematic cleaning methodology holds the potential to improve the reproducibility and precision in the manufacturing of graphene devices. Particularly, by using ethanol for residue removal, we align our methodology with the principles of green chemistry, minimizing environmental impact while advancing diverse graphene technology applications., This work has made use of the Spanish ICTS Network MICRONANOFABS, partially supported by MICINN and the ICTS NANBIOSIS, more specifically by the Micro-NanoTechnology Unit U8 of the CIBER-BBN. This research was funded by the European Union’s Horizon 2020 research and innovation programme under Grant Agreement No. 881603 (GrapheneCore3) and No. 785219 (GrapheneCore2). We also acknowledge funding from the Generalitat de Catalunya (2021SGR00495 and 2021SGR001534). G.R. thanks the Ayuda RYC-2016-21412, and E.dC thanks the Ayuda RYC2019-027879-I founded by MCIU/AEI/10.13039/501100011033 and by El FSE invierte en tu futuro. E.M.-C. acknowledges Ayuda FJC2021-046601-I financiada por MCIU/AEI/10.13039/501100011033 y por la Unión Europea NextGenerationEU/PRTR. This research was funded by the Spanish Ministerio de Ciencia e Innovación (PID2021-126117NA-I00, PID2020-113663RB-I00, PLEC2022-009232) founded by MCIU/AEI/10.13039/501100011033) and by “ERDF A way of making Europe”, also this work was funded by CIBER-BBN (CB06/01/0049). In addition, this work has been funded by PLEC2022-009232 funded by MCIU/AEI/ 10.13039/501100011033 and by the European Union NextGenerationEU/PRTR. The authors acknowledge the financial support provided by CIBER-BBN and the Instituto de Salud Carlos III with assistance from the European Regional Development. M.V.S. thanks Xunta de Galicia (ED481B-2023-126). A.C. acknowledges financial support by Grant ED431H 2020/17 funded by Xunta de Galicia, and by Grant RYC2020-030183-I funded by MCIN/AEI/10.13039/501100011033 and “ESF Investing in your future”. Part of this work was performed under the Maria de Maeztu Units of Excellence Program grant MDM-2017-0720 funded by MCIN/AEI/10.13039/501100011033 and supported by the Severo Ochoa Centres of Excellence programme [SEV-2017-0706] and is currently supported by the Severo Ochoa Centres of Excellence programme, Grant CEX2021-001214-S, both funded by MCIN and MCIU/AEI/10.13039.501100011033. M.P. as recipient of the AXA Chair is grateful to AXA Chair in Nanobiotechnology supported by the AXA Research Fund., No
Dipòsit Digital de Documents de la UAB
Publication Artículo preliminar (WorkingPaper)

Heat dissipation in few-layer MoS2 and MoS2/hBN heterostructure

  • Arrighi, Aloïs|||0000-0002-9774-852X
  • Del Corro, Elena|||0000-0001-6452-9139
  • Navarro Urrios, Daniel|||0000-0001-9055-1583
  • Costache, Marius Vasile|||0000-0001-7432-6175
  • Sierra, Juan F.|||0000-0002-5438-0534
  • Watanabe, Kenji|||0000-0003-3701-8119
  • Taniguchi, Takashi|||0000-0002-1467-3105
  • Garrido, Jose|||0000-0001-5621-1067
  • Valenzuela, Sergio O.|||0000-0002-4632-8891
  • Sotomayor Torres, Clivia M.|||0000-0001-9986-2716
  • Sledzinska, Marianna|||0000-0001-8592-1121
State-of-the-art fabrication and characterization techniques have been employed to measure the thermal conductivity of suspended, single-crystalline MoS2 and MoS2/hBN heterostructures. Two-laser Raman scattering thermometry was used combined with real time measurements of the absorbed laser power, which allowed us to determine the thermal conductivities without any assumptions. Measurements on MoS2 layers with thicknesses of 5 and 14 exhibit thermal conductivity in the range between 12 and 24 Wm-1K-1. Additionally, after determining the thermal conductivity of a selected MoS2 sample, an hBN flake was transferred onto it and the effective thermal conductivity of the heterostructure was subsequently measured. Remarkably, despite that the thickness of the hBN layer was less than a third of the thickness of the MoS2 layer, the heterostructure showed an almost eight-fold increase in the thermal conductivity, being able to dissipate more than 10 times the laser power without any visible sign of damage. These results are consistent with a high thermal interface conductance between MoS2 and hBN and an efficient in-plane heat spreading driven by hBN. Indeed, we estimate G 70 MWm-2K-1 which is significantly higher than previously reported values. Our work therefore demonstrates that the insertion of hBN layers in potential MoS2 based devices holds the promise for efficient thermal management.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Nanoporous graphene-based thin-film microelectrodes for in vivo high-resolution neural recording and stimulation

  • Viana, Damia|||0000-0001-8558-986X
  • Walston, Steven T.|||0000-0003-4567-8926
  • Masvidal Codina, Eduard|||0000-0002-9579-8603
  • Illa, Xavi|||0000-0002-3212-1128
  • Rodríguez-Meana, Bruno|||0000-0003-0052-7446
  • Del Valle, Jaume|||0000-0002-6703-8244
  • Hayward, Andrew
  • Dodd, Abbie
  • Loret, Thomas|||0000-0001-9171-9819
  • Prats-Alfonso, Elisabet
  • de la Oliva, Natalia|||0000-0002-1263-2705
  • Palma, Marie
  • Del Corro, Elena|||0000-0001-6452-9139
  • del Pilar Bernicola, María
  • Rodríguez-Lucas, Elisa
  • Gener, Thomas|||0000-0001-9209-9228
  • de la Cruz, Jose Manuel
  • Torres-Miranda, Miguel
  • Duvan, Fikret Taygun|||0000-0002-3377-9351
  • Ria, Nicola|||0000-0002-0082-0952
  • Sperling, Justin R.|||0000-0002-1708-2474
  • Martí-Sánchez, Sara|||0000-0003-4283-1489
  • Spadaro, Maria Chiara|||0000-0002-6540-0377
  • Hébert, Clément|||0000-0001-9667-033X
  • Savage, Sinead|||0000-0002-1761-9390
  • Arbiol i Cobos, Jordi|||0000-0002-0695-1726
  • Guimerà Brunet, Anton|||0000-0003-1768-3293
  • Puig, Maria Victoria|||0000-0002-1490-4153
  • Yvert, Blaise|||0000-0002-8850-7935
  • Navarro, X. (Xavier)|||0000-0001-9849-902X
  • Kostarelos, Kostas|||0000-0002-2224-6672
  • Garrido, Jose|||0000-0001-5621-1067
One of the critical factors determining the performance of neural interfaces is the electrode material used to establish electrical communication with the neural tissue, which needs to meet strict electrical, electrochemical, mechanical, biological and microfabrication compatibility requirements. This work presents a nanoporous graphene-based thin-film technology and its engineering to form flexible neural interfaces. The developed technology allows the fabrication of small microelectrodes (25 µm diameter) while achieving low impedance (∼25 kΩ) and high charge injection (3-5 mC cm ). In vivo brain recording performance assessed in rodents reveals high-fidelity recordings (signal-to-noise ratio >10 dB for local field potentials), while stimulation performance assessed with an intrafascicular implant demonstrates low current thresholds (<100 µA) and high selectivity (>0.8) for activating subsets of axons within the rat sciatic nerve innervating tibialis anterior and plantar interosseous muscles. Furthermore, the tissue biocompatibility of the devices was validated by chronic epicortical (12 week) and intraneural (8 week) implantation. This work describes a graphene-based thin-film microelectrode technology and demonstrates its potential for high-precision and high-resolution neural interfacing.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Single-Step Functionalization Strategy of Graphene Microtransistor Array with Chemically Modified Aptamers for Biosensing Applications

  • Brosel-Oliu, Sergi
  • Rius, Gemma|||0000-0003-0552-1043
  • Aviñó, Ana|||0000-0003-3047-738X
  • Nakatsuka, Nako
  • Illa, Xavi|||0000-0002-3212-1128
  • Del Corro, Elena|||0000-0001-6452-9139
  • Delgà-Fernández, Marta|||0000-0001-7434-8593
  • Masvidal Codina, Eduard|||0000-0002-9579-8603
  • Rodríguez, Natalia
  • Merino, Juan Pedro
  • Criado, Alejandro|||0000-0002-9732-513X
  • Prato, Maurizio|||0000-0002-8869-8612
  • Tkatchenko, Raphaela
  • Eritja, Ramon|||0000-0001-5383-9334
  • Godignon, Philippe
  • Garrido, Jose|||0000-0001-5621-1067
  • Villa, Rosa|||0000-0003-2735-3204
  • Guimerà, Anton
  • Prats-Alfonso, Elisabet
Graphene solution-gated field-effect transistors (gSGFETs) offer high potential for chemical and biochemical sensing applications. Among the current trends to improve this technology, the functionalization processes are gaining relevance for its crucial impact on biosensing performance. Previous efforts are focused on simplifying the attachment procedure from standard multi-step to single-step strategies, but they still suffer from overreaction, and impurity issues and are limited to a particular ligand. Herein, a novel strategy for single-step immobilization of chemically modified aptamers with fluorenylmethyl and acridine moieties, based on a straightforward synthetic route to overcome the aforementioned limitations is presented. This approach is benchmarked versus a standard multi-step strategy using thrombin as detection model. In order to assess the reliability of the functionalization strategies 48-gSGFETs arrays are employed to acquire large datasets with multiple replicas. Graphene surface characterization demonstrates robust and higher efficiency in the chemical coupling of the aptamers with the single-step strategy, while the electrical response evaluation validates the sensing capability, allowing to implement different alternatives for data analysis and reduce the sensing variability. In this work, a new tool capable of overcome the functionalization challenges of graphene surfaces is provided, paving the way toward the standardization of gSGFETs for biosensing purposes.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Ethanol Solvation of Polymer Residues in Graphene Solution-Gated Field Effect Transistors

  • Merino, Juan Pedro
  • Brosel-Oliu, Sergi
  • Rius, Gemma|||0000-0003-0552-1043
  • Illa, Xavi|||0000-0002-3212-1128
  • Vázque Sulleiro, Manuel|||0000-0002-9688-7771
  • Del Corro, Elena|||0000-0001-6452-9139
  • Masvidal Codina, Eduard|||0000-0002-9579-8603
  • Bonaccini Calia, Andrea|||0000-0002-7873-4296
  • Garrido, Jose|||0000-0001-5621-1067
  • Villa, Rosa|||0000-0003-2735-3204
  • Guimerà-Brunet, Anton
  • Prato, Maurizio|||0000-0002-8869-8612
  • Criado, Alejandro|||0000-0002-9732-513X
  • Prats Alfonso, Elisabet|||0000-0002-7320-1896
The persistence of photoresist residues from microfabrication procedures causes significant obstacles in the technological advancement of graphene-based electronic devices. These residues induce undesired chemical doping effects, diminish carrier mobility, and deteriorate the signal-to-noise ratio, making them critical in certain contexts, including sensing and electrical recording applications. In graphene solution-gated field-effect transistors (gSGFETs), the presence of polymer contaminants makes it difficult to perform precise electrical measurements, introducing response variability and calibration challenges. Given the absence of viable short to midterm alternatives to polymer-intensive microfabrication techniques, a postpatterning treatment involving THF and ethanol solvents was evaluated, with ethanol being the most effective, environmentally sustainable, and safe method for residue removal. Employing a comprehensive analysis with XPS, AFM, and Raman spectroscopy, together with electrical characterization, we investigated the influence of residual polymers on graphene surface properties and transistor functionality. Ethanol treatment exhibited a pronounced enhancement in gSGFET performance, as evidenced by a shift in the charge neutrality point and reduced dispersion. This systematic cleaning methodology holds the potential to improve the reproducibility and precision in the manufacturing of graphene devices. Particularly, by using ethanol for residue removal, we align our methodology with the principles of green chemistry, minimizing environmental impact while advancing diverse graphene technology applications.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

On the Electrochemical Activation of Nanoporous Reduced Graphene Oxide Electrodes Studied by In Situ/Operando Electrochemical Techniques

  • Bernicola, María del Pilar|||0000-0002-8124-2567
  • Lounasvuori, Mailis|||0000-0001-9738-4642
  • Padilla-Pantoja, Jessica|||0000-0002-7769-7753
  • Santiso, José|||0000-0003-4274-2101
  • Debiemme-Chouvy, Catherine
  • Perrot, Hubert|||0000-0002-3930-2968
  • Petit, Tristan|||0000-0002-6504-072X
  • Garrido, Jose|||0000-0001-5621-1067
  • Del Corro, Elena|||0000-0001-6452-9139
Due to the difficult access of the electrolyte into the nanoconfined space of nanoporous reduced graphene oxide (rGO) electrodes, achieving the optimal electrochemical performance of these devices becomes a challenge. In this work, the dynamics of interfacial-governed phenomena are investigated during a voltage-controlled electrochemical activation of nanoporous rGO electrodes that leads to an enhanced electrochemical performance in terms of areal capacitance and electrochemical impedance. In situ/operando characterization techniques are used to reveal the dynamics of the irreversible material changes introduced during the activation process, including ionic diffusion and water confinement within the nanopores, along with the reduction of oxygenated groups and the decrease of the rGO interlayer distance. Furthermore, operando techniques are used to uncover the origin of the complex polarization-dependent dynamic response of rGO electrodes. The study reveals that the reversible protonation/deprotonation of remaining functional groups and the cation electro-adsorption/desorption process in the graphene basal plane govern the pseudocapacitive performance of nanoporous rGO electrodes. This work brings new understanding of the complex interplay between surface chemistry, ion confinement, and desolvation processes occurring during electrochemical cycling in nanoporous rGO electrodes, offering new insights for designing high-performing electrodes based on nanoporous rGO.