Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Conjugation strategy shapes antitumor efficacy and enables dose-sparing in non-antibody protein nanoconjugates

  • Rueda, Ariana|||0000-0001-7588-9279
  • Garcia León, Annabel|||0000-0003-3007-9306
  • Arena, Lourdes Ailen|||0009-0006-1863-3895
  • Mendoza, Julian Ignacio|||0000-0002-1975-3606
  • Aviñó, Ana|||0000-0003-3047-738X
  • Fabrega, Carme|||0000-0003-3816-7634
  • Eritja, Ramon|||0000-0001-5383-9334
  • Paez, David|||0000-0002-5596-6588
  • Alba Castellón, Lorena|||0000-0003-3449-7820
  • Vázquez, Esther|||0000-0003-1052-0424
  • Villaverde, Antonio|||0000-0002-2615-4521
  • Mangues, Ramon|||0000-0003-2661-9525
  • Casanova Rigat, Isolda|||0000-0002-1196-4724
  • Unzueta Elorza, Ugutz|||0000-0001-5119-2266
Precision targeting is a hot topic in cancer nanomedicine, as conventional chemotherapies cause systemic toxicities, creating an urgent need for more selective treatments. Although antibody-drug conjugates (ADCs) are the current gold standard in targeted therapy, their clinical performance remains limited. As an alternative, we previously developed a multivalent protein nanocarrier (T22-GFP-H6) displaying the CXCR4-targeting peptide T22, which offers super-selective tumor accumulation driven by CXCR4 overexpression. This innovative nanovehicle showed favorable biodistribution for targeted delivery of antitumor drugs, including monomethyl auristatin E (MMAE), in a first-generation stochastic nanoconjugate format. However, unlike ADCs, where conjugation strategy is known to influence pharmacokinetics and efficacy, these parameters remain largely unexplored in non-antibody multivalent nanocarriers. Here, we evaluated the impact of precise payload accommodation using two site-specific strategies that attach a single MMAE molecule at distinct structural sites, and we compared them with first-generation nanoconjugates. The conjugation strategy substantially affected the biodistribution and antitumor efficacy, with a solvent-exposed cysteine-conjugation distal to the targeting ligand proving most effective. At equimolar nanocarrier dosing, this construct achieved tumor control similar to the stochastic conjugate in a disseminated hematologic malignancy despite an approximately 4-fold lower MMAE load (drug-to-protein ratio, DPR = 1 vs DPR ≈ 4). Moreover, at equimolar MMAE dosing, it clearly outperformed both the stochastic conjugate and the alternative site-directed design. These findings align with trends in advanced ADCs and provide practical design rules for rational, site-specific conjugation in next-generation protein-based nanomedicines aimed at enabling dose-sparing in oncology.
RUC. Repositorio da Universidade da Coruña
Publication Artículo científico (JournalArticle)

Single-Step Functionalization Strategy of Graphene Microtransistor Array with Chemically Modified Aptamers for Biosensing Applications

  • Brosel, Sergi
  • Rius, Gemma
  • Aviñó, Ana
  • Nako, Nakatsuka
  • Illa, Xavi
  • Corro, Elena del
  • Delgà-Fernández, Marta
  • Criado, Alejandro
  • Guimerà, Anton
  • Prats Alfonso, Elisabet
[Abstract]: Graphene solution-gated field-effect transistors (gSGFETs) offer high potential for chemical and biochemical sensing applications. Among the current trends to improve this technology, the functionalization processes are gaining relevance for its crucial impact on biosensing performance. Previous efforts are focused on simplifying the attachment procedure from standard multi-step to single-step strategies, but they still suffer from overreaction, and impurity issues and are limited to a particular ligand. Herein, a novel strategy for single-step immobilization of chemically modified aptamers with fluorenylmethyl and acridine moieties, based on a straightforward synthetic route to overcome the aforementioned limitations is presented. This approach is benchmarked versus a standard multi-step strategy using thrombin as detection model. In order to assess the reliability of the functionalization strategies 48-gSGFETs arrays are employed to acquire large datasets with multiple replicas. Graphene surface characterization demonstrates robust and higher efficiency in the chemical coupling of the aptamers with the single-step strategy, while the electrical response evaluation validates the sensing capability, allowing to implement different alternatives for data analysis and reduce the sensing variability. In this work, a new tool capable of overcome the functionalization challenges of graphene surfaces is provided, paving the way toward the standardization of gSGFETs for biosensing purposes., This work has received funding from the European Union's Horizon 2020 research and innovation programme under grant agreement no. 881603 (GrapheneCore3) and no. 785219 (GrapheneCore2). M. P. is AXA Professor and is supported by the European Research Council (ERC-AdG-2019, no. 885323), the Agencia Estatal de Investigación-AEI (“Proyectos I+D+i 2019-Modalidad Retos Investigación”, no. PID2019-108523RB-I00), by grant PRE2020-095099 funded by MCIN/AEI/10.13039/501100011033 and by “ESF Investing in your future.” Part of this work has made use of the Spanish ICTS Network MICRONANOFABS, partially supported by MICINN and the ICTS NANBIOSIS, more specifically by the Micro-NanoTechnology Unit U8 of the CIBER-BBN. This project was also funded by the Generalitat de Catalunya (2021SGR00495), by the Spanish Ministerio de Ciencia e Innovación (PID2021-126117NA-I00), by “ERDF A way of making Europe”, and by CIBER-BBN (CB06/01/0049). X. I., R. V., A. G. and E. P.-A. thank the financial support provided by CIBER-BBN and the Instituto de Salud Carlos III with assistance from the European Regional Development. A. C. acknowledges financial support by Grant ED431H 2020/17 funded by Xunta de Galicia, and by Grant RYC2020-030183-I funded by MCIN/AEI/10.13039/501100011033 and “ESF Investing in your future”., Generalitat de Catalunya; 2021SGR00495
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Single-Step Functionalization Strategy of Graphene Microtransistor Array with Chemically Modified Aptamers for Biosensing Applications

  • Brosel-Oliu, Sergi
  • Rius, Gemma|||0000-0003-0552-1043
  • Aviñó, Ana|||0000-0003-3047-738X
  • Nakatsuka, Nako
  • Illa, Xavi|||0000-0002-3212-1128
  • Del Corro, Elena|||0000-0001-6452-9139
  • Delgà-Fernández, Marta|||0000-0001-7434-8593
  • Masvidal Codina, Eduard|||0000-0002-9579-8603
  • Rodríguez, Natalia
  • Merino, Juan Pedro
  • Criado, Alejandro|||0000-0002-9732-513X
  • Prato, Maurizio|||0000-0002-8869-8612
  • Tkatchenko, Raphaela
  • Eritja, Ramon|||0000-0001-5383-9334
  • Godignon, Philippe
  • Garrido, Jose|||0000-0001-5621-1067
  • Villa, Rosa|||0000-0003-2735-3204
  • Guimerà, Anton
  • Prats-Alfonso, Elisabet
Graphene solution-gated field-effect transistors (gSGFETs) offer high potential for chemical and biochemical sensing applications. Among the current trends to improve this technology, the functionalization processes are gaining relevance for its crucial impact on biosensing performance. Previous efforts are focused on simplifying the attachment procedure from standard multi-step to single-step strategies, but they still suffer from overreaction, and impurity issues and are limited to a particular ligand. Herein, a novel strategy for single-step immobilization of chemically modified aptamers with fluorenylmethyl and acridine moieties, based on a straightforward synthetic route to overcome the aforementioned limitations is presented. This approach is benchmarked versus a standard multi-step strategy using thrombin as detection model. In order to assess the reliability of the functionalization strategies 48-gSGFETs arrays are employed to acquire large datasets with multiple replicas. Graphene surface characterization demonstrates robust and higher efficiency in the chemical coupling of the aptamers with the single-step strategy, while the electrical response evaluation validates the sensing capability, allowing to implement different alternatives for data analysis and reduce the sensing variability. In this work, a new tool capable of overcome the functionalization challenges of graphene surfaces is provided, paving the way toward the standardization of gSGFETs for biosensing purposes.