Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Graphene-based microelectrodes with bidirectional functionality for next-generation retinal electronic interfaces

  • Duvan, Fikret Taygun|||0000-0002-3377-9351
  • Cunquero, Marina|||0000-0001-8093-8186
  • Masvidal Codina, Eduard|||0000-0002-9579-8603
  • Walston, Steven T.|||0000-0003-4567-8926
  • Marsal, Maria|||0000-0001-9678-8717
  • de la Cruz, Jose Manuel
  • Viana, Damia|||0000-0001-8558-986X
  • Nguyen, Diep
  • Dégardin, Julie
  • Illa, Xavi|||0000-0002-3212-1128
  • Zhang, Julie Meng|||0000-0001-5985-3815
  • Bernicola, María del Pilar|||0000-0002-8124-2567
  • Macias Montero, Jose Gabriel
  • Puigdengoles, Carles|||0000-0002-1372-5452
  • Castro-Olvera, Gustavo|||0000-0001-9843-3581
  • Del Corro, Elena|||0000-0001-6452-9139
  • Dokos, Socrates
  • Chmeissani, Mokhtar|||0000-0002-2287-4791
  • Loza-Alvarez, Pablo|||0000-0002-3129-1213
  • Picaud, Serge|||0000-0002-0548-5145
  • Garrido, Jose|||0000-0001-5621-1067
Neuroelectronic prostheses are being developed for restoring vision at the retinal level in patients who have lost their sight due to photoreceptor loss. The core component of these devices is the electrode array, which enables interfacing with retinal neurons. Generating the perception of meaningful images requires high-density microelectrode arrays (MEAs) capable of precisely activating targeted retinal neurons. Achieving this precision necessitates the downscaling of electrodes to micrometer dimensions. However, miniaturization increases electrode impedance, which poses challenges by limiting the amount of current that can be delivered, thereby impairing the electrode's capability for effective neural modulation. Additionally, it elevates noise levels, reducing the signal quality of the recorded neural activity. This report focuses on evaluating reduced graphene oxide (rGO) based devices for interfacing with the retina, showcasing their potential in vision restoration. Our findings reveal low impedance and high charge injection limit for microscale rGO electrodes, confirming their suitability for developing next-generation high-density retinal devices. We successfully demonstrated bidirectional interfacing with cell cultures and explanted retinal tissue, enabling the identification and modulation of multiple cells' activity. Additionally, calcium imaging allowed real-time monitoring of retinal cell dynamics, demonstrating a significant reduction in activated areas with small-sized electrodes. Overall, this study lays the groundwork for developing advanced rGO-based MEAs for high-acuity visual prostheses.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Concurrent functional ultrasound imaging with graphene-based DC-coupled electrophysiology as a platform to study slow brain signals and cerebral blood flow under control and pathophysiological brain states

  • Zhang, Julie Meng|||0000-0001-5985-3815
  • Masvidal Codina, Eduard|||0000-0002-9579-8603
  • Nguyen, Diep
  • Illa, Xavi|||0000-0002-3212-1128
  • Dégardin, Julie
  • Goulet, Ruben
  • Prats-Alfonso, Elisabet
  • Matsoukis, Stratis
  • Guger, Christoph
  • Garrido, Jose Antonio
  • Picaud, Serge|||0000-0002-0548-5145
  • Guimerà-Brunet, Anton
  • Wykes, Robert C|||0000-0002-6141-6822
Current methodology used to investigate how shifts in brain states associated with regional cerebral blood volume (CBV) change in deep brain areas, are limited by either the spatiotemporal resolution of the CBV techniques, and/or compatibility with electrophysiological recordings; particularly in relation to spontaneous brain activity and the study of individual events. Additionally, infraslow brain signals (<0.1 Hz), including spreading depolarisations, DC-shifts and infraslow oscillations (ISO), are poorly captured by traditional AC-coupled electrographic recordings; yet these very slow brain signals can profoundly change CBV. To gain an improved understanding of how infraslow brain signals couple to CBV we present a new method for concurrent CBV with wide bandwidth electrophysiological mapping using simultaneous functional ultrasound imaging (fUS) and graphene-based field effect transistor (gFET) DC-coupled electrophysiological acquisitions. To validate the feasibility of this methodology visually-evoked neurovascular coupling (NVC) responses were examined. gFET recordings are not affected by concurrent fUS imaging, and epidural placement of gFET arrays within the imaging window did not deteriorate fUS signal quality. To examine directly the impact of infra-slow potential shifts on CBV, cortical spreading depolarisations (CSDs) were induced. A biphasic pattern of decreased, followed by increased CBV, propagating throughout the ipsilateral cortex, and a delayed decrease in deeper subcortical brain regions was observed. In a model of acute seizures, CBV oscillations were observed prior to seizure initiation. Individual seizures occurred on the rising phase of both infraslow brain signal and CBV oscillations. When seizures co-occurred with CSDs, CBV responses were larger in amplitude, with delayed CBV decreases in subcortical structures. Overall, our data demonstrate that gFETs are highly compatible with fUS and allow concurrent examination of wide bandwidth electrophysiology and CBV. This graphene-enabled technological advance has the potential to improve our understanding of how infraslow brain signals relate to CBV changes in control and pathological brain states.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Neuronal Waveform Classification in Multielectrode Recordings Using Machine Learning Techniques and Multidimensional Analysis

  • López-Peco, Rocio
  • Val-Calvo, Mikel
  • Soto-Sánchez, Cristina
  • Villamarin-Ortiz, Adrian
  • Ruiz-Boix, Gloria
  • Ferrández-Vicente, Jose Manuel
  • Fernandez, Eduardo
[EN] Extracellular recordings of neuronal spikes are crucial for studying brain activity. These signals are typically classified based on firing patterns and waveform shape, particularly trough-to-peak duration. While useful, this method oversimplifies the diversity of cortical neurons and discharge patterns. Recent advances in recording and analysis techniques allow for more precise waveform classification, though the main criteria remain waveform features. We aim to develop an automatic spike waveform classifier using advanced machine learning techniques selected from a range of candidate methods based on their optimized performance, such as Uniform Manifold Approximation and Projection (UMAP), Gaussian Mixture Model (GMM), and Random Forest (RF). The classifier is part of the working progress of a preprocessing pipeline previously developed. For the classifying step, we use all voltage samples that define each waveform, enabling a multi-dimensional analysis. To evaluate our approach, RF model was trained and tested on a subset of electrophysiological recordings from the human visual cortex achieving high F1-scores. The comparison of the classified neurons was carried out between our method and a waveform analysis toolbox described in the literature. Our method improves the characterization of the clusters of waveforms based on statistical measurements that found a third group while the accepted method categorizes just broad and narrow waveforms, labeling some as unclassifiable., This work was supported in part by grants PDC2022-133952-100 and PID2022-141606OB-I00 from the Spanish Ministerio de Ciencia, Innovacion y Universidades, by grant CIPROM/2023/25 from the Generalitat Valenciana, by the European Union's Horizon 2020 Research and Innovation Programme under Grant Agreements No. 899287 (NeuraViPeR) and 861423 (enTRAIN Vision), by Horizon Europe MSCA SE EPISTEAM grant 101129655, and by Programa Iberoamericano de Ciencia y Tecnologia para el Desarrollo (CYTED) (through Red [225RT0169]). The authors also acknowledge the support and collaboration with Instead Technologies for helping people S.L, as this research is conducted in partnership with them under the context of a collaborative doctoral agreement.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Graphene-based microelectrodes with bidirectional functionality for next-generation retinal electronic interfaces

  • Duvan, F. Taygun
  • Cunquero, Marina
  • Masvidal Codina, Eduard
  • Walston, Steven T.
  • Marsal, María
  • Cruz, Jose Manuel de la
  • Viana, Damià
  • Nguyen, Diep
  • Degardin, Julie
  • Illa, Xavi
  • Zhang, Julie M.
  • Bernicola, María del Pilar
  • Macías-Montero, José Gabriel
  • Puigdengoles, Carles
  • Castro-Olvera, Gustavo
  • Del Corro, Elena
  • Dokos, Socrates
  • Chmeissani, Mokhtar
  • Loza-Álvarez, Pablo
  • Picaud, Serge
  • Garrido, Jose A.
This article is part of the themed collection: Graphene and 2D Materials in Healthcare., Neuroelectronic prostheses are being developed for restoring vision at the retinal level in patients who have lost their sight due to photoreceptor loss. The core component of these devices is the electrode array, which enables interfacing with retinal neurons. Generating the perception of meaningful images requires high-density microelectrode arrays (MEAs) capable of precisely activating targeted retinal neurons. Achieving this precision necessitates the downscaling of electrodes to micrometer dimensions. However, miniaturization increases electrode impedance, which poses challenges by limiting the amount of current that can be delivered, thereby impairing the electrode's capability for effective neural modulation. Additionally, it elevates noise levels, reducing the signal quality of the recorded neural activity. This report focuses on evaluating reduced graphene oxide (rGO) based devices for interfacing with the retina, showcasing their potential in vision restoration. Our findings reveal low impedance and high charge injection limit for microscale rGO electrodes, confirming their suitability for developing next-generation high-density retinal devices. We successfully demonstrated bidirectional interfacing with cell cultures and explanted retinal tissue, enabling the identification and modulation of multiple cells' activity. Additionally, calcium imaging allowed real-time monitoring of retinal cell dynamics, demonstrating a significant reduction in activated areas with small-sized electrodes. Overall, this study lays the groundwork for developing advanced rGO-based MEAs for high-acuity visual prostheses., The project leading to these results have received funding from “la Caixa” Foundation (ID 100010434), under the agreement LCF/PR/HR19/52160003 (i-VISION), European Unions Horizon 2020 research and innovation programme under grant agreement no. 881603 (Graphene flagship Core3), and French state funds managed by the Agence Nationale de la Recherche (ANR) within Programme Investissements dAvenir, Laboratoire dExcellence (LABEX) LIFESENSES (ANR-10-LABX-0065) and Institut Hospitalo-Universitaire FOReSIGHT (ANR-18-IAHU-0001). We also acknowledge funding from the Generalitat de Catalunya (2021SGR001534). E. D. C. thanks the Ayuda RYC2019-027879-I founded by MCIU/AEI/10.13039/501100011033 and by El FSE invierte en tu futuro. E. M. C. acknowledges Ayuda FJC2021-046601-I financiada por MCIU/AEI/10.13039/501100011033 y por la Unión Europea NextGenerationEU/PRTR. This research was funded by the Spanish Ministerio de Ciencia e Innovación (PID2020-113663RB-I00) founded by (MCIU/AEI/10.13039/501100011033) and by “ERDF A way of making Europe”. The ICN2 has been supported by the Severo Ochoa Centres of Excellence programme [SEV-2017-0706] and is currently supported by the Severo Ochoa Centres of Excellence programme, Grant CEX2021-001214-S, both funded by MCIN and MCIU/AEI/10.13039.501100011033. This project has also received funding from the European Unions Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement no. 861423 (enTRAIN Vision). Part of this work was performed at the Spanish ICTS Network MICRONANOFABS partially supported by MICINN, and the ICTS ‘NANBIOSIS’, more specifically by the Micro-NanoTechnology Unit of the CIBER in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN) at the IMB-CNM. DN has received funding from the doctoral school of Cerveau, cognition, comportement (3C) at Sorbonne Université., With funding from the Spanish government through the "Severo Ochoa Centre of Excellence" accreditation (CEX2021-001214-S)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Concurrent functional ultrasound imaging with graphene-based DC-coupled electrophysiology as a platform to study slow brain signals and cerebral blood flow under control and pathophysiological brain states

  • Zhang, Julie M.
  • Masvidal Codina, Eduard
  • Nguyen, Diep
  • Illa, Xavi
  • Degardin, Julie
  • Goulet, Ruben
  • Prats Alfonso, Elisabet
  • Matsoukis, Stratis
  • Guger, Christoph
  • Garrido, Jose A.
  • Picaud, Serge
  • Guimerà-Brunet, Anton
  • Wykes, Rob C.
Current methodology used to investigate how shifts in brain states associated with regional cerebral blood volume (CBV) change in deep brain areas, are limited by either the spatiotemporal resolution of the CBV techniques, and/or compatibility with electrophysiological recordings; particularly in relation to spontaneous brain activity and the study of individual events. Additionally, infraslow brain signals (<0.1 Hz), including spreading depolarisations, DC-shifts and infraslow oscillations (ISO), are poorly captured by traditional AC-coupled electrographic recordings; yet these very slow brain signals can profoundly change CBV. To gain an improved understanding of how infraslow brain signals couple to CBV we present a new method for concurrent CBV with wide bandwidth electrophysiological mapping using simultaneous functional ultrasound imaging (fUS) and graphene-based field effect transistor (gFET) DC-coupled electrophysiological acquisitions. To validate the feasibility of this methodology visually-evoked neurovascular coupling (NVC) responses were examined. gFET recordings are not affected by concurrent fUS imaging, and epidural placement of gFET arrays within the imaging window did not deteriorate fUS signal quality. To examine directly the impact of infra-slow potential shifts on CBV, cortical spreading depolarisations (CSDs) were induced. A biphasic pattern of decreased, followed by increased CBV, propagating throughout the ipsilateral cortex, and a delayed decrease in deeper subcortical brain regions was observed. In a model of acute seizures, CBV oscillations were observed prior to seizure initiation. Individual seizures occurred on the rising phase of both infraslow brain signal and CBV oscillations. When seizures co-occurred with CSDs, CBV responses were larger in amplitude, with delayed CBV decreases in subcortical structures. Overall, our data demonstrate that gFETs are highly compatible with fUS and allow concurrent examination of wide bandwidth electrophysiology and CBV. This graphene-enabled technological advance has the potential to improve our understanding of how infraslow brain signals relate to CBV changes in control and pathological brain states., This research was funded by the European Union's Horizon 2020 research and innovation programme under grant agreement no. 881603 (Graphene flagship Core 3). This project has also received funding from the European Union's Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement no. 861423 (enTRAIN Vision). We acknowledge the LabEx LIFESENSES (ANR-10-LABX-65) and IHU FOReSIGHT (ANR-18-IAHU-01). RW holds a Senior Research Fellowship funded by the Worshipful Company of Pewterers. ICN2 is supported by the Severo Ochoa Centres of Excellence programme (Grant CEX2021-001214-S), funded by MCIN/AEI/10.13039.501100011033, and by the CERCA Programme of Generalitat de Catalunya. E. M. C. acknowledges grant FJC2021-046601-I funded by Agencia Estatal de Investigación of Spain and the European Union NextGenerationEU/PRTR. This work has made use of the Spanish ICTS Network MICRONANOFABS, partially supported by MICINN and the ICTS NANBIOSIS, specifically by the Micro-NanoTechnology Unit U8 of the CIBER-BBN. This research has been also supported by funding from the Generalitat de Catalunya (2021SGR00495), MCIN/AEI/10.13039/501100011033 and “ERDF A way of making Europe” (grant PID2021-126117NA-I00), and the “European Union NextGenerationEU/PRTR”, (grant PLEC2022-009232), and CIBER-Consorcio Centro de Investigación Biomédica en Red-(CB06/01/0049), Instituto de Salud Carlos III, Ministerio de Ciencia e Innovación., With funding from the Spanish government through the "Severo Ochoa Centre of Excelence" accreditation (CEX2021-001214-S), Peer reviewed