Skip to main content

COMPUTATIONAL BIOLOGY AND BIOMEDICAL SYSTEMS

PRE2018-084062

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de Promoción del Talento y su Empleabilidad en I+D+i
Subprogram Subprograma Estatal de Formación
Call Contratos Predoctorales
Call year 2018
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSITAT POMPEU FABRA CCT

Resultados relacionados

Resultados totales (Incluyendo duplicados): 10
Encontrada(s) 1 página(s)

Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Deep learning framework for real-time estimation of in-silico thrombotic risk indices in the left atrial appendage

  • Morales Ferez, Xabier
  • Mill, Jordi
  • Juhl, Kristine Aavild
  • Acebes Pinilla, César
  • Iriart, Xavier
  • Legghe, Benoit
  • Cochet, Hubert
  • De Backer, Ole
  • Paulsen, Rasmus R.
  • Camara, Oscar
Patient-specific computational fluid dynamics (CFD) simulations can provide invaluable insight into the interaction of left atrial appendage (LAA) morphology, hemodynamics, and the formation of thrombi in atrial fibrillation (AF) patients. Nonetheless, CFD solvers are notoriously time-consuming and computationally demanding, which has sparked an ever-growing body of literature aiming to develop surrogate models of fluid simulations based on neural networks. The present study aims at developing a deep learning (DL) framework capable of predicting the endothelial cell activation potential (ECAP), an in-silico index linked to the risk of thrombosis, typically derived from CFD simulations, solely from the patient-specific LAA morphology. To this end, a set of popular DL approaches were evaluated, including fully connected networks (FCN), convolutional neural networks (CNN), and geometric deep learning. While the latter directly operated over non-Euclidean domains, the FCN and CNN approaches required previous registration or 2D mapping of the input LAA mesh. First, the superior performance of the graph-based DL model was demonstrated in a dataset consisting of 256 synthetic and real LAA, where CFD simulations with simplified boundary conditions were run. Subsequently, the adaptability of the geometric DL model was further proven in a more realistic dataset of 114 cases, which included the complete patient-specific LA and CFD simulations with more complex boundary conditions. The resulting DL framework successfully predicted the overall distribution of the ECAP in both datasets, based solely on anatomical features, while reducing computational times by orders of magnitude compared to conventional CFD solvers., This work was supported by the Agency for Management of University and Research Grants of the Generalitat de Catalunya under the Grants for the Contracting of New Research Staff Programme—FI (2020-FI-B-00690) and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502) and the Retos Investigación project (RTI2018-101193-B-I00). Additionally, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020; grant agreement No. 101016496).
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Towards assisted electrocardiogram interpretation using an AI-enabled Augmented Reality headset

  • Lampreave, Paula
  • Jimenez-Perez, Guillermo
  • Sanz-Pérez, Isidro
  • Gomez, Alberto
  • Camara, Oscar
The interpretation of electrocardiograms (ECGs) is key for the diagnosis and monitoring of cardiovascular health. Despite the progressive digital transformation in healthcare, it is still common for clinicians to analyse ECG printed on paper. Although some systems provide signal processing-based ECG classification, clinicians often find it unreliable. Artificial Intelligence (AI) techniques are becoming state-of-the-art for ECG processing but the lack of digitised ECG has hampered the clinical translation of these techniques. Concurrently, we are living a rise in augmented reality (AR) technologies, with an increasing availability of devices. In this work, we present an automatic digitisation and assisted interpretation of ECG based on an AI-enabled Augmented Reality headset. The AR headset is used to acquire an image of the printed ECG, from which the digitised ECG signal is extracted. Afterwards, the digitised ECG is introduced into a Deep Learning (DL) algorithm pre-trained on a public database of 12-lead ECG recordings. The output of the DL algorithm classifies the ECG signal onto different cardiomyopathy categories, which is then visualized back in the AR headset. Preliminary classification results on simulated ECG images (96.5% of accuracy) confirm the potential of the developed approach to contribute on the digital transformation of ECG processing., This work was supported by the Ministerio de Ciencia, Innovación y Universidades under the Retos I+D Programme (RTI2018-101193-B-I00), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502) and the Ministerio de Economíay Competitividad under the Programme for the Formation of Doctors (PRE2018-084062). Alberto Gomez acknowl-edges financial support from the Department of Health via the National Institute for Health Research (NIHR) comprehensive Biomedical Research Centre award to Guy’s and St Thomas’ NHS Foundation Trust in partnership with King's College London and King’s College Hospital NHS Foundation Trust.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Joint analysis of morphological parameters and in silico haemodynamics of the left atrial appendage for thrombogenic risk assessment

  • Pons Vidal, Maria Isabel
  • Mill, Jordi
  • Fernandez-Quilez, Álvaro
  • Olivares, Andy L.
  • Silva, Etelvino
  • De Potter, Tom
  • Camara, Oscar
Background. Atrial fibrillation (AF) is considered the most common human arrhythmia. In nonvalvular AF, around 99% of thrombi are formed in the left atrial appendage (LAA). Nevertheless, there is not a consensus in the community about the relevant factors to stratify the AF population according to thrombogenic risk. Objective. To demonstrate the need for combining left atrial morphological and haemodynamics indices to improve the thrombogenic risk assessment in nonvalvular AF patients. Methods. A cohort of 71 nonvalvular AF patients was analysed. Statistical analysis, regression models, and random forests were used to analyse the differences between morphological and haemodynamics parameters, extracted from computational simulations built on 3D rotational angiography images, between patients with and without transient ischemic attack (TIA) or cerebrovascular accident (CVA). Results. The analysis showed that models composed of both morphological and haemodynamic factors were better predictors of TIA/CVA compared with models based on either morphological or haemodynamic factors separately. Maximum ostium diameter, length of the centreline, blood flow velocity within the LAA, oscillatory shear index, and time average wall shear stress parameters were found to be key risk factors for TIA/CVA prediction. In addition, TIA/CVA patients presented more flow stagnation within the LAA. Conclusion. Thrombus formation in the LAA is the result of multiple factors. Analyses based only on morphological or haemodynamic parameters are not precise enough to predict such a phenomenon, as demonstrated in our results; a better patient stratification can be obtained by jointly analysing morphological and haemodynamic features., This work was supported by the Spanish Ministry of Science, Innovation and Universities under the Retos I+D Programme (RTI2018-101193-B-I00), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502), the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), and MINECO (RYC-2015-18888).
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Domain expert evaluation of advanced visual computing solutions and 3D printing for the planning of the left atrial appendage occluder interventions

  • Mill, Jordi
  • Montoliu, Helena
  • Moustafa, Abdel-Hakim
  • Olivares, Andy L.
  • Albors, Carlos
  • Aguado, Ainhoa M.
  • Medina, Elodie
  • Ceresa, Mario
  • Freixa, Xavier
  • Arzamendi, Dabit
  • Cochet, Hubert
  • Camara, Oscar
Advanced visual computing solutions and three-dimensional (3D) printing are moving from engineering to clinical pipelines for training, planning, and guidance of complex interventions. 3D imaging and rendering, virtual reality (VR), and in-silico simulations, as well as 3D printing technologies provide complementary information to better understand the structure and function of the organs, thereby improving and personalizing clinical decisions. In this study, we evaluated several advanced visual computing solutions, such as web-based 3D imaging visualization, VR, and computational fluid simulations, together with 3D printing, for the planning of the left atrial appendage occluder (LAAO) device implantations. Six cardiologists tested different technologies in pre-operative data of five patients to identify the usability, limitations, and requirements for the clinical translation of each technology through a qualitative questionnaire. The obtained results demonstrate the potential impact of advanced visual computing solutions and 3D printing to improve the planning of LAAO interventions as well as the need for their integration into a single workflow to be used in a clinical environment., This work was supported by the Spanish Ministry of Science, Innovation and Universities under the Retos I+D Programme (RTI2018-101193-B-I00), the Maria de Maeztu Units of Excellence Programme (MDM 2015-0502), and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062). In addition, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020; grant agreement No. 101016496).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Domain expert evaluation of advanced visual computing solutions and 3D printing for the planning of the left atrial appendage occluder interventions

  • Mill, Jordi
  • Montoliu, Helena
  • Moustafa, Abdel-Hakim
  • Olivares, Andy L.
  • Albors, Carlos
  • Aguado, Ainhoa M.
  • Medina, Elodie
  • Ceresa, Mario
  • Freixa, Xavier
  • Arzamendi, Dabit
  • Cochet, Hubert
  • Camara, Oscar
Advanced visual computing solutions and three-dimensional (3D) printing are moving from engineering to clinical pipelines for training, planning, and guidance of complex interventions. 3D imaging and rendering, virtual reality (VR), and in-silico simulations, as well as 3D printing technologies provide complementary information to better understand the structure and function of the organs, thereby improving and personalizing clinical decisions. In this study, we evaluated several advanced visual computing solutions, such as web-based 3D imaging visualization, VR, and computational fluid simulations, together with 3D printing, for the planning of the left atrial appendage occluder (LAAO) device implantations. Six cardiologists tested different technologies in pre-operative data of five patients to identify the usability, limitations, and requirements for the clinical translation of each technology through a qualitative questionnaire. The obtained results demonstrate the potential impact of advanced visual computing solutions and 3D printing to improve the planning of LAAO interventions as well as the need for their integration into a single workflow to be used in a clinical environment., This work was supported by the Spanish Ministry of Science, Innovation and Universities under the Retos I+D Programme (RTI2018-101193-B-I00), the Maria de Maeztu Units of Excellence Programme (MDM 2015-0502), and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062). In addition, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020; grant agreement No. 101016496).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Deep learning framework for real-time estimation of in-silico thrombotic risk indices in the left atrial appendage

  • Morales Ferez, Xabier
  • Mill, Jordi
  • Juhl, Kristine Aavild
  • Acebes Pinilla, César
  • Iriart, Xavier
  • Legghe, Benoit
  • Cochet, Hubert
  • De Backer, Ole
  • Paulsen, Rasmus R.
  • Camara, Oscar
Patient-specific computational fluid dynamics (CFD) simulations can provide invaluable insight into the interaction of left atrial appendage (LAA) morphology, hemodynamics, and the formation of thrombi in atrial fibrillation (AF) patients. Nonetheless, CFD solvers are notoriously time-consuming and computationally demanding, which has sparked an ever-growing body of literature aiming to develop surrogate models of fluid simulations based on neural networks. The present study aims at developing a deep learning (DL) framework capable of predicting the endothelial cell activation potential (ECAP), an in-silico index linked to the risk of thrombosis, typically derived from CFD simulations, solely from the patient-specific LAA morphology. To this end, a set of popular DL approaches were evaluated, including fully connected networks (FCN), convolutional neural networks (CNN), and geometric deep learning. While the latter directly operated over non-Euclidean domains, the FCN and CNN approaches required previous registration or 2D mapping of the input LAA mesh. First, the superior performance of the graph-based DL model was demonstrated in a dataset consisting of 256 synthetic and real LAA, where CFD simulations with simplified boundary conditions were run. Subsequently, the adaptability of the geometric DL model was further proven in a more realistic dataset of 114 cases, which included the complete patient-specific LA and CFD simulations with more complex boundary conditions. The resulting DL framework successfully predicted the overall distribution of the ECAP in both datasets, based solely on anatomical features, while reducing computational times by orders of magnitude compared to conventional CFD solvers., This work was supported by the Agency for Management of University and Research Grants of the Generalitat de Catalunya under the Grants for the Contracting of New Research Staff Programme—FI (2020-FI-B-00690) and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502) and the Retos Investigación project (RTI2018-101193-B-I00). Additionally, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020; grant agreement No. 101016496).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Towards assisted electrocardiogram interpretation using an AI-enabled Augmented Reality headset

  • Lampreave, Paula
  • Jimenez-Perez, Guillermo
  • Sanz-Pérez, Isidro
  • Gomez, Alberto
  • Camara, Oscar
The interpretation of electrocardiograms (ECGs) is key for the diagnosis and monitoring of cardiovascular health. Despite the progressive digital transformation in healthcare, it is still common for clinicians to analyse ECG printed on paper. Although some systems provide signal processing-based ECG classification, clinicians often find it unreliable. Artificial Intelligence (AI) techniques are becoming state-of-the-art for ECG processing but the lack of digitised ECG has hampered the clinical translation of these techniques. Concurrently, we are living a rise in augmented reality (AR) technologies, with an increasing availability of devices. In this work, we present an automatic digitisation and assisted interpretation of ECG based on an AI-enabled Augmented Reality headset. The AR headset is used to acquire an image of the printed ECG, from which the digitised ECG signal is extracted. Afterwards, the digitised ECG is introduced into a Deep Learning (DL) algorithm pre-trained on a public database of 12-lead ECG recordings. The output of the DL algorithm classifies the ECG signal onto different cardiomyopathy categories, which is then visualized back in the AR headset. Preliminary classification results on simulated ECG images (96.5% of accuracy) confirm the potential of the developed approach to contribute on the digital transformation of ECG processing., This work was supported by the Ministerio de Ciencia, Innovación y Universidades under the Retos I+D Programme (RTI2018-101193-B-I00), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502) and the Ministerio de Economíay Competitividad under the Programme for the Formation of Doctors (PRE2018-084062). Alberto Gomez acknowl-edges financial support from the Department of Health via the National Institute for Health Research (NIHR) comprehensive Biomedical Research Centre award to Guy’s and St Thomas’ NHS Foundation Trust in partnership with King's College London and King’s College Hospital NHS Foundation Trust.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Joint analysis of morphological parameters and in silico haemodynamics of the left atrial appendage for thrombogenic risk assessment

  • Pons Vidal, Maria Isabel
  • Mill, Jordi
  • Fernandez-Quilez, Álvaro
  • Olivares, Andy L.
  • Silva, Etelvino
  • De Potter, Tom
  • Camara, Oscar
Background. Atrial fibrillation (AF) is considered the most common human arrhythmia. In nonvalvular AF, around 99% of thrombi are formed in the left atrial appendage (LAA). Nevertheless, there is not a consensus in the community about the relevant factors to stratify the AF population according to thrombogenic risk. Objective. To demonstrate the need for combining left atrial morphological and haemodynamics indices to improve the thrombogenic risk assessment in nonvalvular AF patients. Methods. A cohort of 71 nonvalvular AF patients was analysed. Statistical analysis, regression models, and random forests were used to analyse the differences between morphological and haemodynamics parameters, extracted from computational simulations built on 3D rotational angiography images, between patients with and without transient ischemic attack (TIA) or cerebrovascular accident (CVA). Results. The analysis showed that models composed of both morphological and haemodynamic factors were better predictors of TIA/CVA compared with models based on either morphological or haemodynamic factors separately. Maximum ostium diameter, length of the centreline, blood flow velocity within the LAA, oscillatory shear index, and time average wall shear stress parameters were found to be key risk factors for TIA/CVA prediction. In addition, TIA/CVA patients presented more flow stagnation within the LAA. Conclusion. Thrombus formation in the LAA is the result of multiple factors. Analyses based only on morphological or haemodynamic parameters are not precise enough to predict such a phenomenon, as demonstrated in our results; a better patient stratification can be obtained by jointly analysing morphological and haemodynamic features., This work was supported by the Spanish Ministry of Science, Innovation and Universities under the Retos I+D Programme (RTI2018-101193-B-I00), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502), the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), and MINECO (RYC-2015-18888).
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Sensitivity analysis of in silico fluid simulations to predict thrombus formation after left atrial appendage occlusion

  • Mill, Jordi|||0000-0003-0087-7489
  • Agudelo Montañez, Victor Hugo
  • Olivares, Andy Luis|||0000-0002-7284-0696
  • Pons, Maria Isabel
  • Silva, Etelvino
  • Nuñez-Garcia, Marta|||0000-0001-9349-3059
  • Morales Ferez, Xabier|||0000-0003-1349-2457
  • Arzamendi, Dabit|||0000-0001-7543-5867
  • Freixa, Xavier|||0000-0002-3203-9060
  • Noailly, Jérôme
  • Camara, Oscar|||0000-0002-5125-6132
Atrial fibrillation (AF) is nowadays the most common human arrhythmia and it is consid-ered a marker of an increased risk of embolic stroke. It is known that 99% of AF-related thrombi are generated in the left atrial appendage (LAA), an anatomical structure located within the left atrium (LA). Left atrial appendage occlusion (LAAO) has become a good alternative for nonvalvular AF patients with contraindications to anticoagulants. However, there is a non-negligible number of device-related thrombus (DRT) events, created next to the device surface. In silico fluid simulations can be a powerful tool to better understand the relation between LA anatomy, haemodynamics, and the process of thrombus formation. Despite the increasing literature in LA fluid modelling, a consensus has not been reached yet in the community on the optimal modelling choices and boundary conditions for generating realistic simulations. In this line, we have performed a sensitivity analysis of several boundary conditions scenarios, varying inlet/outlet and LA wall movement configurations, using patient-specific imaging data of six LAAO patients (three of them with DRT at follow-up). Mesh and cardiac cycle convergence were also analysed. The boundary conditions scenario that better predicted DRT cases had echocardiography-based velocities at the mitral valve outlet, a generic pressure wave from an AF patient at the pulmonary vein inlets, and a dynamic mesh approach for LA wall deformation, emphasizing the need for patient-specific data for realistic simulations. The obtained promising results need to be further validated with larger cohorts, ideally with ground truth data, but they already offer unique insights on thrombogenic risk in the left atria.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Domain expert evaluation of advanced visual computing solutions and 3D printing for the planning of the left atrial appendage occluder interventions

  • Mill, Jordi|||0000-0003-0087-7489
  • Montoliu, Helena
  • Moustafa, Abdel Hakim|||0000-0001-6077-6888
  • Olivares, Andy Luis|||0000-0002-7284-0696
  • Albors, Carlos
  • Aguado, Ainhoa M.|||0000-0003-3281-4298
  • Medina, Elodie
  • Ceresa, Mario
  • Freixa, Xavier|||0000-0002-3203-9060
  • Arzamendi, Dabit|||0000-0001-7543-5867
  • Cochet, Hubert
  • Camara, Oscar|||0000-0002-5125-6132
Advanced visual computing solutions and three-dimensional (3D) printing are moving from engineering to clinical pipelines for training, planning, and guidance of complex interventions. 3D imaging and rendering, virtual reality (VR), and in-silico simulations, as well as 3D printing technologies provide complementary information to better understand the structure and function of the organs, thereby improving and personalizing clinical decisions. In this study, we evaluated several advanced visual computing solutions, such as web-based 3D imaging visualization, VR, and computational fluid simulations, together with 3D printing, for the planning of the left atrial appendage occluder (LAAO) device implantations. Six cardiologists tested different technologies in pre-operative data of five patients to identify the usability, limitations, and requirements for the clinical translation of each technology through a qualitative questionnaire. The obtained results demonstrate the potential impact of advanced visual computing solutions and 3D printing to improve the planning of LAAO interventions as well as the need for their integration into a single workflow to be used in a clinical environment.