Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Engineered Protein-Based Ionic Conductors for Sustainable Energy Storage Applications

  • Cortés-Ossa, Juan David
  • Blesio, Paolo
  • Fernandez-Castro, Marcial
  • Almonte, Lisa
  • Fernandez, Maxence
  • Liutkus, Mantas
  • Pandurangan, Perumal
  • Sabater, Carlos
  • Villaverde, Aitor
  • Melle-Franco, Manuel
  • Ashkenazy, Nurit
  • Jiménez-Ángeles, Felipe
  • Morant-Miñana, M. Carmen
  • Calvo, M. Reyes
  • Cortajarena, Aitziber L.
  • Sabater, Carlos|||/items/dde13588-5758-450f-b6c3-494d08459c4d
Protein-based biomaterials offer sustainable and biocompatible alternatives to traditional ionic conductors, essential for advancing green energy storage and bioelectronic applications. In this work, a robust, intrinsically self-assembling repeat protein scaffold to enhance ionic conductivity through the selective incorporation of glutamic acids is engineered. These mutations increase the number of available protonation sites and promote the formation of well-defined charge pathways. The self-assembly properties of the system enable the propagation of molecular-level modifications to the macroscopic scale, yielding self-standing protein films with significantly improved ionic conductivity. Specifically, engineered protein-based films exhibit an order of magnitude higher conductivity than their unmodified counterparts, with a further ten-fold enhancement through controlled addition of salt ions. Mechanistic analysis shows that the conductivity enhancement originates from the intertwined contributions of proton transport, hydration, and ion diffusion, all promoted by engineered charged residues. Finally, films of the best-performing variant are integrated, as both separator and electrolyte, into a supercapacitor device with competitive energy storage performance. These findings highlight the potential of rational protein design to create biocompatible, sustainable, and efficient ionic conductors with the stability and processability required to be successfully integrated into the next generation of energy storage and bioelectronic devices.
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Engineering Proteins for PEDOT Dispersions: A New Horizon for Highly Mixed Ionic-Electronic Biocompatible Conducting Materials

  • Dominguez-Alfaro, Antonio
  • Casado, Nerea
  • Fernandez, Maxence
  • Garcia-Esnaola, Andrea
  • Calvo, Javier
  • Mantione, Daniele
  • Calvo, M. Reyes
  • Cortajarena, Aitziber L.
Poly (3,4-ethylenedioxythiophene) (PEDOT) doped with polystyrene sulfonate (PSS) is the most used conducting polymer from energy to biomedical applications. Despite its exceptional properties, there is a need for developing new materials that can improve some of its inherent limitations, e.g., biocompatibility. In this context, doping PEDOT is propose with a robust recombinant protein with tunable properties, the consensus tetratricopeptide repeated protein (CTPR). The doping consists of an oxidative polymerization, where the PEDOT chains are stabilized by the negative charges of the CTPR protein. CTPR proteins are evaluated with three different lengths (3, 10, and 20 identical CTPR units) and optimized varied synthetic conditions. These findings revealed higher doping rate and oxidized state of the PEDOT chains when doped with the smallest scaffold (CTPR3). These PEDOT:CTPR hybrids possess ionic and electronic conductivity. Notably, PEDOT:CTPR3 displayed an electronic conductivity of 0.016 S cm−1, higher than any other reported protein-doped PEDOT. This result places PEDOT:CTPR3 at the level of PEDOT-biopolymer hybrids, and brings it closer in performance to PEDOT:PSS gold standard. Furthermore, PEDOT:CTPR3 dispersion is successfully optimized for inkjet printing, preserving its electroactivity properties after printing. This approach opens the door to the use of these novel hybrids for bioelectronics.
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Tuning the Dimensionality of Protein–Peptide Coassemblies to Build 2D Conductive Nanomaterials

  • Perez-Chirinos, Laura
  • Almonte, Lisa
  • Cortés-Ossa, Juan David
  • Solano, Eduardo
  • Calvo, M. Reyes
  • Sasselli, Ivan R.
  • Cortajarena, Aitziber L.
The natural self-assembly tendency of proteins to build complex structural architectures has kindled inspiration in developing supramolecular structures through the rational design of biomacromolecules. While there has been significant progress in achieving precise control over the morphology of self-assembled structures, combining different molecules within assemblies enables the design of materials with increased complexity, sophisticated structures, and a broad spectrum of functionalities. Here, the development of 1D and 2D peptide–protein coassembled systems based on the design of amphiphilic peptides and engineered proteins is described. The peptide was optimized to form stable self-assembled fibers by evaluating, computationally and experimentally, the assembling tendencies and the supramolecular features of peptides with different lengths and negative charges. A superhelical repeat protein was engineered by fusing one or two amphiphilic peptides into one or both termini. This modification drove the coassembly between the self-assembled fibers and the protein with one or two peptides, resulting in 1D or 2D coassembled systems. The protein films and the 2D coassembled system exhibited high ionic conductivity for a biomolecular system, attributed to their high content of charged residues, positioning these materials as promising candidates for developing bioelectronic devices. Thus, this work provides a versatile framework for developing coassembled materials with tunable dimensionality by using biocompatible building blocks without any additional chemical moieties, highlighting the potential for their use in biocompatible electronics.
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Thickness Determination and Control in Protein-Based Biomaterial Thin Films

  • Almonte, Lisa
  • Fernandez, Maxence
  • Cortés-Ossa, Juan David
  • Blesio, Paolo
  • Juan-Bordera, Lucía
  • Sabater, Carlos
  • Cortajarena, Aitziber L.
  • Calvo, M. Reyes
  • Sabater, Carlos|||/items/dde13588-5758-450f-b6c3-494d08459c4d
Controlling the thickness and uniformity of biomaterial films is crucial for their application in various fields including sensing and bioelectronics. In this work, we investigated film assemblies of an engineered repeat protein─specifically, the consensus tetratricopeptide repeat (CTPR) protein ─a system with unique robustness and tunability. We propose the use of microreflectance spectroscopy and apparent color inspection for the quick assessment of the thickness and uniformity of protein-based biomaterial films deposited on oxidized silicon substrates. Initially, we characterized the thickness of large, uniform, spin-coated protein films and compared the values obtained from microreflectance spectroscopy with those obtained from other typical methods, such as ellipsometry and atomic force microscopy. The excellent agreement between the results obtained from the different techniques validates the effectiveness of microreflectance as a fast, noninvasive, and affordable technique for determining the thickness of biomaterial films. Subsequently, we applied microreflectance spectroscopy to determine the thickness of drop-casted CTPR-based films prepared from small protein solution volumes, which present a smaller surface area and are less uniform compared to spin-coated samples. Additionally, we demonstrate the utility of apparent color inspection as a tool for assessing film uniformity. Finally, based on these results, we provide a calibration of film thickness as a function of the protein length and concentration for both spin-coated and drop-casted films, serving as a guide for the preparation of CTPR films with a specific thickness. Our results demonstrate the remarkable reproducibility of the CTPR film assembly, enabling the simple preparation of biomaterial films with precise thickness.