Skip to main content

SISTEMAS INTELIGENTES PARA LA MONITORIZACION Y EVALUACION DE EDIFICIOS DE OBRA DE FABRICA TRAS SER SOMETIDOS A ACCIONES EXTRAORDINARIAS: RIESGOS GEOTECNICOS, FUEGO, IMPACTOS,

BIA2014-59036-R

•
Funding agency name Ministerio de Economía y Competitividad
Funding agency acronym MINECO
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2014
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Management unit Secretaría de Estado de Educación, Formación Profesional y Universidades
Beneficiary centre UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Dynamic changes on a masonry cross vault after a forced damage

  • Bru, David
  • Ivorra, Salvador
  • Torres, Benjamín
  • Bru, David|||/items/00098396-76d2-44fc-8652-746908d86a33
  • Ivorra, Salvador|||/items/f458a5ac-f699-440d-ad8a-ca0b6fec91bd
  • Torres, Benjamín|||/items/605a19b9-d11e-44d5-b7d8-28a71eaaaa72
This work shows the preliminary results related to the evaluation of the dynamic behavior of a 5x5 m masonry cross vault after undergoing different changes in its structural behavior. It has been built using solid clay bricks and lime and sand mortar. The cross vault has been built in the laboratory specifically for carrying out these tests and evaluating its structural behavior. A device has been designed to be able to carry out a controlled settling of one of its supports without causing an instantaneous collapse of the structure. Dynamic identification using OMA was performed by installing seismic accelerometers at several selected points on the structure, using ARTEMIS software to analyze the results. The evolution of the dynamic characteristics was carried out in four different states: (i) After construction (ii) After the generation of generalized damage through the forced settlement of one of its supports. (iii) After repair using Textile Reinforced Mortars (TRM) (iv) After generating new damage by settling one of its supports in the TRM repaired structure. After the generation of the damage in the structure, important cracks are observed in various points of the structure, although no situation was reached that would foresee a possible collapse. The repair with TRM has consisted of the introduction of fiberglass mesh bands coated in lime and sand mortar. These bands have been arranged forming a cross in the upper part of the structure and in all the edge arches of the structure. In all these phases the OMA was developed under a situation of ambient vibrations, where these vibrations levels were very low due to the situation inside of a laboratory. After each of these phases, their main frequencies, their vibration modes and the structural damping factor of each of the identified modes have been obtained. It is observed how a loss of rigidity of the vault occurs after the production of damage and how it completely recovers by means of reinforcement and repair with TRM. An increase in the damping ratio of practically all the vibration modes has been detected when the structure is damaged, although after repair with TRM these values are reduced again.
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Unreinforced and TRM-Reinforced Masonry Building Subjected to Pseudodynamic Excitations: Numerical and Experimental Insights

  • Giordano, Ersilia
  • Bertolesi, Elisa
  • Clementi, Francesco
  • Buitrago, Manuel
  • Adam, Jose M.
  • Ivorra, Salvador
  • Ivorra, Salvador|||/items/f458a5ac-f699-440d-ad8a-ca0b6fec91bd
This paper contains a numerical study based on tests carried out at the Universitat Politècnica de València (Spain) on a U-shaped unreinforced and Textile Reinforced Mortar (TRM)-reinforced masonry structure subjected to horizontal loads. The masonry was composed of clay bricks with 10 mm thick mortar joints arranged in an English bond pattern. The prototype was tested by applying pseudodynamic displacement-driven cycles and varying cyclic amplitudes and frequencies in two different stages: (1) on the as-built structure and (2) after the application of the TRM material. A series of nonlinear numerical simulations were performed adopting the ABAQUS/Explicit version 6.14 finite-element (FE) software. The FE calibration was carried out using the results obtained during ambient vibration tests. Simulations were then used to evaluate the effectiveness of the proposed TRM strengthening technique in improving the behaviour of low-rise old masonry building subjected to horizontal loads.