Skip to main content

SISTEMAS INTELIGENTES PARA LA MONITORIZACION Y EVALUACION DE EDIFICIOS DE OBRA DE FABRICA TRAS SER SOMETIDOS A ACCIONES EXTRAORDINARIAS: RIESGOS GEOTECNICOS, FUEGO, IMPACTOS,

BIA2014-59036-R

•
Funding agency name Ministerio de Economía y Competitividad
Funding agency acronym MINECO
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2014
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Management unit Secretaría de Estado de Educación, Formación Profesional y Universidades
Beneficiary centre UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 10
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Research and practice on masonry cross vaults A review

  • Bertolesi, Elisa
  • Rinaudo, Paula
  • Adam, Jose M|||0000-0002-9205-8458
  • Calderón García, Pedro Antonio|||0000-0002-9783-9333
[EN] Masonry cross vaults, which began to be built in Europe in the times of the Roman Empire and reached heights of extraordinary splendor during the Gothic Period, are part of an impressive architectural heritage, which stand in need of evaluation, maintenance and repairs or renovation. Nowadays, the requirements of preservation and conservation of the historical heritage call for a strategy oriented on the description of the structural behaviour from different characteristic perspectives without neglecting the functional, architectonic and structural features. The present paper is intended to discuss the different research approaches adopted by several authors during the past and to show how numerical simulations in conjunction with experimental studies can provide the tools for the quantification of the damages produced by a variety of different critical events. To this scope, this paper includes an extensive and somewhat ambitious review, dealing with a wide variety of aspects, such as: (a) a bibliometric study, (b) classification of the types of cross vaults, (c) structural behavior, (d) types of failures and damage, (e) numerical simulation, (f) experimental testing, (g) monitoring, and (h) retrofitting. The review is expected to be of great interest for architects and engineers working in the field of evaluating and retrofitting the architectural heritage, as well as to those researchers who would find it useful to have at hand in a single document the most important advances made in the field of masonry cross vaults in recent years., This work was carried out within the SIMAX Project (BIA2014-59036-R) financed by the Spanish Ministry for the Economy, Industry and Competitiveness. The authors wish to express their gratitude to the collaborators and participants of the SIMAX Project: Juan J. Moragues, Teresa M. Pellicer, Ignacio Paya-Zaforteza, Ignazio Floris, Manuel Buitrago, Benjamin Torres, Salvador Ivorra, David Bru, Michele Betti, Lorenzo Papini, Eugenio Pellis, Mercedes Gomez-Ferrer and Gabriele Milani. The first author (Elisa Bertolesi) would like to thank the Universitat Politecnica de Valencia for funding received for her postdoctoral grant (PAID-10-17).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Unreinforced and TRM-reinforced masonry building subjected to pseudo-dynamic excitations: numerical and experimental insights

  • Giordano, Ersilia
  • Bertolesi, Elisa
  • Clementi, Francesco
  • Ivorra Chorro, Salvador
  • Buitrago, Manuel|||0000-0002-5561-5104
  • Adam, Jose M|||0000-0002-9205-8458
[EN] This paper contains a numerical study based on tests carried out at the Universitat Politècnica de València (Spain) on a U-shaped unreinforced and TRM-reinforced masonry building structure subjected to horizontal loads. The masonry was composed of clay bricks with 10 mm thick mortar joints arranged in an English bond manner. The prototype was tested by applying pseudo-dynamic displacement-driven cycles and varying cyclic amplitudes and frequencies in two different stages: (i) on the as-built structure and (ii) after the repair and the application of Textile Reinforced Mortar (TRM) material. A series of non-linear numerical simulations were performed adopting the ABAQUS/Explicit FE software. The FE calibration was carried out using the results obtained during ambient vibration tests. Simulations were then used to evaluate the effectiveness of the proposed TRM technique to increasing the strength of low-rise old masonry building structures., The authors would like to express their gratitude to the Spanish Ministry of Economy, Industry and Competitiveness for the funding provided (BIA 2014-59036-R-AR), and also to the Grupo Mapei and Grupo Puma for their invaluable assistance during the experimental tests.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Experimental investigation of a full-scale timbrel masonry cross vault subjected to vertical settlement

  • Torres Górriz, Benjamín
  • Bertolesi, Elisa
  • Moragues, Juan J|||0000-0001-8111-5480
  • Calderón García, Pedro Antonio|||0000-0002-9783-9333
  • Adam, Jose M|||0000-0002-9205-8458
[EN] Masonry cross vaults are among the most attractive structures ever created by the human race. Although cross vaults have been the subject of various numerical and experimental studies, they are still in need of further investigation. In the research described here, carried out at the ICITECH laboratories of the Universitat Politecnica de Valencia (Spain), a full-scale timbrel cross vault was constructed and tested under the vertical settlement of one of its supports. The geometry and construction technique of the vault resembled those in a church on the outskirts of Valencia, one of which had collapsed due to a soil settlement. The timbrel vault's behaviour was monitored by 23 sensors placed on its inner and outer surfaces and subsequently analysed from the results obtained in the tests. As expected, the vault experienced a fairly ductile response during the test, while peculiar crack patterns were observed in the form of bending cracks in the lateral arches, which were mostly found to follow the mortar joints in the upper surface of one of the diagonal elliptic arches., The authors wish to express their gratitude to the Spanish Ministry of Economy, Industry and Competitiveness for the funding provided through Project BIA 2014-59036-R, and also to LIC-Levantina Ingenieria y Constructiin and Grupo Puma for their invaluable assistance.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Analysis of the fire resistance of timber jack arch flooring systems used in historical buildings

  • Garcia-Castillo, Ester
  • Paya-Zaforteza, Ignacio
  • Hospitaler Pérez, Antonio|||0000-0001-7108-3104
[EN] Conservation of built heritage, at present, is a major task and a great challenge because it requires adapting the performance of existing buildings to current code requirements, when very often these were built before codes existed. Timber jack arch flooring systems can be found in many historical buildings around the world. The system is formed by timber joists and brick vaults spanning the distance between two adjacent joists and has an undoubtable aesthetic and cultural value. However, given its geometry, there is no methodology to verify its fire resistance, which has prevented the preservation of many buildings using this system. Within this context, this paper proposes a methodology based on the ¿Reduced cross-section method¿ included in Eurocode 5 (EN 1995-1-2) for the determination of the fire resistance of historical timber jack arch flooring systems subjected to different fire exposures. The methodology is based on the use of the 135-degree and the 300-degree isotherms to obtain the positions of the zero-strength layer and the charring depths, and is supported by both advanced numerical thermal models experimentally validated for standard fire exposure and advanced mechanical models. The methodology has been applied to a wide number of flooring systems covering different span lengths, timber static bending strengths, and fire exposures to evaluate the influence of these parameters on fire resistance. Results show that historical buildings do not always meet the requirements set by current codes and, therefore, performing these analyses is essential to ensure the fire resistance of these timber structures. By doing so, this work also contributes to cultural heritage conservation and to more sustainable construction in alignment with the fulfilment of United Nations 2030 Agenda¿s eleventh goal: "Sustainable cities and communities"., The authors wish to express their gratitude to the Spanish Ministry of Economy, Industry and Competitiveness for the funding provided through Project BIA 2014-59036R. This research is also supported by the Spanish Ministry of Science, Innovation and Universities through the PhD grant FPU18/00726 awarded to the first author. Finally, the au-thors want to thank Prof. Dr. Juan Patricio Hidalgo for his help and MSc Enrique Serra for his assistance in the experimental test.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Effectiveness of Textile Reinforced Mortar (TRM) Materials in preventing Seismic-Induced Damage in a U-Shaped Masonry Structure Submitted to Pseudo-Dynamic Excitations

  • Bertolesi, Elisa
  • Giordano, Ersilia
  • Clementi, Francesco
  • Buitrago, Manuel|||0000-0002-5561-5104
  • Calderón García, Pedro Antonio|||0000-0002-9783-9333
  • Moragues, Juan J|||0000-0001-8111-5480
  • Adam, Jose M|||0000-0002-9205-8458
[EN] This paper presents the experimental results obtained from tests on a 2/3 scale U-shaped masonry building constructed in one of the ICITECH laboratories at the Universitat Politecnica de Valencia (Spain). The prototype measured 3.31 x 4.19 m(2) by 2.15 m high and had a wall thickness of 230 mm. The masonry was composed of 230 x 110 x 50 mm(3) solid clay bricks with approximately 10 mm-thick mortar joints arranged in English bond. The tests were aimed at evaluating the effectiveness of cement-based reinforcing materials (Textile Reinforced Mortar) applied to weak masonry substrates severely damaged by horizontal loads such as those induced by a seismic event. The tests were carried out in three phases: (i) testing of the as-built structure, (ii) application of one external layer of TRM to restore the masonry's original load-bearing capacity and then (iii) testing the TRM-strengthened structure. Dynamic behaviour was monitored by both traditional and fibre optic sensors (FO), including 28 Linear Variable Displacement Transducers (LVDTs) and 3 long-gauge optical sensors. Strengthening effectiveness was evaluated by several parameters: hysteretic curves, strength degradation, computed cumulative energy dissipation and cracking mechanisms. TRM reinforcement was shown to significantly extend the load-bearing and displacement capacity of the masonry prototype, reducing seismic-induced damage applied by pseudodynamic excitation, although it had a limited effect on cumulative energy dissipation.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Effectiveness of Textile Reinforced Mortar (TRM) materials for the repair of full-scale timbrel masonry cross vaults

  • Bertolesi, Elisa
  • Torres Górriz, Benjamín
  • Adam, Jose M|||0000-0002-9205-8458
  • Calderón García, Pedro Antonio|||0000-0002-9783-9333
  • Moragues, Juan J|||0000-0001-8111-5480
[EN] This paper presents the experimental results obtained from tests on two masonry vaults reinforced by Textile Reinforced Mortar (TRM) materials subjected to monotonic and cyclic vertical settlements in one of their sup-ports. Two full-scale square masonry timbrel vaults were built in one of ICITECH's laboratories at the Universitat Politecnica de Valencia (Valencia, Spain) using the traditional Catalan layered-construction technique, with various layers of clay tiles arranged in two perpendicular masonry textures joined by lime and cement mortar joints. Due to their peculiar geometric and mechanical features, i.e. their high slenderness ratio, low tensile strength and high material heterogeneity, these structures are especially prone to damage from high-risk events such as soil settlement or seismic excitation. To evaluate their response to vertical support displacements, both vaults were pre-damaged by either vertical monotonic or cyclic settlements. They were then strengthened by a radial TRM strengthening configuration and re-tested until failure. A complex network of traditional and optical sensors was used to monitor displacements, deformation and the development of the cracking mechanism under both settlement conditions. The results obtained show that TRM materials can be used to effectively repair severely damaged masonry timbrel vaults, helping to partially restore the initial elastic stiffness, as well as doubling the vaults' elastic phase and ultimate displacements. In addition, TRM materials did not alter the stiffness degradation trend, although they had a strong effect on peak reaction degradation and failure modes. This investigation represents a valuable and unique source of information about the efficacy of TRM materials to repair full-scale pre-damaged masonry timbrel vaults., The authors wish to express their gratitude to the Spanish Ministry of Economy, Industry and Competitiveness for the funding provided through Project BIA 2014-59036-R, and also to LIC-Levantina Ingenieria y Construccion and the Grupo Mapei for their invaluable assistance. The first author (Elisa Bertolesi) would like to thank the Universitat Politecnica de Valencia for funding received for her postdoctoral grant (PAID-10-17).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A full-scale timbrel cross vault subjected to vertical cyclical displacements in one of its supports

  • Torres Górriz, Benjamín
  • Bertolesi, Elisa
  • Calderón García, Pedro Antonio|||0000-0002-9783-9333
  • Moragues, Juan J|||0000-0001-8111-5480
  • Adam, Jose M|||0000-0002-9205-8458
[EN] Up-and-down cyclical displacement of supports-foundations, due for example to the presence of expansive soils, can affect the integrity of a structure and may even lead to its collapse. A recent study carried out at the ICITECH laboratories of the Universitat Politècnica de València analysed the effects of earth settlements on the behaviour of masonry cross vaults. One of the tests involved the construction and testing of a full-scale timbrel cross vault, one of whose supports was subjected to up-and-down vertical displacement cycles. The 4×4 m2 vault was composed of four 3.6 m diameter arches supporting a masonry web. Vertical displacements were applied to one of the supports by means of two synchronised mechanical jacks. The results of the tests provide valuable information to the scientific community, architects and engineers on the behaviour of timbrel cross vaults when one of their supports is subjected to cyclical movements., The authors wish to express their gratitude to the Spanish Ministry of Economy, Industry and Competitiveness for the funding provided through Project BIA 2014-59036-R, and also to LIC-Levantina Ingenieria y Construction and the Grupo Puma for their invaluable assistance. The second author (Elisa Bertolesi) would like to thank the Universitat Politecnica de Valencia for funding received for her postdoctoral grant (PAID-10-17).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Estudio experimental sobre una bóveda tabicada de crucería a escala real sometida a asiento vertical en uno de sus apoyos

  • Moragues, Juan J|||0000-0001-8111-5480
  • Calderón García, Pedro Antonio|||0000-0002-9783-9333
  • Adam, Jose M|||0000-0002-9205-8458
  • Pellicer, Teresa M.|||0000-0002-0072-678X
  • Torres Górriz, Benjamín
[ES] La sociedad actual está cada vez más concienciada con la necesidad de mantener el patrimonio construido. A pesar de los esfuerzos que se han venido llevando a cabo para mantener dicho patrimonio, aún queda mucho trabajo por hacer. Una de las mayores preocupaciones actuales viene de los fallos que pueden ocasionar las acciones accidentales y eventos extremos sobre los edificios que el ser humano emplea para diferentes usos. De acuerdo con las necesidades actuales, en el ICITECH (Universitat Politècnica de València) se está desarrollando el proyecto SIMAX, mediante el cual se pretende estudiar, entre otras acciones, el efecto de los asientos del terreno en diferentes elementos estructurales de obra de fábrica. Recientemente, se ha ensayado una bóveda tabicada de crucería a escala real, con unas dimensiones en planta aproximadas de 4×4 m2. Dicha bóveda de crucería, que es idéntica a las existentes en la iglesia de San Lorenzo de Castell de les Cabres (Castellón, España), ha sido sometida a un asiento en uno de sus apoyos con el fin de caracterizar su comportamiento. Este artículo muestra los resultados preliminares más significativos del ensayo., Los autores quieren expresar su gratitud al Ministerio de Economía, Industria y Competitividad por la financiación del proyecto BIA 2014-59036-R y a las empresas Levantina Ingeniería y Construcción SL y Grupo Puma, por su ayuda y colaboración
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Dynamic changes on a masonry cross vault after a forced damage

  • Bru, David
  • Ivorra, Salvador
  • Torres, Benjamín
  • Bru, David|||/items/00098396-76d2-44fc-8652-746908d86a33
  • Ivorra, Salvador|||/items/f458a5ac-f699-440d-ad8a-ca0b6fec91bd
  • Torres, Benjamín|||/items/605a19b9-d11e-44d5-b7d8-28a71eaaaa72
This work shows the preliminary results related to the evaluation of the dynamic behavior of a 5x5 m masonry cross vault after undergoing different changes in its structural behavior. It has been built using solid clay bricks and lime and sand mortar. The cross vault has been built in the laboratory specifically for carrying out these tests and evaluating its structural behavior. A device has been designed to be able to carry out a controlled settling of one of its supports without causing an instantaneous collapse of the structure. Dynamic identification using OMA was performed by installing seismic accelerometers at several selected points on the structure, using ARTEMIS software to analyze the results. The evolution of the dynamic characteristics was carried out in four different states: (i) After construction (ii) After the generation of generalized damage through the forced settlement of one of its supports. (iii) After repair using Textile Reinforced Mortars (TRM) (iv) After generating new damage by settling one of its supports in the TRM repaired structure. After the generation of the damage in the structure, important cracks are observed in various points of the structure, although no situation was reached that would foresee a possible collapse. The repair with TRM has consisted of the introduction of fiberglass mesh bands coated in lime and sand mortar. These bands have been arranged forming a cross in the upper part of the structure and in all the edge arches of the structure. In all these phases the OMA was developed under a situation of ambient vibrations, where these vibrations levels were very low due to the situation inside of a laboratory. After each of these phases, their main frequencies, their vibration modes and the structural damping factor of each of the identified modes have been obtained. It is observed how a loss of rigidity of the vault occurs after the production of damage and how it completely recovers by means of reinforcement and repair with TRM. An increase in the damping ratio of practically all the vibration modes has been detected when the structure is damaged, although after repair with TRM these values are reduced again.
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Unreinforced and TRM-Reinforced Masonry Building Subjected to Pseudodynamic Excitations: Numerical and Experimental Insights

  • Giordano, Ersilia
  • Bertolesi, Elisa
  • Clementi, Francesco
  • Buitrago, Manuel
  • Adam, Jose M.
  • Ivorra, Salvador
  • Ivorra, Salvador|||/items/f458a5ac-f699-440d-ad8a-ca0b6fec91bd
This paper contains a numerical study based on tests carried out at the Universitat Politècnica de València (Spain) on a U-shaped unreinforced and Textile Reinforced Mortar (TRM)-reinforced masonry structure subjected to horizontal loads. The masonry was composed of clay bricks with 10 mm thick mortar joints arranged in an English bond pattern. The prototype was tested by applying pseudodynamic displacement-driven cycles and varying cyclic amplitudes and frequencies in two different stages: (1) on the as-built structure and (2) after the application of the TRM material. A series of nonlinear numerical simulations were performed adopting the ABAQUS/Explicit version 6.14 finite-element (FE) software. The FE calibration was carried out using the results obtained during ambient vibration tests. Simulations were then used to evaluate the effectiveness of the proposed TRM strengthening technique in improving the behaviour of low-rise old masonry building subjected to horizontal loads.