How the heterogeneity of the severely injured brain affects hybrid diffuse optical signals, case examples and guidelines

  • Tagliabue, Susanna
  • Kacprzak, Michał|||0000-0002-3149-837X
  • Rey Pérez, Anna|||0000-0001-6014-3829
  • Baena, Jacinto
  • Riveiro, Marilyn|||0000-0002-1645-3720
  • Maruccia, Federica|||0000-0002-3774-7875
  • Fischer, Jonas B.|||0000-0003-4178-0261
  • Poca Pastor, María Antonia|||0000-0002-3831-0536
  • Durduran, Turgut|||0000-0001-5838-1027
A shortcoming of the routine clinical use of diffuse optics (DO) in the injured head has been that the results from commercial near-infrared spectroscopy-based devices are not reproducible, often give physiologically invalid values, and differ among systems. Besides the limitations due to the physics of continuous-wave light sources, one culprit is the head heterogeneity and the underlying morphological and functional abnormalities of the probed tissue. The aim is to investigate the effect that different tissue alterations in the damaged head have on DO signals and provide guidelines to avoid data misinterpretation. DO measurements and computed tomography scans were acquired on brain-injured patients. The relationship between the signals and the underlying tissue types was classified on a case-by-case basis. Examples and suggestions to establish quality control routines were provided. The findings suggested guidelines for carrying out DO measurements and speculations toward improved devices. We advocate for the standardization of the DO measurements to secure a role for DO in neurocritical care. We suggest that blind measurements are unacceptably problematic due to confounding effects and care using a priori and a posteriori quality control routines that go beyond an assessment of the signal-to-noise ratio that is typically utilized.
Dipòsit Digital de la UB
Publication Artículo científico (JournalArticle)

Peripheral microcirculatory alterations are associated with the severity of acute respiratory distress syndrome in COVID-19 patients admitted to intermediate respiratory and intensive care units

  • Mesquida, Jaume
  • Caballer, Alba
  • Cortese, Lorenzo
  • Vilà, Clara
  • Karadeniz, Umut
  • Pagliazzi, Marco
  • Zanoletti, Marta
  • Pérez Pacheco, Argelia
  • Castro Rebollo, Pedro
  • García-de-Acilu, Marina
  • Mesquita, Rickson Coelho
  • Busch, David R.
  • Durduran, Turgut
  • HEMOCOVID-19 Consortium
Background: COVID-19 is primarily a respiratory disease; however, there is also evidence that it causes endothelial damage in the microvasculature of several organs. The aim of the present study is to characterize in vivo the microvas‑ cular reactivity in peripheral skeletal muscle of severe COVID-19 patients. Methods: This is a prospective observational study carried out in Spain, Mexico and Brazil. Healthy subjects and severe COVID-19 patients admitted to the intermediate respiratory (IRCU) and intensive care units (ICU) due to hypox‑ emia were studied. Local tissue/blood oxygen saturation (StO2) and local hemoglobin concentration (THC) were non-invasively measured on the forearm by near-infrared spectroscopy (NIRS). A vascular occlusion test (VOT), a threeminute induced ischemia, was performed in order to obtain dynamic StO2 parameters: deoxygenation rate (DeO2), reoxygenation rate (ReO2), and hyperemic response (HAUC). In COVID-19 patients, the severity of ARDS was evaluated by the ratio between peripheral arterial oxygen saturation (SpO2) and the fraction of inspired oxygen (FiO2) (SF ratio). Results: Healthy controls (32) and COVID-19 patients (73) were studied. Baseline StO2 and THC did not difer between the two groups. Dynamic VOT-derived parameters were signifcantly impaired in COVID-19 patients showing lower metabolic rate (DeO2) and diminished endothelial reactivity. At enrollment, most COVID-19 patients were receiving invasive mechanical ventilation (MV) (53%) or high-fow nasal cannula support (32%). Patients on MV were also receiv‑ ing sedative agents (100%) and vasopressors (29%). Baseline StO2 and DeO2 negatively correlated with SF ratio, while ReO2 showed a positive correlation with SF ratio. There were signifcant diferences in baseline StO2 and ReO2 among the diferent ARDS groups according to SF ratio, but not among diferent respiratory support therapies. Conclusion: Patients with severe COVID-19 show systemic microcirculatory alterations suggestive of endothelial dysfunction, and these alterations are associated with the severity of ARDS. Further evaluation is needed to determine
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Hybrid diffuse optical appraisal of peripheral and cerebral changes in critically ill patients receiving red blood cell transfusion

  • Tagliabue, Susanna
  • Rey-Perez, Anna
  • Exposito, Lourdes
  • Jimenez, Andrés F.
  • Valles Angulo, Sara
  • Maruccia, Federica
  • Fischer, Jonas
  • Kacprzak, Michal
  • Poca, Maria A.
  • Durduran, Turgut
Significance: Red blood cell transfusions (RBCTs) to restore hemoglobin concentration and hematocrit values in anemic patients are debated in critical illness. Aim: We used non-invasive hybrid diffuse optics (DO) to study RBCT’s effect on the brain and peripheral muscle evaluated in critically ill patients. Approach: Critically ill patients admitted to the neurotrauma intensive care unit of the Vall d’Hebron University Hospital that required blood transfusion were included in the study and continuously monitored by DO methods alongside time-specific blood gas samples. Results: In 14 patients, blood-derived hemoglobin, hematocrit, and DO-derived metabolic rate of oxygen, oxy- and total hemoglobin significantly increased after RBCT. Oxygen extraction fraction significantly decreased. Blood flow significantly increased only in muscles. Deoxy-hemoglobin concentration remained unchanged. No significant differences were found between cerebral and peripheral signals post-RBCT, except for the metabolic rate of oxygen (higher in muscle). Conclusion: Hybrid DO monitoring quantifies cerebral and peripheral microvascular changes during red blood cell transfusion, enabling insights into oxygen metabolism and advancing critical care management., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Redefining Idiopathic Normal Pressure Hydrocephalus Using AI-Driven Brain Volumetry

  • Sahuquillo, Juan
  • AlNusaif, Murad
  • Sahuquillo-Muxi, Aasma
  • Duch, Paula
  • Poca, Maria-Antonia
Idiopathic normal pressure hydrocephalus (iNPH) is a potentially reversible cause of gait disturbance and cognitive impairment in older adults, yet its diagnosis remains challenging and controversial. The core difficulty lies in distinguishing true hydrocephalus from ventricular enlargement secondary to cerebral atrophy or neurodegenerative disease, a distinction now recognized as non-binary. In many patients, ventricular enlargement reflects a continuum ranging from predominantly hydrocephalic iNPH to mixed pathological states combining impaired cerebrospinal fluid (CSF) dynamics and neurodegeneration. Conventional neuroradiological markers, including the Evans Index, the callosal angle, and the disproportionately enlarged subarachnoid-space hydrocephalus (DESH) pattern, provide useful qualitative guidance but are limited by their two-dimensional nature, interobserver variability, and poor sensitivity for differential diagnosis and outcome prediction. Over the past decade, advances in artificial intelligence-based brain volumetry (AI-BrV) have introduced a new paradigm for quantitative structural assessment. By enabling automated, anatomically precise, and reproducible three-dimensional quantification of ventricular and extraventricular CSF, cortical and subcortical gray matter, deep gray matter nuclei, and periventricular white matter, AI-BrV addresses many limitations of traditional imaging approaches. Beyond absolute volume measurements, AI-BrV enables the derivation of composite indices and ratios that may capture disease-specific structural phenotypes and better reflect the underlying pathophysiology of ventricular enlargement. Importantly, AI-BrV pipelines can be applied retrospectively to large legacy neuroimaging datasets and compared with extensive publicly available repositories, facilitating normative modeling, cross-disease analyses, and external validation of volumetric biomarkers. When integrated with clinical data and multivariable statistical or machine-learning frameworks, these approaches hold promise for improving patient selection, refining disease categorization, and supporting more rational decision-making regarding CSF diversion. In this context, AI-BrV offers a unifying framework for reconciling divergent clinical perspectives and advancing iNPH toward a more precise, reproducible, and evidence-based diagnostic and therapeutic paradigm., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

How the heterogeneity of the severely injured brain affects hybrid 2 diffuse optical signals: case examples and guidelines

  • Tagliabue, Susanna
  • Kacprzak, Michal
  • Rey-Perez, Anna
  • Baena, Jacinto
  • Riveiro, Marilyn
  • Maruccia, Federica
  • Fischer, Jonas
  • Poca, Maria A.
  • Durduran, Turgut
Significance: A shortcoming for the routine clinical use of diffuse optics (DO) in the injured head has been that the results from commercial near-infrared spectroscopy-based devices are not reproducible, often give phys iologically invalid values and differ between systems. Besides the limitations due to the physics of continuous23 wave light sources, one culprit is the head heterogeneity and the underlying morphological and functional abnor malities of the probed tissue. Aim: To investigate the effect that different tissue alterations in the damaged head has on DO signals and provide guidelines to avoid data misinterpretation. Approach: DO measurements and computed tomography scans were acquired on brain-injured patients. The relationship between the signals and the underlying tissue types was classified on a case-by-case basis. Results: Examples and suggestions to establish quality control routines were provided. The findings suggested guidelines for carrying out DO measurements and speculations towards improved devices. Conclusions: This study advocates for the standardization of the DO measurements to secure a role for DO in neurocritical care. We suggest that blind measurements are unacceptably problematic due to confounding effects and care using a priori and a posteriori quality control routines that go beyond an assessment of the signal-to-noise ratio that is typically utilized.
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Proof of concept validation of bioresorbable optical fibers for diffuse correlation spectroscopy

  • Pandayil, Jawad T.
  • Boetti, Nadia G.
  • Janner, Davide
  • Durduran, Turgut
  • Cortese, Lorenzo
Optical quality bioresorbable materials have been gaining interest in recent years for various interstitial biomedical/medical application. An example of this is when the implant gradually dissolves in the body, providing physiological information over extended periods of time, hence reducing the need for revision surgeries. This study reports for the first time the in-house fabrication of single mode (at 785 nm) calcium phosphate glass (CPG) based bioresorbable optical fibers and investigates their suitability for microvascular blood flow monitoring using diffuse correlation spectroscopy (DCS). Ex vivo experiments in liquid phantom and non-invasive in vivo experiments on the human forearm muscle were conducted using multimode and single mode CPG bioresorbable optical fibers. The retrieved flow index from the correlation curves acquired using CPG fibers was in good agreement with that obtained using standard silica (Si) fibers, both ex vivo and in vivo. The results demonstrate the potential of CPG optical fibers for further exploration., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Near-infrared diffuse optical characterization of human thyroid using ultrasound-guided hybrid time-domain and diffuse correlation spectroscopies

  • Fernández Esteberena, Pablo
  • Cortese, Lorenzo
  • Zanolotti, Marta
  • Lo Presti, Giuseppe
  • Aranda Velázquez, Gloria
  • Ruiz Janer, Sabina
  • Buttafava, Mauro
  • Renna, Marco
  • Di Sieno, Laura
  • Tosi, Alberto
  • Dalla Mora, Alberto
  • Wojtkewicz, Stanislaw
  • Dehbhani, Hamid
  • de Fraguier, Sixte
  • Nguyen-Dinh, An
  • Rosinski, Bogdan
  • Weigel, Udo M.
  • Sarangi, Dibya J.
  • Squarcia, Mattia
  • hanzu, Felicia A.
  • Contini, Davide
  • Mora Porta, Mireia
  • Durduran, Turgut
Thyroid vascularization and hemodynamics become altered in thyroid pathologies and could thus inform diagnostics, therapy planning, and follow-up. However, the current non-invasive monitoring methods available in clinics lack the necessary sensitivity and/or are impractical for large-scale deployment. As a step towards proposing a new modality, we applied the first platform, to our knowledge, designed to do simultaneous measurements of neck anatomy and thyroid microvascular hemodynamics and metabolism in a single probe placement, integrating state-of-the-art near-infrared spectroscopy techniques and clinical ultrasound. A rich dataset was formed with sixty-five subjects (forty-eight females), including eighteen healthy volunteers and forty-seven patients with thyroid nodules, characterizing thyroid tissue and the effects of demographic and anatomical variables while preserving the standard clinical workflow. We have found marked reductions with age and body mass index in thyroid total hemoglobin concentration (THC), tissue oxygen saturation (StO2), and blood flow index (BFi), among others. Patients showed lower THC and BFi than healthy subjects, and the limited sample of malignant nodules showed a higher StO2 than the benign. These findings support the need for personalized clinical approaches., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Hybrid diffuse optical appraisal of peripheral and cerebral changes in critically ill patients receiving red blood cell transfusion

  • Tagliabue, Susanna
  • Rey-Perez, Anna
  • Exposito, Lourdes
  • Jimenez, Andrés F.
  • Valles Angulo, Sara
  • Maruccia, Federica
  • Fischer, Jonas
  • Kacprzak, Michal
  • Poca, Maria A.
  • Durduran, Turgut
Significance: Red blood cell transfusions (RBCTs) to restore hemoglobin concentration and hematocrit values in anemic patients are debated in critical illness. Aim: We used non-invasive hybrid diffuse optics (DO) to study RBCT’s effect on the brain and peripheral muscle evaluated in critically ill patients. Approach: Critically ill patients admitted to the neurotrauma intensive care unit of the Vall d’Hebron University Hospital that required blood transfusion were included in the study and continuously monitored by DO methods alongside time-specific blood gas samples. Results: In 14 patients, blood-derived hemoglobin, hematocrit, and DO-derived metabolic rate of oxygen, oxy- and total hemoglobin significantly increased after RBCT. Oxygen extraction fraction significantly decreased. Blood flow significantly increased only in muscles. Deoxy-hemoglobin concentration remained unchanged. No significant differences were found between cerebral and peripheral signals post-RBCT, except for the metabolic rate of oxygen (higher in muscle). Conclusion: Hybrid DO monitoring quantifies cerebral and peripheral microvascular changes during red blood cell transfusion, enabling insights into oxygen metabolism and advancing critical care management., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Peripheral microcirculatory alterations are associated with the severity of acute respiratory distress syndrome in COVID-19 patients admitted to intermediate respiratory and intensive care units

  • Mesquida, Jaume
  • Caballer, Alba
  • Cortese, Lorenzo
  • Vilà, Clara
  • Karadeniz, Umut
  • Pagliazzi, Marco
  • Zanoletti, Marta
  • Pérez Pacheco, Argelia
  • Castro Rebollo, Pedro
  • García-de-Acilu, Marina
  • Mesquita, Rickson Coelho
  • Busch, David R.
  • Durduran, Turgut
  • HEMOCOVID-19 Consortium
Background: COVID-19 is primarily a respiratory disease; however, there is also evidence that it causes endothelial damage in the microvasculature of several organs. The aim of the present study is to characterize in vivo the microvas‑ cular reactivity in peripheral skeletal muscle of severe COVID-19 patients. Methods: This is a prospective observational study carried out in Spain, Mexico and Brazil. Healthy subjects and severe COVID-19 patients admitted to the intermediate respiratory (IRCU) and intensive care units (ICU) due to hypox‑ emia were studied. Local tissue/blood oxygen saturation (StO2) and local hemoglobin concentration (THC) were non-invasively measured on the forearm by near-infrared spectroscopy (NIRS). A vascular occlusion test (VOT), a threeminute induced ischemia, was performed in order to obtain dynamic StO2 parameters: deoxygenation rate (DeO2), reoxygenation rate (ReO2), and hyperemic response (HAUC). In COVID-19 patients, the severity of ARDS was evaluated by the ratio between peripheral arterial oxygen saturation (SpO2) and the fraction of inspired oxygen (FiO2) (SF ratio). Results: Healthy controls (32) and COVID-19 patients (73) were studied. Baseline StO2 and THC did not difer between the two groups. Dynamic VOT-derived parameters were signifcantly impaired in COVID-19 patients showing lower metabolic rate (DeO2) and diminished endothelial reactivity. At enrollment, most COVID-19 patients were receiving invasive mechanical ventilation (MV) (53%) or high-fow nasal cannula support (32%). Patients on MV were also receiv‑ ing sedative agents (100%) and vasopressors (29%). Baseline StO2 and DeO2 negatively correlated with SF ratio, while ReO2 showed a positive correlation with SF ratio. There were signifcant diferences in baseline StO2 and ReO2 among the diferent ARDS groups according to SF ratio, but not among diferent respiratory support therapies. Conclusion: Patients with severe COVID-19 show systemic microcirculatory alterations suggestive of endothelial dysfunction, and these alterations are associated with the severity of ARDS. Further evaluation is needed to determine
Recercat. Dipósit de la Recerca de Catalunya
Publication

On-skin, micro-objective enabled camera module for speckle contrast optical spectroscopy/tomography

  • Quiroga, Andres
  • Cortese, Lorenzo
  • Verma, Manish
  • Dannberg, Peter
  • Tachtsidis, Ilias
  • Danz, Norbert
  • Durduran, Turgut
In this paper, we introduce a speckle contrast optical spectroscopy/tomography (SCOS/SCOT) configuration based on an integrated imaging approach exploiting 113 microobjectives mounted on a commercial CMOS camera that operates without fiber coupling, suitable for direct skin contact measurements and simultaneous multiple source-detector separation acquisitions. This compact system was validated ex vivo on phantoms and in vivo by monitoring the blood flow on the forearm muscle of a healthy human subject. The measurements, performed at multiple source-detector separations and camera exposure times, demonstrate excellent agreement with the theory based on the correlation-diffusion model. In vivo data demonstrate the capability of tracking pulsatile blood flow with a high signal-to-noise ratio (>4 harmonics of the cardiac pulse frequency detected) and sensitivity to small changes in muscle blood flow. This micro-objective array-based design overcomes a key challenge towards wearable SCOS/SCOT devices., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Proof of concept validation of bioresorbable optical fibers for diffuse correlation spectroscopy

  • Pandayil, Jawad T.
  • Boetti, Nadia G.
  • Janner, Davide
  • Durduran, Turgut
  • Cortese, Lorenzo
Optical quality bioresorbable materials have been gaining interest in recent years for various interstitial biomedical/medical application. An example of this is when the implant gradually dissolves in the body, providing physiological information over extended periods of time, hence reducing the need for revision surgeries. This study reports for the first time the in-house fabrication of single mode (at 785 nm) calcium phosphate glass (CPG) based bioresorbable optical fibers and investigates their suitability for microvascular blood flow monitoring using diffuse correlation spectroscopy (DCS). Ex vivo experiments in liquid phantom and non-invasive in vivo experiments on the human forearm muscle were conducted using multimode and single mode CPG bioresorbable optical fibers. The retrieved flow index from the correlation curves acquired using CPG fibers was in good agreement with that obtained using standard silica (Si) fibers, both ex vivo and in vivo. The results demonstrate the potential of CPG optical fibers for further exploration., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Near-infrared diffuse optical characterization of human thyroid using ultrasound-guided hybrid time-domain and diffuse correlation spectroscopies

  • Fernández Esteberena, Pablo
  • Cortese, Lorenzo
  • Zanolotti, Marta
  • Lo Presti, Giuseppe
  • Aranda Velázquez, Gloria
  • Ruiz Janer, Sabina
  • Buttafava, Mauro
  • Renna, Marco
  • Di Sieno, Laura
  • Tosi, Alberto
  • Dalla Mora, Alberto
  • Wojtkewicz, Stanislaw
  • Dehbhani, Hamid
  • de Fraguier, Sixte
  • Nguyen-Dinh, An
  • Rosinski, Bogdan
  • Weigel, Udo M.
  • Sarangi, Dibya J.
  • Squarcia, Mattia
  • hanzu, Felicia A.
  • Contini, Davide
  • Mora Porta, Mireia
  • Durduran, Turgut
Thyroid vascularization and hemodynamics become altered in thyroid pathologies and could thus inform diagnostics, therapy planning, and follow-up. However, the current non-invasive monitoring methods available in clinics lack the necessary sensitivity and/or are impractical for large-scale deployment. As a step towards proposing a new modality, we applied the first platform, to our knowledge, designed to do simultaneous measurements of neck anatomy and thyroid microvascular hemodynamics and metabolism in a single probe placement, integrating state-of-the-art near-infrared spectroscopy techniques and clinical ultrasound. A rich dataset was formed with sixty-five subjects (forty-eight females), including eighteen healthy volunteers and forty-seven patients with thyroid nodules, characterizing thyroid tissue and the effects of demographic and anatomical variables while preserving the standard clinical workflow. We have found marked reductions with age and body mass index in thyroid total hemoglobin concentration (THC), tissue oxygen saturation (StO2), and blood flow index (BFi), among others. Patients showed lower THC and BFi than healthy subjects, and the limited sample of malignant nodules showed a higher StO2 than the benign. These findings support the need for personalized clinical approaches., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

How the heterogeneity of the severely injured brain affects hybrid 2 diffuse optical signals: case examples and guidelines

  • Tagliabue, Susanna
  • Kacprzak, Michal
  • Rey-Perez, Anna
  • Baena, Jacinto
  • Riveiro, Marilyn
  • Maruccia, Federica
  • Fischer, Jonas
  • Poca, Maria A.
  • Durduran, Turgut
Significance: A shortcoming for the routine clinical use of diffuse optics (DO) in the injured head has been that the results from commercial near-infrared spectroscopy-based devices are not reproducible, often give phys iologically invalid values and differ between systems. Besides the limitations due to the physics of continuous23 wave light sources, one culprit is the head heterogeneity and the underlying morphological and functional abnor malities of the probed tissue. Aim: To investigate the effect that different tissue alterations in the damaged head has on DO signals and provide guidelines to avoid data misinterpretation. Approach: DO measurements and computed tomography scans were acquired on brain-injured patients. The relationship between the signals and the underlying tissue types was classified on a case-by-case basis. Results: Examples and suggestions to establish quality control routines were provided. The findings suggested guidelines for carrying out DO measurements and speculations towards improved devices. Conclusions: This study advocates for the standardization of the DO measurements to secure a role for DO in neurocritical care. We suggest that blind measurements are unacceptably problematic due to confounding effects and care using a priori and a posteriori quality control routines that go beyond an assessment of the signal-to-noise ratio that is typically utilized., Preprint
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Cerebral and systemic physiological effects of wearing face masks in young adults

  • Fischer, J. B.
  • Frisk, L. K.
  • Scholkmann, F.
  • Delgado Mederos, Raquel|||0000-0003-3737-7226
  • Mayos, Merce|||0000-0003-3972-3671
  • Durduran, T.
The COVID-19 pandemic led to widespread mandates requiring the wearing of face masks, which led to debates on their benefits and possible adverse effects. To that end, the physiological effects at the systemic and at the brain level are of interest. We have investigated the effect of commonly available face masks (FFP2 and surgical) on cerebral hemodynamics and oxygenation, particularly microvascular cerebral blood flow (CBF) and blood/tissue oxygen saturation (StO), measured by transcranial hybrid near-infrared spectroscopies and on systemic physiology in 13 healthy adults (ages: 23 to 33 y). The results indicate small but significant changes in cerebral hemodynamics while wearing a mask. However, these changes are comparable to those of daily life activities. This platform and the protocol provides the basis for large or targeted studies of the effects of mask wearing in different populations and while performing critical tasks.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Transcranial optical monitoring for detecting intracranial pressure alterations in children with benign external hydrocephalus, a proof-of-concept study

  • Maruccia, Federica|||0000-0002-3774-7875
  • Tagliabue, Susanna
  • Fischer, Jonas B.|||0000-0003-4178-0261
  • Kacprzak, Michał|||0000-0002-3149-837X
  • Pérez-Hoyos, Santiago|||0000-0001-9797-4917
  • Rosas, Katiuska|||0000-0003-0375-8346
  • Delgado Alvarez, Ignacio|||0000-0001-8765-5082
  • Sahuquillo Barris, Juan|||0000-0003-0713-5875
  • Durduran, Turgut|||0000-0001-5838-1027
  • Poca Pastor, María Antonia|||0000-0002-3831-0536
Benign external hydrocephalus (BEH) is considered a self-limiting pathology with a good prognosis. However, some children present a pathological intracranial pressure (ICP) characterized by quantitative and qualitative alterations (the so-called B-waves) that can lead to neurological sequelae. Our purpose was to evaluate whether there were cerebral hemodynamic changes associated with ICP B-waves that could be evaluated with noninvasive neuromonitoring. We recruited eleven patients (median age 16 months, range 7 to 55 months) with BEH and an unfavorable evolution requiring ICP monitoring. Bedside, nocturnal monitoring using near-infrared time-resolved and diffuse correlation spectroscopies synchronized to the clinical monitoring was performed. By focusing on the timing of different ICP patterns that were identified manually by clinicians, we detected significant tissue oxygen saturation () changes () and blood flow index (BFI) variability () between regular and high-amplitude B-wave patterns. A blinded analysis looking for analogs of ICP patterns in BFI time traces achieved 90% sensitivity in identifying B-waves and 76% specificity in detecting the regular patterns. We revealed the presence of and BFI variations-detectable with optical techniques-during ICP B-waves in BEH children. Finally, the feasibility of detecting ICP B-waves in hemodynamic time traces obtained noninvasively was shown.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Comparison of cerebral metabolic rate of oxygen, blood flow, and bispectral index under general anesthesia

  • Tagliabue, Susanna
  • da Prat, Ivette Chochron
  • Sánchez Guerrero, Ángela
  • Serra Mochales, Isabel|||0000-0002-2465-8574
  • Kacprzak, Michał|||0000-0002-3149-837X
  • Maruccia, Federica|||0000-0002-3774-7875
  • Silva Martinez, Olga
  • Weigel, Udo M.
  • Nadal Clanchet, Miriam de|||0000-0002-4559-2463
  • Poca Pastor, María Antonia|||0000-0002-3831-0536
  • Durduran, Turgut|||0000-0001-5838-1027
  • Lindner, Claus|||0000-0002-9878-037X
The optical measurement of cerebral oxygen metabolism was evaluated. Compare optically derived cerebral signals to the electroencephalographic bispectral index (BIS) sensors to monitor propofol-induced anesthesia during surgery. Relative cerebral metabolic rate of oxygen () and blood flow (rCBF) were measured by time-resolved and diffuse correlation spectroscopies. Changes were tested against the relative BIS (rBIS) ones. The synchronism in the changes was also assessed by the R-Pearson correlation. In 23 measurements, optically derived signals showed significant changes in agreement with rBIS: during propofol induction, rBIS decreased by 67% [interquartile ranges (IQR) 62% to 71%], by 33% (IQR 18% to 46%), and rCBF by 28% (IQR 10% to 37%). During recovery, a significant increase was observed for rBIS (48%, IQR 38% to 55%), (29%, IQR 17% to 39%), and rCBF (30%, IQR 10% to 44%). The significance and direction of the changes subject-by-subject were tested: the coupling between the rBIS, , and rCBF was witnessed in the majority of the cases (14/18 and 12/18 for rCBF and 19/21 and 13/18 for in the initial and final part, respectively). These changes were also correlated in time (to , ). Optics can reliably monitor in such conditions.