How the heterogeneity of the severely injured brain affects hybrid diffuse optical signals, case examples and guidelines

  • Tagliabue, Susanna
  • Kacprzak, Michał|||0000-0002-3149-837X
  • Rey Pérez, Anna|||0000-0001-6014-3829
  • Baena, Jacinto
  • Riveiro, Marilyn|||0000-0002-1645-3720
  • Maruccia, Federica|||0000-0002-3774-7875
  • Fischer, Jonas B.|||0000-0003-4178-0261
  • Poca Pastor, María Antonia|||0000-0002-3831-0536
  • Durduran, Turgut|||0000-0001-5838-1027
A shortcoming of the routine clinical use of diffuse optics (DO) in the injured head has been that the results from commercial near-infrared spectroscopy-based devices are not reproducible, often give physiologically invalid values, and differ among systems. Besides the limitations due to the physics of continuous-wave light sources, one culprit is the head heterogeneity and the underlying morphological and functional abnormalities of the probed tissue. The aim is to investigate the effect that different tissue alterations in the damaged head have on DO signals and provide guidelines to avoid data misinterpretation. DO measurements and computed tomography scans were acquired on brain-injured patients. The relationship between the signals and the underlying tissue types was classified on a case-by-case basis. Examples and suggestions to establish quality control routines were provided. The findings suggested guidelines for carrying out DO measurements and speculations toward improved devices. We advocate for the standardization of the DO measurements to secure a role for DO in neurocritical care. We suggest that blind measurements are unacceptably problematic due to confounding effects and care using a priori and a posteriori quality control routines that go beyond an assessment of the signal-to-noise ratio that is typically utilized.
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Hybrid diffuse optical appraisal of peripheral and cerebral changes in critically ill patients receiving red blood cell transfusion

  • Tagliabue, Susanna
  • Rey-Perez, Anna
  • Exposito, Lourdes
  • Jimenez, Andrés F.
  • Valles Angulo, Sara
  • Maruccia, Federica
  • Fischer, Jonas
  • Kacprzak, Michal
  • Poca, Maria A.
  • Durduran, Turgut
Significance: Red blood cell transfusions (RBCTs) to restore hemoglobin concentration and hematocrit values in anemic patients are debated in critical illness. Aim: We used non-invasive hybrid diffuse optics (DO) to study RBCT’s effect on the brain and peripheral muscle evaluated in critically ill patients. Approach: Critically ill patients admitted to the neurotrauma intensive care unit of the Vall d’Hebron University Hospital that required blood transfusion were included in the study and continuously monitored by DO methods alongside time-specific blood gas samples. Results: In 14 patients, blood-derived hemoglobin, hematocrit, and DO-derived metabolic rate of oxygen, oxy- and total hemoglobin significantly increased after RBCT. Oxygen extraction fraction significantly decreased. Blood flow significantly increased only in muscles. Deoxy-hemoglobin concentration remained unchanged. No significant differences were found between cerebral and peripheral signals post-RBCT, except for the metabolic rate of oxygen (higher in muscle). Conclusion: Hybrid DO monitoring quantifies cerebral and peripheral microvascular changes during red blood cell transfusion, enabling insights into oxygen metabolism and advancing critical care management., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

How the heterogeneity of the severely injured brain affects hybrid 2 diffuse optical signals: case examples and guidelines

  • Tagliabue, Susanna
  • Kacprzak, Michal
  • Rey-Perez, Anna
  • Baena, Jacinto
  • Riveiro, Marilyn
  • Maruccia, Federica
  • Fischer, Jonas
  • Poca, Maria A.
  • Durduran, Turgut
Significance: A shortcoming for the routine clinical use of diffuse optics (DO) in the injured head has been that the results from commercial near-infrared spectroscopy-based devices are not reproducible, often give phys iologically invalid values and differ between systems. Besides the limitations due to the physics of continuous23 wave light sources, one culprit is the head heterogeneity and the underlying morphological and functional abnor malities of the probed tissue. Aim: To investigate the effect that different tissue alterations in the damaged head has on DO signals and provide guidelines to avoid data misinterpretation. Approach: DO measurements and computed tomography scans were acquired on brain-injured patients. The relationship between the signals and the underlying tissue types was classified on a case-by-case basis. Results: Examples and suggestions to establish quality control routines were provided. The findings suggested guidelines for carrying out DO measurements and speculations towards improved devices. Conclusions: This study advocates for the standardization of the DO measurements to secure a role for DO in neurocritical care. We suggest that blind measurements are unacceptably problematic due to confounding effects and care using a priori and a posteriori quality control routines that go beyond an assessment of the signal-to-noise ratio that is typically utilized.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Hybrid diffuse optical appraisal of peripheral and cerebral changes in critically ill patients receiving red blood cell transfusion

  • Tagliabue, Susanna
  • Rey-Perez, Anna
  • Exposito, Lourdes
  • Jimenez, Andrés F.
  • Valles Angulo, Sara
  • Maruccia, Federica
  • Fischer, Jonas
  • Kacprzak, Michal
  • Poca, Maria A.
  • Durduran, Turgut
Significance: Red blood cell transfusions (RBCTs) to restore hemoglobin concentration and hematocrit values in anemic patients are debated in critical illness. Aim: We used non-invasive hybrid diffuse optics (DO) to study RBCT’s effect on the brain and peripheral muscle evaluated in critically ill patients. Approach: Critically ill patients admitted to the neurotrauma intensive care unit of the Vall d’Hebron University Hospital that required blood transfusion were included in the study and continuously monitored by DO methods alongside time-specific blood gas samples. Results: In 14 patients, blood-derived hemoglobin, hematocrit, and DO-derived metabolic rate of oxygen, oxy- and total hemoglobin significantly increased after RBCT. Oxygen extraction fraction significantly decreased. Blood flow significantly increased only in muscles. Deoxy-hemoglobin concentration remained unchanged. No significant differences were found between cerebral and peripheral signals post-RBCT, except for the metabolic rate of oxygen (higher in muscle). Conclusion: Hybrid DO monitoring quantifies cerebral and peripheral microvascular changes during red blood cell transfusion, enabling insights into oxygen metabolism and advancing critical care management., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Transcranial optical monitoring for detecting intracranial pressure alterations in children with benign external hydrocephalus: a proof-of-concept study

  • Tagliabue, Susanna
  • Fischer, Jonas B.
  • Perez Hoyos, Santi
  • Rosas Soto, Katiuska
  • Sahuquillo Barris, Joan
  • Durduran, Turgut
  • Poca Pastor, Ma Antonia
  • Delgado Alvarez, Ignacio
  • Kacprzak, Michał
  • Maruccia, Federica
Hydrocephalus; Optical techniques; Pathophysiology, Hidrocefalia; Técnicas ópticas; Fisiopatología, Hidrocefàlia; Tècniques òptiques; Fisiopatologia, Significance Benign external hydrocephalus (BEH) is considered a self-limiting pathology with a good prognosis. However, some children present a pathological intracranial pressure (ICP) characterized by quantitative and qualitative alterations (the so-called B-waves) that can lead to neurological sequelae. Aim Our purpose was to evaluate whether there were cerebral hemodynamic changes associated with ICP B-waves that could be evaluated with noninvasive neuromonitoring. Approach We recruited eleven patients (median age 16 months, range 7 to 55 months) with BEH and an unfavorable evolution requiring ICP monitoring. Bedside, nocturnal monitoring using near-infrared time-resolved and diffuse correlation spectroscopies synchronized to the clinical monitoring was performed. Results By focusing on the timing of different ICP patterns that were identified manually by clinicians, we detected significant tissue oxygen saturation (StO2) changes (p = 0.002) and blood flow index (BFI) variability (p = 0.005) between regular and high-amplitude B-wave patterns. A blinded analysis looking for analogs of ICP patterns in BFI time traces achieved 90% sensitivity in identifying B-waves and 76% specificity in detecting the regular patterns. Conclusions We revealed the presence of StO2 and BFI variations—detectable with optical techniques—during ICP B-waves in BEH children. Finally, the feasibility of detecting ICP B-waves in hemodynamic time traces obtained noninvasively was shown., This work was realized with the support of the Department of Cirugía and Ciencias Morfológicas of the Universitat Autònoma de Barcelona. The work was supported by the European Union’s Horizon 2020 Research and Innovation Program under the Marie Sklodowska-Curie (Grant No. 675332) (BitMap: brain injury and trauma monitoring using advanced photonics) and the European Union’s Horizon 2020 Research and Innovation Program [Grant No. 101017113 (TinyBrains) and Grant No. 101016087 (VASCOVID)]; Fondo de Investigación Sanitaria (Instituto de Salud Carlos III) (Grant No. PI18/00468); Fundació CELLEX Barcelona, Fundació Mir Puig, Agencia Estatal de Investigación (PHOTOMETABO, Grant No. PID2019106481RBC31); the “Severo Ochoa” Program for Centers of Excelence in R&D (Grant No. CEX2019-000910-S); the Obra social “La Caixa” Foundation (LlumMedBcn), Generalitat de Catalunya (CERCA, AGAUR-2017-SGR-1380, RIS3CAT-001-P-001682 CECH), FEDER EC and LASERLAB EUROPE V (EC H2020 No. 871124); KidsBrainIT (ERANET NEURON); Fundació La Marató de TV3 (Grant Nos. 201724.31 and 201709.31).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

How the heterogeneity of the severely injured brain affects hybrid diffuse optical signals: case examples and guidelines

  • Tagliabue, Susanna
  • Kacprzak, Michał
  • Rey Perez, Anna
  • Baena Caparros, Jacinto
  • Riveiro, Marilyn
  • Maruccia, Federica
  • Poca, Maria A.
Atypical tissue effect; Data quality control; Hybrid diffuse optics, Efecto tisular atípico; Control de calidad de datos; Óptica difusa híbrida, Efecte tissular atípic; Control de qualitat de dades; Òptica difusa híbrida, Significance A shortcoming of the routine clinical use of diffuse optics (DO) in the injured head has been that the results from commercial near-infrared spectroscopy-based devices are not reproducible, often give physiologically invalid values, and differ among systems. Besides the limitations due to the physics of continuous-wave light sources, one culprit is the head heterogeneity and the underlying morphological and functional abnormalities of the probed tissue. Aim The aim is to investigate the effect that different tissue alterations in the damaged head have on DO signals and provide guidelines to avoid data misinterpretation. Approach DO measurements and computed tomography scans were acquired on brain-injured patients. The relationship between the signals and the underlying tissue types was classified on a case-by-case basis. Results Examples and suggestions to establish quality control routines were provided. The findings suggested guidelines for carrying out DO measurements and speculations toward improved devices. Conclusions We advocate for the standardization of the DO measurements to secure a role for DO in neurocritical care. We suggest that blind measurements are unacceptably problematic due to confounding effects and care using a priori and a posteriori quality control routines that go beyond an assessment of the signal-to-noise ratio that is typically utilized., This research was funded by the European Union’s Horizon 2020 research and innovation programme under grant agreements No. 675332 (BitMap), No. 101016087 (VASCOVID) and No. 101017113 (TinyBRAINS). Moreover, this work was funded by: Fundació CELLEX Barcelona, Fundació Mir-Puig, Agencia Estatal de Investigación (PHOTOMETABO, PID2019-106481RBC31/10.13039/501100011033), the “Severo Ochoa” Programme for Centres of Excellence in R&D (CEX2019-000910-S); LUX4MED and MEDLUX special programs; Generalitat de Catalunya (CERCA, AGAUR-2017-SGR-1380, RIS3CAT-001-P-001682 CECH, and AGAUR-2021SGR/00810), FEDER EC and LASERLAB-EUROPE V (EC H2020 no. 871124), KidsBrainIT (ERA-NET NEURON), la Fundació La Marató de TV3 (201724.31, 201709.31 and 202109-30), “PLEC2022-009290, SafeICP” project funded by MCIN/AEI/10.13039/501100011033 and by the “European Union NextGenerationEU/PRTR.” The study was partially financed by the National Science Centre of Poland (NCN) in the framework of project 2019/33/B/ST7/01387
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Comparison of cerebral metabolic rate of oxygen, blood flow, and bispectral index under general anesthesia

  • Tagliabue, Susanna
  • Lindner, Claus
  • Chochron da Prat, Ivette
  • Sánchez Guerrero, Ángela
  • Serra, Isabel
  • Martínez Silva, Olga
  • Nadal Clanchet, Miriam de
  • Poca Pastor, Ma Antonia
  • Kacprzak, Michał
  • Maruccia, Federica
Cerebral blood flow; Diffuse optics; Propofol-induced anesthesia, Flujo sanguíneo cerebral; Óptica difusa; Anestesia inducida por propofol, Flux sanguini cerebral; Òptica difusa; Anestèsia induïda per propofol, Significance The optical measurement of cerebral oxygen metabolism was evaluated. Aim Compare optically derived cerebral signals to the electroencephalographic bispectral index (BIS) sensors to monitor propofol-induced anesthesia during surgery. Approach Relative cerebral metabolic rate of oxygen (rCMRO2) and blood flow (rCBF) were measured by time-resolved and diffuse correlation spectroscopies. Changes were tested against the relative BIS (rBIS) ones. The synchronism in the changes was also assessed by the R-Pearson correlation. Results In 23 measurements, optically derived signals showed significant changes in agreement with rBIS: during propofol induction, rBIS decreased by 67% [interquartile ranges (IQR) 62% to 71%], rCMRO2 by 33% (IQR 18% to 46%), and rCBF by 28% (IQR 10% to 37%). During recovery, a significant increase was observed for rBIS (48%, IQR 38% to 55%), rCMRO2 (29%, IQR 17% to 39%), and rCBF (30%, IQR 10% to 44%). The significance and direction of the changes subject-by-subject were tested: the coupling between the rBIS, rCMRO2, and rCBF was witnessed in the majority of the cases (14/18 and 12/18 for rCBF and 19/21 and 13/18 for rCMRO2 in the initial and final part, respectively). These changes were also correlated in time (R > 0.69 to R = 1, p-values < 0.05). Conclusions Optics can reliably monitor rCMRO2 in such conditions., This work received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 675332 (BitMap), No. 101016087 (VASCOVID) and No. 101017113 (TinyBRAINS), KidsBrainIT (ERA-NET NEURON), FEDER EC and LASERLAB-EUROPE V (EC H2020 no. 871124). It was also supported by Fundació CELLEX Barcelona, Fundació Mir-Puig the “Severo Ochoa” Programme for Centres of Excellence in R&D (SEV-2015-0522), the Obra social “la Caixa” Foundation (LlumMedBcn), Generalitat de Catalunya (CERCA, AGAUR-2017-SGR-1380, RIS3CAT-001-P-001682 CECH), la Fundació La Marató de TV3 (201724.31 and 201709.31), and by Agencia Estatal de Investigación (PHOTOMETABO, PID2019-106481RB-C31/10.13039/501100011033).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

How to Choose a Shunt for Patients with Normal Pressure Hydrocephalus: A Short Guide to Selecting the Best Shunt Assembly

  • Sahuquillo Barris, Joan
  • Rosas Soto, Katiuska
  • Calvo Rubio Jimenez, Helena
  • Alcina Albors, Aloma
  • Gándara Sabatini, Dario Fabian
  • Lopez-Bermeo, Diego
  • Poca Pastor, Ma Antonia
Válvulas de presión diferencial; Mecánica de fluidos; Hidrocefalia, Differential-pressure valves; Fluid mechanics; Hydrocephalus, Vàlvules de pressió diferencial; Mecànica de fluids; Hidrocefàlia, Most patients with hydrocephalus are still managed with the implantation of a cerebrospinal fluid (CSF) shunt in which the CSF flow is regulated by a differential-pressure valve (DPV). Our aim in this review is to discuss some basic concepts in fluid mechanics that are frequently ignored but that should be understood by neurosurgeons to enable them to choose the most adequate shunt for each patient. We will present data, some of which is not provided by manufacturers, which may help neurosurgeons in selecting the most appropriate shunt. To do so, we focused on the management of patients with idiopathic “normal-pressure hydrocephalus” (iNPH), as one of the most challenging scenarios, in which the combination of optimal technology, patient characteristics, and knowledge of fluid mechanics can significantly modify the surgical results. For a better understanding of the available hardware and its evolution over time, we will have a second look at the design of the first DPV and the reasons why additional devices were incorporated to control for shunt overdrainage and its related complications. We try to persuade the reader that a clear understanding of the physical concepts of the CSF and shunt dynamics is key to understand the pathophysiology of iNPH and to improve its treatment., This work has been supported by the European Union’s Horizon 2020 research and innovation program under the Marie Sklodowska-Curie grant agreement No. 675332; Fondo de Investigación Sanitaria (Instituto de Salud Carlos III) grant PI18/00468 and DTS16/00087, cofinanced by the European Regional Development (ERDF); Ministerio de Economía y Competitividad/FEDER (PHOTODEMENTIA, DPI2015-64358-C2-1-R).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

How the heterogeneity of the severely injured brain affects hybrid 2 diffuse optical signals: case examples and guidelines

  • Tagliabue, Susanna
  • Kacprzak, Michal
  • Rey-Perez, Anna
  • Baena, Jacinto
  • Riveiro, Marilyn
  • Maruccia, Federica
  • Fischer, Jonas
  • Poca, Maria A.
  • Durduran, Turgut
Significance: A shortcoming for the routine clinical use of diffuse optics (DO) in the injured head has been that the results from commercial near-infrared spectroscopy-based devices are not reproducible, often give phys iologically invalid values and differ between systems. Besides the limitations due to the physics of continuous23 wave light sources, one culprit is the head heterogeneity and the underlying morphological and functional abnor malities of the probed tissue. Aim: To investigate the effect that different tissue alterations in the damaged head has on DO signals and provide guidelines to avoid data misinterpretation. Approach: DO measurements and computed tomography scans were acquired on brain-injured patients. The relationship between the signals and the underlying tissue types was classified on a case-by-case basis. Results: Examples and suggestions to establish quality control routines were provided. The findings suggested guidelines for carrying out DO measurements and speculations towards improved devices. Conclusions: This study advocates for the standardization of the DO measurements to secure a role for DO in neurocritical care. We suggest that blind measurements are unacceptably problematic due to confounding effects and care using a priori and a posteriori quality control routines that go beyond an assessment of the signal-to-noise ratio that is typically utilized., Preprint
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Neurodevelopmental profile in children with benign external hydrocephalus syndrome. A pilot cohort study

  • Maruccia, Federica|||0000-0002-3774-7875
  • Gomariz, Laura
  • Rosas, Katiuska|||0000-0003-0375-8346
  • Durduran, Turgut|||0000-0001-5838-1027
  • Paredes Carmona, Fernando
  • Sahuquillo Barris, Juan|||0000-0003-0713-5875
  • Poca Pastor, María Antonia|||0000-0002-3831-0536
Purpose The management of children with benign external hydrocephalus (BEH) remains controversial. Most BEH children do well in the long-term, but a substantial number have temporary or permanent psychomotor delays. The study aims to assess the prevalence and pattern of neurodevelopmental delay in a cohort of children with BEH. Methods We conducted a cohort study of 42 BEH children (30 boys and 12 girls, aged 6 to 38 months). A pediatric neurosurgeon performed a first clinical evaluation to confirm/reject the diagnosis according to the clinical features and neuroimaging studies. Two trained evaluators assessed the child's psychomotor development using the third edition of the Bayley Scales of Infant and Toddler Development (Bayley-III). Developmental delay was defined as a scaled score < 7 according to the simple scale and/or a composite score < 85. Results Eighteen children (43%) presented statistically lower scores in the gross motor and composite motor of the Bayley-III scales compared to their healthy peers. Conclusion In BEH, it is important to establish a diagnostic algorithm that helps to discriminate BEH patients that have selflimiting delays from those at risk of a persistent delay that should be referred for additional studies and/or interventions that might improve the natural evolution of a disease with high impact on the children and adult's quality of life.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Cerebral and systemic physiological effects of wearing face masks in young adults

  • Fischer, J. B.
  • Frisk, L. K.
  • Scholkmann, F.
  • Delgado Mederos, Raquel|||0000-0003-3737-7226
  • Mayos, Merce|||0000-0003-3972-3671
  • Durduran, T.
The COVID-19 pandemic led to widespread mandates requiring the wearing of face masks, which led to debates on their benefits and possible adverse effects. To that end, the physiological effects at the systemic and at the brain level are of interest. We have investigated the effect of commonly available face masks (FFP2 and surgical) on cerebral hemodynamics and oxygenation, particularly microvascular cerebral blood flow (CBF) and blood/tissue oxygen saturation (StO), measured by transcranial hybrid near-infrared spectroscopies and on systemic physiology in 13 healthy adults (ages: 23 to 33 y). The results indicate small but significant changes in cerebral hemodynamics while wearing a mask. However, these changes are comparable to those of daily life activities. This platform and the protocol provides the basis for large or targeted studies of the effects of mask wearing in different populations and while performing critical tasks.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Transcranial optical monitoring for detecting intracranial pressure alterations in children with benign external hydrocephalus, a proof-of-concept study

  • Maruccia, Federica|||0000-0002-3774-7875
  • Tagliabue, Susanna
  • Fischer, Jonas B.|||0000-0003-4178-0261
  • Kacprzak, Michał|||0000-0002-3149-837X
  • Pérez-Hoyos, Santiago|||0000-0001-9797-4917
  • Rosas, Katiuska|||0000-0003-0375-8346
  • Delgado Alvarez, Ignacio|||0000-0001-8765-5082
  • Sahuquillo Barris, Juan|||0000-0003-0713-5875
  • Durduran, Turgut|||0000-0001-5838-1027
  • Poca Pastor, María Antonia|||0000-0002-3831-0536
Benign external hydrocephalus (BEH) is considered a self-limiting pathology with a good prognosis. However, some children present a pathological intracranial pressure (ICP) characterized by quantitative and qualitative alterations (the so-called B-waves) that can lead to neurological sequelae. Our purpose was to evaluate whether there were cerebral hemodynamic changes associated with ICP B-waves that could be evaluated with noninvasive neuromonitoring. We recruited eleven patients (median age 16 months, range 7 to 55 months) with BEH and an unfavorable evolution requiring ICP monitoring. Bedside, nocturnal monitoring using near-infrared time-resolved and diffuse correlation spectroscopies synchronized to the clinical monitoring was performed. By focusing on the timing of different ICP patterns that were identified manually by clinicians, we detected significant tissue oxygen saturation () changes () and blood flow index (BFI) variability () between regular and high-amplitude B-wave patterns. A blinded analysis looking for analogs of ICP patterns in BFI time traces achieved 90% sensitivity in identifying B-waves and 76% specificity in detecting the regular patterns. We revealed the presence of and BFI variations-detectable with optical techniques-during ICP B-waves in BEH children. Finally, the feasibility of detecting ICP B-waves in hemodynamic time traces obtained noninvasively was shown.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Comparison of cerebral metabolic rate of oxygen, blood flow, and bispectral index under general anesthesia

  • Tagliabue, Susanna
  • da Prat, Ivette Chochron
  • Sánchez Guerrero, Ángela
  • Serra Mochales, Isabel|||0000-0002-2465-8574
  • Kacprzak, Michał|||0000-0002-3149-837X
  • Maruccia, Federica|||0000-0002-3774-7875
  • Silva Martinez, Olga
  • Weigel, Udo M.
  • Nadal Clanchet, Miriam de|||0000-0002-4559-2463
  • Poca Pastor, María Antonia|||0000-0002-3831-0536
  • Durduran, Turgut|||0000-0001-5838-1027
  • Lindner, Claus|||0000-0002-9878-037X
The optical measurement of cerebral oxygen metabolism was evaluated. Compare optically derived cerebral signals to the electroencephalographic bispectral index (BIS) sensors to monitor propofol-induced anesthesia during surgery. Relative cerebral metabolic rate of oxygen () and blood flow (rCBF) were measured by time-resolved and diffuse correlation spectroscopies. Changes were tested against the relative BIS (rBIS) ones. The synchronism in the changes was also assessed by the R-Pearson correlation. In 23 measurements, optically derived signals showed significant changes in agreement with rBIS: during propofol induction, rBIS decreased by 67% [interquartile ranges (IQR) 62% to 71%], by 33% (IQR 18% to 46%), and rCBF by 28% (IQR 10% to 37%). During recovery, a significant increase was observed for rBIS (48%, IQR 38% to 55%), (29%, IQR 17% to 39%), and rCBF (30%, IQR 10% to 44%). The significance and direction of the changes subject-by-subject were tested: the coupling between the rBIS, , and rCBF was witnessed in the majority of the cases (14/18 and 12/18 for rCBF and 19/21 and 13/18 for in the initial and final part, respectively). These changes were also correlated in time (to , ). Optics can reliably monitor in such conditions.
Scientia. Dipòsit d'Informació Digital del Departament de Salut
Publication Artículo científico (JournalArticle)

How to Choose a Shunt for Patients with Normal Pressure Hydrocephalus: A Short Guide to Selecting the Best Shunt Assembly

  • Sahuquillo Barris, Joan
  • Rosas Soto, Katiuska
  • Calvo Rubio Jimenez, Helena
  • Alcina Albors, Aloma
  • Gándara Sabatini, Dario Fabian
  • Lopez-Bermeo, Diego
  • Poca Pastor, Ma Antonia
Válvulas de presión diferencial; Mecánica de fluidos; Hidrocefalia, Differential-pressure valves; Fluid mechanics; Hydrocephalus, Vàlvules de pressió diferencial; Mecànica de fluids; Hidrocefàlia, Most patients with hydrocephalus are still managed with the implantation of a cerebrospinal fluid (CSF) shunt in which the CSF flow is regulated by a differential-pressure valve (DPV). Our aim in this review is to discuss some basic concepts in fluid mechanics that are frequently ignored but that should be understood by neurosurgeons to enable them to choose the most adequate shunt for each patient. We will present data, some of which is not provided by manufacturers, which may help neurosurgeons in selecting the most appropriate shunt. To do so, we focused on the management of patients with idiopathic “normal-pressure hydrocephalus” (iNPH), as one of the most challenging scenarios, in which the combination of optimal technology, patient characteristics, and knowledge of fluid mechanics can significantly modify the surgical results. For a better understanding of the available hardware and its evolution over time, we will have a second look at the design of the first DPV and the reasons why additional devices were incorporated to control for shunt overdrainage and its related complications. We try to persuade the reader that a clear understanding of the physical concepts of the CSF and shunt dynamics is key to understand the pathophysiology of iNPH and to improve its treatment., This work has been supported by the European Union’s Horizon 2020 research and innovation program under the Marie Sklodowska-Curie grant agreement No. 675332; Fondo de Investigación Sanitaria (Instituto de Salud Carlos III) grant PI18/00468 and DTS16/00087, cofinanced by the European Regional Development (ERDF); Ministerio de Economía y Competitividad/FEDER (PHOTODEMENTIA, DPI2015-64358-C2-1-R).
Scientia. Dipòsit d'Informació Digital del Departament de Salut
Publication Artículo científico (JournalArticle)

Comparison of cerebral metabolic rate of oxygen, blood flow, and bispectral index under general anesthesia

  • Tagliabue, Susanna
  • Lindner, Claus
  • Chochron da Prat, Ivette
  • Sánchez Guerrero, Ángela
  • Serra, Isabel
  • Martínez Silva, Olga
  • Nadal Clanchet, Miriam de
  • Poca Pastor, Ma Antonia
  • Kacprzak, Michał
  • Maruccia, Federica
Cerebral blood flow; Diffuse optics; Propofol-induced anesthesia, Flujo sanguíneo cerebral; Óptica difusa; Anestesia inducida por propofol, Flux sanguini cerebral; Òptica difusa; Anestèsia induïda per propofol, Significance The optical measurement of cerebral oxygen metabolism was evaluated. Aim Compare optically derived cerebral signals to the electroencephalographic bispectral index (BIS) sensors to monitor propofol-induced anesthesia during surgery. Approach Relative cerebral metabolic rate of oxygen (rCMRO2) and blood flow (rCBF) were measured by time-resolved and diffuse correlation spectroscopies. Changes were tested against the relative BIS (rBIS) ones. The synchronism in the changes was also assessed by the R-Pearson correlation. Results In 23 measurements, optically derived signals showed significant changes in agreement with rBIS: during propofol induction, rBIS decreased by 67% [interquartile ranges (IQR) 62% to 71%], rCMRO2 by 33% (IQR 18% to 46%), and rCBF by 28% (IQR 10% to 37%). During recovery, a significant increase was observed for rBIS (48%, IQR 38% to 55%), rCMRO2 (29%, IQR 17% to 39%), and rCBF (30%, IQR 10% to 44%). The significance and direction of the changes subject-by-subject were tested: the coupling between the rBIS, rCMRO2, and rCBF was witnessed in the majority of the cases (14/18 and 12/18 for rCBF and 19/21 and 13/18 for rCMRO2 in the initial and final part, respectively). These changes were also correlated in time (R > 0.69 to R = 1, p-values < 0.05). Conclusions Optics can reliably monitor rCMRO2 in such conditions., This work received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 675332 (BitMap), No. 101016087 (VASCOVID) and No. 101017113 (TinyBRAINS), KidsBrainIT (ERA-NET NEURON), FEDER EC and LASERLAB-EUROPE V (EC H2020 no. 871124). It was also supported by Fundació CELLEX Barcelona, Fundació Mir-Puig the “Severo Ochoa” Programme for Centres of Excellence in R&D (SEV-2015-0522), the Obra social “la Caixa” Foundation (LlumMedBcn), Generalitat de Catalunya (CERCA, AGAUR-2017-SGR-1380, RIS3CAT-001-P-001682 CECH), la Fundació La Marató de TV3 (201724.31 and 201709.31), and by Agencia Estatal de Investigación (PHOTOMETABO, PID2019-106481RB-C31/10.13039/501100011033).
Scientia. Dipòsit d'Informació Digital del Departament de Salut
Publication Artículo científico (JournalArticle)

Transcranial optical monitoring for detecting intracranial pressure alterations in children with benign external hydrocephalus: a proof-of-concept study

  • Tagliabue, Susanna
  • Fischer, Jonas B.
  • Perez Hoyos, Santi
  • Rosas Soto, Katiuska
  • Sahuquillo Barris, Joan
  • Durduran, Turgut
  • Poca Pastor, Ma Antonia
  • Delgado Alvarez, Ignacio
  • Kacprzak, Michał
  • Maruccia, Federica
Hydrocephalus; Optical techniques; Pathophysiology, Hidrocefalia; Técnicas ópticas; Fisiopatología, Hidrocefàlia; Tècniques òptiques; Fisiopatologia, Significance Benign external hydrocephalus (BEH) is considered a self-limiting pathology with a good prognosis. However, some children present a pathological intracranial pressure (ICP) characterized by quantitative and qualitative alterations (the so-called B-waves) that can lead to neurological sequelae. Aim Our purpose was to evaluate whether there were cerebral hemodynamic changes associated with ICP B-waves that could be evaluated with noninvasive neuromonitoring. Approach We recruited eleven patients (median age 16 months, range 7 to 55 months) with BEH and an unfavorable evolution requiring ICP monitoring. Bedside, nocturnal monitoring using near-infrared time-resolved and diffuse correlation spectroscopies synchronized to the clinical monitoring was performed. Results By focusing on the timing of different ICP patterns that were identified manually by clinicians, we detected significant tissue oxygen saturation (StO2) changes (p = 0.002) and blood flow index (BFI) variability (p = 0.005) between regular and high-amplitude B-wave patterns. A blinded analysis looking for analogs of ICP patterns in BFI time traces achieved 90% sensitivity in identifying B-waves and 76% specificity in detecting the regular patterns. Conclusions We revealed the presence of StO2 and BFI variations—detectable with optical techniques—during ICP B-waves in BEH children. Finally, the feasibility of detecting ICP B-waves in hemodynamic time traces obtained noninvasively was shown., This work was realized with the support of the Department of Cirugía and Ciencias Morfológicas of the Universitat Autònoma de Barcelona. The work was supported by the European Union’s Horizon 2020 Research and Innovation Program under the Marie Sklodowska-Curie (Grant No. 675332) (BitMap: brain injury and trauma monitoring using advanced photonics) and the European Union’s Horizon 2020 Research and Innovation Program [Grant No. 101017113 (TinyBrains) and Grant No. 101016087 (VASCOVID)]; Fondo de Investigación Sanitaria (Instituto de Salud Carlos III) (Grant No. PI18/00468); Fundació CELLEX Barcelona, Fundació Mir Puig, Agencia Estatal de Investigación (PHOTOMETABO, Grant No. PID2019106481RBC31); the “Severo Ochoa” Program for Centers of Excelence in R&D (Grant No. CEX2019-000910-S); the Obra social “La Caixa” Foundation (LlumMedBcn), Generalitat de Catalunya (CERCA, AGAUR-2017-SGR-1380, RIS3CAT-001-P-001682 CECH), FEDER EC and LASERLAB EUROPE V (EC H2020 No. 871124); KidsBrainIT (ERANET NEURON); Fundació La Marató de TV3 (Grant Nos. 201724.31 and 201709.31).
Scientia. Dipòsit d'Informació Digital del Departament de Salut
Publication Artículo científico (JournalArticle)

How the heterogeneity of the severely injured brain affects hybrid diffuse optical signals: case examples and guidelines

  • Tagliabue, Susanna
  • Kacprzak, Michał
  • Rey Perez, Anna
  • Baena Caparros, Jacinto
  • Riveiro, Marilyn
  • Maruccia, Federica
  • Poca, Maria A.
Atypical tissue effect; Data quality control; Hybrid diffuse optics, Efecto tisular atípico; Control de calidad de datos; Óptica difusa híbrida, Efecte tissular atípic; Control de qualitat de dades; Òptica difusa híbrida, Significance A shortcoming of the routine clinical use of diffuse optics (DO) in the injured head has been that the results from commercial near-infrared spectroscopy-based devices are not reproducible, often give physiologically invalid values, and differ among systems. Besides the limitations due to the physics of continuous-wave light sources, one culprit is the head heterogeneity and the underlying morphological and functional abnormalities of the probed tissue. Aim The aim is to investigate the effect that different tissue alterations in the damaged head have on DO signals and provide guidelines to avoid data misinterpretation. Approach DO measurements and computed tomography scans were acquired on brain-injured patients. The relationship between the signals and the underlying tissue types was classified on a case-by-case basis. Results Examples and suggestions to establish quality control routines were provided. The findings suggested guidelines for carrying out DO measurements and speculations toward improved devices. Conclusions We advocate for the standardization of the DO measurements to secure a role for DO in neurocritical care. We suggest that blind measurements are unacceptably problematic due to confounding effects and care using a priori and a posteriori quality control routines that go beyond an assessment of the signal-to-noise ratio that is typically utilized., This research was funded by the European Union’s Horizon 2020 research and innovation programme under grant agreements No. 675332 (BitMap), No. 101016087 (VASCOVID) and No. 101017113 (TinyBRAINS). Moreover, this work was funded by: Fundació CELLEX Barcelona, Fundació Mir-Puig, Agencia Estatal de Investigación (PHOTOMETABO, PID2019-106481RBC31/10.13039/501100011033), the “Severo Ochoa” Programme for Centres of Excellence in R&D (CEX2019-000910-S); LUX4MED and MEDLUX special programs; Generalitat de Catalunya (CERCA, AGAUR-2017-SGR-1380, RIS3CAT-001-P-001682 CECH, and AGAUR-2021SGR/00810), FEDER EC and LASERLAB-EUROPE V (EC H2020 no. 871124), KidsBrainIT (ERA-NET NEURON), la Fundació La Marató de TV3 (201724.31, 201709.31 and 202109-30), “PLEC2022-009290, SafeICP” project funded by MCIN/AEI/10.13039/501100011033 and by the “European Union NextGenerationEU/PRTR.” The study was partially financed by the National Science Centre of Poland (NCN) in the framework of project 2019/33/B/ST7/01387