Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Carbon nanotube-based nanocomposite sensor tuned with a catechol as novel electrochemical recognition platform of uranyl ion in aqueous samples

  • Muñoz, Jose|||0000-0001-9529-6980
  • Montes, Raquel|||0000-0001-8805-9987
  • Bastos Arrieta, Julio|||0000-0002-8939-6253
  • Guardingo Melián, Mireia
  • Busqué, Félix|||0000-0001-7566-4264
  • Ruiz-Molina, Daniel|||0000-0002-6844-8421
  • Palet, Cristina|||0000-0002-7467-613X
  • García Orellana, Jordi|||0000-0002-0543-2641
  • Baeza, Mireia|||0000-0002-2240-6410
This article reports a novel electrochemical recognition platform based on a nanocomposite carbon paste electrode containing carbon nanotubes modified with gold nanoparticles carrying a thiolated catechol for the fast amperometric determination of uranyl ion (UO ) in water. Recognition of UO is accomplished by supramolecular chemistry due to the formation of an inclusion complex between catechol and UO . The amperometric device operates at -0.40 V vs. Ag/AgCl, where the reduction of UO takes place on the electrode surface, covering a linear range from 0.49 to 170 μg L UO in a 0.1 M boric acid buffer solution at pH 5.3. The developed sensing system presents good response towards UO in aqueous environmental samples, with good selectivity over other browsed cations and can be easily reset by simple polishing. This platform has demonstrated to be a potential alternative regarding to the common standard bench-top analytical techniques for the development of in-field devices for in-situ monitoring.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Comparing nucleic acid lateral flow and electrochemical genosensing for the simultaneous detection of foodborne pathogens

  • Ben Aissa Soler, Alejandra|||0000-0002-0419-0572
  • Jara, José Juan
  • Sebastián, Rosa María|||0000-0001-5519-9131
  • Vallribera, Adelina|||0000-0002-6452-4589
  • Campoy Sánchez, Susana|||0000-0003-1369-0197
  • Pividori, María Isabel|||0000-0002-5266-7873
Due to the increasing need of rapid tests for application in low resource settings, WHO summarized their ideal features under the acronym ASSURED (Affordable, Sensitive, Specific, User-friendly, Rapid and Robust, Equipment-free, Delivered to those who need it). In this work, two different platforms for the rapid and simultaneous testing of the foodborne pathogens E. coli O157:H7 and Salmonella enterica, in detail a nucleic acid lateral flow and an electrochemical magneto-genosensor are presented and compared in terms of their analytical performance. The DNA of the bacteria was amplified by polymerase chain reaction using a quadruple-tagging set of primers specific for E. coli eaeA (151 bp) and Salmonella enterica yfiR (375 bp) genes. During the amplification, the amplicons were labelled at the same time with biotin/digoxigenin or biotin/fluorescein tags, respectively. The nucleic acid lateral flow assay was based on the use of streptavidin gold nanoparticles for the labelling of the tagged amplicon from E. coli and Salmonella. The visual readout was achieved when the gold-modified amplicons were captured by the specific antibodies. The features of this approach are discussed and compared with an electrochemical magneto-genosensor. Although nucleic acid lateral flow showed higher limit of detection, this strategy was able to clearly distinguish positive and negative samples of both bacteria being considered as a rapid and promising detection tool for bacteria screening.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Low cost and compact analytical microsystem for carbon dioxide determination in production processes of wine and beer

  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Ymbern Llorens, Oriol|||0000-0003-1997-6794
  • Izquierdo, David|||0000-0002-4746-3139
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
The design, construction and evaluation of a low cost, cyclic olefin copolymer (COC)-based continuous flow microanalyzer, with optical detection, to monitor carbon dioxide in bottled wines and beers as well as in fermentation processes, is presented. The microsystem, constructed by computer numerically controlled (CNC) micromilling and using a multilayer approach, integrates microfluidics, gas-diffusion module and an optical flow-cell in a single polymeric substrate. Its size is slightly bigger than a credit card, exactly 45 × 60 × 4 mm in the microfluidic and diffusion module zone and 22.5 × 40 × 3 mm in the flow-cell zone. The gas-diffusion module is based on a hydrophobic polyvinylidene fluoride (PVDF) membrane, which allows the transfer of the carbon dioxide present in the sample to a bromothymol blue (BTB) pH-sensitive acceptor solution, where the color change is measured optically. The detection system consisted of a LED with an emission peak at 607 nm and a photodiode integrated in a printed circuit board (PCB). The obtained analytical features after the optimization of the microfluidic platform and hydrodynamic variables are a linear range from 255 to 10000 mg L-1 of CO2 and a detection limit of 83 mg L-1 with a sampling rate of 30 samples h-1.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Versatile lock and key assembly for optical measurements with microfluidic platforms and cartridges

  • Ymbern Llorens, Oriol|||0000-0003-1997-6794
  • Berenguel-Alonso, Miguel|||0000-0002-3759-3634
  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Gómez-de Pedro, Sara|||0000-0002-3794-5820
  • Izquierdo, David|||0000-0002-4746-3139
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
A novel and versatile optical reader for microfluidic platforms is presented. The reader includes a modular insertion port based on the lock and key concept for reproducible alignment with a miniaturized optical detection system comprising an interchangeable light emitting diode (LED) and a photodiode. The modular nature of the insertion port allows the use of microfluidic platforms in variable shapes and fluidic configurations. Three different analytical methodologies based on absorbance or fluorescence measurements were used to demonstrate the flexibility and reproducibility of the proposed experimental setup.