Skip to main content

MINIATURIZACION, INTEGRACION Y PARALELIZACION DE ENSAYOS QUIMICOS Y BIOLOGICOS MEDIANTE NUEVAS PLATAFORMAS DE MICROFLUIDICA

CTQ2012-36165

•
Funding agency name Ministerio de Economía y Competitividad
Funding agency acronym MINECO
Program Programa Nacional de Proyectos de Investigación Fundamental
Subprogram Subprograma de Proyectos de Investigación Fundamental no Orientada
Call Proyectos I+D
Call year 2012
State Plan 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Management unit Secretaría de Estado de Investigación, Desarrollo e Innovación
Beneficiary centre UNIVERSIDAD AUTONOMA DE BARCELONA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 10
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

An LTCC monolithic microreactor for the synthesis of carbon dots with photoluminescence imaging of the reaction progress

  • Berenguel-Alonso, Miguel|||0000-0002-3759-3634
  • Ortiz-Gómez, Inmaculada|||0000-0003-4677-2383
  • Fernández, Belén|||0000-0001-9987-1495
  • Couceiro, Pedro|||0000-0001-5539-2441
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
  • Capitan-Vallvey, Luis Fermín|||0000-0002-7112-3601
  • Salinas-Castillo, Alfonso|||0000-0002-1360-6699
  • Puyol, Mar|||0000-0002-9274-2284
This work describes the development of a fully integrated Low Temperature Co-fired Ceramic (LTCC)microreactor for the synthesis of carbon dots (CDots). The microreactor integrates fluidics, a heating resistor and an optical window for fluorescence imaging of the reaction progress in a monolithic, all ceramic device, ensuring homogeneous surface chemistry and physical properties. A pool of different CDots was synthesized at high temperature and pressure using a hydrothermal method, demonstrating the robustness of the microreactor. The synthesis was monitored by following the photoluminescence of the produced CDots, and the reaction conditions were optimized according to their Quantum Yield (QY)and the flow pattern inside the microchannel. The obtained CDots exhibited blue photoluminescence upon irradiation with UV light with QYs of up to 0.77. The CDots were screened as metal nanoprobes and bioimaging contrast agents.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Optical microfluidic system based on ionophore modified gold nanoparticles for the continuous monitoring of mercuric ion

  • Gómez-De Pedro, S.
  • Lopes, D.
  • Miltsov, S.
  • Izquierdo, D.
  • Alonso-Chamarro, J.
  • Puyol, M.
An optical microfluidic system based on the use of modified gold nanoparticles for monitoring Hg(II) is presented. The system is based on the specific recognition of the heavy metal by a new synthesized ionophore based on a modified thiourea, which is attached to the gold nanoparticles. This interaction generates a change on the gold Surface Plasmon Resonance (SPR) band. The sensitivity and selectivity of the procedure is firstly studied in batch. The obtained results demonstrate the mercury selective response over the different tested ions that can be found in environmental water samples. Due to the remarkable unusual rapid signal change observed during the interaction of the metal and the modified gold nanoparticles, the reaction can be easily performed in a microfluidic system. Results obtained by using the microfluidic system revealed improved analytical features compared to batch experiments such as a lower detection limit (11 ppb), higher sensitivity and faster analysis time, all this with an easy and automated procedure. Therefore, the approach has shown great potential for designing low cost instrumentation for automatic in-field discrete or continuous measurements of Hg(II).
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Carbon nanotube-based nanocomposite sensor tuned with a catechol as novel electrochemical recognition platform of uranyl ion in aqueous samples

  • Muñoz, Jose|||0000-0001-9529-6980
  • Montes, Raquel|||0000-0001-8805-9987
  • Bastos Arrieta, Julio|||0000-0002-8939-6253
  • Guardingo Melián, Mireia
  • Busqué, Félix|||0000-0001-7566-4264
  • Ruiz-Molina, Daniel|||0000-0002-6844-8421
  • Palet, Cristina|||0000-0002-7467-613X
  • García Orellana, Jordi|||0000-0002-0543-2641
  • Baeza, Mireia|||0000-0002-2240-6410
This article reports a novel electrochemical recognition platform based on a nanocomposite carbon paste electrode containing carbon nanotubes modified with gold nanoparticles carrying a thiolated catechol for the fast amperometric determination of uranyl ion (UO ) in water. Recognition of UO is accomplished by supramolecular chemistry due to the formation of an inclusion complex between catechol and UO . The amperometric device operates at -0.40 V vs. Ag/AgCl, where the reduction of UO takes place on the electrode surface, covering a linear range from 0.49 to 170 μg L UO in a 0.1 M boric acid buffer solution at pH 5.3. The developed sensing system presents good response towards UO in aqueous environmental samples, with good selectivity over other browsed cations and can be easily reset by simple polishing. This platform has demonstrated to be a potential alternative regarding to the common standard bench-top analytical techniques for the development of in-field devices for in-situ monitoring.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Highly versatile and automated total ammonia nitrogen compact analyzer suitable for different types of water samples

  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
  • Puyol, Mar|||0000-0002-9274-2284
Continuous monitoring of total ammonia nitrogen (TAN) currently needs to improve further not only to meet optimal analytical features but also to reduce equipment maintenance needs and avoid manual intervention. The development, evaluation in different aqueous samples (fresh and wastewater) and validation of a fully automated and adaptable miniaturized potentiometric analytical instrument with this purpose are presented. The main goals accomplished are a wider and adaptable working range (0.08 to 1000 mg L-1 NH4+) with a detection limit of 0.03 mg L-1 and a significant reduction of reagent and sample consumption, as well as waste generation, compared to current commercial potentiometric flow analyzers. Moreover, different programmable calibration and sample analysis protocols have been successfully applied. Finally, suitable analytical features in terms of accuracy and precision are achieved even with samples with very complex matrices without any pretreatment required.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Multi-parametric polymer-based potentiometric analytical microsystem for future manned space missions

  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Puyol, Mar|||0000-0002-9274-2284
  • Casalta, Joan Manel
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
The construction and evaluation of a Cyclic Olefin Copolymer (COC)-based continuous flow potentiometric microanalyzer to simultaneously monitor potassium, chloride and nitrate ions in samples from an on-board water recycling process expected to be installed in future manned space missions is presented. The main goals accomplished in this work address the specific required characteristics for a miniaturized on-line monitoring system to control water quality in such missions. To begin with, the integration of three ion-selective electrodes (ISEs) and a reference electrode in a compact microfluidic platform that incorporates a simple automatic autocalibration process allows obtaining information about the concentration of the three ions with optimal analytical response characteristics, but moreover with low reagents consumption and therefore with few waste generation, which is critical for this specific application. By a simple signal processing (signal removal) the chloride ion interference on the nitrate electrode response can be eliminated. Furthermore, all fluidics management is performed by computer-controlled microvalves and micropumps, so no manual intervention of the crew is necessary. The analytical features provided by the microsystem after the optimization process were a linear range from 6.3 to 630 mg L-1 and a detection limit of 0.51 mg L-1 for the potassium electrode, a linear range from 10 to 1000 mg L-1 and a detection limit of 1.58 mg L-1 for the chloride electrode and a linear range from 10 to 1000 mg L-1 and a detection limit of 3.37 mg L-1 for the nitrate electrode with a reproducibility (RSD) of 4%, 2% and 3% respectively. Sample throughput was 12 h-1 with a reagent consumptions lower than 2 mL per analysis.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Potentiometric analytical microsystem based on the integration of a gas-diffusion step for on-line ammonium determination in water recycling processes in manned space missions

  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Ymbern Llorens, Oriol|||0000-0003-1997-6794
  • Puyol, Mar|||0000-0002-9274-2284
  • Casalta, Joan Manel
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
The design, construction and evaluation of a versatile cyclic olefin copolymer (COC)-based continuous flow potentiometric microanalyzer to monitor the presence of ammonium ion in recycling water processes for future manned space missions is presented. The microsystem integrates microfluidics, a gas-diffusion module and a detection system in a single substrate. The gas-diffusion module was integrated by a hydrophobic polyvinylidene fluoride (PVDF) membrane. The potentiometric detection system is based on an all-solid state ammonium selective electrode and a screen-printed Ag/AgCl reference electrode. The analytical features provided by the analytical microsystem after the optimization process were a linear range from 0.15 to 500mgL-1 and a detection limit of 0.07±0.01mgL-1. Nevertheless, the operational features can be easily adapted to other applications through the modification of the hydrodynamic variables of the microfluidic platform.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Low cost and compact analytical microsystem for carbon dioxide determination in production processes of wine and beer

  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Ymbern Llorens, Oriol|||0000-0003-1997-6794
  • Izquierdo, David|||0000-0002-4746-3139
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
The design, construction and evaluation of a low cost, cyclic olefin copolymer (COC)-based continuous flow microanalyzer, with optical detection, to monitor carbon dioxide in bottled wines and beers as well as in fermentation processes, is presented. The microsystem, constructed by computer numerically controlled (CNC) micromilling and using a multilayer approach, integrates microfluidics, gas-diffusion module and an optical flow-cell in a single polymeric substrate. Its size is slightly bigger than a credit card, exactly 45 × 60 × 4 mm in the microfluidic and diffusion module zone and 22.5 × 40 × 3 mm in the flow-cell zone. The gas-diffusion module is based on a hydrophobic polyvinylidene fluoride (PVDF) membrane, which allows the transfer of the carbon dioxide present in the sample to a bromothymol blue (BTB) pH-sensitive acceptor solution, where the color change is measured optically. The detection system consisted of a LED with an emission peak at 607 nm and a photodiode integrated in a printed circuit board (PCB). The obtained analytical features after the optimization of the microfluidic platform and hydrodynamic variables are a linear range from 255 to 10000 mg L-1 of CO2 and a detection limit of 83 mg L-1 with a sampling rate of 30 samples h-1.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Gas diffusion as a new fluidic unit operation for centrifugal microfluidic platforms

  • Ymbern Llorens, Oriol|||0000-0003-1997-6794
  • Sández, Natàlia|||0000-0003-1712-3552
  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Puyol, Mar|||0000-0002-9274-2284
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
A centrifugal microfluidic platform prototype with an integrated membrane for gas diffusion is presented for the first time. The centrifugal platform allows multiple and parallel analysis on a single disk and integrates at least ten independent microfluidic subunits, which allow both calibration and sample determination. It is constructed with a polymeric substrate material and it is designed to perform colorimetric determinations by the use of a simple miniaturized optical detection system. The determination of three different analytes, sulfur dioxide, nitrite and carbon dioxide, is carried out as a proof of concept of a versatile microfluidic system for the determination of analytes which involve a gas diffusion separation step during the analytical procedure.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Versatile lock and key assembly for optical measurements with microfluidic platforms and cartridges

  • Ymbern Llorens, Oriol|||0000-0003-1997-6794
  • Berenguel-Alonso, Miguel|||0000-0002-3759-3634
  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Gómez-de Pedro, Sara|||0000-0002-3794-5820
  • Izquierdo, David|||0000-0002-4746-3139
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
A novel and versatile optical reader for microfluidic platforms is presented. The reader includes a modular insertion port based on the lock and key concept for reproducible alignment with a miniaturized optical detection system comprising an interchangeable light emitting diode (LED) and a photodiode. The modular nature of the insertion port allows the use of microfluidic platforms in variable shapes and fluidic configurations. Three different analytical methodologies based on absorbance or fluorescence measurements were used to demonstrate the flexibility and reproducibility of the proposed experimental setup.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Biparametric potentiometric analytical microsystem for nitrate and potassium monitoring in water recycling processes for manned space missions

  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Arasa-Puig, Eva|||0000-0002-0702-0069
  • Puyol, Mar|||0000-0002-9274-2284
  • Casalta, Joan Manel
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
The construction and evaluation of a Low Temperature Co-fired Ceramics (LTCC)-based continuous flow potentiometric microanalyzer prototype to simultaneously monitor the presence of two ions (potassium and nitrate) in samples from the water recycling process for future manned space missions is presented. The microsystem integrates microfluidics and the detection system in a single substrate and it is smaller than a credit card. The detection system is based on two ion-selective electrodes (ISEs), which are built using all-solid state nitrate and potassium polymeric membranes, and a screen-printed Ag/AgCl reference electrode. The obtained analytical features after the optimization of the microfluidic design and hydrodynamics are a linear range from 10 to 1000mgL-1 and from 1.9 to 155mgL-1 and a detection limit of 9.56mgL-1 and 0.81mgL-1 for nitrate and potassium ions respectively.