Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Novel autocalibration strategy for disposable potentiometric test strips

  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Garrido Carretero, Laia|||0009-0005-5464-886X
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
  • Puyol, Mar|||0000-0002-9274-2284
Potentiometry, particularly involving ion-selective electrodes (ISEs), is widely employed in laboratories due to its selectivity and compatibility with portable instruments. However, ISEs face a drawback -instability over time, requiring frequent calibration for precise and reliable results. This manual calibration process contradicts the user-friendly concept and inhibits the development of single-use quantitative devices for untrained personnel. To solve this limitation, a novel potentiometric autocalibration procedure, which is automated, is presented, and successfully tested for the first time with versatile potentiometric disposable test strips to perform the determination of chloride ion in sweat as a demonstrator. The test strips are based on a cyclic olefin copolymer platform, where two identical Ag/AgCl chloride ISEs are integrated, one acting as indicator and the other as reference electrode. Comparison of chloride results in real sweat samples between those obtained with the proposed test strips performing the novel autocalibration procedure and using ion chromatography reveals that the automated procedure effectively allows quantitative chloride ion analysis with good analytical features: linear range from 10 to 150 mM (covering the pathological range), average inter-method error of 7 % and average RSD between test strips of 4 %. By carefully selecting the initial solution composition in direct contact with each electrode, the autocalibration ensures that potentiometric test strips can be calibrated just before its use without requiring conscious user involvement. This breakthrough not only streamlines the process but also opens the possibility for the development of cheap disposable potentiometric test strips, accessible to non-experts operators, to quantitatively determine selected analytes in different fields.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Multilayered Manufacturing Method for Microfluidic Systems Using Low-Cost, Resin-Based Three-Dimensional Printing

  • Manqueros-Avilés, Victor Edi
  • Coto-Fuentes, Hesner|||0000-0002-9548-7864
  • Guevara Amatón, Karla Victoria
  • Valdés-Perezgasga, Francisco|||0000-0002-7176-3641
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
This work presents a multilamination method for fabricating microfluidic devices or analytical microsystems using commercial 3D printers and photocurable resins as primary components. The developed method was validated by fabricating devices for the colorimetric measurement of copper ions in aqueous solutions, achieving results comparable to traditional cyclic olefin copolymer (COC) systems. The microfluidic platforms demonstrated stability and functionality over a twelve-week testing period. Channels with minimum dimensions of 0.4 mm × 0.4 mm were fabricated, and the feasibility of using resin modules for optical applications was demonstrated. This study highlights the potential of combining 3D printing with multilamination procedures as a versatile alternative, offering flexibility through the selection of a variety of available resins and commercial printers, as well as the ease of design development. This method offers significant reductions in cost, time, and manufacturing complexity by eliminating the need for equipment such as CNC machines, presses, and ovens, which are typically required in other multilamination technologies like LTCC and COC.
Dipòsit Digital de Documents de la UAB
Publication Artículo de revisión (ReviewArticle)

The Personal Glucose Meter as the Measurement Principle in Point-of-Care Applications

  • Cano, Mònica
  • Valle, Manel del|||0000-0002-1032-8611
A personal glucose meter (PGM) is a medical device that measures blood glucose levels and can be found worldwide. Owing to their sensitivity, simplicity, portability, and low cost, PGMs stand as one of the most frequently utilized analytical methods. This work reviews the different applied methodologies for detecting analytes other than glucose employing a PGM and how it can be incorporated for point-of-care diagnosis needs. To visualize the variants, first, a classification is made according to the biorecognition elements used (aptamers, antibodies, etc.), and where the determination of different analytes is done through the glucose signal using different glucose-generating enzymes such as invertase or glucosidase. Transduction can also be based on the use of nanocarriers that generally encapsulate glucose, although it is also possible to find a combination of the two aforementioned strategies. The PGM can also be used for the direct detection of interfering substances of the biosensor, such as NADH or paracetamol. Lastly, we discuss how a PGM might have been implemented to detect COVID-19 and how it could be used on a massive scale for the point-of-care diagnosis of a pandemic.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Testing of a novel automated point-of-care analyzer for blood ammonium monitoring in a clinical setting

  • Rebollo Calderón, Beatriz|||0000-0001-5968-8004
  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Ormazábal, Aida
  • Artuch, R.|||0000-0002-3422-9685
  • Rosell Ferrer, Javier|||0000-0002-9691-328X
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
  • Puyol, Mar|||0000-0002-9274-2284
Certain diseases are marked by elevated ammonium levels in the blood, a condition known as hyperammonemia. Prompt detection and medical intervention are crucial to prevent potentially fatal outcomes. Therefore, ammonium levels should be monitored regularly, typically in referral hospitals where specialized and costly equipment is available. Although compact commercial devices are available for this purpose, none of them meet all the technical and analytical requirements needed for direct blood analysis, and current reported strategies have not been validated with enough samples to confirm results reliably. We present a robust and reliable automated point-of-care (POC) analyzer for the potentiometric determination of ammonium in blood. Comprising three computer-controlled modules-fluid management, detection, and data acquisition and transmission-this system combines portability, ease of use, and affordability. It can directly measure untreated blood samples, significantly reducing analysis time. Fully automated, it operates unsupervised with minimal lab personnel intervention. Analytical quality parameters include 5% RSD repeatability (n = 8), a limit of detection of 24 μM, a working range of 30-1000 µM and a sample volume of 215 µL. Successfully implemented in a hospital for 2 months, it analyzed 238 blood samples in parallel with the hospital's reference method showing comparable results (paired t-test, Passing-Bablok regression and Bland-Altman Plot) and randomly distributed errors, with a 4% accuracy calculated as mean error. Results indicate the POC analyzer effectiveness and reliability in a clinical setting compared to currently reported or commercially available equipment, being suitable for bedside monitoring of conditions associated with hyperammonemia in healthcare centers, including emergency rooms and clinics in developing countries.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Competitive magneto enzyme-linked miRNA assay for quantification of microRNAs in exosomes

  • Bernuz, Mireia|||0000-0002-2052-6902
  • Martí, Mercè|||0000-0002-1846-0043
  • Pividori, María Isabel|||0000-0002-5266-7873
MicroRNAs (miRNAs) are non-coding, short RNA sequences involved in gene regulation. Although intracellular molecules, miRNAs are also found in biological fluids, where they serve as promising diagnostic and prognostic biomarkers. In liquid biopsies, miRNAs are protected from RNase activity through association with proteins or as part of the exosomal cargo. Current methods for miRNA detection are technically demanding and resource intensive. Here, we present a competitive magneto enzyme-linked miRNA (ELmiRNA) assay for the direct quantification of miRNAs in exosomes. The assay is based on a DNA scaffold containing two miRNA templates, each hybridized to a complementary double-tagged probe and anchored via a poly(A) tail to oligo(dT)-magnetic particles. Upon incubation with miRNA-containing samples, displacement of the tagged probes occurs, enabling indirect quantification through enzymatic labeling. As proof of concept, miRNA-21 and miRNA-27a, both upregulated in breast cancer, were quantified in MCF-7 and MDA-MB-231 cells and their derived exosomes. The assay achieved limits of detection of 1.5 nM (9.6 pg μL) and 2.7 nM (16.2 pg μL) for miRNA-21 and miRNA-27a, respectively, and yielded 10-30 copies per exosome, in agreement with RT-qPCR validation. The ELmiRNA assay combines sensitivity and selectivity with high-throughput analysis using a routine laboratory filter-based microplate reader. This approach represents a simplified, amplification-free alternative to RT-qPCR for miRNA quantification in exosomes, suitable for routine implementation in standard clinical and research laboratories.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Biotin-specific molecularly imprinted polymers as a biomimetic test line in lateral flow assays

  • Marfà, Jennifer|||0000-0001-5321-3841
  • Valle, Anaixis del|||0000-0001-5587-9081
  • Rovatti Pupin, Rafael|||0009-0009-8834-8557
  • Baró Sastre, Barbara|||0000-0001-7780-1744
  • Bassat, Quique|||0000-0003-0875-7596
  • Taboada Sotomayor, Maria Del Pilar|||0000-0002-6173-7888
  • Pividori, María Isabel|||0000-0002-5266-7873
Lateral flow assays are widely used for rapid diagnostics at the point of care. However, their dependence on biological receptors limits their stability, scalability, and cost-effectiveness. This work demonstrates the use of biotin-specific molecularly imprinted polymers (biotin-MIPs) as synthetic recognition elements in nucleic acid lateral flow (NALF) assays. The biotin-MIPs were synthesized, structurally characterized, and integrated into the nitrocellulose membrane as a test line. Their selective binding affinity was first validated using biotinylated horseradish peroxidase as a model analyte. The platform was then evaluated for the detection of double-tagged PCR amplicons from Escherichia coli labeled with biotin and digoxigenin, achieving a visual detection limit of 2 ng mL-1 and a limit of detection of 1.8 ng mL-1, with no detectable signal in negative controls. Clinical feasibility was further assessed retrospectively using swab specimens collected during routine third-trimester screening (35-37 weeks of gestation) for Group B Streptococcus, a major cause of neonatal sepsis. In this proof-of-concept study, the MIP-based NALF assay showed complete qualitative agreement with the qPCR reference classification and the gold standard microbiological culture, demonstrating the compatibility of this approach with battery-operated portable PCR amplification. Unlike biological receptors, MIPs offer robustness, long-term stability at room temperature, and animal-free scalable production. These features position the MIP-based NALF platform as a cost-effective alternative to antibody-based tests and a promising foundation for next-generation lateral flow diagnostics for the detection of communicable diseases at the point of care.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Molecularly Imprinted Polymers as Biomimetic Test Zones in Paper-Based Nucleic Acid Assays-Comparing Vertical and Lateral Flow Formats

  • Marfà, Jennifer|||0000-0001-5321-3841
  • Valle, Anaixis del|||0000-0001-5587-9081
  • Taboada Sotomayor, Maria Del Pilar|||0000-0002-6173-7888
  • Pividori, María Isabel|||0000-0002-5266-7873
The development of rapid and sensitive point-of-care nucleic acid tests benefits from robust synthetic recognition elements. Here, a biotin-specific molecularly imprinted polymer (MIP) was synthesized using an optimized protocol and integrated as a biomimetic test zone into two paper-based formats: nucleic acid vertical flow (NAVF) and nucleic acid lateral flow (NALF). Both platforms were evaluated for the detection of double-tagged PCR amplicons from Escherichia coli. NAVF enabled a 3 min visual readout with an LOD of 1.00 × 10-2 ng mL-1. NALF provided a total assay time of <15 min and achieved a visual LOD of 3.17 × 10-2 ng mL-1. Overall, the results demonstrate the versatility of biotin-MIPs as stable synthetic receptors for rapid, low-cost paper-based nucleic acid assays, with NAVF prioritizing speed and design flexibility and NALF prioritizing higher analytical sensitivity.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Rapid and portable molecular test for Mycobacterium sp. based on double-tagging amplification and electrochemical readout

  • Mesas Gómez, Melania|||0000-0002-3297-1077
  • Ropero Gil, Daniel|||0009-0008-2522-1340
  • Molina-Moya, Barbara|||0000-0001-5144-2165
  • Pallarès-Rusiñol, Arnau|||0000-0001-9990-148X
  • Ferrer-Dalmau, Jofre|||0000-0002-7415-6222
  • Julián, Esther|||0000-0002-6558-3978
  • Domínguez, José|||0000-0001-7888-0309
  • Pividori, María Isabel|||0000-0002-5266-7873
Tuberculosis (TB) remains one of the leading causes of death worldwide, with Mycobacterium tuberculosis as the main pathogen responsible. Although several rapid molecular tests endorsed by the World Health Organization (WHO) show high accuracy, their implementation in low-resource settings is still limited by cost and infrastructure requirements. In this work, a rapid and portable molecular test was developed for Mycobacterium sp. detection based on double-tagging polymerase chain reaction (PCR) and electrochemical magneto-genosensing. The method enables amplification of mycobacterial DNA using primers targeting the gyrB and IS6110 genes through a double-tagging PCR completed within approximately one hour, followed by electrochemical detection on a handheld, battery-operated device, yielding a measurable current signal within 15 minutes, including single-step incubation and electrochemical readout. The test achieved a limit of detection as low as 117 CFU mL−1 for the gyrB target, comparable to the commercial GeneXpert® MTB/RIF assay, while significantly reducing assay time and equipment needs. Total analysis, including DNA extraction, amplification and detection, was completed within approximately two hours. In addition, comparable electrochemical responses were obtained when PCR amplification was carried out using either a conventional benchtop thermocycler or a portable battery-operated miniPCR device, further supporting the applicability of the method in decentralized and field settings. Overall, this approach combines high sensitivity, portability, and simplicity, offering a promising solution for point-of-care TB diagnosis and adaptable to other infectious diseases by changing the primer sequences.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Live synthesis of selective carbon dots as fluorescent probes for cobalt determination in water with an automatic microanalyzer

  • Pascual-Esco, Alex
  • Lleonart, Pere
  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
  • Puyol, Mar|||0000-0002-9274-2284
A new strategy integrating the straight synthesis of carbon dots (CDs) and their direct use for the determination of heavy metals by means of fuorescence quenching is presented. The proposal consists of a modular analyzer, which includes a low temperature co-fred ceramics (LTCC) microreactor for the synthesis of CDs and a cyclic olefn copolymer (COC) microfuidic platform, which automatically performs a reverse fow injection analysis (rFIA) protocol for the determination of heavy metal ions in water by CD fuorescence quenching. As a proof of concept, nitrogen-doped CDs were synthesized from acrylic acid and ethylenediamine (ED) with quantum yields (QYs) of up to 44%, which are selective to cobalt. With the described system, we synthesized homogeneous CDs without the need for further purifcation and with the minimum consumption of reagents, and optimized fuorescence measurements can be performed with freshly obtained luminescent nanomaterials that have not undergone decomposition processes. They have an averagehydrodynamic diameter of 4.2±0.9 nm and maximum excitation and emission wavelengths at 358 nm and 452 nm, respectively. The system allows the automatic dilution and bufering of the synthesized CDs and the sample prior to the determination of cobalt. The concentration of cobalt was determined with good sensitivity and a limit of detection of 7 μg·L-1 with a linear range of 0.02-1 mg·L-1 of Co2+. Spiked tap water and river water samples were analyzed, obtaining recovery from 98 to 104%. This demonstrates the potential of the equipment as an efcient on-site control system for heavy metal monitoring in water.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Highly versatile and automated total ammonia nitrogen compact analyzer suitable for different types of water samples

  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
  • Puyol, Mar|||0000-0002-9274-2284
Continuous monitoring of total ammonia nitrogen (TAN) currently needs to improve further not only to meet optimal analytical features but also to reduce equipment maintenance needs and avoid manual intervention. The development, evaluation in different aqueous samples (fresh and wastewater) and validation of a fully automated and adaptable miniaturized potentiometric analytical instrument with this purpose are presented. The main goals accomplished are a wider and adaptable working range (0.08 to 1000 mg L-1 NH4+) with a detection limit of 0.03 mg L-1 and a significant reduction of reagent and sample consumption, as well as waste generation, compared to current commercial potentiometric flow analyzers. Moreover, different programmable calibration and sample analysis protocols have been successfully applied. Finally, suitable analytical features in terms of accuracy and precision are achieved even with samples with very complex matrices without any pretreatment required.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Analysis of spices & herbs and its phenolic content by means of an electronic tongue

  • Cetó, Xavier|||0000-0003-1589-6076
  • Sarma, Munmi
  • Valle, Manel del|||0000-0002-1032-8611
The drying process to which herbs and spices are submitted has a significant impact on the flavour and quality of those as many compounds might be degraded or transformed. This is especially relevant for most aromatic and bioactive compounds (e.g., phenolic compounds), which values have been reported to diminish during the drying process. In this direction, herein we explore the usage of an electronic tongue (ET) as a tool to assist on the monitoring of herbs and spices quality. The proposed approach is based on the use of a simple extraction method prior to the analysis of the samples with an array of voltammetric sensors in combination with pattern-recognition methods. Firstly, a partial least squares regression (PLS) model was built, which allowed the quantification of the total phenolic content (R.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Improved biosensing of Legionella by integrating filtration and immunomagnetic separation of the bacteria retained in filters

  • Mesas Gómez, Melania|||0000-0002-3297-1077
  • Molina-Moya, Barbara|||0000-0001-5144-2165
  • de Araújo, Bárbara Camila
  • Boldrin Zanoni, Maria Valnice|||0000-0002-2296-1393
  • Julián, Esther|||0000-0002-6558-3978
  • Domínguez, José|||0000-0001-7888-0309
  • Pividori, María Isabel|||0000-0002-5266-7873
A novel approach is presented that combines filtration and the direct immunomagnetic separation of the retained bacteria Legionella in filters, for further electrochemical immunosensing. This strategy allows for the separation and preconcentration of the water-borne pathogen from high-volume samples, up to 1000 mL. The limit of detection of the electrochemical immunosensor resulted in 100 CFU mL-1 and improved up to 0.1 CFU mL-1 when the preconcentration strategy was applied in 1 L of sample (103-fold improvement). Remarkably, the immunosensor achieves the limit of detection in less than 2.5 h and simplified the analytical procedure. This represents the lowest concentration reported to date for electrochemical immunosensing of Legionella cells without the need for pre-enrichment or DNA amplification. Furthermore, the study successfully demonstrates the extraction of bacteria retained on different filtering materials using immunomagnetic separation, highlighting the high efficiency of the magnetic particles to pull out the bacteria directly from solid materials. This promising feature expands the applicability of the method beyond water systems for detecting bacteria retained in air filters of air conditioning units by directly performing the immunomagnetic separation in the filters.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Mycobacterium detection method combining filtration, immunomagnetic separation, and electrochemical readout in a portable biosensing device

  • Mesas Gómez, Melania|||0000-0002-3297-1077
  • Molina-Moya, Barbara|||0000-0001-5144-2165
  • de Araújo, Bárbara Camila
  • Pallarès-Rusiñol, Arnau|||0000-0001-9990-148X
  • Ferrer-Dalmau, Jofre|||0000-0002-7415-6222
  • Boldrin Zanoni, Maria Valnice|||0000-0002-2296-1393
  • Domínguez, José|||0000-0001-7888-0309
  • Julián, Esther|||0000-0002-6558-3978
  • Pividori, María Isabel|||0000-0002-5266-7873
This study addresses a straightforward and highly sensitive approach for detecting Mycobacterium fortuitum. The method involves a combination of filtration and direct immunomagnetic separation to isolate the bacteria retained on filters for further electrochemical magneto immunosensing in a handheld device. Unlike conventional methods involving pre-enrichment by culturing, this approach employs a simplified preconcentration technique, which includes filtration of large water samples, up to 100 mL, followed by a one-step process of immunomagnetic separation and labeling. After a 60-min, during which the filter with the retained bacteria and all the reagents (including modified magnetic particles and enzymatic conjugates) are incubated, the resulting product is directly drop into a cartridge, capable of performing magnetic actuation and washing. The electrochemical readout is carried out on a portable battery-operated device within 30 seconds. Remarkably, the immunosensor demonstrates an outstanding limit of detection of 5 CFU mL-1 in hemodialysis water processing 100 mL of sample. This achievement is remarkable considering the short and simplified analytical procedure, compared to the traditional isolation and culturing of mycobacteria, which typically takes 2 weeks.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Los exosomas, nuevas herramientas para el diagnóstico de enfermedades no transmisibles en biopsias líquidas

Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Peptide-based biosensing approaches for targeting breast cancer-derived exosomes

  • da Fonseca Alves, Rafael|||0000-0002-6319-9817
  • Pallarès-Rusiñol, Arnau|||0000-0001-9990-148X
  • Rossi, Rosanna|||0000-0002-3656-2908
  • Martí, Mercè|||0000-0002-1846-0043
  • Rezende Vaz, Emilia|||0000-0003-1733-9812
  • Gonçalves de Araújo, Thaise
  • Taboada Sotomayor, Maria Del Pilar|||0000-0002-6173-7888
  • Pividori, María Isabel|||0000-0002-5266-7873
Exosomes are nanovesicles present in all the biological fluids, making them attractive as non-invasive biomarkers for diseases like cancer, among many others. However, exosomes are complex to separate and detect, requiring comprehensive molecular characterization for their routine use in diagnostics. This study explores the use of peptides as cost-effective and stable alternatives to antibodies for exosome binding. To achieve that, phage display technology was employed to select peptides with high specificity for target molecules in exosomes. Specifically, a selected peptide was evaluated for its ability to selectively bind breast cancer-derived exosomes. Proteomic analysis identified 38 protein candidates targeted by the peptide on exosome membranes. The binding of the peptide to breast cancer-derived exosomes was successfully demonstrated by flow cytometry and magneto-actuated immunoassays. Furthermore, an electrochemical biosensor was also tested for breast cancer-derived exosome detection and quantification. The peptide demonstrated effective binding to exosomes from aggressive cancer cell lines, offering promising results in terms of specificity and recovery. This research shows potential for developing rapid, accessible diagnostic tools for breast cancer, especially in low-resource healthcare settings.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Evaluating smartphone-based optical readouts for immunoassays in human and veterinary healthcare, A comparative study

  • Mesas Gómez, Melania|||0000-0002-3297-1077
  • Julián, Esther|||0000-0002-6558-3978
  • Armengou Ruiz, Lara|||0000-0003-4715-7323
  • Pividori, María Isabel|||0000-0002-5266-7873
Recent advances have significantly enhanced the use of smartphone devices for medical diagnostics. This study uses high-resolution cameras in mobile devices to capture and process bioassay images, enabling the quantification of diverse biomarkers across a range of diagnostic tests conducted on 96-well microplates. The study evaluates the effectiveness of this technology through protein quantification techniques and immunoassays that generate colorimetric responses at specific wavelengths. It includes the assessment of bicinchoninic acid and Bradford protein quantification methods, alongside a conventional immunoassay for detecting mare antibodies in colostrum to monitor foal immunodeficiencies. Further application involves the readout of magneto-actuated immunoassays aimed at quantifying bacteria. The results obtained from benchtop spectrophotometry at 595, 562, and 450 nm are compared with those acquired using a smartphone, which identified color intensities in shades of blue, purple, and yellow. This comparison yields promising correlations for the samples tested, suggesting a high degree of accuracy in the smartphone capability to analyze bioassay outcomes. The analysis via smartphone is facilitated by a specific app, which processes the images captured by the phone camera to quantify color intensities corresponding to different biomarker concentrations. Detection limits of 12.3 and 22.8 μg mL for the bicinchoninic acid assay and 36.7 and 45.4 μg mL for the Bradford are obtained for protein quantification using the spectrophotometer and the smartphone app, respectively. For mare's antibodies in colostrum, the values are 1.14 and 1.72 ng mL, while the detection of E. coli is performed at 2.0 x 10 and 2.9 × 10 CFU mL, respectively. This approach offers further advantages, including wide availability, cost-effectiveness, portability, compared to traditional and expensive benchtop instruments.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Rapid diagnostic test for assessment of cellular immune response in a viral infection as a model

  • Bernuz, Mireia|||0000-0002-2052-6902
  • Porras, Juan Carlos
  • Egri, Natalia|||0000-0001-7698-0672
  • González-Navarro, Europa Azucena|||0000-0003-3310-5557
  • Juan, Manel|||0000-0002-3064-1648
  • Pividori, María Isabel|||0000-0002-5266-7873
  • Martí, Mercè|||0000-0002-1846-0043
The global SARS-CoV-2 pandemic has highlighted the critical importance of evaluating adaptive immunological status in both infected individuals and those who have been vaccinated. While the humoral immune response has been extensively studied, the cellular immune component has not progressed as rapidly due to challenges in developing rapid diagnostic tests for activated T cells. This study introduces a rapid, user-friendly assay aimed at addressing this need by using the early expression of interferon-gamma (IFN-γ) transcripts for rapid and direct evaluation. Using a novel design, this assay measures IFN-γ mRNA rather than its protein levels, thereby significantly shortening the time to result compared to traditional methods. The process involves incubating whole blood with a mixture of Spike and Nucleocapsid peptides, followed by immunomagnetic separation of CD3+ T cells and subsequent double-tagging RT-PCR. A lateral flow assay (LFA) is then used for detection, allowing IFN-γ mRNA levels to be assessed rapidly. Non-stimulated samples are used as controls to establish baseline IFN-γ expression. The intensity of the LFA signals from the stimulated samples is then compared to these baseline values using a smartphone interface. Furthermore, the study includes a time course analysis to monitor the T cell response dynamics over time in infected individuals. This LFA-IFN-γ represents a significant progress in the field of rapid diagnostics, offering a one-day protocol that simplifies testing procedures and is especially suitable for low-resource settings.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Resolution of Glycerol, Ethanol and Methanol Employing a Voltammetric Electronic Tongue

  • de Oliveira, João Pedro Jenson|||0000-0003-1355-2886
  • Bonet-SanEmeterio, Marta|||0000-0002-5076-8136
  • Cardoso de Sá, Acelino|||0000-0002-9811-4879
  • Cetó, Xavier|||0000-0003-1589-6076
  • Lataro Paim, Leonardo|||0000-0002-5113-6376
  • Valle, Manel del|||0000-0002-1032-8611
This paper reports the use of nanoparticles (NPs)-modified voltammetric sensors for the rapid determination of glycerol in the presence of ethanol and methanol, which are used in the transesterification reaction of biodiesel production. Two different modified electrodes have been prepared to form the electronic tongue (ET): copper hexacyanoferrate NPs obtained by chemical synthesis and mixed into graphite/epoxy (GEC) electrode, and nickel hydroxide NPs electrodeposited in reduced graphene oxide onto a GEC electrode. The response characteristics of these electrodes were first evaluated by building the respective calibration against glycerol, ethanol, and methanol. The electrodes demonstrated good stability during their analytical characterization, while principal component analysis confirmed the differentiated response against the different alcohols. Finally, the quantification of mixtures of these substances was achieved by a genetic algorithm-artificial neural networks (GA-ANNs) model, showing satisfactory agreement between expected and obtained values.