Skip to main content

SENS4ALL. PRUEBAS RAPIDAS DE CARACTERISTICAS MEJORADAS PARA EL DIAGNOSTICO GLOBAL

BES-2017-082694

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de Promoción del Talento y su Empleabilidad en I+D+i
Subprogram Subprograma Estatal de Formación
Call Contratos Predoctorales
Call year 2017
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSIDAD AUTONOMA DE BARCELONA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Biotin-specific molecularly imprinted polymers as a biomimetic test line in lateral flow assays

  • Marfà, Jennifer|||0000-0001-5321-3841
  • Valle, Anaixis del|||0000-0001-5587-9081
  • Rovatti Pupin, Rafael|||0009-0009-8834-8557
  • Baró Sastre, Barbara|||0000-0001-7780-1744
  • Bassat, Quique|||0000-0003-0875-7596
  • Taboada Sotomayor, Maria Del Pilar|||0000-0002-6173-7888
  • Pividori, María Isabel|||0000-0002-5266-7873
Lateral flow assays are widely used for rapid diagnostics at the point of care. However, their dependence on biological receptors limits their stability, scalability, and cost-effectiveness. This work demonstrates the use of biotin-specific molecularly imprinted polymers (biotin-MIPs) as synthetic recognition elements in nucleic acid lateral flow (NALF) assays. The biotin-MIPs were synthesized, structurally characterized, and integrated into the nitrocellulose membrane as a test line. Their selective binding affinity was first validated using biotinylated horseradish peroxidase as a model analyte. The platform was then evaluated for the detection of double-tagged PCR amplicons from Escherichia coli labeled with biotin and digoxigenin, achieving a visual detection limit of 2 ng mL-1 and a limit of detection of 1.8 ng mL-1, with no detectable signal in negative controls. Clinical feasibility was further assessed retrospectively using swab specimens collected during routine third-trimester screening (35-37 weeks of gestation) for Group B Streptococcus, a major cause of neonatal sepsis. In this proof-of-concept study, the MIP-based NALF assay showed complete qualitative agreement with the qPCR reference classification and the gold standard microbiological culture, demonstrating the compatibility of this approach with battery-operated portable PCR amplification. Unlike biological receptors, MIPs offer robustness, long-term stability at room temperature, and animal-free scalable production. These features position the MIP-based NALF platform as a cost-effective alternative to antibody-based tests and a promising foundation for next-generation lateral flow diagnostics for the detection of communicable diseases at the point of care.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Molecularly Imprinted Polymers as Biomimetic Test Zones in Paper-Based Nucleic Acid Assays-Comparing Vertical and Lateral Flow Formats

  • Marfà, Jennifer|||0000-0001-5321-3841
  • Valle, Anaixis del|||0000-0001-5587-9081
  • Taboada Sotomayor, Maria Del Pilar|||0000-0002-6173-7888
  • Pividori, María Isabel|||0000-0002-5266-7873
The development of rapid and sensitive point-of-care nucleic acid tests benefits from robust synthetic recognition elements. Here, a biotin-specific molecularly imprinted polymer (MIP) was synthesized using an optimized protocol and integrated as a biomimetic test zone into two paper-based formats: nucleic acid vertical flow (NAVF) and nucleic acid lateral flow (NALF). Both platforms were evaluated for the detection of double-tagged PCR amplicons from Escherichia coli. NAVF enabled a 3 min visual readout with an LOD of 1.00 × 10-2 ng mL-1. NALF provided a total assay time of <15 min and achieved a visual LOD of 3.17 × 10-2 ng mL-1. Overall, the results demonstrate the versatility of biotin-MIPs as stable synthetic receptors for rapid, low-cost paper-based nucleic acid assays, with NAVF prioritizing speed and design flexibility and NALF prioritizing higher analytical sensitivity.