Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Molecularly Imprinted Polymers as Biomimetic Test Zones in Paper-Based Nucleic Acid Assays-Comparing Vertical and Lateral Flow Formats

  • Marfà, Jennifer|||0000-0001-5321-3841
  • Valle, Anaixis del|||0000-0001-5587-9081
  • Taboada Sotomayor, Maria Del Pilar|||0000-0002-6173-7888
  • Pividori, María Isabel|||0000-0002-5266-7873
The development of rapid and sensitive point-of-care nucleic acid tests benefits from robust synthetic recognition elements. Here, a biotin-specific molecularly imprinted polymer (MIP) was synthesized using an optimized protocol and integrated as a biomimetic test zone into two paper-based formats: nucleic acid vertical flow (NAVF) and nucleic acid lateral flow (NALF). Both platforms were evaluated for the detection of double-tagged PCR amplicons from Escherichia coli. NAVF enabled a 3 min visual readout with an LOD of 1.00 × 10-2 ng mL-1. NALF provided a total assay time of <15 min and achieved a visual LOD of 3.17 × 10-2 ng mL-1. Overall, the results demonstrate the versatility of biotin-MIPs as stable synthetic receptors for rapid, low-cost paper-based nucleic acid assays, with NAVF prioritizing speed and design flexibility and NALF prioritizing higher analytical sensitivity.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Improved biosensing of Legionella by integrating filtration and immunomagnetic separation of the bacteria retained in filters

  • Mesas Gómez, Melania|||0000-0002-3297-1077
  • Molina-Moya, Barbara|||0000-0001-5144-2165
  • de Araújo, Bárbara Camila
  • Boldrin Zanoni, Maria Valnice|||0000-0002-2296-1393
  • Julián, Esther|||0000-0002-6558-3978
  • Domínguez, José|||0000-0001-7888-0309
  • Pividori, María Isabel|||0000-0002-5266-7873
A novel approach is presented that combines filtration and the direct immunomagnetic separation of the retained bacteria Legionella in filters, for further electrochemical immunosensing. This strategy allows for the separation and preconcentration of the water-borne pathogen from high-volume samples, up to 1000 mL. The limit of detection of the electrochemical immunosensor resulted in 100 CFU mL-1 and improved up to 0.1 CFU mL-1 when the preconcentration strategy was applied in 1 L of sample (103-fold improvement). Remarkably, the immunosensor achieves the limit of detection in less than 2.5 h and simplified the analytical procedure. This represents the lowest concentration reported to date for electrochemical immunosensing of Legionella cells without the need for pre-enrichment or DNA amplification. Furthermore, the study successfully demonstrates the extraction of bacteria retained on different filtering materials using immunomagnetic separation, highlighting the high efficiency of the magnetic particles to pull out the bacteria directly from solid materials. This promising feature expands the applicability of the method beyond water systems for detecting bacteria retained in air filters of air conditioning units by directly performing the immunomagnetic separation in the filters.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Mycobacterium detection method combining filtration, immunomagnetic separation, and electrochemical readout in a portable biosensing device

  • Mesas Gómez, Melania|||0000-0002-3297-1077
  • Molina-Moya, Barbara|||0000-0001-5144-2165
  • de Araújo, Bárbara Camila
  • Pallarès-Rusiñol, Arnau|||0000-0001-9990-148X
  • Ferrer-Dalmau, Jofre|||0000-0002-7415-6222
  • Boldrin Zanoni, Maria Valnice|||0000-0002-2296-1393
  • Domínguez, José|||0000-0001-7888-0309
  • Julián, Esther|||0000-0002-6558-3978
  • Pividori, María Isabel|||0000-0002-5266-7873
This study addresses a straightforward and highly sensitive approach for detecting Mycobacterium fortuitum. The method involves a combination of filtration and direct immunomagnetic separation to isolate the bacteria retained on filters for further electrochemical magneto immunosensing in a handheld device. Unlike conventional methods involving pre-enrichment by culturing, this approach employs a simplified preconcentration technique, which includes filtration of large water samples, up to 100 mL, followed by a one-step process of immunomagnetic separation and labeling. After a 60-min, during which the filter with the retained bacteria and all the reagents (including modified magnetic particles and enzymatic conjugates) are incubated, the resulting product is directly drop into a cartridge, capable of performing magnetic actuation and washing. The electrochemical readout is carried out on a portable battery-operated device within 30 seconds. Remarkably, the immunosensor demonstrates an outstanding limit of detection of 5 CFU mL-1 in hemodialysis water processing 100 mL of sample. This achievement is remarkable considering the short and simplified analytical procedure, compared to the traditional isolation and culturing of mycobacteria, which typically takes 2 weeks.