BIOSENSORES PARA LA MONITORIZACION DE ENFERMEDADES METABOLICAS HEREDITARIAS. DESARROLLO Y EVALUACION DE PROTOTIPOS FUNCIONALES PARA VALIDACION CONCEPTUAL.

DTS18/00075

•
Funding agency name Instituto de Salud Carlos III
Funding agency acronym ISCIII
Program Programa Estatal de Fomento de la Investigación Científica y Técnica de Excelencia
Subprogram Subprograma Estatal de Generación de Conocimiento
Call Proyectos de Desarrollo Tecnológico en Salud
Call year 2018
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre FUNDACION PARA LA INVESTIGACION Y DOCENCIA SANT JOAN DE DEU
Execution centre HOSPITAL SAN JUAN DE DIOS ESPLUGUES

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Testing of a novel automated point-of-care analyzer for blood ammonium monitoring in a clinical setting

  • Rebollo Calderón, Beatriz|||0000-0001-5968-8004
  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Ormazábal, Aida
  • Artuch, R.|||0000-0002-3422-9685
  • Rosell Ferrer, Javier|||0000-0002-9691-328X
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
  • Puyol, Mar|||0000-0002-9274-2284
Certain diseases are marked by elevated ammonium levels in the blood, a condition known as hyperammonemia. Prompt detection and medical intervention are crucial to prevent potentially fatal outcomes. Therefore, ammonium levels should be monitored regularly, typically in referral hospitals where specialized and costly equipment is available. Although compact commercial devices are available for this purpose, none of them meet all the technical and analytical requirements needed for direct blood analysis, and current reported strategies have not been validated with enough samples to confirm results reliably. We present a robust and reliable automated point-of-care (POC) analyzer for the potentiometric determination of ammonium in blood. Comprising three computer-controlled modules-fluid management, detection, and data acquisition and transmission-this system combines portability, ease of use, and affordability. It can directly measure untreated blood samples, significantly reducing analysis time. Fully automated, it operates unsupervised with minimal lab personnel intervention. Analytical quality parameters include 5% RSD repeatability (n = 8), a limit of detection of 24 μM, a working range of 30-1000 µM and a sample volume of 215 µL. Successfully implemented in a hospital for 2 months, it analyzed 238 blood samples in parallel with the hospital's reference method showing comparable results (paired t-test, Passing-Bablok regression and Bland-Altman Plot) and randomly distributed errors, with a 4% accuracy calculated as mean error. Results indicate the POC analyzer effectiveness and reliability in a clinical setting compared to currently reported or commercially available equipment, being suitable for bedside monitoring of conditions associated with hyperammonemia in healthcare centers, including emergency rooms and clinics in developing countries.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Biomedical point-of-care microanalyzer for potentiometric determination of ammonium ion in plasma and whole blood

  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Rebollo Calderón, Beatriz|||0000-0001-5968-8004
  • Ormazábal, Aida
  • Artuch, R.|||0000-0002-3422-9685
  • Rosell Ferrer, Javier|||0000-0002-9691-328X
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
  • Puyol, Mar|||0000-0002-9274-2284
Some inborn errors of metabolism and other diseases can result in increasing blood ammonium (hyperammonemia episodes), which can cause serious neurological complications in patients or even death. Early diagnosis, follow up and treatment are essential to minimize irreversible damages in brain. Currently, adequate analytical instrumentation for the necessary ammonium bedside determination is not available in all health centers but only in clinical laboratories of reference hospitals. We therefore have developed a low cost and portable potentiometric Point-of-Care microanalyzer (POC) to address this problem. It consists of a cyclic olefin copolymer-based microanalyzer, the size of a credit card and working in continuous flow, which integrates microfluidics, a gas-diffusion module and a potentiometric detection system. The analytical features achieved are a linear range from 30 to 1000 μmol L NH , a detection limit of 18 μmol L NH and a required sample volume of 100 μL, which comply with the medical requirements. Plasma and blood samples are analyzed with no significant differences observed between ammonium concentrations obtained with both the proposed microanalyzer and the reference method. This demonstrates the value of the developed POC for bedside clinical applications.